T<strong>EC</strong>HNICALBULLETINMarch 8, 2013 • TB0313-12<strong>Connect</strong>ing a <strong>T5</strong> Series FMS to a <strong>Wayne</strong> <strong>EC</strong> Distribution <strong>Box</strong>OverviewThis document explains how to connect a <strong>T5</strong> Series Fuel Management System to a <strong>Wayne</strong> <strong>EC</strong> Distribution boxfor the purpose of collecting dispensing data. The data is collected by the <strong>T5</strong> Series Fuel Management System,consolidated, and used to produce inventory reconciliation reports.The <strong>T5</strong> Series Fuel Management System must contain the following equipment to facilitate the collecting ofdispensing data:• TS-DIMIB-internal dispenser interface module• TS-TRAC-Tank inventory reconciliation and autocalibration software• TS-WDCBL-Dresser <strong>Wayne</strong> Adapter CableTSP-WDCBLContains(1) 600-0203 Dresser <strong>Wayne</strong> Adapter Cable1. Plug the <strong>Wayne</strong> Dispenser Interface Cable (p / n 600-0203) into the TS-5 series CURRENT LOOPcommunication port (Figure 1).Current Loop,Comm Port<strong>Wayne</strong>/DresserD<strong>Box</strong>TS-5<strong>Wayne</strong>/Dresser Adapter Cable(P/N 600-0203)Figure 1: <strong>Connect</strong>ing to <strong>Wayne</strong>/Dresser - Typical Installation2. Locate the <strong>Wayne</strong> / Dresser Distribution box and connect the other end of the adapter cable to an unusedpump position in the D-<strong>Box</strong>. If the D-<strong>Box</strong> is full, wire the adapter in “series” with an existing pump. Thefollowing chart shows the relationship between wire color and function.Black Loop 1 –Red Loop 1 +Green Loop 2 –White Loop 2 +


T<strong>EC</strong>HNICALBULLETINMarch 8, 2013 • TB0313-12On <strong>Wayne</strong> / Dresser D-<strong>Box</strong>es with pumps wired into one side of the D-<strong>Box</strong> board, only one loop needs to be connected.For units with both sides of the D-<strong>Box</strong> board wired, Loop 1 and Loop 2 must be connected (Figure 2).Data Lines to DispensersData Lines to Dispensers600-0203 AdapterCable Wires Loop 1600-0203 Adapter Cable WiresLoop 2Communication Lines toConsole/POSFigure 2: <strong>Wayne</strong> / Dresser D-<strong>Box</strong> <strong>Connect</strong>ion ExampleNote: See DIMIB Installation and Programming Manual 000-2048 for more information<strong>Franklin</strong> <strong>Fueling</strong> <strong>Systems</strong> • 3760 Marsh Rd. • Madison, WI 53718 USATel: +1 608 838 8786 • 800 225 9787 • Fax: +1 608 838 6433 • www.franklinfueling.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!