11.07.2015 Views

DYMAX BlueWave 200 UV Curing Spot Lamp with Intensity ...

DYMAX BlueWave 200 UV Curing Spot Lamp with Intensity ...

DYMAX BlueWave 200 UV Curing Spot Lamp with Intensity ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

BLAZE TECHNOLOGY PTE LTDSPECIFICATIONSInitial Intensities<strong>Intensity</strong> AdjustmentPower RequirementsPower SupplyBulbReflectorShutter TimerShutter ActivationI/O PortTotal (280-450 nm)Visible (400-450 nm)<strong>UV</strong>A 1 (320-395 nm)<strong>UV</strong>B (280-320 nm)40+ W/cm 217+ W/cm 217+ W/cm 27 W/cm 2Manual from 1% to 100% output90-264V, 47-63 HzSolid-state, <strong>200</strong> Watt<strong>200</strong> Watt mercury bulb included; replacement in less than one minuteElliptical; glass <strong>with</strong> dichroic coating to reflect <strong>UV</strong> and minimize IRDigital LCD timer up to 99.99 seconds; manual or timed shutterFoot switch or PLC9 pin D – sub-miniature connectorInputs: Shutter activate, shutter deactivateSignals (PLC Integration)Outputs: <strong>Lamp</strong> on, lamp off, replace lampShutter opened, shutter closed, shutter faultCoolingFiltered, dual-fan arrangement; thermally controlled to maintain properlamp temperatureHour MeterDigital LCD; total unit operating hours (non re-settable) and total bulb hours(re-settable)Overall Dimensions12” x 12” x 6.5” (30.5 cm x 30.5 cm x 16.5 cm)Weight12 lbs. (5.4 kg)System WarrantyOne year from purchaseBulb WarrantyIgnition warranted for 2,000 hoursReplacement Bulb 38465PART NUMBERSNorth American Version(115V standard plug)38905International Version (<strong>with</strong> no plug) 386051As measured <strong>with</strong> a <strong>DYMAX</strong> ACCU-CAL 50 Radiometer (320-395 nm). Excessive on/off cycles and improper cooling may affect bulb degradationand therefore no warranty is expressed or implied.PartNumberTable 1 – Recommended Lightguides (sold separately)Lightguide Description(all noted are liquid filled,quartz fiber are also available)MinimumInitial<strong>Intensity</strong> 1(W/cm 2 )Typical<strong>Intensity</strong> at2,000 Hours 1(W/cm 2 )5720 Single pole 5 mm x 1 Meter 17.0 8.05721 Single pole 5 mm x 1.5 Meters 16.0 7.55722 Single pole 8 mm x 1 Meter 13.0 6.538476 Two pole 3 mm x 1 Meter 10.5 5.238477 Three pole 3 mm x 1 Meter 9.0 4.538478 Four pole 3 mm x 1 Meter 7.4 3.71As measured <strong>with</strong> a <strong>DYMAX</strong> ACCU-CAL 50 Radiometer (320-395 nm). Excessive on/off cyclesand improper cooling may affect bulb degradation and therefore no warranty is expressed or implied.Trifurcated wand curingmetal-to-plastic assemblyPage 3For Local Support Singapore 65 6270 2188 Malaysia 604 390 5882 Thailand 66 2361 2926 Email sales@blazeasia.com www.blazeasia.com


BLAZE TECHNOLOGY PTE LTDLightguide Mounting Stand(fits 3 mm, 5 mm and 8 mm lightguides)PN 39700ACCU-CAL 50 Radiometerfor measuring the <strong>UV</strong> intensity ofspot lamps, flood lamps andconveyor systems PN 39560<strong>UV</strong>-Blocking, Over-the-GlassesEye ProtectionClear PN 35284 • Tinted PN 35285Dark Tint PN 35286Liquid-Lightguidesavailable in 1, 2, 3 & 4-pole configurations (seeTable 1. on Page 2 for sizes and part numbers)Angled Terminators for Lightguides3 mm/60° PN 39029 • 3 mm/90° PN 390305 mm/60° PN 38042 • 5 mm/90° PN 38049Rod LensesShown: <strong>BlueWave</strong> <strong>200</strong> <strong>with</strong> 8 mm rod lens(rod lenses require an 8 mm lightguide)2” x 2” Area (∼100 mW/cm 2 ) PN 386995” x 5” Area (∼30 mW/cm 2 ) PN 38698FREE <strong>DYMAX</strong> EQUIPMENT EVALUATIONContact your <strong>DYMAX</strong> representative to initiate rental of <strong>DYMAX</strong> <strong>UV</strong> light-curingequipment. The highlights of the <strong>DYMAX</strong> Trial Rental/Lease program are:• Two (2) weeks free evaluation and 3% per week thereafter• Eight (8) weeks of rental fees are deducted from the price at purchase• 50% of additional rental fees are deducted• Customer pays shipping both ways© <strong>200</strong>6 - 2011 <strong>DYMAX</strong> Corporation. All rights reserved. All trademarks in this guide, except where noted, are the property of, or used under license by <strong>DYMAX</strong> Corporation, U.S.A.Please note that most dispensing and curing system applications are unique. <strong>DYMAX</strong> does not warrant the fitness of the product for the intended application. Any warranty applicable to the product,its application and use is strictly limited to that contained in <strong>DYMAX</strong>’s standard Conditions of Sale. <strong>DYMAX</strong> recommends that any intended application be evaluated and tested by the user to insure thatdesired performance criteria are satisfied. <strong>DYMAX</strong> is willing to assist users in their performance testing and evaluation by offering equipment trial rental and leasing programs to assist in such testing andevaluation. Data sheets are available for valve controllers or pressure pots upon request. LIT218 04/19/2011<strong>DYMAX</strong> Corporation860.482.1010info@dymax.comwww.dymax.com<strong>DYMAX</strong> Europe GmbH+49 (0) 611.962.7900info_de@dymax.comwww.dymax.de<strong>DYMAX</strong> <strong>UV</strong> Adhesives &Equipment (Shenzhen) Co Ltd+86.755.83485759dymaxasia@dymax.comwww.dymax.com.cn<strong>DYMAX</strong> Asia (Hong Kong) Ltd+852.2460.7038dymaxasia@dymax.comwww.dymax.com.cn<strong>DYMAX</strong> Korea LLC82.2.784.3434info@dymax.krwww.dymax.co.krFor Local Support Singapore 65 6270 2188 Malaysia 604 390 5882 Thailand 66 2361 2926 Email sales@blazeasia.com www.blazeasia.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!