SALISBURY LINE EQUIPMENTSalisbury pioneered the manufacture of linemen’s RubberProtective Equipment in the early 1920’s. Today, Salisburyis the leader in Personal Electrical-Safety Protection.We know that lives depend on the quality of our products,Salisbury’s production facilities are all ISO 9001:2000registered and have been equipped and staffed to manufactureproducts which conform to the highest possiblestandards. This has allowed Salisbury to become theworld-wide leader in electrical safety rubber gloves.Salisbury now has four plants which manufacture RubberProtective Equipment, Hot Line Equipment, and SALVAR®Polymer Insulators. Only Salisbury produces its ownrubber products in its own plants using four methods ofrubber manufacture: Injection Molding, Compression/Transfer Molding, Extruding and Dipping. Salisbury’sdedication to quality has also been carried over to themanufacture of Hot Line Tools and SALVAR Insulators. Asa result, the name Salisbury on safety products is yourassurance that you are using the finest equipmentavailable for the job.OUR SISTER COMPANIES:www.northsafety.comwww.nspusa.come-mail uswww.totalfiregroup.commore info S ALISBURYwww.wh<strong>salisbury</strong>.comSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401A-3


ASTM SPECIFICATIONS & USER TRAININGCautionLine Equipment should only be used by electrical workers who have been thoroughlytrained in its correct and safe use. Training should be conducted in accordance with theemployer’s work procedures and standards. Salisbury Line Equipment training materialsare available to assist employers with this essential requirement.ASTM Specifications for Salisbury EquipmentGloves, Sleeves and FootwearASTM D120 Rubber Insulating GloveASTM D1051 Rubber Insulating SleevesASTM F696 Leather Protectors for Insulating Gloves and MittensASTM F496 In-Service Care for Insulating Gloves and MittensASTM F1116 Test Method for Dielectric strength of overshoe footwearASTM F1117 Specification for Dielectric overshoe footwearInsulating Blanket, Matting and SheetingASTM D 178 Rubber Insulating Switchboard MattingASTM D1048 Rubber Insulating BlanketsASTM F479 In-Service Care of Insulating BlanketsASTM F2320 Rubber Insulating SheetingASTM F1742 PVC Insulating SheetingLine Hose and CoversASTM D1049 Rubber Insulating Insulator CoversASTM D1050 Rubber Insulating Line HoseASTM F478 In-Service care for Insulating Line Hose and CoversHotstick Grounds and Bypass JumpersASTM F711 Fiberglass reinforced Plastic Rod and Tube used in Live Line ToolsASTM F855 Temporary Grounding Systems to be used on De-energized Electrical Power Lines & EquipmentASTM F2321 Flexible Insulated Temporary By-Pass JumpersASTM F2249 In-Service Test Methods for Temporary Grounding Jumper AssembliesUsed on De-Energized Electric Power Lines & EquipmentPlastic EquipmentASTM F968 Specifications for Electrically Insulating Plastic Guard Equipment for Protection of WorkersASTM F712 Test Methods for Electrically Insulating Plastic Guards Equipment for Protection of Workerswww.osha.govwww.astm.orgwww.nfpa.orgSalisbury meets all necessary ASTM, OSHAand NFPA regulations and standards.Salisbury is ISO 9001:2000 Registered.SALISBURY Insulating Line Hose and Covers. www.wh<strong>salisbury</strong>.com


ASTM CHARTASTM ChartRUBBER AND SALCOR® PROTECTIVE EQUIPMENTRubber insulating glovesoves are available in six ASTM definedvoltage classes. Rubber insulating sleeves are available in Class 0through 4. The chart below identifies the class, proof test voltageand maximum allowable exposure voltage.For an 8 x 10 reprint of this chart, contact your local Salisbury representative.ASTM Labeling Chartfor Salisbury Linemen’s Natural Rubber and SALCOR® Rubber Protective EquipmentProof Test Max. Use Rubber Conventional WorkClass Voltage Voltage Molded Glove Label Rubber Dipped Position for ElectricalColor AC / DC AC / DC* Products Sleeve Label Worker or LinemanLabel00Beige2500 / 10,000 500 / 750* Ground, Structureor Basket0Red5,000 / 20,000 1,000 / 1,500* Ground, Structureor Basket1White10,000 / 40,000 7,500 / 11,250* Structure orBasket2Yellow20,000 / 50,000 17,000 / 25,500* Electrically IsolatedBasket or Platform3Green4Orange30,000 / 60,000 26,500 / 39,750* Electrically IsolatedBasket or Platform40,000 / 70,000 36,000 / 54,000* Electrically IsolatedBasket or Platform*Maximum use DC voltage is not part of any ASTM specification. Maximum use DC voltages are valid in reference to IEC 903 only.Gloves and Sleeves must have a color coded label.“Suitable for live working.”IEC60903:2002 & IEC60417 fig. 5216SALISBURY Insulating Line Hose and Covers. www.wh<strong>salisbury</strong>.com


GENERAL CARE & INSPECTION OF SALISBURY RUBBER GOODSType I natural (non-ozone resistant) and Type II SALCOR® synthetic rubber (resistant to ozone) bothprovide electrical workers with the highest level of electrical insulating protection. However, in order tomaintain this level of protection and ensure long life, it is essential that rubber goods are properlycared for. Before each use, rubber goods should be visually inspected for holes, embedded wires, ripsor tears, ozone cutting, UV checking and signs of chemical deterioration. For additional information,refer to ASTM F1236, standard guide for visual inspection of electrical protective rubber products.Common Problems to Look forCracking & Cutting: This type of damage iscaused by prolonged folding or compressing.Chemical Attack: This photo shows swellingcaused by oils and petroleum compounds.Contamination: Discard protectors contaminatedwith oil or petroleum compounds.Snags: Damage shown is due to wood ormetal splinters or other sharp objects.UV Checking: Storing in areas exposed toprolonged sunlight causes UV checking.Physical Damage: Rope burns, deep cutsand punctures are cause for rejection.Avoid Folding Electrical Gloves. Thestrain on rubber at a folded point is equalto stretching the glove to twice its length.Avoid Storing Inside Out. Storingreversed gloves strains the rubber severelyand promotes ozone cutting.Embedded Wires: Inspect for embeddedwires or metal shavings that could puncturerubber gloves.Manufacturing DATE CODESG ........ Jan Z ......... 1976 L......... 1988 X......... 2000O ........ Feb A ......... 1977 M ....... 1989 Z......... 2001D ......... March B ......... 1978 N ....... 1990 A ........ 2002H ......... April C ......... 1979 O ....... 1991 B......... 2003E ......... May D......... 1980 P ........ 1992 C ........ 2004L .......... June E ......... 1981 Q ....... 1993 D ........ 2005P ......... July F ......... 1982 R ........ 1994 E......... 2006U ......... Aug G ........ 1983 S ........ 1995 F ......... 2007S ......... Sept H ......... 1984 T ........ 1996 G ........ 2008T ......... Oct I .......... 1985 U ........ 1997 H ........ 2009X ......... Nov J .......... 1986 V ........ 1998 I.......... 2010Z ......... Dec K ......... 1987 W ....... 1999 J ......... 2011IMPORTANT:Rubber Insulating Equipment is foryour personal protection againstelectrical shock.If it is damaged and in use, a seriousinjury may result.Remove damaged equipmentimmediately from the job.SALISBURY www.wh<strong>salisbury</strong>.com


A. Line Hose & CoversCONTENTSB. BlanketsC. Plastic Guards & CoversD. Outage ProtectionE. Gloves & SleevesF. Dielectric BootsG. Insulated JumpersH. Grounding EquipmentI. Hot Sticks & ToolsJ. InsulatorsX. AccessoriesS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401


Line Hose & CoversInsulating Line Hose and Covers - IntroductionLine Hose and Connectors - Conventional SystemProtectors and Covers - Conventional SystemCompatible Covers and Connectors - ChartLine Hose - Extended Lip SU SystemSU System ApplicatorsDead End Protectors - Extended Lip SU SystemInsulator Covers - Extended Lip SU SystemSpecial Covers - Arrester Covers and Cable End CapsS ALISBURYSpecial Covers - Cable End CapsSpecial EquipmentSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401A-1


INSULATING LINE HOSE AND COVERSLeading the industry with overeighty years of Researchand DevelopmentFiled: United States Patent Office, December 21, 1922Serial No 605,340“To all whom it may concern:Be it known that I, Moses B. Salisbury, acitizen of the United States, and a residentof Chicago, in the county of Cookand State of Illinois, have invented an ImprovedProtective Insulating Sleeve, ofwhich the following is a specification. . .”This application, one of hundredsfiled in the US Patent Office for W.H.Salisbury and Co., proved to be themost effective device for protectinglinemen from accidental contact withenergized lines, and is still regardedas indispensable to the electricalindustry today.With over eighty years of researchand development on linemen’sprotective equipment, Salisburyoffers the most comprehensive lineof protection up to 69 kV in theindustry.For a full sized reproduction of this poster contact your local Salisbury representative.All Salisbury Covers and Protective Equipment aredesigned for personal protection only. They are not to beused for mechanical protection.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401A-3


