11.07.2015 Views

Emerson Network Power Rack PDUs

Emerson Network Power Rack PDUs

Emerson Network Power Rack PDUs

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Knürr DI-STRIP ® Safety BasicStandard DIN 49 440DOS20068DOS00306DOS00270With overvoltage protectionWith overvoltage protectionWith overvoltage protection- For protecting against transient overvoltagesfrom the mains, which, for example, are causedby switching machines on and off.- With critical overvoltages the mains is separated.- Once the safety arrester has been triggered thegreen function display goes out. The socket stripcan then no longer be used.Send the socket strip to the manufacturer for thesafety arrester to be replaced!The safety effect of the type 3 test category andrequirements category "D" is to protect theequipment, i.e. precision protection.The protection devices of the test and requirementscategories 1 and 2 and B and C must bepreconnected in the building installation to ensureoptimum protection.- 19” installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm 2- Molded right angle plugMaterial/finishHousing: closed sheet steel extrusion, zincpassivated,powder-coated texturePlastic parts: Vampamid 6 0024 VO (UL94), recyclableInternal conductor: full-length busbar, brassApprovals/certificates- CE label in accordance with Low VoltageDirective 2006/95/EC- EMC Directive 2004/108/EC- GS- CB-schemeColor combinationFinal digit of order number .1:RAL 7035 light grayFinal digit of order number .6:Housing: RAL 2003 pastel orangePlastic parts: RAL 7035 light grayTechnical dataTest category: Type 3- In acc. with DIN EN 61643-11Requirements class: D- In acc. with VDE 0675-6Mains voltage: 230 VACNominal current: max. 16 ACut-off discharge current (8/20 μs): 10 kAResponse time: ‹ 25 nsProtection level(with 100 A varistor peak current):- L with respect to N: ‹ 800 V- L/N with respect to PE: ‹ 1500 VDimensionsSocket spacing: 50 mmHeight: 45.5 mmHousing width: 44.4 mm (= 1 U)Supply schedule1 socket strip2 mounting bracketL S n F1 F2 19” Safe Model Order no. UP732 10 • 03.316.110.1 1 unit683 10 • 03.316.010.x 1 unit532 6 • • 03.317.106.1 1 unit532 6 • 03.316.106.1 1 unit03.316.006.x 1 unit483 6 • •432 4 • •432 4 •383 4 •03.317.104.1 1 unit03.316.104.1 1 unit03.316.004.1 1 unitDimensions in mm: L = Length, S = Switch, n = Number of sockets,F1 = Standard side, F2 = Design side, 19”= Suitable for 19” installation,Safe = Child-safe, U =Standard height unit, UP = Unit of packaging,= Express itemConversion: 1 mm = 0.03937 inch 1 kg = 2.2046 poundReplace .x with the number of your color combination:.1 = RAL 7035, .6 = RAL 7035/RAL 20032.34

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!