The Raychem <strong>RayClic</strong> connection system<br />
is a simple, fast <strong>and</strong> reliable set of<br />
connection kits developed for select<br />
XL-Trace, IceStop <strong>and</strong> HWAT self-regulating<br />
heating cables. There is no wire stripping<br />
needed because the insulation displacement<br />
connector makes the electrical connection.<br />
<strong>RayClic</strong> <strong>Connection</strong> <strong>Kits</strong><br />
<strong>and</strong> <strong>Accessories</strong><br />
The easy-to-install <strong>RayClic</strong> connection<br />
system reduces installation time, lowering<br />
the total installed cost of the heating cable<br />
system.<br />
Simple<br />
• No need for special tools<br />
• Three-step installation<br />
Reliable<br />
• Intuitive installation<br />
• Rugged, waterproof, UV-resistant<br />
enclosure<br />
Cost-effective<br />
• Quick installation<br />
Powered <strong>Connection</strong> <strong>Kits</strong><br />
Catalog number Part number Description<br />
<strong>RayClic</strong>-PC 233053-000 A <strong>RayClic</strong>-PC can supply power to one heating cable. Each kit contains one <strong>RayClic</strong>-PC power<br />
connection, one <strong>RayClic</strong>-E end seal, <strong>and</strong> one SB-04 pipe mounting bracket. The kit includes 5'<br />
power lead wires <strong>and</strong> a conduit fitting; the junction box <strong>and</strong> flexible conduit required to make a<br />
complete connection are not included.<br />
Weight: 1.8 lb (0.8 kg)<br />
<strong>RayClic</strong>-PS 861247-000 A <strong>RayClic</strong>-PS can be used as a power connection kit for supplying power to two heating cables.<br />
Each kit contains one <strong>RayClic</strong>-PS powered splice connection, two <strong>RayClic</strong>-E end seals, <strong>and</strong> one<br />
SB-04 pipe mounting bracket. The kit includes 5' power lead wires <strong>and</strong> a conduit fitting. The<br />
junction box <strong>and</strong> flexible conduit required to make a complete connection are not included.<br />
Weight: 2.0 lb (0.9 kg)<br />
<strong>RayClic</strong>-PT 804231-000 A <strong>RayClic</strong>-PT can be used as a power connection kit for supplying power to three heating cables.<br />
Each kit contains one <strong>RayClic</strong>-PT powered tee connection, three <strong>RayClic</strong>-E end seals, <strong>and</strong> one<br />
SB-04 pipe mounting bracket. The kit includes 5' power lead wires <strong>and</strong> a conduit fitting. The<br />
junction box <strong>and</strong> flexible conduit required to make a complete connection are not included.<br />
Weight: 2.0 lb (0.9 kg)<br />
R<br />
<strong>RayClic</strong><br />
3 1/8"<br />
WARNING: SHOCK HAZARD<br />
Do not open while energized<br />
R<br />
LISTED DESIG. 3A, 3B, 3C, 2E<br />
<strong>Connection</strong> kits <strong>and</strong> accessories for<br />
XL-Trace, IceStop <strong>and</strong> HWAT<br />
self-regulating heating cables<br />
Unpowered <strong>Connection</strong> <strong>Kits</strong><br />
Catalog number Part number Description<br />
<strong>RayClic</strong>-S<br />
559871-000 Splice kits are installed as needed to connect two heating cables together at one point. Each kit<br />
contains one <strong>RayClic</strong>-S splice.<br />
Weight: 1.3 lb (0.6 kg)<br />
<strong>RayClic</strong>-T 014023-000 Tee kits are installed as needed to connect three heating cables together at one point. Each kit<br />
contains one <strong>RayClic</strong>-T tee connection <strong>and</strong> one <strong>RayClic</strong>-E end seal.<br />
Weight: 1.9 lb (0.9 kg)<br />
H57545 2/12 www.tycothermal.com 1 of 3<br />
1. Pipe Freeze<br />
Protection <strong>and</strong><br />
Flow Maintenance<br />
2. Fire Sprinkler<br />
System Freeze<br />
Protection<br />
3. Roof <strong>and</strong> Gutter<br />
De-Icing<br />
4. Surface Snow<br />
Melting – MI<br />
5. Surface Snow<br />
Melting <strong>and</strong> Anti-<br />
Icing – ElectroMelt<br />
6. Freezer Frost<br />
Heave Prevention<br />