INSULATING LINE HOSE AND COVERSRIB GRIP Locking SystemThe tightest grip in the industry.The self-locking lip Salisbury patentedprevents line hose from coming off theconductor after an installation is complete.But often, as a lineman is working on aninstallation and making adjustments, theangle of connection shifts, causing line hoseand covers to separate. To prevent this,Salisbury developed an ingenious solutionfor ensuring that any two protective deviceswould hold together, regardless of angle andshifting, yet still be easy for a lineman toassemble and take apart.RIB GRIP® construction takes advantageof rubber’s natural tendency to grip andtighten its grip through compression. Bycreating curving rib configurations slit at aspecific angle, two pieces easily sliptogether but resist coming apart. To quicklydisengage the lineman needs only to compressthe rubber on either side.Sectional view of typical insulator covershowing arrangement of ribs. Ribs areengineered to grip the serrations on itscorresponding line hose, regardless of angle.Saw-tooth serrations on the ends of line hoseare angled to make it easy to insert, but resistcoming apart.A row of serrations on both sides ofconnector line hose grips snugly inside thelarge arm of insulator covers.Connector end line hose with rubber ribsthat grasp tightly and hold an adjoininglength of hose.A-4SALISBURY Insulating Line Hose and Covers. www.wh<strong>salisbury</strong>.com


LINE HOSE SELECTION CHARTThe connector, formed at one end, receives andoverlaps the end of an adjoining hose for adistance of 6.5” (165mm). Straight hose is usedto cover taps, jumpers and leads or in positionswhere it connects with the small arm of aninsulator cover or extends to an adjoining connectorend type hose.Use the chart below to determine the maximumconductor diameter recommended for use witheach size line hose. For ease of installation and tominimize the potential of flashover through theoverlapping lips, line hose is always sized largerthan the maximum conductor diameter.Salisbury Line Hose is available in fourASTM D1050 styles, as shown below:Style AClass 2 & 3Straight ConventionalStyle BClass 2 & 3Connector End ConventionalStyle CClass 4Extended Lip StraightStyle DClass 4Extended Lip Connector EndLine Hose Size Selector ChartI.D. ofConductors and Diameters in. (mm)Line Hose 4/0 266,800 336,400 477,000 556,500 795,000 954,000 1,351,500in. (mm) .46 ( 12 ) .609 ( 15.5 ) .677 ( 17 ) .793 ( 20 ) .858 (22) 1.028 ( 26 ) 1.126 ( 29 ) 1.34 ( 35 )1 ( 25 ) 20kV Conventional1 1/4 ( 31 ) 20kV Conventional1 1/2 ( 38 ) 30kV Conventional1 1/2 ( 38 ) 40kV SU System2 ( 51 ) 30kV Conventional2 ( 51 ) 40kV SU System2 1/2 ( 64 ) 30kV Conventional2 1/2 ( 64 ) 40kV SU SystemS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401A-5


LINE HOSE & CONNECTORSCONVENTIONAL SYSTEMConventional Style Line Hose is availablein orange Type II SALCOR®. SALCORremains flexible even in cold weather and itis not damaged by ozone or ultraviolet rays.Each system has Salisbury’s RIB-GRIPLocking System. The straight or connectorend style is available in three sizes: 1” and1.25” I.D. rated at 20kV, Class 2 and 1.5”I.D. rated at 30kV, Class 3. Straight styleSALCOR hose is also available in 2” or 2.5”I.D. rated at Class 3.Conventional Line Hose Connectors aremade from Type II orange SALCOR and canbe used on 1”, 1.25”, or 1.5” I.D. conventionalline hose. To connect 2” and 2.5” I.D.conventional line hose, use the SU SystemConnector.OR150-3OR125-45CORC125A-6SALISBURY Insulating Line Hose and Covers. www.wh<strong>salisbury</strong>.com


LINE HOSE & CONNECTORSCONVENTIONAL SYSTEMCat. No. Class Dimensions I.D. x Length Weight ea.in. ( mm ) lbs. ( kgs )SALCOR® Straight Line HoseOR100-3 2 1” x 3’ ( 25 x 915 ) 3 ( 1.4 )OR100-45 2 1” x 4.5’ ( 25 x 1372 ) 4 ( 1.8 )OR100-6 2 1” x 6’ ( 25 x 1820 ) 5.5 ( 2.5 )OR125-3 2 1.25” x 3’ ( 31.5 x 915 ) 4 ( 1.8 )OR125-45 2 1.25” x 4.5’ ( 31.5 x 1372 ) 6 ( 2.7 )OR125-6 2 1.25” x 6’ ( 31.5 x 1820 ) 7.5 ( 3.4 )OR150-3 3 1.5” x 3’ ( 40 x 915 ) 5 ( 2.3 )OR150-45 3 1.5” x 4.5’ ( 40 x 1372 ) 7 ( 3.2 )OR150-6 3 1.5” x 6’ ( 40 x 1820 ) 9.5 ( 4.3 )OR200-3 3 2” x 3’ ( 50 x 915 ) 5.5 ( 2.5 )OR200-45 3 2” x 4.5’ ( 50 x 1372 ) 8 ( 3.6 )OR200-6 3 2” x 6’ ( 50 x 1820 ) 11 ( 5.0 )OR250-3 3 2.5” x 3’ ( 63 x 915 ) 7 ( 3.2 )OR250-45 3 2.5” x 4.5’ ( 63 x 1372 ) 10.5 ( 4.8 )OR250-6 3 2.5” x 6’ ( 63 x 1820 ) 14 ( 6.4 )SALCOR Connector End Line HoseOR100-3C 2 1” x 3’ ( 25 x 915 ) 3.5 ( 1.6 )OR100-45C 2 1” x 4.5’ ( 25 x 1372 ) 5 ( 2.3 )OR100-6C 2 1” x 6’ ( 25 x 1820 ) 6.5 ( 2.9 )OR125-3C 2 1.25” x 3’ ( 31.5 x 915 ) 4.5 ( 2.0 )OR125-45C 2 1.25” x 4.5’ ( 31.5 x 1372 ) 6.5 ( 2.9 )OR125-6C 2 1.25” x 6’ ( 31.5 x 1820 ) 9 ( 4.1 )OR150-3C 3 1.5” x 3’ ( 40 x 915 ) 6 ( 2.7 )OR150-45C 3 1.5” x 4.5’ ( 40 x 1372 ) 8 ( 3.6 )OR150-6C 3 1.5” x 6’ ( 40 x 1820 ) 9 ( 4.1 )Line Hose ConnectorsORC100 2 1” x 12” ( 25.4 x 305 ) 2.5 ( 1.1 )ORC125 2 1.25” x 12” ( 32 x 305 ) 3.5 ( 1.6 )ORC150 3 1.5” x 12” ( 38 x 305 ) 3 ( 1.4 )All Line Hose complies with current ASTM D1050 specifications.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401A-7


PROTECTORS & COVERSCONVENTIONAL SYSTEMInsulator Covers, in orange, weather resistant Type IISALCOR®, are used with conventional line hose tocover pin-type insulators. All covers feature RIB-GRIPconstruction to lock to the underside of the insulators.The large diameter arm overlaps the small arm of theadjoining cover on double arm constructions whichprovides complete insulation at the joint regardless ofthe varying distance between pins.OKRGOJRGDead End Protectors cover 4.25” and 6” bells orpolymer insulators with a skirt diameter of less than 6”.The protectors are made from orange Type IISALCOR with RIB-GRIP construction. OR101 hasouter ribs that allow it to be used with 2” and 2.5” I.D.Conventional Line Hose when using the UC2 connector.The smaller OR114 may also be used to covertransformer bushings up to 4.75” in diameter. OR124can cover polymer insulators up to 4.75” in diameterand 25” overall length including hardware. ReplacementStraps are available.OR101OR114OFRGN36N24To work on live lines safely, conductors encased in aline hose should never be placed directly on a crossarm. Orange Type II SALCOR Cross Arm Coversreduce electrical stresses on line hose or jumpers.Cross Arm Covers fit standard cross arm pin spacingand each unit has interior ribs to minimize shifting onthe arm.OR124Flexible Cutout Covers, made from Type II orangeSALCOR corona resistant elastomer, can be used foroverhead cutouts as well as for underground padmountapplications. Cutout Covers comply with thecurrent ASTM D1049 specifications.1451186CC24A-8SALISBURY Insulating Line Hose and Covers. www.wh<strong>salisbury</strong>.com


PROTECTORS & COVERSCONVENTIONAL SYSTEMCat. No. Class Description Overall Dimensions Weight ea.in (mm) in ( mm ) lbs. ( kgs )f o r u s e w i t hINSULATOR COVERS Insulator Class Line Hose SizeOFRG 2 55-1/2/3 1” (25.4) 14.5” x 5” ( 368 x 127 ) 5 ( 2.3 )OJRG 2 55-4 1” ( 25.4 ) 16” x 6.5” ( 406 x 165 ) 6 ( 2.7 )OKRG 3 55-5 1.25”, 1.5” ( 32 , 38 ) 16” x 8” ( 406 x 203 ) 7 ( 3.2 )f o r u s e w i t hDEAD END PROTECTORS Bell Size Line Hose SizeOR101 2 2-6”( 152.4 ) 1” ( 25.4 ) 6.5” x 23” ( 165 x 584 ) 8 ( 3.6 )OR114 3 1-4.25” ( 108 ) 1.5” ( 38 ) 4.75” x 14” ( 121 x 356 ) 3 ( 1.4 )OR124 3 2-4.25” ( 108 ) 15” ( 38 ) 4.75” x 29” ( 121 x 737 ) 6 ( 2.7 )CROSS ARM COVERS Use on Cross Arms up to145 2 4” x 4.5” ( 102 x 114 ) 14.5” x 4.63” x 4.15” ( 368 x 117 x 105 ) 3 ( 1.4 )1186 4 5.5” x 6” ( 140 x 152 ) 17.0” x 6.0” x 5.5” ( 432 x 152 x 140 ) 5 ( 2.3 )CUTOUT COVERSCC24 2 24” x 15” x 3.5” ( 600 x 376 x 88 ) 4 ( 1.8 )CC30 4 30” x 20” x 7” ( 750 x 500 x 175 ) 10 ( 4.5 )REPLACEMENT STRAPSN24 For 114 & 124 Series .75 x 30 ( 18 x 588 ) 2 oz. ( 56.7 g )N36 For 101 Series .75 x 36 ( 18 x 882 ) 2 oz. ( 56.7 g )All covers comply with current ASTM D1049 specifications.Small ArmPut on with a firmdownward pressure.Large ArmLarge ArmRemove by “rollingoff” sideways.Small ArmOn double arm poles thelarger extending arm of theone hood fits easily over thesmall arm of the hood on theopposite insulator.Attaching the hoods toopposite insulators ondouble arms.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401A-9


