11.07.2015 Views

Lake Stevens HS 2035.. - NoaNet

Lake Stevens HS 2035.. - NoaNet

Lake Stevens HS 2035.. - NoaNet

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CONTACT PERSON: Aaron Diedrichs1512 Fairview St Bellingham WA 98229(Cell) 425-327-6404aarond@blackrockcable.comBRC: 2035-1020 <strong>NoaNet</strong> Stimulus Location: <strong>Lake</strong> <strong>Stevens</strong>ROUTE: New build - RED Overlash - PINK Existing facilities - BLUESUMMARY‐ 13 New PUD Pole Attachments‐ 3 risers‐ 1 NB Vault‐ 2,325' of New Strand‐90' of strand for Anchors.‐ 3 New Anchors‐890' of New Underground‐ 415' of Existing Underground.‐13 BRC bonds on PUD poles‐6 Comm MovesTotal fiber footage is approx.THIS IS PROPRIETARY INFORMATION - NOT FOR DISTRIBUTION 5,215'.Page 1 of 1


Sequence1City<strong>Lake</strong><strong>Stevens</strong>BRC RiserDia / Ht#CablesRS/FSRSRoad Map #116thAve NE29N6E08BFieldPole #MapPole #TypeFiberMFGFiberCountFiber FTG@ Pole Storage CheckLAT LONAnchorLead(15N)NeutralDecimal2nd PowerDecimalLoop DecimalPower RiserDecimalStreet LightDecimalTelco DecimalTelco #2Attach DecOrgnl CATVFTOrgnl CATV INCATV MakeReady2-231065 Enclosure 48.017009 -122.074313 29.9 29.9 29.1 27.3 19.0 20 2 Make 26 0 25.5 25 6 Leave 125' coil for splice case. Y 53CATV FTCATV InCATV DecimalOther #1 FTOther #1 INOther #1 MakeReadyOther #1 FTOther #1 InOther #1DecimalBRC FTBRC InBRC Field NotesBRC BondedContractor NotesBRCFromNeutral2<strong>Lake</strong><strong>Stevens</strong>RS116thBRC to attach 6" below CATV.Ave NE 29N6E08B BCD-3 2-42 Pole 48.017570 -122.074298 25.8 25.8 24.3 19.9 21 11 21 11 21.4 21 5 Leave 200' storage Y 523<strong>Lake</strong><strong>Stevens</strong><strong>Lake</strong>4 <strong>Stevens</strong><strong>Lake</strong>5 <strong>Stevens</strong><strong>Lake</strong>6 <strong>Stevens</strong><strong>Lake</strong>7 <strong>Stevens</strong>RSRSRS116thAve NE 29N6E08B BCD-4 2-43 Pole 48.018124 -122.074289 24.6 24.6 24.6 24.6 22.8 19.8 21 10 21 10 20.1 20 9 BRC to attach at 25.5' above ground level. Y 46116thAve NE 29N6E08B BCD-52-167892 Pole 48.018868 -122.074251 30.8 30.8 29.8 30.6 27.8 25.0 26 10 26 10 26.3 26 4 BRC to attach 6" below CATV. Y 53116thBRC to attach 6" below CATV on the new pole.Ave NE 29N6E08B BCD-6 2-46 Pole 48.019529 -122.074240 24.0 24.0 24.0 24.0 19.0 20 4 20 4 20.0 20 0 Leave 200' storage N 48RS116thAve NE 29N6E08B BCD-6X 2-80 Pole 48.019934 -122.074210 30.3 24.5 26 10 26 10 26.8 26 4 BRC to attach 6" below CATV. N 48116thRS Ave NE 29N6E08B BCD-7 2-47 Pole 48.020309 -122.074241 24.3 24.3 21.3 18.5 20 1 20 1 20.1 19 7 BRC to attach 6" below CATV on the new pole. Y 568<strong>Lake</strong><strong>Stevens</strong>RS116thAve NE 29N6E08B BCD-7X 2-75 Pole 48.020759 -122.074227 25.2 25.2 25.2 25.2 19.8 21 6 21 6 21.5 21 0 BRC to attach 6" below CATV Y 509<strong>Lake</strong><strong>Stevens</strong>RS116thRaise CATV 36". BRC to attach 6" below CATV.Ave NE 29N6E08B BCD-8 2-48 Pole 48.021046 -122.074208 29.3 29.3 29.3 26.3 21.6 23 0 Make 26 0 26.0 25 6 Leave 200' storage Y 46<strong>Lake</strong>10 <strong>Stevens</strong>RS26th StNE29N6E08BBCB-12X 2-49 Riser 48.021412 -122.074180 15N 29.8 29.8 28.0 20.5 21 6 Make 26 6 26.5 26 0 Raise CATV 60". BRC to attach 6" below CATV. Y 46Underground440' of underground - Directional Bore -(1) 2" conduit11 VaultInstall New Basis VaultLeave 150' coil 0Underground450' of underground - Directional Bore -(1) 2" conduit<strong>Lake</strong>12 <strong>Stevens</strong>RS115thAve NE 29N6E08B BCB-16 2-52 Riser 48.021710 -122.076041 25.7 25.7 25.7 25.7 20.3 21 8 Make 22 2 22.2 21 8 Raise CATV 6". BRC to use CATV's old hole. Y 48<strong>Lake</strong>13 <strong>Stevens</strong>RS115thBRC to attach 6" below CATV.Ave NE 29N6E08B BCB-17 2-54 Pole 48.022005 -122.076044 24.3 24.3 24.3 21.5 19.4 20 11 20 11 20.9 20 5 Leave 250' storage Y 46<strong>Lake</strong>14 <strong>Stevens</strong>RS115thAve NE 29N6E06D BCB-18 4-42 Pole 48.022606 -122.076166Raise CATV up to 4" below the Street Light and BRC10N/10E 32.5 32.2 30.2 31.7 26.8 23.5 23.2 25 2 Make 26 0 26.0 24 10 Make 26 4 26.3 25 6to attach 6" below CATV. Both CATV and BRC willhave to double dead end. Y 84


