Suggestions for connecting accessoriesAll the usual measuring tasks encountered in the public gas distribution industry canbe accomplished by using the impulse generators to be installed in the counter or viathe mechanical output drive - please refer to page 8 -. In addition the high frequencyimpulse generators allow for accurate indication of the instantaneous value (e.g. m 3 /h),as it is used for vehicle diagnostics. Here some examples:Impulse transmissionfrom IZ 9 or IZ 9/2Impulse transmission of the optionally installedimpulse generators (see page 8)Shown for gas meter sizes G 40 to G 400(For gas meter sizes G 650 to G 4000 -temperature connections provided in the pipe)Pressure transmission, G¼G¼ for temperature control measurementG½ for temperature measurementManual checking deviceAfter removing the lockingscrew (sealed), when thegas meter is at standstilland de-pressurized, theease of rotation of thepistons can be checkedmanually by using a boxspanner. Useful duringinstallation and to diagnosemalfunctions.Pressure transmission, G¼9