COMPATIBLE COVERS AND CONNECTORSFOR LINE HOSE & EXTENDED LIP SYSTEMSUse this chart to match compatibleLine Hose and covers.Line Hose I.D. in. / mmCat. No. 1” / 25.4 1.25” / 32 1.5” / 38 2” / 51 2.5” / 63.5OFRG !OJRG !OKRG ! !ORC100 !ORC125 !ORC150 !OR134 ! !PTHL ! !PTHS !MRG ! !UC2 ! !OR101 ! ! ! !OR114 !OR124 !U110 !U106 !! = UC-2 Connector must be usedA-10SALISBURY Insulating Line Hose and Covers. www.wh<strong>salisbury</strong>.com


LINE HOSEEXTENDED LIP SU SYSTEMThe Extended Lip SU System is the onlycomplete flexible cover-up available foruse on voltages through 34.5kV. Extremelyversatile, it may be installed byhand, wearing rubber insulating gloves,from an insulated aerialdevice or platform, or withhot sticks using the SUapplicators.Manufactured from superiorSALCOR® Type II elastomer, it isresistent to the effects of ozone andultraviolet deterioration. It remains flexibleeven at sub-zero temperatures.SU150-3CSU150-45Salisbury’s RIB GRIP® constructionsecurely interlocks with its correspondingcovers and connectors. Tapered lipsfacilitate easy starting on the conductors. Thecontour cut ends accommodate the skirts ofpin type insulators and permit the hose to coverthe line snug to a saddle or clamp.Available as Straight Line Hose or with aConnector End for easier connection ofline hose and covers. A lifting eye ismolded on the connector end for removalwith hot sticks. Line hose is also availablewith the #2323 Shot Gun Eye Assembly.Just add a suffix of “E” to the catalognumber to order the #2323 Shot GunAssembly installed on the hose or orderthe #2323 separately.SU System Connectors are made fromorange SALCOR Type II. RIB-GRIPconstruction is used to ensure a stronglock to the straight lengths of SU SystemLine Hose and covers. The UC2 is used toconnect Extended Lip Hose to PTHL andLRG Insulator Covers, OR134 Dead EndProtectors, and 2” (51mm) and 2.5”(64mm) SU System and ConventionalLine Hose.Cat. No. Dimensions -- in. ( mm ) Weight ea.I.D. Length lbs. ( kgs )STRAIGHT LINE HOSE Class 4, Type IISU150-3 1.5” ( 38 ) 3’ ( 915 ) 6 ( 2.7 )SU150-45 1.5” ( 38 ) 4.5’ ( 1372 ) 8.5 ( 3.8 )SU150-6 1.5” ( 38 ) 6’ ( 1829 ) 12 ( 5.4 )SU200-3 2” ( 51 ) 3’ ( 915 ) 6 ( 2.7 )SU200-45 2” ( 51 ) 4.5’ ( 1372 ) 10 ( 4.5 )SU200-6 2” ( 51 ) 6’ ( 1829 ) 14 ( 6.4 )SU250-3 2.5” ( 63.5 ) 3’ ( 915 ) 7 ( 3.2 )SU250-45 2.5” ( 63.5 ) 4.5’ ( 1372 ) 11 ( 5.0 )SU250-6 2.5” ( 63.5 ) 6’ ( 1829 ) 15 ( 6.8 )CONNECTOR END LINE HOSE Class 4, Type IISU150-3C 1.5” ( 38 ) 3’ ( 915 ) 7 ( 3.2 )SU150-45C 1.5” ( 38 ) 4.5’ ( 1372 ) 9 ( 4.1 )SU150-6C 1.5” ( 38 ) 6’ ( 1829 ) 12 ( 5.4 )SU SYSTEM CONNECTORS Class 4, Type IILength x Height Use w/ Line HoseUC 10.5 x 6 ( 263 x 150 ) 1.5 ( 40 ) 2 ( .9 )UC2 10.5 x 7.75 ( 263 x 194 ) 2&2.5 ( 51&64 ) 3 ( 1.4 )Add Suffix “E” to order with #2323 Shot Gun Eye AssemblyComplies with current ASTM D1050 specifications.UC and UC2 Comply with ASTM 1049 specifications.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401UCA-11


SU SYSTEM APPLICATORSThe Extended Lip SU System maybe installed by using rubber glovesor hot sticks on distributionvoltages 34.5kV.The Shot Gun Eye Assemblies forthe SU System equipment may bepurchased separately for installationon the appropriate cover-updevice. The addition of these eyeassemblies enable all SU Systemequipment to be easily handledwith a standard Shot Gun.2323 Shot Gun Assembly2323 Shot Gun Assembly allows easy installation 2323 Shot Gun Assembly attaches easily to SU SystemsCat. No. Description For Use w/ Weight ea.Hot Stick Style lbs. ( kgs )2323 Eye Assembly for SU Hose & OR134 Shot Gun 1 ( .4 )2359 Eye Assembly for SU System Insulator Covers Shot Gun .5 ( .2 )2340 Eye Assembly for SU System D.E. Protectors Shot Gun .5 ( .2 )A-12SALISBURY Insulating Line Hose and Covers. www.wh<strong>salisbury</strong>.com


DEAD END PROTECTORSEXTENDED LIP SU SYSTEMDead End Protectors quickly coverdead end bells providing completeelectrical protection for Class 3 and 4applications.OR134Easily installed and removed from aninsulated platform or aerial device withrubber gloves or SU System Applicators.All styles have RIB-GRIP®construction to interlock with1.5” (38mm) I.D. line hose.The Class 3 U106 and U110must be used with ConnectorEnd style line hose or separateLine Hose Connectors. TheClass 4 OR134 acceptsStraight Line Hose. The outerribs interlock with 2” and 2.5”I.D. line hose when the UC2SU System Connector is used.OR134EU110Cat. No. ASTM Fits Bell Size Dimensions in. ( mm ) Color Weight ea.Class / Type in. ( mm ) I.D. body Overall Length lbs. ( kgs )DEAD END PROTECTORSOR134 4 / II 3-4.25 ( 108 ) 5 ( 127 ) 37 ( 940 ) Orange 13 ( 6 )OR134E 4 / 11 3-4.25 ( 108 ) 5 ( 127 ) 37 ( 940 ) Orange 14 ( 6.4 )U106 3 / II 2-6 ( 152 ) 7 ( 178 ) 28.5 ( 724 ) Black 6 ( 2.7 )U110 3 / II 2-10 ( 254 ) 10.5 ( 267 ) 28.5 ( 724 ) Black 10 ( 4.5 )Add Suffix “E” to order with #2323 Shot Gun Eye AssemblyAll Protectors comply with current ASTM D1049 specifications.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401A-13


INSULATOR COVERSEXTENDED LIP SU SYSTEMThe UH Pin-Type Cover covers insulatorsup to ANSI Class 5. The sides are cut to beused on small insulators without resting onthe crossarm. When covering a 7” diameterinsulator on a double arm construction, theends of the cover will meet flush on 10.5”pin centers.UHThe LRG SU System Pin-Type Cover fitsinsulators 10.5” (267mm) in diameter and isused with 2.5” (64mm) Class 4 Extended LipSU System Line Hose. Always use clamppins to secure the device into position.Pinning rings have been placed on thecover’s arms to prevent separation.LRGPost-Type Insulator Covers interlock with1.5” (38mm) Class 4 Extended Lip SUSystem or Conventional Line Hose. ThePTHS for insulators up to 12” (305mm) andthe PTHL for insulators up to 16” (406mm)in height. The PTHL cover also has externalribs on the ears which secures 2.5” (64mm)I.D. line hose. Always use clamp pins tosecure the device into position.PTHSThe Class 4 MRG Universal Cover coverspin-type insulators through 8.5” (216mm)diameter and 13.8kV post-type insulators. Atrim bead permits use on both 35kV and15kV crossarm construction.PTHLThe USC is a lightweight cover made fromorange Type II SALCOR that can beinstalled using rubber gloves or a hot stick.The USC also feature RIB-GRIP constructionand is meant to be used with ExtendedLip SU Systems or Conventional Line Hose.All covers are made from orange SALCOR®and feature RIB-GRIP® Construction. Theycan be installed with a hot stick or rubbergloves. All covers comply with ASTM 1049specifications.USCMRGUSC (side view)A-14SALISBURY Insulating Line Hose and Covers. www.wh<strong>salisbury</strong>.com


INSULATOR COVERSEXTENDED LIP SU SYSTEMCat. ASTM Fits Line Hose Fits Insul. Overall Dimensions--in. (mm) Weight ea.No Class / Type in ( mm ) Max Dia in (mm) I.D. body Height lbs. ( kgs )PIN TYPE Insulator CoversLRG 4 / II 2.5 ( 63 ) 10.5 ( 263 ) 12 ( 305 ) 16 ( 400 ) 8 ( 3.6 )UH 3 / II 1.5 ( 40 ) 7 ( 175 ) 7.5 ( 184 ) 12 ( 300 ) 6 ( 4.4 )MRG 4 / II 1.5-2.5 ( 40-63 ) 8.5 ( 213 ) 9 ( 221 ) 12.25 ( 306 ) 7 ( 3.2 )POST TYPE Insulator CoversPTHL 4 / II 1.5-2.5 ( 40-63 ) 6.5 ( 163 ) 7 ( 172 ) 16 ( 400 ) 8 ( 3.6 )PTHS 4 / II 1.5 ( 40 ) 7 ( 175 ) 7.5 ( 184 ) 12 ( 300 ) 4 ( 1.8 )USC 4 / II 1.5 ( 40 ) 14 ( 263 ) 15.5 ( 388 ) 5 ( 2.3 )Add Suffix “E” to order with 2359 Shot Gun Eye AssemblyAll Covers comply with current ASTM D1049 specifications.Pin Type Insulator Cover - LRG or MRGLine Hose is insertedin the ears of the cover.Post Type Insulator CoverPTHL 2.5” (64mm) Line Hose heldin place with UC2 Connector.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401A-15