7. Floor Heating 8. Technical Data<br />
Sheets
<strong>RayClic</strong> <strong>Connection</strong> <strong>Kits</strong> <strong>and</strong> <strong>Accessories</strong><br />
Unpowered <strong>Connection</strong> <strong>Kits</strong> (Continued)<br />
Catalog number Part number Description<br />
<strong>RayClic</strong>-X<br />
R<br />
546349-000 <strong>RayClic</strong>-X kits are installed as needed to connect four heating cables together at one point. Each<br />
kit contains one <strong>RayClic</strong>-X cross <strong>and</strong> two <strong>RayClic</strong>-E end seals.<br />
Weight: 2.0 lb (0.9 kg)<br />
<strong>RayClic</strong>-LE P000000770 Lighted end seal kits are installed wherever an end-of-line signal light is required. Each kit<br />
contains one <strong>RayClic</strong>-LE lighted end seal <strong>and</strong> one <strong>RayClic</strong>-SB-04 pipe mounting bracket.<br />
Weight: 1.8 lb (0.8 kg)<br />
<strong>Accessories</strong><br />
Catalog number Part number Description<br />
<strong>RayClic</strong>-E 805979-000 The <strong>RayClic</strong>-E is a replacement end seal kit.<br />
<strong>RayClic</strong>-SB-02 852001-000 The <strong>RayClic</strong>-SB-02 is a wall mounting bracket for use with any <strong>RayClic</strong> connection kit.<br />
<strong>RayClic</strong>-SB-04 616809-000 The <strong>RayClic</strong>-SB-04 is a pipe mounting bracket for use with any <strong>RayClic</strong> connection kit. One pipe<br />
mounting bracket is included with each powered connection kit <strong>and</strong> the <strong>RayClic</strong>-LE lighted end<br />
seal kit.<br />
<strong>RayClic</strong> System Specifications<br />
Applicable Products<br />
Rated voltage 120–277 V<br />
Maximum circuit breaker size 30 A<br />
Maximum exposure temperature 150°F (65°C)<br />
Minimum installation temperature 0°F (–18°C)<br />
Enclosure rating NEMA 4X<br />
XL-Trace 5/8XL1-CR/CT <strong>and</strong> 5/8/12XL2-CR/CT<br />
IceStop GM-1XT, GM-1X, GM-2XT <strong>and</strong> GM-2X<br />
HWAT HWAT-R2, HWAT-P1<br />
2 of 3 www.tycothermal.com H57545 2/12
Approvals<br />
<strong>RayClic</strong> <strong>Connection</strong> <strong>Kits</strong> <strong>and</strong> <strong>Accessories</strong><br />
Design <strong>and</strong> Installation For proper design <strong>and</strong> installation of a <strong>RayClic</strong> connection system, use the appropriate product<br />
design guide <strong>and</strong> the installation instructions included with the connection kit.<br />
Ground-Fault Protection To minimize the danger of fire from sustained electrical arcing if the heating cable is damaged<br />
or improperly installed, <strong>and</strong> to comply with the requirements of <strong>Tyco</strong> <strong>Thermal</strong> <strong>Controls</strong>, agency<br />
certifications, <strong>and</strong> national electrical codes, ground-fault equipment protection must be used on<br />
each heating cable branch circuit. Arcing may not be stopped by conventional circuit protection.<br />
Many DigiTrace control <strong>and</strong> monitoring systems meet the ground-fault protection requirement.<br />
H57545 2/12 www.tycothermal.com 3 of 3<br />
1. Pipe Freeze<br />
Protection <strong>and</strong><br />
Flow Maintenance<br />
2. Fire Sprinkler<br />
System Freeze<br />
Protection<br />
3. Roof <strong>and</strong> Gutter<br />
De-Icing<br />
4. Surface Snow<br />
Melting – MI<br />
5. Surface Snow<br />
Melting <strong>and</strong> Anti-<br />
Icing – ElectroMelt<br />
6. Freezer Frost<br />
Heave Prevention<br />
7. Floor Heating 8. Technical Data<br />
Sheets
Worldwide Headquarters<br />
<strong>Tyco</strong> <strong>Thermal</strong> <strong>Controls</strong><br />
7433 Harwin Drive<br />
Houston, TX 77036<br />
USA<br />
Tel: 800-545-6258<br />
Tel: 650-216-1526<br />
Fax: 800-527-5703<br />
Fax: 650-474-7711<br />
info@tycothermal.com<br />
www.tycothermal.com<br />
Canada<br />
<strong>Tyco</strong> <strong>Thermal</strong> <strong>Controls</strong><br />
