11.07.2015 Views

XTV - Raychem RPG

XTV - Raychem RPG

XTV - Raychem RPG

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>XTV</strong>SpecificationsMaximum maintain or continuousexposure temperature (power on)Maximum intermittent exposuretemperature (power on)Temperature classificationBased on systems approach*Minimum installation temperatureMinimum bend radiusThermal output ratingNominal power output at 230 Vac oninsulated steel pipes120°C215°C (20 bar saturated steam)Maximum cumulative exposure 1000 hoursT2: 20<strong>XTV</strong>2-CT-T2T3: 4<strong>XTV</strong>2-CT-T3, 8<strong>XTV</strong>2-CT-T3, 12<strong>XTV</strong>2-CT-T3, 15<strong>XTV</strong>2-CT-T3in accordance with European Standard EN 60079-30-1 5.1.13 and international standards.T3-T6*<strong>Raychem</strong> <strong>XTV</strong> heat-tracing cables are approved for the listed temperature classifications byusing the principles of stabilized design (as per system classification approach) or the use of atemperature limiting device. Use TraceCalc design software or contact Tyco Thermal Controls.–60°Cat 20°C: 13 mmat –60°C: 51 mmA 20<strong>XTV</strong>2-CT-T2B 15<strong>XTV</strong>2-CT-T3C 12<strong>XTV</strong>2-CT-T3D 8<strong>XTV</strong>2-CT-T3E 4<strong>XTV</strong>2-CT-T3A 20<strong>XTV</strong>2B 15<strong>XTV</strong>2C 12<strong>XTV</strong>2D 8<strong>XTV</strong>2E 4<strong>XTV</strong>280W/m70A60BCDE5040302010ABCDE0 20 40 60 80 100 120Pipe temperature (°C)4<strong>XTV</strong>2-CT-T3 8<strong>XTV</strong>2-CT-T3 12<strong>XTV</strong>2-CT-T3 15<strong>XTV</strong>2-CT-T3 20<strong>XTV</strong>2-CT-T2Nominal power output (W/m at 10°C) 12 25 38 47 63Product dimensions (nominal) and weightThickness (mm) 7.2 7.2 7.2 7.2 7.2Width (mm) 11.7 11.7 11.7 11.7 11.7Weight (g/m) 170 170 170 170 170Maximum circuit length based on type ‘C’ circuit breakers according to EN 60898Electrical protection Start-upsizingtemperatureMaximum heating cable length per circuit (m)16 A –20°C 145 90 65 55 40+10°C 170 105 75 60 4525 A –20°C 225 145 105 85 65+10°C 245 165 120 95 7032 A –20°C 245 175 135 105 80+10°C 245 175 140 125 9040 A –20°C 245 175 140 135 105+10°C 245 175 140 135 105The above numbers are for circuit length estimation only. For more detailed information please use the Tyco Thermal Controls TraceCalcsoftware or contact your local Tyco Thermal Controls representative. Tyco Thermal Controls requires the use of a 30 mA residual currentdevice to provide maximum safety and protection from fire. Where design results in higher leakage current, the preferred trip level foradjustable devices is 30 mA above any inherent capacitive leakage characteristic of the heater as specified by the trace heater supplieror alternatively, the next common available trip level for non adjustable devices, with a maximum of 300 mA. All safety aspects need tobe proven.Ordering detailsPart description 4<strong>XTV</strong>2-CT-T3 8<strong>XTV</strong>2-CT-T3 12<strong>XTV</strong>2-CT-T3 15<strong>XTV</strong>2-CT-T3 20<strong>XTV</strong>2-CT-T2Part No. 002735-000 325059-000 427089-000 214999-000 849015-000ComponentsTyco Thermal Controls offers a full range of com po nents for power connections, splices and end seals.These components must be used to ensure proper func tion ing of the product and com pli ance with electrical requirements.2-2EN-<strong>XTV</strong>-DS-DOC2210 www.tycothermal.com