SPECIAL COVERSARRESTER COVERS & CABLE END CAPSCable End Caps can be applied with rubbergloves or a hot stick. They are used on highvoltage distribution cable ends found in vaults,cubicles and substations when cable remainsenergized during work. Cable End Caps aremade from Type II orange SALCOR®.The Slotted Cable End Cap 636S can beinstalled directly over an energized silver-sandfuse, bushing or elbow and cable. A 3” hole at thetop allows room for the insulator, elbow orterminator cable. Special lengths or slots can bemade by contacting your local Salisbury representative.Lightning Arrester Covers are made from TypeII orange SALCOR . The slot allows the cap to fitdirectly over the energized lightning arrestor andthe line connection.C8536536A636ACat. No. ASTM Type Dimensions in. ( mm ) Weight ea.Class I.D. x Length lbs.( kgs)CABLE END CAPSC8 2 II 2.5 x 9 ( 63.5 x 229 ) 3 ( 1.4 )536 4 II 4.75 x 37 ( 119 x 925 ) 7 ( 3.3 )636 4 II 5.88 x 37 ( 147 x 925 ) 9 ( 4.1 )636S 4 II 5.88 x 37 ( 147 x 925 ) 9 ( 4.1 )LIGHTNING ARRESTER COVERS536A 4 II 4.5 x 15 ( 113 x 375 ) 3 ( 1.4 )636A 4 II 5.5 x 22 ( 138 x 550 ) 5 ( 2.3 )All Covers comply with current ASTM D1049 specifications.A-16SALISBURY Insulating Line Hose and Covers. www.wh<strong>salisbury</strong>.com


SPECIAL COVERSCABLE END CAPSCable End Caps can be appliedwith rubber gloves. They are usedon high voltage distribution cableends found in vaults, cubicles andsubstations when cable remainsenergized during work. Cable EndCaps are made from Type II orangeSALCOR® and have a minimumwall thickness of .25”.Self-securing Cable End Caps forUnderground Distribution are madefrom Type II Class 2 orangeSALCOR and are rated at 20kV.They keep moisture and contaminationoff trimmed cable ends. Theself-securing slot keeps the cablelocked safely inside the end cap.178117173173Cat. No. Class Type Dimensions in. ( mm ) For use w/ Cable Size Weight ea.I.D. x Length lbs. ( kgs )173 2 II .81” x 6” ( 21 x 152 ) #4 to #4/0 AWG .25 ( .1 )117 2 II 1.38” x 10” ( 35 x 254 ) #4/0 to 500 MCM .50 ( .23 )177 2 II 2.25” x 12” ( 57 x 305 ) 350 to 750 MCM .75 ( .35 )178 2 II 3.19” x 16” ( 81 x 406 ) 800 to 1000 MCM 1.5 ( .7 )All Covers comply with current ASTM D1049 specifications.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401A-17


BLANKETSInsulating Blankets - Eyelet StyleInsulating Blankets - Slotted StyleInsulating Blankets - Without EyeletsLo-Volt and Primary Blankets - With and Without Hook & PileBlanket Accessories - FastenersBlanket Accessories - Clamp PinsBlankets Accessories - StorageSwitchboard MattingS ALISBURYArc Suppression BlanketRoll BlanketsSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401B-1


Only Salisbury formulates compounds, mixes,molds and tests blankets in our ownISO 9000:2001 registered facilities.General Care & Inspection of Salisbury Rubber GoodsType I natural (non-ozone resistant) and Type II SALCOR® synthetic rubber(resistant to ozone) both provide electrical workers with the highest level of electricalinsulating protection. However, in order to maintain this level of protection andensure long life, it is essential that rubber goods are properly cared for. Before eachuse, rubber goods should be visually inspected for holes, embedded wires, rips ortears, ozone cutting, UV checking and signs of chemical deterioration. For additionalinformation, refer to ASTM F1236, standard guide for visual inspection of electricalprotective rubber products.B-2SALISBURY Insulating Blankets. www.wh<strong>salisbury</strong>.com


INSULATING BLANKETSEyelet StyleEyelet Style Insulating Blanketswere designed to be easily securedin place by using blanket pins, SnapButtons or Ty-Straps (available onpage B-7).Salisbury Insulating Blankets,compliant with ASTM D1048specifications, are flexible andfeature a reinforced beaded edgeand eyelets for added strength andtear-resistance.400E (27 x 36)13 (22 x 22)1900E (46 x 46)900E (36 x 36)Cat. Eyelets ASTM Class / Type / Size Color Weight ea.No. Proof Test Volt. Material in. ( mm ) lbs. ( kgs)12 28 2 / 20kV I / Natural 22 x 22 ( 559 x 559 ) Black 3 ( 1.4 )13 28 4 / 40kV II / SALCOR® 22 x 22 ( 559 x 559 ) Orange 3 ( 1.4 )13-1 28 4 / 40kV II / SALCOR 22 x 22 ( 559 x 559 ) Black 3 ( 1.4 )13-10 10 4 / 40kV II / SALCOR 22 x 22 ( 559 x 559 ) Orange 3 ( 1.4 )400E 6 2 / 20kV I / Natural 27 x 36 ( 686 x 914 ) Black 6 ( 2.3 )1000E 6 4 / 40kV II / SALCOR 27 x 36 ( 686 x 914 ) Orange 6 ( 2.3 )1001E 6 4 / 40kV II / SALCOR 27 x 36 ( 686 x 914 ) Black 6 ( 2.3 )300E 6 2 / 20kV I / Natural 36 x 36 ( 914 x 914 ) Black 8 ( 3.6 )900E 6 4 / 40kV II / SALCOR 36 x 36 ( 914 x 914 ) Orange 8 ( 3.6 )901E 6 4 / 40kV II / SALCOR 36 x 36 ( 914 x 914 ) Black 8 ( 3.6 )900E12 12 4 / 40kV II / SALCOR 36 x 36 ( 914 x 914 ) Orange 8 ( 3.6 )1500 28 2 / 20kV I / Natural 36 x 36 ( 914 x 914 ) Black 8 ( 3.6 )1700 28 4 / 40kV II / SALCOR 36 x 36 ( 914 x 914 ) Orange 8 ( 3.6 )1900E 6 4 / 40kV II / SALCOR 46 x 46 ( 1168 x 1168 ) Orange 12 ( 5.4 )All blankets comply with current ASTM D1048 specifications.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401B-3


INSULATING BLANKETSSlotted Style1301 (36 x 36)Slotted Style Insulating Blanketsare designed for increased versatility andflexibility in special cover-up situations.Use for covering ridge pins, cross armswith insulators or any place a wire, pinor projection interferes with properplacement of other cover-up devices.Three sizes are available withreinforced beaded edges and reinforcedeyelets which can be secured withblanket pins, Snap Buttons or Ty-straps(available on Page 7). Our 36”(914mm)slotted blanket is also available with 2”(51mm) or 4.5”(114mm) center holesand with hook and pile (Zip Style). Our46”(1168mm) slotted blanket featuresextra thickness at the end of the slot foradded strength.1300 (36 x 36)15 (22 x 22)Cat. Eyelets ASTM Class / Type / Size Color Weight ea.No. Proof Test Volt. Material in. ( mm ) lbs. ( kgs )14 28 2 / 20kV I / Natural 22 x 22 ( 559 x 559 ) Black 2.5 ( 1.1 )15 28 4 / 40kV II / SALCOR® 22 x 22 ( 559 x 559 ) Orange 2.5 ( 1.1)15-1 28 4 / 40kV II / SALCOR 22 x 22 ( 559 x 559 ) Black 2.5 ( 1.1 )1100 28 2 / 20kV I / Natural 36 x 36 ( 914 x 914 ) Black 7 ( 3.2 )1300 28 4 / 40kV II / SALCOR 36 x 36 ( 914 x 914 ) Orange 7 ( 3.2 )1301 28 4 / 40kV II / SALCOR 36 x 36 ( 914 x 914 ) Black 7 ( 3.2 )1302 2” hole 4 / 40kV II / SALCOR 36 x 36 ( 914 x 914 ) Orange 7 ( 3.2 )1304 4.5” hole 4 / 40kV II / SALCOR 36 x 36 ( 914 x 914 ) Orange 7 ( 3.2 )1300V Zip Style 4 / 40kV II / SALCOR 36 x 36 ( 914 x 914 ) Orange 7 ( 3.2 )1400E 6 2 / 20kV I / Natural 46 x 46 ( 1168 x 1168 ) Black 12 ( 5.4 )1800E 10 4 / 40kV II / SALCOR 46 x 46 ( 1168 x 1168 ) Orange 11 ( 5 )All blankets comply with current ASTM D1048 specifications.B-4SALISBURY Insulating Blankets. www.wh<strong>salisbury</strong>.com


