EDX Series

EDX Series

EDX Series

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SpecificationsSpecificationsMain SpecificationsMeasurement principleMeasurement methodApplicable sample typeMeasurement rangeSample sizeX-ray fluorescence spectrometryEnergy dispersiveSolid, liquid, or powder11Na to 92U (<strong>EDX</strong>-720)6C to 92U (<strong>EDX</strong>-800HS)300 mm (dia.) x 150 mm (H) max.X-ray GeneratorX-ray tubeTube voltageTube currentCooling methodExposure areaPrimary filterRh target5 to 50 kV1 to 1,000 AAir cooling (with fan)10 mm dia. (standard)(Automatic switching between4 settings: 1, 3, 5, and 10 mm dia.)*Automatic switching between 5 typesDetectorTypeLN2 supplyLN2 Dewar capacityLN2 consumption(<strong>EDX</strong>-720/800HS)Si (Li) semiconductor detectorOnly during measurement3 LApprox. 1 L/daySample ChamberAtmosphereSample exchange*Sample observation*Air, vacuum*, helium*8/16-sample turret8-sample turret with spinnerPrecision stageCCD cameraVacuum Unit* (for high-sensitivity analysis of light elements)It is necessary for measurement of elements lighter than S (Sulfur)EvacuationOil rotary vacuum pump, directly connectedVacuum monitor Pirani gaugeAtmospheric-pressure With pressure sensormonitorData Processing Unit (To be procured separately)Main unitIBM PC/AT compatibleMemoryMore than 256 MBHDDMore than 20 GBFDD3.5-inch x 1PrinterColor inkjet printerCDCD-ROM driveOSWindows ® XPSoftwareQualitative analysisQuantitative analysisMatching software(intensity/content)UtilitiesSystem-status monitoring functionAnalysis-result tabulation function(Items with * mark are optional.)Measurement/analysis softwareCalibration-curve method, matrix correction, FP method,Thin-Film FP method, Background FP method.Automatic correction functions (energy correction,FWHM (full-width half-maximum) correction)Installation RequirementsTemperatureRelative humidity<strong>EDX</strong>-720/800HS (AC100V)Power requirements : AC100V10%, 15A, 50/60HzDimensions of the main body : 580(W) x 650(D) x 420(H)mm(23(W) x 26(D) x 17(H)inches)Main body weight : Approx. 80kgFootprint10C to 30C40% to 70%<strong>EDX</strong>-720/800HS/900HS CE type (AC230V)Power requirements : AC220V, 230V, 240A10%, 1000VA, 50/60HzDimensions of the main body : 580(W) x 750(D) x 420(H)mm(23(W) x 30(D) x 17(H)inches)Main body weight : Approx. 100kgSample Pretreatment for X-ray Fluorescence Spectrometry750Wall200 or more580460 3701800: AC230V, CE type ONLYSample formatPowder sampleLiquid sampleSolid sampleFood or biologicalsamplePretreatmentNo pretreatment (put in sample cell)PressingMelting; making glass bead sampleNo pretreatment (put in sample cell)Dropping on paper filter and dryingNo pretreatment (flat part put on stage)Surface polishing, cuttingNo pretreatment (put in sample cell)Mashed into paste using blendermill (put in sample cell)Pretreatment equipmentVibration mill, briquette machineAutomatic bead fusion furnaceSample polisher, latheBlender mill5804208001800Units: mm13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!