<strong>16</strong> Channel Photomultiplier Head<strong>PML</strong>-<strong>16</strong>• <strong>16</strong> Channel Photomultiplier Head for bh Time-Correlated Single PhotonCounting Modules• 1 by <strong>16</strong> Arrangement of Detector Channels• Simultaneous Measurement in all <strong>16</strong> channels• Direct Connection to bh TCSPC modules• Time Resolution 200 ps• max. Count Rate > 1 MHz<strong>16</strong> Anode PMTAmplifiersEncoderR0Light....R1R2R3ERR-HVTimingto SPC ModuleSPC-300f(t,x,y) modeFWHM = 200 psFor SPC-3 through SPC-7 TCSPC modules, multichannel options for individual detectors and other single photon countingproducts please see individual data sheets and descriptions.<strong>Becker</strong> & <strong>Hickl</strong> GmbHNahmitzer Damm 3012277 BerlinTel. +49 / 30 / 787 56 32Fax. +49 / 30 / 787 57 34email info@becker-hickl.comhttp://www.becker-hickl.comCovered by patent DE 43 39 787i n t e l l i g e n tmeasurementandcontrol systems


<strong>PML</strong>-<strong>16</strong>Specification<strong>16</strong> ChannelsDistance 1mm Width 0.8 mmNumber of Channels <strong>16</strong>Arrangement linear (1 by <strong>16</strong>)Active Area (each channel) 0.8 × <strong>16</strong> mmChannel Pitch1 mmSpectral response300 to 600 nm (bi-alkaline) or300 to 850 nm (multi-alkaline)<strong>16</strong>mmTiming Output PolaritynegativeAverage Timing Pulse Amplitude 40 mVTime Resolution (FWHM) 200 ps (typical value)Time Skew between Channels < 40 ps rms<strong>16</strong> mmTiming Output ConnectorSMA, 50ΩPhotocathode OutlineRouting Signal4 bit + Error Signal,TTL/CMOSRouting Signal Connector 15 pin Sub-D / HDPower Supply± 5V from SPC module, -800...-900V / 0.35 mA from externalHV power supplyHV ConnectorSHVDimensions52 mm × 52 mm × 145 mmApplicationSamplePolychromator<strong>PML</strong>-<strong>16</strong>RoutingWavelength ResolvedFluorescence Decay MeasurementExcitationTimingSPC-3x0 / 4x0 / 5x0Stepping MotorScanning Two-DimensionalObjectsSampleSlit<strong>PML</strong>-<strong>16</strong>RoutingSampleDisplacementTimingSPC-3x0 / 4x0 / 5x0 STP-240<strong>Becker</strong> & <strong>Hickl</strong> GmbHNahmitzer Damm 3012277 BerlinTel. +49 / 30 / 787 56 32Fax. +49 / 30 / 787 57 34email info@becker-hickl.comhttp://www.becker-hickl.comi n t e l l i g e n tmeasurementandcontrol systems

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!