INSULATING BLANKETSWithout EyeletsSalisbury Insulating Blanketswithout Eyelets are available inClass 2 and Class 4 in two typesof material: Type I natural rubber,and Type II SALCOR®, which isa highly flexible, corona-resistantpolymer with excellent aging andweathering qualities.300 (36 x 36)Salisbury insulating blanketsfeature a reinforced beaded edgefor added strength and tearresistance.1900 (46 x 46)1000 (27x 36)186 (18 x 36)Cat. No. ASTM Class / Type / Size Color Weight ea.Proof Test Volt. Material in. ( mm ) lbs. ( kgs )186 4 / 40kV II / SALCOR 18 x 36 ( 457 x 914 ) Orange 3.5 ( 7.7 )1000 4 / 40kV II / SALCOR 27 x 36 ( 685 x 914 ) Orange 6 ( 2.3 )300 2 / 20kV I / Natural 36 x 36 ( 914 x 914 ) Black 8 ( 3.6 )1900 4 / 40kV II / SALCOR 46 x 46 ( 1168 x 1168 ) Orange 12 ( 5.4 )All blankets comply with current ASTM D1048 specifications.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401B-5


LO-VOLT & PRIMARY BLANKETSWith & without hook and pileLo-Voltage Insulating Blanketsand Primary Insulating Blanketsare made of Type II SALCOR®rubber. Insulating blankets areavailable with or without R hook andpile (Zip) or Plain style, as noted inthe chart below.Covering energized equipment iseasier than ever using Salisbury’sZip-On blankets. Our Zip-On Style(Zip) features one-inch wide stripsof hook and pile double stitched tothe blanket with nylon thread, soinstallation and removal is safe andfast. Zip-On blankets can be manufacturedto fit special requirements.Contact your Salisbury representativefor more information.1212YLV183OS1212YLVNVCat. Style ASTM Class / Type / Size Color Weight ea.No. Proof Test Volt. Material in. ( mm ) lbs. ( kgs )1212YLV Zip 0 / 5000V II / SALCOR 12x12 ( 305x305 ) Yellow 1 ( .45 )1212YLVNV Plain 0 / 5000V II / SALCOR 12x12 ( 305x305 ) Yellow 1 ( .45 )1818YLV Zip 0 / 5000V II / SALCOR 18x18 ( 457x457 ) Yellow 1.1 ( .48 )1818YLVNV Plain 0 / 5000V II / SALCOR 18x18 ( 457x457 ) Yellow 1.1 ( .48 )1836YLV Zip 0 / 5000V II / SALCOR 18x36 ( 457x914 ) Yellow 1.5 ( .68 )1836YLVNV Plain 0 / 5000V II / SALCOR 18x36 ( 457x914 ) Yellow 1.5 ( .68 )3636YLV Zip 0 / 5000V II / SALCOR 36x36 ( 914x914 ) Yellow 2.2 ( 1.0 )3636YLVNV Plain 0 / 5000V II / SALCOR 36x36 ( 914x914 ) Yellow 2.2 ( 1.0 )Installing a Zip-On Blanket183OS Zip 4 / 40kV II / SALCOR 18x36 ( 457x914 ) Orange 3.5 ( 1.6 )1000EV Zip 4 / 40kV II / SALCOR 27x36 ( 686x914 ) Orange 8.1 ( 3.7 )900EV Zip 4 / 40kV II / SALCOR 36x36 ( 914x914 ) Orange 8.5 ( 3.9 )1300V Zip/Slotted 4 / 40kV II / SALCOR 36x36 ( 914x914 ) Orange 7 ( 3.2 )All blankets comply with current ASTM D1048 specifications.B-6SALISBURY Insulating Blankets. www.wh<strong>salisbury</strong>.com


BLANKET ACCESSORIESFastenersBlanket Buttons are designed to secureeyelet-style insulating blankets. The B1button, made of yellow plastic, snapsthrough the eyelet with thumb pressure onthe large head. The bright Rorange polystyreneB23 two-way buttons are inserted intothe eyelets for use with a shotgun clampstick or standard-duty switch stick.B1Magnetic Blanket Buttons are designedfor use in eyelets of insulating blanketswhen covering energized portions in hardto-coverareas like pad mounts, cubicles,switchboards and substations. Four permanentfloating magnets are mounted betweennickel-plated steel plates. May be appliedmanually, wearing rubber gloves, or with ashot-gun stick.Ty-Straps are 14” (356mm) and 30”(762mm) long and made of 1 1/2” (38mm)wide strips of rubber with hook and pilefasteners affixed to each end. The linemansimply wraps the Ty-Strap around thepositioned blanket and presses the hook andpile ends together. Contact your localSalisbury representative for custom lengthTy-Straps.B23MB6TY14Cat. No. Description Weight ea. lbs. ( kgs )B1 Snap-Button, Yellow 1 oz. ( .03 )B23 Two-Way Button, Orange 1 oz. ( .03 )MB6 Magnetic Blanket Button 7 oz. ( .2 )TY14 Ty-Straps, 14” ( 356mm ) long 2 oz. ( .06 )TY30 Ty-Straps, 30” ( 762mm ) long 4 oz. ( .12 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401B-7


BLANKET ACCESSORIESClamp PinsIn addition to other uses in the utilityindustry, Blanket Clamp Pins can beeffectively used to hold insulatingblankets in place. Springs are used fortension while extra holes in the bodyof the pin are used to grip conductorsand prevent line hose from sliding(see photo below).20YN20Blanket pins are made of fiberglassreinforced nylon or sliver-free hardwoods.Most pins have molded rubbertips to increase slip resistance.212526Clamp Pins help line hose from slippingHS21Cat. No. & Description Length Jaw Opening Weight ea.in. ( mm ) in. ( mm ) lbs. ( kgs )20 Wood w/ pin boots 8.5 ( 216 ) 4.75 ( 121 ) .33 ( .15 )YN20 Wood w/ Sure grip 8.5 ( 216 ) 4.75 ( 121 ) .33 ( .15 )21 Nylon w/ pin boots 9.5 ( 241 ) 5 ( 127 ) .25 ( .11 )25 Wood w/o pin boots 7 ( 178 ) 1.6 ( 41 ) .25 ( .11 )26 Wood w/ pin boots 10 ( 254 ) 7 ( 178 ) .5 ( .23 )HS21 Nylon w/ pin boots 9.5 ( 241 ) 5 ( 127 ) .25 ( .11 )applied with Shot Gun StickB-8SALISBURY Insulating Blankets. www.wh<strong>salisbury</strong>.com


BLANKET ACCESSORIESStorageBlanket Canisters-molded in brightorange, hi-impact polyethylene-protectinsulating blankets when not in use. Atight-fitting cap is secured to the canisterwith polypropylene rope.Blanket Roll Ups provide a safe andconvenient means for protecting blanketsfrom damage while in transport orstorage. Ruggedly constructed of 12 oz.water resistant cotton duck with 12” sideflaps to confine the blankets into positionand prevent damage to the edges. Twoheavy web straps with buckles close theroll-up, and a double web cross strapserves as a carrying handle.P2P4P6STORAGE TIPS: When more than oneblanket is stored, the most convenientmethod of loading is to roll and insert eachblanket into the canister independently. Asingle blanket can then be removed withoutremoving the others. For maximum usefullife, never fold, crease or compressinsulating blankets while in storage.22Cat. No. Description Fits Blanket Dimensions Capacity Weight ea.Max Size in.( mm ) in. ( mm ) lbs. ( kgs )P2 Canister 36 ( 914 ) 5 x 37 ( 127 x 940 ) 1-2 blankets 2 ( .9 )P3 Canister 36 ( 914 ) 6 x 37 ( 152 x 940 ) 1-3 blankets 3 ( 1.4 )P4 Canister 36 ( 914 ) 7 x 37 ( 178 x 940 ) 1-4 blankets 3.5 ( 1.6 )P6 Canister 36 ( 914 ) 9 x 37 ( 229 x 940 ) 1-6 blankets 5 ( 2.3 )P3-47 Canister 46 ( 1168 ) 6 x 47 ( 152 x 1194 ) 1-2 blankets 4 ( 1.8 )22 Roll-up 22 ( 559 ) 41 x 33 ( 1041 x 838 ) 1-4 blankets 1.5 ( .68 )36 Roll-up (cloth) 36 ( 914 ) or 46 ( 1168 ) 54 x 46 ( 1371 x 1168 ) 1-4 blankets 2.5 ( 1.1 )46 Roll-up (vinyl) 36 ( 914 ) or 46 ( 1168 ) 54 x 46 ( 1371 x 1168 ) 1-4 blankets 4 ( 1.8 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401B-9


SWITCHBOARD MATTINGSwitchboard Matting is placed permanentlyplaced in front of switchgear, motor controlcenters and other high voltage apparatus toprovide personal protection for workers. It isalso used when tending take-up and pay outreels and when adding or replacing conductors.Made from high quality Type II rubber,Class 2 matting is 1/4” (6.4mm) thick and istested to 20kV, and Class 4 matting is 1/2”thick and tested to 40kV. Both Classes ofmatting comply with ASTM D178, Class 2and Class 4 specifications. The corrugatedsurface acts as a safety tread while reducingthe possibility of metal particles becomingembedded. Class 2 Switchboard matting isavailable in 25 yard rolls or custom cut tospecified lengths, while Class 4 matting issold in 20 yard rolls only.Maximum Use Voltage Class 2, 17,000 volts,Class 4, 36000 volts.M24-2367Matting Cross-SectionURD/Switchboard Blanket, 84” x 36”,is ideal whenever a large insulating barrier isrequired to protect electrical workers frombrush contact with live electrical apparatus.The URD has 10 eyelets and is made fromred Type II SALCOR®, proof tested to 20kV. The R96 canvas/roll-up carrier is recommendedfor a ground barrier when URD 367is used outdoors.R96Cat. No. Dimensions Weight per yardin. mm lbs. kgsNEWSWITCHBOARD MATTING - CLASS 2M24-2 1/4 x 24 6 x 610 9 4.1M30-2 1/4 x 30 6 x 762 12 5.4M36-2 1/4 x 36 6 x 914 15 6.8M48-2 1/4 x 48 6 x 1219 18 8.2SWITCHBOARD MATTING - CLASS 4M36-4* 1/2 x 36” x 60 feet long 12 x 914 mm x 18.3 m long 684 307.8All switchboard matting comply with current ASTM D178 standards*Sold in full rolls only.URD BLANKETWeight ea.367 84 x 36 1234 x 914 19 41.8R96 Carrier Canvas Roll-Up / Ground Barrier 3.5 1.6B-10SALISBURY Insulating Blankets. www.wh<strong>salisbury</strong>.com


