Error Codes & Troubleshooting ProblemsHow to troubleshoot spa problemsER-5 POOL TOO HOTER-8 CTRL FAULT HVSProblem:Pool over temperature. Temperature sensor reading ≥ 45 o CProblem:Heater relay is on when it should be offCause:Solutions:High ambient temperatures (especially in summer months) havecaused water temperature to rise above set temp point, Excessivefiltration time, Jet pumps have been operating for extended periodswith the spa cover still onTurn mains power OFF, remove spa cover, allow spa to cool then turnpower back ONCheck daily filtration time (refer filtration section) and reduce dailyfiltration time if requiredCause:Solutions:Power surge, periods of low or high voltage, water on spa packterminal block, relay problemTurn mains power OFF and back ON again to see if spa controlrecovers from ER8 faultInspect under spa cabinet for evidence of water leaking onto spacontrol. If water present, turn mains power OFF and isolate, thenresolve leak, dry up excess water, and allow spa control to dry outbefore restoring power.Check spa cover is not resting on topside panel buttons causing jetpumps to start when cover is on. Use keylock function to lock keypadbuttons when spa not in use.Contact your spa reseller if problem persistsER-10 OVER CURRENTER-6 12V OVERLOADProblem:Mains (230V) current draw above current limit (C.LMT) detectedProblem:Cause:Solutions:12V (port) current draw over 1A limitTotal 12V current drawn by keypad(s), light(s), expansion ports and inpool temp sensor is excessive, 12V power supply is overloaded, toomany LED light bulbs installed, faulty LED lightTurn mains power OFF and restart spa to see if problem reoccursReduce number of LED lights being installedCause:Solutions:Accessory devices current draw is too large for the C.LMT setting,faulty jet pump or air blower drawing excessive current, currentlimit (C.LMT) settings are not configured to match circuit breakerrating, load shed (L.SHD) and/or load limit (L.LMT) settings incorrectTurn mains power OFF and back ON againCheck operation of each pump => attempt to identify problematicpump or blower causing ER10 to occurSystematically unplug lights, in pool temp sensor, keypads andexpansion port loads from spa pack (one by one) to identify faulty partContact your reseller to check controller settings are configured tomatch available power and circuit breaker ratingContact your spa reseller if problem persists<strong>SV</strong> Series <strong>Spa</strong> Controls 27

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!