11.07.2015 Views

Glenair Series 319-043 Spec Sheet

Glenair Series 319-043 Spec Sheet

Glenair Series 319-043 Spec Sheet

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>319</strong><strong>319</strong>-<strong>043</strong>EMI/RFI Shield Sock Shrink Boot Adapterwith Optional Shrink BootStandard Profile - Direct CouplingCONNECTORDESIGNATORSA-B * -C-D-E-FG-H-J-K-L-S* Conn. Desig. B See Note 6DIRECTCOUPLINGProduct <strong>Series</strong>ConnectorDesignatorAngle and ProfileJ = 90°H = 45°S = StraightBasic Part No.Finish (Table II)<strong>319</strong> F J <strong>043</strong> M 16 06-6-4 TShrink Boot (Table IV -Omit for None)Length: S only(1/2 inch increments:e.g. 4 = 2 inches)Shield Length (1 inch increments:Minimum 6 inches)Cable Entry (Table V)Shell Size (Table I)Length ± .060 (1.52)Min. Order Length 2.0 Inch(See Note 5)A Thread(Table I)Length *O-Ring* Length± .060 (1.52)Minimum OrderLength 1.5 Inch(See Note 5)STYLE 2(STRAIGHTSee Note 7)B (Table I)CableEntryA Thread(Table I)J(Table III)E(Table IV)J(Table III)G(Table IV)B(Table I)F (Table IV)B(Table I)H (Table IV)Cable Entry.140/.130(3.6/3.3)Typ.Shield Length(Approx.)Single Layer Shield(Tinned Copper)© 2005 <strong>Glenair</strong>, Inc. CAGE Code 06324Printed in U.S.A.GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912www.glenair.com<strong>Series</strong> <strong>319</strong> - Page 8E-Mail: sales@glenair.com


<strong>319</strong>-<strong>043</strong>EMI/RFI Shield Sock Shrink Boot Adapterwith Optional Shrink BootStandard Profile - Direct Coupling<strong>319</strong>DashNo.010203040506070809101112131415161718192021See inside back cover fold-out or pages 13 and 14 for unabridged Tables I and II.ShellSize08/0910/1112/1314/1516/1718/1920/2122/2324/2528/2932/333640EMax.639 (16.2).664 (16.9).688 (17.5).688 (17.5).705 (17.9).705 (17.9).732 (18.6).732 (18.6).748 (19.0).773 (19.6).773 (19.6).800 (20.3).800 (20.3).823 (20.9)1.041 (26.4)1.092 (27.7)1.138 (28.9)1.184 (30.1).823 (20.9)1.041 (26.4)1.092 (27.7)TABLE III: FRONT ADAPTERJ Max - Conn. DesignatorA-E-FJ-H-L-S1.180 (30.0)1.180 (30.0)1.180 (30.0)1.180 (30.0)1.380 (35.0)1.380 (35.0)1.380 (35.0)1.380 (35.0)1.380 (35.0)1.610 (40.9)1.610 (40.9)1.610 (40.9)1.610 (40.9)FMax.952 (24.2).982 (24.9)1.002 (25.5)1.002 (25.5)1.032 (26.2)1.032 (26.2)1.052 (26.7)1.052 (26.7)1.062 (27.0)1.082 (27.5)1.082 (27.5)1.122 (28.5)1.122 (28.5)1.152 (29.3)1.322 (33.6)1.362 (34.6)1.412 (35.9)1.452 (36.9)1.152 (29.3)1.322 (33.6)1.362 (34.6)D-B-G-K1.250 (31.8)1.250 (31.8)1.250 (31.8)1.250 (31.8)1.560 (39.6)1.560 (39.6)1.560 (39.6)1.560 (39.6)1.560 (39.6)1.560 (39.6)1.750 (44.5)1.750 (44.5)2.190 (55.6)TABLE IV: DIMENSIONSGMax.750 (19.1).810 (20.6).870 (22.1).870 (22.1).920 (23.4).920 (23.4).980 (24.9).980 (24.9)1.020 (25.9)1.080 (27.4)1.080 (27.4)1.140 (29.0)1.140 (29.0)1.200 (30.5)1.480 (37.6)1.610 (40.9)1.720 (43.7)1.830 (46.5)1.200 (30.5)1.480 (37.6)1.610 (40.9)HMax1.062 (27.0)1.122 (28.5)1.182 (30.0)1.182 (30.0)1.252 (31.8)1.252 (31.8)1.312 (33.3)1.312 (33.3)1.332 (33.8)1.392 (35.4)1.392 (35.4)1.472 (37.4)1.472 (37.4)1.542 (39.2)1.782 (45.3)1.872 (47.5)1.982 (50.3)2.092 (53.1)1.542 (39.2)1.780 (45.2)1.872 (47.5)1. Cable Entry or range is defined as the accomodation range for the wire bundle or cable.Dimensions shown are not intended for inspection criteria.2. See Shrink Boot Reference Information (page 40).3. Metric dimensions (mm) are indicated in parentheses.4. O-Ring not supplied with Connector Designator A.5. Consult factory for shorter lengths on straight backshells.6. When using Connector Designator B refer to pages 18 and 19 for part number development.7. When maximum cable entry (page 22) is exceeded, Style 2 will be supplied. (Function S only.)C1.735 (44.1)1.915 (48.6)1.915 (48.6)1.915 (48.6)1.915 (48.6)1.915 (48.6)1.915 (48.6)1.915 (48.6)1.915 (48.6)1.915 (48.6)1.915 (48.6)TABLE II: STANDARD FINISHESGLENAIRSYMBOLBMNFTABLE IV: CABLE ENTRYSHRINK BOOTFINISHCadmium Plate, Olive DrabElectroless NickelCadmium Plate, Olive Drab OverElectroless NickelSee Back Cover for Complete Finish Informationand Additional Finish Options© 2005 <strong>Glenair</strong>, Inc. CAGE Code 06324Printed in U.S.A.GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912www.glenair.com<strong>Series</strong> <strong>319</strong> - Page 9E-Mail: sales@glenair.comDashNo.010203040506070809101112131415161718192021222324CableEntry.188 (4.8).250 (6.4).312 (7.9).375 (9.5).438 (11.1).500 (12.7).562 (14.3).625 (15.9).688 (17.5).750 (19.1).812 (20.6).875 (22.2).938 (23.8)1.000 (25.4)1.250 (31.8)1.500 (38.1)1.750 (44.5)2.000 (50.8)1.125 (28.6)1.375 (34.9)1.625 (41.3)1.062 (27.0)1.188 (30.2)1.875 (47.6)ShrinkBootn/an/a770-001S103770-001S103770-001S103770-001S104770-001S104770-001S104770-001S105770-001S105770-001S105770-001S106770-001S106770-001S106770-001S107770-001S108n/an/an/an/an/an/an/an/a

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!