ARC SUPPRESSION BLANKETThe Arc Suppression Blanket is usedas a barrier for protection from theexplosive and incendiary effects ofelectrical arcs and flashes. Thesehazardous electrical discharges can becaused by faults in cables, in cablesplices and joints, and at transformerterminals, or they may be generated bythe operation of switch gear, circuitbreakers and lightning arrestors. Theblanket can be used for worker protectionin underground vaults, switchyards,and other locations where electricalequipment poses a risk of exposure toexplosive electrical discharges.Because of the unpredictability ofelectrical discharges, the Arc SuppressionBlanket may not totally contain arcsand flashes, but only reduce or limitexplosive and incendiary effects. In suchcases, injuries may still occur, evenwhen the blanket is properly used.ARC48Cat. No. Dimensions Description Weight ea.in. ( mm ) lbs. ( kgs )ARC45 48 x 60 ( 1219 x 1524 ) w/ P-4 Canister 7.5 ( 3.4 )ARC48 48 x 96 ( 1219 x 2438 ) w/ P-4 Canister 9 ( 4.1 )21655 48 x 60 ( 1219 x 1524 ) Blanket Only 4.5 ( 2 )21656 48 x 96 ( 1219 x 2438 ) Blanket Only 6 ( 2.7 )P4 54 x 46 ( 1371 x 1168 ) Canister 3 ( 1.4 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401B-11


ROLL BLANKETSSalisbury has gone to great lengths to protect workers from lovoltageelectrical hazards, by now offering insulating blanketmaterial on a roll. Salisbury’s insulating Roll Blankets,made from a high strength fabric reinforced Type IIrubber, allow workers to custom-cut the blanket to fiteach application at the job site. This minimizes thenumber of different lo-voltage blankets sizes and shapesthat would otherwise need to be carries from job to job.Salisbury’s insulating Type II rubber Roll Blankets, meetsNEW ASTM F2320 standards.Salisbury’s Roll Blanket lineincludes a Class I (7,500v)Clear PVC material thatpermits complete visibility, yetprovides the necessaryinsulating properties meetingASTM F1742 standards.NEWRLB1Convenient Size RollsFlexible and Easy to CutLow CostFlame Resistant - Self ExtinguishingType II - Ozone and Ultra Violet ResistantFabric Reinforced - Puncture and Tear ResistantFlexible to -40°FHighly Visible ColorsRoll Blankets can be easily cut to size and fitfor customized applications to each job.RLBPVC1All classes of Roll Blankets are easy to cut, and flexible to-40°F/C. Highly puncture and tear resistant, each class ofblanket is also flame (self-extinguishing), oil, and ozoneresistant. Each comes in a convenient 36” wide roll, 30 feetin length in unique colors making it easy to identify andhighly visible in the work area.Cat. No. Description Max Use Dimensions Weight ea.ft ( m ) lbs. ( kgs )RLB00 Class 00 Maroon 500 VAC 3’ x 30’ ( .9 x 9 ) 20 ( 9 )RLB0 Class 0 Yellow 1000 VAC 3’ x 30’ ( .9 x 9 ) 26 ( 11.8 )RLB1 Class 1 Yellow / Orange 7500 VAC 3’ x 30’ ( .9 x 9 ) 36 ( 16.4 )RLBPVC1 Class 1 Clear 7500 VAC 3’ x 30’ ( .9 x 9 ) 36 ( 16.4 )B-12SALISBURY Insulating Blankets. www.wh<strong>salisbury</strong>.com


INSULATING PLASTIC GUARDS & COVERSInsulating Plastic Guards and Covers - IntroductionAir Gap® Pole GuardsVersa® and Link® GuardsLightweight Conductor CoversCrossarm GuardsSubstation Cover-Up - Bus GuardsSubstation Cover-Up - Switch Jaw Guard & BarrierGuard and Cover AccessoriesS ALISBURYGuard and Cover AccessoriesSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401C-1


INSULATING PLASTIC GUARDS AND COVERSGuards and Covers are intended forbrush contact applications. All guardscan be coupled together to cover anylength required.Guards and covers are available inthree different grades: Grade 1 withhot stick handles attached forapplication and removal and Grade 2with eye fittings for standard shotgunsticks and Grade 3 without eyefittings. Guards are designed to nestwithin each other for storage.The guards and covers are madefrom two different orange thermoplastics:Type I is a ABS standardcold weather high impact plastic andType III is a PPO premium plasticthat offers advantages in tensile andimpact strength, hardness, UVstability, and flame resistance.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401C-3


AIR GAP® POLE GUARDSPole Guards are installed before setting new poles toguard against accidental line contact. They also guardagainst pole contacts by personnel working in insulatingaerial buckets or on platforms. Pole Guards aremade from orange thermoplastic, Type I ABS, coldweather, high impact plastic. Salisbury Pole Guardsfeature the unique Air Gap design. Uniformly spaceddimples minimize the amount of surface area contactingthe pole. This provides added insulation to keepelectrical leakage to a minimum. When two pole guardsare used to cover longer lengths, the Air Gap dimplesnest together “locking” the two together with ampleoverlap. This is an exclusive feature to SalisburyPole Guards. The Air Gap design also allows for airflow between it and the pole minimizing moisturecondensation and contamination buildup.Pole Guards should be used for brush contact. Theopening should face away from possible line contacts,whenever possible. Pole Guards should be storedindoors to avoid prolonged exposure to UV rays andshould be cleaned with a warm detergent solution.28562486Bonded HandleCat. No. Length Dia. Handle Class Weight ea.ft. ( m ) in. ( mm ) lbs. ( kgs )2851 1’ ( .3 ) 3.3 ( 1.5 )2852 2’ ( .61 ) 6.3 ( 2.9 )2853 3’ ( .92 ) 6” ( 152.4 ) Drilled 4 9.0 ( 4.1 )2854 4’ ( 1.2 ) 11.0 ( 5.0 )2856 6’ ( 1.8 ) 17.0 ( 7.7 )1385 1’ ( .3 ) 3.6 ( 1.6 )1386 2’ ( .61 ) 7.0 ( 3.2 )1356 3’ ( .92 ) 9” ( 228.6 ) Drilled 4 10.0 ( 4.5 )1357 4’ ( 1.2 ) 12.0 ( 5.4 )2496 6’ ( 1.8 ) 19.0 ( 8.6 )4460 4’ ( 1.2 ) 9” ( 228.6 ) Bonded 5 12.0 ( 5.4 )2486 6’ ( 1.8 ) 19.0 ( 8.6 )2461 1’ (.3 ) 5.0 ( 2.3 )2462 2’ ( .61 ) 12” ( 304.8 ) Drilled 4 8.0 ( 3.6 )2464 4’ ( 1.2 ) 15.0 ( 6.8 )2466 6’ ( 1.8 ) 22.0 ( 10.0 )2474 4’ ( 1.2 ) 12” ( 304.8 ) Bonded 5 15.0 ( 6.8 )2478 6’ ( 1.8 ) 22.0 ( 10.0 )All guards are tested to ASTM F712 and are manufactured to ASTM F968 specificationsC-4SALISBURY Insulating Plastic Guards and Covers. www.wh<strong>salisbury</strong>.com


VERSA® AND LINK® GUARDSVersa and Link Guards make use of air as well as thedielectric strength of plastic to provide total insulatingvalue. Both guards are 7” in diameter and have a hookshaped inner lip to keep the guard in place.Versa and Link GuardCross SectionVersa Guards, with a voltage rating of 36.6 kV*, are designedso that two guards can be coupled together to cover most 13 kVsingle and double arm, pin and post constructions. A lighter 47”version (2389) of the standard 4.5’ Versa Guard is availablein a Type III PPO material.Link Guards, with a voltage rating of 72.5kV*,have inner and outer shells that run full lengthto include male and female couple ends. Twoguards connected provide four overlappingthicknesses of plastic plus air at a joint.16862475Tee Connectors are used on horizontal and vertical postsand suspension insulator strings when plastic line guardsare used on the conductor. Made from Type I, ABSplastic with eye fittings, the connector accommodatesthe male end of a guard. Available intwo ratings: 72.5 kV* and 48.3 kV*. Accepts34.5 kV pin insulators along with post and insulatorstrings.*guarded Ø to guarded Ø .Cat. No. Description Type ASTM Grade Weight ea.Voltage Classlbs. ( kgs)VERSA GUARDS- 4.5’ ( 1.37 m )1686 ABS Eye I 4 2 8.8 ( 4.0 )1687 ABS 4’ Stick I 4 1 10.8 ( 4.9 )1688 ABS 6’Stick I 4 1 11.8 ( (5.4 )2373 PPO Eye III 4 2 8.8 ( 4.0 )2377 PPO 4 ’Stick III 4 1 10.8 ( 4.9 )2378 PPO 6’ Stick III 4 1 11.8 ( 5.4 )2389 Lightweight 47” PPO 4’ Stick III 4 1 6.1 ( 2.8 )2689 Lightweight 47”PPO Eye III 4 2 8.1 ( 3.7 )LINK GUARDS- 4.5’ ( 1.37 m )1680 ABS Eye I 6 2 10.5 ( 4.8 )1681 ABS 4’ Stick I 6 1 12.5 ( 5.7 )1682 ABS 6’ Stick I 6 1 13.5 ( 6.1 )2475 PPO Eye III 6 2 10.5 ( 4.8 )2476 PPO 4’ Stick III 6 1 12.5 ( 5.7 )2477 PPO 6’ Stick III 6 1 13.5 ( 6.1TEE CONNECTORS2224 69 kV I 6 2 7.8 ( 3.5 )2884 46 kV I 5 2 6.0 ( 2.7 0All guards are tested to ASTM F712 and are manufactured to ASTM F968 specificationsBags are availableon page C-10.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.24012884C-5