Worldwide HeadquartersTyco Thermal Controls7433 Harwin DriveHouston, TX 77036USATel: 800-545-6258Tel: 650-216-1526Fax: 800-527-5703Fax: 650-474-7711info@tycothermal.comwww.tycothermal.comCanadaTyco Thermal Controls250 West St.Trenton, OntarioCanada K8V 5S2Tel: 800-545-6258Fax: 800-527-5703Latin AmericaTyco Thermal Controls7433 Harwin DriveHouston, TX 77036United StatesTel: 713-868-4800Tel: 713-735-8645Fax: 713-868-2333Europe, Middle East, Africa (EMEA)Tyco Thermal ControlsRomeinse Straat 143001 LeuvenBelgië / BelgiqueTel: +32 16 213 511Fax: +32 16 213 603Asia PacificTyco Thermal Controls20F, Innovation Building,1009 Yi Shan Rd,Shanghai 200233,P.R.ChinaTel: +86 21 2412 1688Fax: +86 21 5426 2937 / 5426 3167Tyco, Alliance Integrated Systems, AMC, AutoMatrix, AutoSol, BTV, CapaciSense, Chemelex, DHSX, DigiTrace, DigiTrace logo,DigiTrace Supervisor, Duoterm, ElectroMelt, EM2XR, FHSM, FHSC, FlexFit, FlexiClic, Flowguard, FreezeTrace, FreezGard,Frostex, Flostex Plus, Frostguard, FroStop, FSE, Gardian, HAK, Handvise, HBTV, HCCL, HotCap, HQTV, HTPG, HTPI, HWAT,H<strong>XTV</strong>, IceStop, Interlock, Isocable, Isodrum, Isoheat, Isomantle, Isopad, Isopad Frostguard, Isopad logo, Isopanel, Isotape,Isotherm, JBM, JBS, K-Flex, K-Flex logo, KHE, KHH, KHL, KHP, KTV, Labsafe, LBTV, LHC, LHFV, LHRV, Metabond, MiniWinterGard, Miser WinterGard, MoniTrace, Multi-plus, NGC, PetroTrace, PLI, PolyMatrix, Pyro CiC, PyroFLX, Pyromaster, Pyropak,Pyrosil, PyroSizer, Pyrotenax, Pyrotenax Designer, Pyrotenax logo, QTVR, QuickNet, QuickNet logo, QuickStat, QuickTerm,RayClic, RaySol, RayStat, Retro WinterGard, RHS, RHSC, RHSM, RMM2, SBF, SBV, SC, SHC, Sheathmaster, ShowerGuard, SLBTV,Smart heat for Comfort and Safety, SnoCalc, SnoCalc logo, STS, System 500, System 1850, System 1850-SE, System 2000,System 2200, T2, T2 logo, T2Blue, T2QuickNet, T2Red, T2Refl ecta, TankCalc Plus, TempBus, Thermoheat, ThermoLimit, Thermo-Line, Total Care in Heat-tracing, Touch, Trac-Loc, Trac Calc, TraceCalc Net, TraceCalc Net logo, TraceCalc Pro logo, TraceGuard 277,TraceMaster, Tracer, Tracer logo, TRACERLYNX, TRACERLYNX logo, TraceStat, TraceTek, TraceTek logo, TruckPak, VLBTV, VLKTV, VPL,We manage the heat you need, WinterGard, WinterGard logo, WinterGard Plus, WinterGard Wet, XL-ERATE, XL-ERATE logo, XL-Trace, <strong>XTV</strong>and Zero EMI are registered and/or unregistered trademarks of Tyco Thermal Controls LLC or its affi liates.All other trademarks are the property of their respective owners.© 2012 Tyco Thermal Controls LLCImportant: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate thesuitability of each product for their particular application. Tyco Thermal Controls makes no warranties as to the accuracy orcompleteness of the information, and disclaims any liability regarding its use. Tyco Thermal Controls' only obligations are thosein the Tyco Thermal Controls Standard Terms and Conditions of Sale for this product, and in no case will Tyco Thermal Controlsor its distributors be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse ofthe product. Specifications are subject to change without notice. In addition, Tyco Thermal Controls reserves the right to makechanges—without notification to Buyer—to processing or materials that do not affect compliance with any applicable specification.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!