SPLIT SYSTEM PERFORMANCE DATAEXPANDED PERFORMANCE DATAMODEL: ASZ140361A* / CA*F4860*6A*+TXV / MBR1600**-1 HEATING OPERATIONOutdoor Ambient Temperature65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10MBh 43.5 41.2 38.8 36.2 34.6 33.5 31.1 28.7 28.8 26.6 24.5 23.1 22.3 20.0 17.7 15.5 13.2 10.8Delta T 38.4 36.3 34.2 31.9 30.5 29.6 27.5 25.3 25.4 23.5 21.6 20.4 19.6 17.6 15.6 13.6 11.6 9.5KW 3.05 2.99 2.94 2.88 2.84 2.82 2.76 2.71 2.78 2.72 2.66 2.62 2.60 2.53 2.47 2.41 2.35 2.29AMPS 13.8 12.8 12.0 11.3 10.9 10.7 10.1 9.6 9.2 8.9 8.4 8.3 8.2 7.8 7.3 6.9 6.4 5.8COP 4.17 4.02 3.86 3.68 3.56 3.48 3.30 3.11 3.03 2.86 2.70 2.58 2.51 2.31 2.10 1.87 1.64 1.38EER 14.3 13.8 13.2 12.6 12.2 11.9 11.3 10.6 10.4 9.8 9.2 8.8 8.6 7.9 7.2 6.4 5.6 4.7High pressure is measured at the liquid service valve (the smaller valve).Low pressure is measured at the gauge port connection.Calculations are based on nominal CFM and 70 °F indoor dry bulb.AMPS = Outdoor unit amps (comp.+fan)KW = Total system power32