250 West St.<br />
Trenton, Ontario K8V 5S2<br />
Canada<br />
Tel: 800-545-6258<br />
Fax: 800-527-5703<br />
Tel: 613-392-6571<br />
Fax: 613-392-3999<br />
Latin America<br />
<strong>Tyco</strong> <strong>Thermal</strong> <strong>Controls</strong><br />
Al. Araguaia, 2044 – Sala.1101,<br />
Bloco B<br />
Edificio CEA – Alphaville<br />
Barueri – Sao Paulo – Brasil<br />
06455-000<br />
Tel: +55 11 2588 1400<br />
Fax: +55 11 2588 1410<br />
Europe, Middle East, Africa<br />
<strong>Tyco</strong> <strong>Thermal</strong> <strong>Controls</strong><br />
Romeinse straat 14<br />
3001 Leuven<br />
België / Belgique<br />
Tel: +32 16 213 511<br />
Fax: +32 16 213 603<br />
Asia Pacific<br />
<strong>Tyco</strong> <strong>Thermal</strong> <strong>Controls</strong><br />
20F, Innovation Building,<br />
1009 Yi Shan Rd,<br />
Shanghai 200233, P.R.China<br />
Tel: +86 21 2412 1688<br />
Fax: +86 21 5426 2937 / 5426 3167<br />
<strong>Tyco</strong>, Alliance Integrated Systems, AMC, AutoMatrix, AutoSol, BTV, CapaciSense, Chemelex, DHSX, DigiTrace, DigiTrace logo,<br />
DigiTrace Supervisor, Duoterm, ElectroMelt, EM2XR, FHSM, FHSC, FlexFit, FlexiClic, Flowguard, FreezeTrace, FreezGard,<br />
Frostex, Frostex Plus, Frostguard, FroStop, FSE, Gardian, HAK, H<strong>and</strong>vise, HBTV, HCCL, HotCap, HQTV, HTPG, HTPI, HWAT, HXTV,<br />
IceStop, Interlock, JBM, JBS, K-Flex, K-Flex logo, KHE, KHH, KHL, KHP, KTV, Labsafe, LBTV, LHC, LHFV, LHRV, Metabond, Mini<br />
WinterGard, Miser WinterGard, MoniTrace, Multi-plus, NGC, PetroTrace, PLI, PolyMatrix, Pyro CiC, PyroFLX, Pyromaster, Pyropak,<br />
Pyrosil, PyroSizer, Pyrotenax, Pyrotenax Designer, Pyrotenax logo, QTVR, QuickNet, QuickNet logo, QuickStat, QuickTerm,<br />
<strong>RayClic</strong>, RaySol, RayStat, Retro WinterGard, RHS, RHSC, RHSM, RMM2, SBF, SBV, SC, SHC, Sheathmaster, ShowerGuard, SLBTV,<br />
Smart Heat for Comfort <strong>and</strong> Safety, SnoCalc, SnoCalc logo, STS, System 500, System 1850, System 1850-SE, System 2000,<br />
System 2200, T2, T2 logo, T2Blue, T2QuickNet, T2Red, T2Reflecta, TankCalc Plus, TempBus, Thermoheat, ThermoLimit, Thermo-<br />
Line, Total Care in Heat-tracing, Touch, Trac-Loc, Trac Calc, TraceCalc Net, TraceCalc Net logo, TraceCalc Pro logo, TraceGuard 277,<br />
TraceMaster, Tracer, Tracer logo, TRACERLYNX, TRACERLYNX logo, TraceStat, TraceTek, TraceTek logo, TruckPak, VLBTV, VLKTV, VPL,<br />
We manage the heat you need, WinterGard, WinterGard logo, WinterGard Plus, WinterGard Wet, XL-ERATE, XL-ERATE logo, XL-Trace,<br />
XTV <strong>and</strong> Zero EMI are registered <strong>and</strong>/or unregistered trademarks of <strong>Tyco</strong> <strong>Thermal</strong> <strong>Controls</strong> LLC or its affiliates.<br />
All other trademarks are the property of their respective owners.<br />
Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the<br />
suitability of each product for their particular application. <strong>Tyco</strong> <strong>Thermal</strong> <strong>Controls</strong> makes no warranties as to the accuracy or<br />
completeness of the information, <strong>and</strong> disclaims any liability regarding its use. <strong>Tyco</strong> <strong>Thermal</strong> <strong>Controls</strong>' only obligations are those<br />
in the <strong>Tyco</strong> <strong>Thermal</strong> <strong>Controls</strong> St<strong>and</strong>ard Terms <strong>and</strong> Conditions of Sale for this product, <strong>and</strong> in no case will <strong>Tyco</strong> <strong>Thermal</strong> <strong>Controls</strong><br />
or its distributors be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of<br />
the product. Specifications are subject to change without notice. In addition, <strong>Tyco</strong> <strong>Thermal</strong> <strong>Controls</strong> reserves the right to make<br />
changes—without notification to Buyer—to processing or materials that do not affect compliance with any applicable specification.<br />
© 2012 <strong>Tyco</strong> <strong>Thermal</strong> <strong>Controls</strong> LLC