SequenceCityBRC RiserDia / Ht#CablesRS/FSRoad Map #FieldPole #MapPole #TypeFiberMFGFiberCountFiber FTG@ Pole Storage CheckLAT LONAnchorLead(15N)NeutralDecimal2nd PowerDecimalLoop DecimalPower RiserDecimalStreet LightDecimalTelco DecimalTelco #2Attach DecOrgnl CATVFTOrgnl CATV INCATV MakeReadyCATV FTCATV InCATV DecimalOther #1 FTOther #1 INOther #1 MakeReadyOther #1 FTOther #1 InOther #1DecimalBRC FTBRC InBRC Field NotesBRC BondedContractor NotesBRCFromNeutral<strong>Lake</strong>15 <strong>Stevens</strong>RS28th StNE 29N6E06D BCB-19 4-29 Pole 48.022671 -122.076990 30.1 29.7 29.7 24.5 26 0 26 0 26.0 25 6 BRC to attach 6" below CATV. Y 55<strong>Lake</strong>16 <strong>Stevens</strong>RS28th StNE 29N6E06D BCB-20 4-28 Pole 48.022745 -122.077990 30.6 29.3 30.0 28.0 24.5 26 0 26 0 26.0 25 6 BRC to attach 6" below CATV. Y 61<strong>Lake</strong>17 <strong>Stevens</strong>RS113thAve NE 29N6E06D BCB-21 4-24Riser /Encloser 48.022823 -122.0789908W/8S 32.5 32.2 31.2 27.3 24.5 24.3 26 1 Make 26 7 26.6 25 7 Make 26 5 26.4 26 1Raise CATV's both attachments 6". BRC to doubledead end and re-use CATV old positions at 25-7 and26-1Leave 250' coil for a splice case. N 77Underground 215' of existing 4"18113thAve NEVaultExisting vaultLeave 100' coil. 019Underground 125' of existing 4"113thAve NE Vault Existing vault20Underground70' of existing conduit113thAve NE Demarc Leave 50' coil in the MDFPudE 13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!