HEAT PUMP SPECIFICATIONSASZ140[18,30,36,38]1AA-AF; ASZ140241AA-AG; ASZ140[42,48,60]1AA-AEASZ140181AA-AFASZ140241AA-AGASZ140301AA-AFASZ140361AA-AFASZ140381AAASZ140421AA-AEASZ140481AA-AEASZ140601AA-AECooling Capacity, BTUH 18,000 24,000 30,000 36,000 36,000 42,000 48,000 60,000CompressorR.L. Amps 9.0 12.8 14.1 16.7 14.10 17.9 19.9 26.4L.R. Amps 48.0 58.3 73.0 79.0 77.0 112.0 109.0 134.0Low Pressure SwitchOpen 22 PSIG 22 PSIG 22 PSIG 22 PSIG 22 PSIG 22 PSIG 22 PSIG 22 PSIGClose 50 PSIG 50 PSIG 50 PSIG 50 PSIG 50 PSIG 50 PSIG 50 PSIG 50 PSIGHigh Pressure SwitchOpen 610 PSIG 610 PSIG 610 PSIG 610 PSIG 610 PSIG 610 PSIG 610 PSIG 610 PSIGClose 420 PSIG 420 PSIG 420 PSIG 420 PSIG 420 PSIG 420 PSIG 420 PSIG 420 PSIGCondenser Fan MotorHorsepower 1/12 1/6 1/6 1/4 1/6 1/4 1/4 1/4F.L. Amps 0.6 0.9 1.1 1.5 1 1.5 1.5 1.5Liquid Line, Inches O.D.* 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8"Suction Line, Inches O.D.* 3/4" 3/4" 3/4" 7/8" 7/8" 7/8" 7/8" 7/8"Refrigerant Charge 143.0 173.0 188.0 213.0 211.0 213.0 273.0 278.0Power Supply 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1Minimum Circuit Ampacity (1) 11.8 16.9 18.7 22.4 18.60 23.9 26.4 34.5Maximum Overcurrent Device (2) 20 20 30 30 30 40 40 60Electrical Conduit SizePower Supply (Inches) 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4Approximate Shipping Weight 191 201 203 242 242 268 300 314*Up to 24' in equivalent line length(1)Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.(2)Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or <strong>HAC</strong>R type Circuit Breaker of the same size as noted.NOTES:• Always check the S & R plate for electrical data on the unit being installed.• Installer will need to supply 7/8" to 1-1/8" adapters for suction line connections (4 & 5 ton units).• Installer will need to supply 3/4" to 7/8" adapters for suction line connections (3 ton unit).• Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final ChargeProcedure.• Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THEOUTDOOR UNIT, NOT THE INDOOR COIL.NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers andwires in accordance with all national and/or local electrical codes. Use copper wire only.Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date generaland electrical information.5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!