LIGHTWEIGHT CONDUCTOR COVERS21315Lightweight Conductor Covers are ideal to coverlong spans when weight is a consideration. They canbe applied when wearing rubber gloves or with afiberglass stick. Available with an eye for applicationwith shotgun sticks. These covers have a voltagerating of 26.4 kV*. The inside diameter is 2". Thisproduct can connect with Salisbury 1.5" I.D. Class 3or 4 flexible cover-up equipment.21172The NEW 21826 Lightweight Conductor Cover is asix (6’, 1.8m) foot, cover rated Class 4 (36.6 kV*).It is applied using rubber gloves when followingappropriate company work rules. The inside diameter is3" making it useful on a wide range of conductor sizes.21173The unique “connector-stop” molded into one endprevents covers from overlapping during installation.This eliminates wasted time when trucks have to bemoved to re-connect sections that did not couplecorrectly. This cover is also compatible withSalisbury 1.5" I.D. class 3 or 4 flexible rubber line hose.21234 Adapter EyeAll of our lightweight covers are made from safetyorange Type I high density cross link polyethylene.*guarded Ø to guarded Ø .21826NEWConductor Covers connect easily with eitherplastic or rubber line hose21826 Unique Connector StopCat. No. Description ASTM Grade Weight ea.ft. ( m ) Voltage Class lbs. ( kgs )CONDUCTOR COVERS21172 5’ ( 1.5 ) Cover w/ Eye 3 2 4.0 ( 1.8 )21173 5’ ( 1.5 ) Cover w/o Eye 3 -- 3.0 ( 1.4 )21315 5’ ( 1.5 ) Cover w/ 4’ ( 1.2) Fiberglass Stick 3 1 5.0 ( 2.25 )21234 Adapter Eye 3 -- 1.5 ( 0.7 )35kV CONDUCTOR COVER21826 6’ ( 1.8 ) Cover 4 -- 3.0 ( 1.4 )All guards are tested to ASTM F712 and are manufactured to ASTM F968 specificationsC-6SALISBURY Insulating Plastic Guards and Covers. www.wh<strong>salisbury</strong>.com


CROSSARM GUARDSCrossarm Guards are available in two differentstyles: the 1370 pin type and the 1371 post type.They are used to prevent tie wires from contactingcrossarms during hot line operations. Twodifferent tie downs Rare provided: a neoprene anda polypropylene rope. Both are secured in theslots provided in the eye fitting. The post typemodel has an automatic gap closer which coversthe insulator slot opening over the end of thearm.1370The Slide-On Crossarm Guard 736PH isapplied by sliding the cover on to the arm fromthe end using the Grade 2 shotgun eye until theunit locks onto the insulator pins. The coveroverlaps on top and has notches to ease applicationand removal.Both of these guards are made from orangeType I ABS cold weather high impact plastic.These guards have a voltage rating of 36.6 kV*.*guarded Ø to guarded Ø .1371Cat. No. Description Dimensions ASTM Weight ea.in. ( mm ) Voltage Class lbs. ( kgs )1370 Crossarm or Pin Type Guard 9 x 9 x 25.5 ( 229 x 229 x 648 ) 4 5.7 ( 2.6 )1371 Crossarm or Post Type Guard Fits Crossarm:5 x 6 ( 127 x 152 ) 4 6.0 ( 2.7 )736PH Slide-On Crossarm Guard 7” I.D. x 36” ( 178 I.D. x 914 ) 4 4.5 ( 2 )All guards are tested to ASTM F712 and are manufactured to ASTM F968 specifications736PHS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401C-7


SUBSTATION COVER-UPBus GuardsSubstation Cover-up and barrier equipment is usedfor routine maintenance where outages are difficultto get to. These covers may be applied with rubbergloves or hot sticks. These covers are made fromType I orange ABS plastic. This equipment is notintended for permanent or semi-permanent barrier orinsulating applications. Use these covers to protectagainst accidental contact only. These covers arenot to be left installed for extended periods of timeespecially when in contact with both a grounded andenergized object.1374Bus GuardBus Guards are easily interlocked with each other.To interlock units determine the length of bus to becovered. Place one unit on the bus then the other,pulling it over the first cover until the dimplesinterlock at the required length. This guard has avoltage rating of 36.6 kV*.Bus “T” Guards interlock two or three bus guardsat bus tap “T” connections and 90 degree angles. Tointerlock units, first position the bus guard then slidethe “T” guard over the top interlocking the dimples.This guard has a voltage rating of 36.6 kV*.1375Bus “T” GuardBus End Guards cover the ends of a substation bussupported by station post insulators. The slot andinsulator grip hole can be easily enlarged in the fieldwith a sharp knife. This cover also has a guide beadfor a trim fit. This guard has a voltage rating of26.4 kV*.Eye kit is available on page C-10.*guarded Ø to guarded Ø .9992Bus End GuardCat. No. Dimension Description ASTM Weight ea.in. ( mm ) Voltage Class lbs. ( kgs )Bus Guard1374 5.25”x 9.5”x4.5’ ( 133 x241x1.4m ) Impact Resistant 4 6.0 ( 2.7 )Bus “T” Guard1375 5”x15”x25” ( 127x381 x635 ) ABS Plastic 4 4.0 ( 1.8 )Bus End Guard9992 8.5”x12”x24” ( 216x305x610 ) UV Resistant 3 5.0 ( 2.3 )Linear PolyethyleneAll guards are tested to ASTM F712 and are manufactured to ASTM F968 specificationsC-8SALISBURY Insulating Plastic Guards and Covers. www.wh<strong>salisbury</strong>.com


SUBSTATION COVER-UPSwitch Jaw Guard & BarrierSwitch Jaw Guards insulate the energizedupper switch jaw and insulator when workis being done on the switch blade, lowerinsulator or other de-energized equipmentahead of the open switch. These guardseasily slide over the upper insulator onopen substation switches and lock overthe bus. Jaw Guards are made from TypeI UV resistant plastic. This guard has avoltage rating of 26.4 kV*.The 24219 Switch Jaw Cover provides aninsulated barrier to the energized upper switchjaw and insulator, when work is being done onthe switch blade, lower insulator, or other deenergizedequipment ahead of the openswitch. This guard slides easily over theupper insulator on open substation neutraldisconnect cabinet switches and locksover the bus. The 24219 Cover is madefrom Type I cold weather high impact plastic.This guard has a voltage rating of 14.6 kV*.The T1, Terminal Sleeve Disconnect Switch isused on open style disconnects.Switch Barriers slide between the last two skirtson the post or pin cap insulators of the substationdisconnect switch. This locks the barrier inplace. When switches are mounted back to backand work is needed on one, the barrier can beplaced on the energized switch to form a visible,electrical and mechanical barrier. Work can thenbe done on the opposite switch or other deenergizedequipment. This guard has a voltagerating of 36.6 kV*.241824219NEWNEW24455Barrier and SwitchJaw Guard installed on aSubstation Switch.T1NEW*guarded Ø to guarded Ø .1376Cat. No. Dimensions Description ASTM Weight ea.in. (mm) Voltage Class lbs. ( kgs )NOTE: If your substation needsare not fulfilled by the productson this page, please contact yourlocal Salisbury representativefor custom applications.JAW GUARD2418 8” D. x 18” ( 203 D. x 457 ) Use w/ switch 8”(203) Dia. 3 4 ( 1.8 )2424 8” D. x 24” ( 203 D. x 610 ) Insulated 3 5 ( 2.3 )24455 8” D. x 16” ( 203 D. x 406 ) 3 2.25 ( 1.14 )2413 13” D. x 24” ( 330 D. x 610 ) Use w/ switch 13”(330) Dia. 3 7 ( 3.2 )Pin Cap InsulatorsJAW COVER & TERMINAL SLEEVE24219 Jaw Cover 2 4 ( 1.8 )T1 10” x 2” I.D. ( 254 x 51 I.D. ) Terminal Sleeve .33 ( .15 )BARRIER1376 .125”x43”x52” ( 3.2x1092x1320) Orange Type I High Impact 4 12 ( 5.5 )5” ( 127 ) slot to center ABS PlasticS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401C-9


GUARD AND COVER ACCESSORIESBags for Line and Pole Guards come inthree different sizes and can hold eithertwo nested pole or line guards. The 1871bag is designed for pole guards only. Bagsare made from soil resistant vinyl coatednylon and equipped with a drawstring andmail bag lock.1933The Applicator Eye Kit is used to apply anew or extra shotgun eye where needed.If a Bus or “T” guard needs to be shortenedor inverted, this kit allows fieldmodifications to be made. Clear PVC pipecement may be used to secure the eye.Directions are included.The Insulating Barrier Sheet can beused to create barriers in the field. Thissheet is made from Type I ABS plastic andcan be worked with ordinary hand tools,saws, tin snips and drills. It can also behot formed using a heat gun. For example,this sheet can be bent at right angles overa table top to produce flanges for joiningwith other parts. Solvent welding PVCpipe adhesive can be used to join to otherparts. The rated puncture is 400v/mil 60 Hz.28428’ (2439mm)13784’ (1219mm)Cat. No. DescriptionASTM Weight ea.ft. ( m ) in. ( mm )Voltage Class lbs. ( kgs )BAGS1933 2 - 4.5’ ( 1.4 )line guards or 2 - 9” x 4’ ( 229 x 1.22 )Pole Guards 3.5 ( 1.6 )1841 2 - 6’ ( 1.8 ) line guards or 2 - 9” x 6’ ( 229 x 1.8 ) Pole Guards 4.5 ( 2.0 )1871 2 - 12” x 6’ ( 305 x 1.8 ) Pole Guards 5.2 ( 2.4 )EYE KIT1378 2 eyes per kit .25 ( .11 )BARRIER SHEET2842 4’ x 8’ x .125” ( 1.2m x 2.4m x 3.2 ) 36 ( 16.4 )C-10SALISBURY Insulating Plastic Guards and Covers. www.wh<strong>salisbury</strong>.com


