11.07.2015 Views

Emerson Network Power Rack PDUs

Emerson Network Power Rack PDUs

Emerson Network Power Rack PDUs

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Emerson</strong> <strong>Network</strong> <strong>Power</strong> <strong>Rack</strong> <strong>PDUs</strong>Liebert MPX TM : Four equipment modelsfor different requirementsThe Liebert MPX TM modular rack PDUconsists of various modules. Thefoundation stone is a busbar, whichis responsible for the power andcommunication distribution to theindividual modules. The input poweris routed via the Liebert MPX TM <strong>Power</strong>Entry Module (Liebert MPX TM PEM) tothe Liebert MPX TM system. Differentoutput modules (Liebert MPX TMBranch Receptacle Modules, LiebertMPX TM BRM) are available as required.Four different variants can be set updepending on the busbars' equipping:1. Liebert MPX TM ElementaryModular basic power distribution withoutmeasurement and control function. Anupgrade to another equipment model isno problem!2. Liebert MPX TM Elementary PhasemonitoredModular power distribution withmeasurement on the input per outputmodule. An upgrade to the next lineup is possible by equipping with therespective output modules.3. Liebert MPX TM Branch monitoredModular power distribution withmeasurement on the input per outputmodule. An upgrade or downgrade toanother line is possible by equipping withthe respective output modules.4. Liebert MPX TM Receptacle managedModular power distribution withmeasurement on the input per outputmodule and per output. The individualoutputs can also be switched on and offremotely. A downgrade to another line ispossible by equipping with the respectiveoutput modules.A combination of the "ElementaryPhase monitored", "Branch monitored"and "Receptacle managed" lines on ashared busbar is also possible and isone of the exceptional features of theLiebert MPX TM . Interfaces for the networkcommunication, the sensors and/or thelocal display are provided by the Liebert<strong>Rack</strong> PDU Card (Liebert RPC) in the LiebertMPX TM PEM. The Liebert RPC Card enablesconnection to an optional RPC BasicDisplay Module (RPC BDM) to display thelocal status and alarms.Output moduleReceptacle ManagedBusbar(Liebert MPX TM PRC)Distributes power andcommunication signalsto all modules.Output module Branchmonitored(Liebert MPX TM BRM)Spacer for busbarsFills unused gaps until aLiebert MPX TM module isupgraded.Output module e.g.Elementary (LiebertMPX TM BRM)<strong>Power</strong> input module(Liebert MPX TM PEM)Routes the input powerand the data (dependingon the module type) to thebusbar system.2.6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!