GUARD AND COVER ACCESSORIESThe Universal Hot Cover is used to provideadditional cover-up and clearances. This cover ismade from orange Type I polyethylene plastic. TheGrade 2 hot stick eye allows this cover to be placedand removed with a shotgun type clamp stick or withrubber gloves. To secure in place use the elastic tiedowncord. This cover can be used on overhead orunderground energized cable terminators, potheadsor while inverted, on lightning arrestors. The maximumexposure voltage is 26.4 kV*.816The Pole Bracket and Insulator Base Coverguards against accidental contact with pole, bracketand insulator base during routine maintenance. It ismade from an orange UV resistant Type I polyethyleneplastic. The Grade 2 hot stick eye allows thiscover to be applied and removed with a hot stick orwith rubber gloves. It covers metal or fiberglassbrackets 8-12” long and pole mounting plates. Thiscover also interlocks with a pole insulator. Themaximum exposure voltage is 26.4 kV*.The Underground Distribution Elbow Covercovers primary elbows and spade terminals duringroutine maintenance. It covers up to the face plateand cable connection. This cover is made fromorange Type I polyethylene plastic. The Grade 2 hotstick eye allows this cover to be applied and removedwith a hot stick. This cover self locks for a secure fitin confined areas. The bead can be trimmed in thefield to meet clearance requirements. The maximumexposure voltage is 26.4 kV*.Elbow43334314Pole Bracket andInsulator Base Cover*guarded Ø to guarded Ø .Elbow Cover ApplicationCat. No. Description ASTM Weight ea.Voltage Class lbs. ( kgs )816 Hot Cover 8” x 16” ( 203 x 406 ) 3 2.5 ( 1.1 )4333 Pole Bracket & Insulator Base Cover 20” x 25” ( 508 x 635 ) 3 2.5 ( 1.1 )4314 Underground Distribution Elbow Cover 15” x 14.25” ( 381 x 362 ) 3 2.0 ( .9 )All guards are tested to ASTM F712 and are manufactured to ASTM F968 specificationsS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401C-11


OUTAGE PROTECTIONOutage Protection - IntroductionSilicone Bushing CoversStinger CoversInstant InsulationS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401D-1


OUTAGE PROTECTIONProtect against costly outages.A million outages are created by animalwildlife every year in this country at anaverage cost of $2,700 for minor incidentsto ten times that for major repairs.The average outage time is an hour. Yetmost of these outages are preventable;independent studies realized a 78% dropin wildlife outages after installingguards.*Salisbury, the leader in quality protectivecover-up equipment, provides the systemthat works to protect valuable equipmentand substantially reduce or eliminateoutages.* According to independent studies conducted by New YorkState College of Agriculture and Life Sciences, Cornell University,and the Department of Forestry, Fisheries, and Wildlife, and theUniversity of Nebraska in October of 1987.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401D-3


NEWSILICONE BUSHING COVERSStandard Salisbury Bushing Covers andSalisbury Tri-Port Bushing Covers aremade from Type II Ozone and UV resistantsilicone rubber, maximizing theoutdoor durability and tracking resistance.21116 - Standard- 3.87” (98.3mm) -Bushing GuardPort3.37”(85.6mm)Bushing Covers protect against wildlifecontacts between energized equipment andground by insulating exposed energizedbushing parts.Standard and Tri-Port Bushing Coversinterlock with the top weathershed of thebushing and are securely fastened byinserting lock buttons (provided).PortPort5” (127mm)Dia.Tri-Port Bushing Guard7”(178mm)Bushing Covers can be installed withoutdisconnecting equipment using rubberinsulating gloves. Covering a small area ofthe lead wire, the opening can be trimmedto accommodate larger wires or 5/8” and3/4” Salisbury Stinger Covers.21317 - Tri-Port1”(25.4mm)12” (305mm)BC5125”(127mm)Cat. No. Description Dimensions Quantity Flashover Test Weight ea.in. ( mm ) Voltage lbs. ( kgs )BUSHING COVERS21116 Cover Only 24 pcs. 16 kV 16 ( 7.3 )21183 Cover Kit w/Stinger Cover* .375 x 18 ( 9.5 x 457 ) 24pcs. n/a 20 ( 9 )BC512 Cone Bushing Cover 12H x 5 W ( 305 H x 127 W ) 1 n/a 1.5 ( .7 )TRI-PORT BUSHING COVERS21317 Cover Only 24 pcs. 16 kV 28 ( 12.7 )24140 Cover Kit w/ Stinger Cover* 3/8 x 18 ( 9.5 x 457 ) 24 pcs. n/a 35 ( 16 )* See page D-5 for more Stinger CoversD-4SALISBURY Outage Protection. www.wh<strong>salisbury</strong>.com


STINGER COVERSStinger Covers protect againstwildlife contacts between energizedequipment and ground by insulatingthe lead wire.The stinger cover can be installedwithout disconnecting the lead wirefrom the bushing. Available in threediameters, it is easily cut in the fieldto the needed length.Stinger covers are track resistantand made from Type II Ozone andUV resistant SALCOR® elastomerin a grey color. The covers areproven to provide years of reliableservice either independently or whenused with bushing covers.Stinger Cover Cross-Section38-50SCCat. No. I.D. Dimensions Quantity Flashover Test Weightin. ( mm ) ft. ( m ) Voltage kV lbs. ( kgs )EPDM38-2SC 3/8 ( 9.5 ) 2 ( .61 ) 25 pcs. 13 9 ( 4.1 )38-50SC 3/8 ( 9.5 ) 50 ( 15.3 ) 1 coil 13 9.5 ( 4.3 )38-12SC 3/8 ( 9.5 ) 12 ( 3.7 ) 4 pcs. 13 9.5 ( 4.3 )38-18SC 3/8 ( 9.5 ) 18 ( 5.49 ) 50 pcs. 13 11 ( 5 )38-100SC 3/8 ( 9.5 ) 100 ( 30.5 ) 1 coil 13 19 ( 8.6 )58-12SC 5/8 ( 15.9 ) 12 ( 3.7 ) coil 4 pcs. 18 10.5 ( 4.8 )58-50SC 5/8 ( 15.9 ) 50 ( 15.3 ) coil 1 pc. 18 21 ( 9.5 )58-100SC 5/8 ( 15.9 ) 100 ( 30.5 ) coil 1 pc. 18 46( 20.9 )34-12SC 3/4 ( 25.4 ) 12 ( 3.7 ) coil 4 pcs. 20.5 11 ( 5 )34-25SC 3/4 ( 25.4 ) 25 ( 7.6 ) coil 2 pc. 20.5 13 ( 6 )For sizes and lengths other than those listed above, contact your local Salisbury representative.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401D-5


INSTANT INSULATIONInstant Insulation may be installed aspermanent cover to protect against outagescaused by weather, trees and animal. InstantInsulation resists ozone and ultravioletdeterioration while remaining flexible even atsub-zero conditions.1127Instant Insulation is made of orange or greySALCOR® elastomer. Instant Insulation issold in three diameters, each 12 feet inlength. Each include six nylon UV resistantbar-lock tie wraps to secure it to the conductor.Instant Insulation can be installed using the2494 Applicator. To install, insert one endof the Instant Insulation into the applicatorprongs, then roll and coil the insulation asshown. Secure the coil end with tape, tystraps,or rubber bands. To install, releasethe secured end and the Instant Insulationwill unroll and enclose the conductor.2494Cat No. Dimensions Color Weight ea.in. mm lbs. kgsINSTANT INSULATION 12’ / 3.6m long1127 .75 I.D. 19 I.D. Grey 7 3.21128 .75 I.D. 19 I.D. Orange 7 3.21129 1.00 I.D. 25 I.D. Grey 8 3.61130 1.00 I.D. 25 I.D. Orange 8 3.61131 1.25 I.D. 32 I.D. Grey 10 4.51132 1.25 I.D. 32 I.D. Orange 10 4.52494 Universal Hot Stick Applicator 1 .5D-6SALISBURY Outage Protection. www.wh<strong>salisbury</strong>.com


GLOVES & SLEEVESASTM ChartRubber Insulating Gloves - IntroductionVisual Inspection of Rubber Insulating Gloves and SleevesMechanical Inspection of Rubber Insulating Gloves and SleevesLinemen’s Gloves - Low Voltage - ASTM Class 0 and 00Linemen’s Gloves - High Voltage - ASTM Class 1 - 4Linemen’s Mittens - High Voltage - ASTM Class 1 - 4Glove LinersLeather Protectors - IntroductionPremium Leather ProtectorsLeather ProtectorsSALPOL and Work GlovesLinemen’s Sleeves - DippedLinemen’s Sleeves - MoldedLinemen’s Sleeves - AccessoriesS ALISBURYGlove and Sleeve StorageHand and Glove Cleaners and PowdersSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401E-1


ASTM ChartRubber and SALCOR® Protective EquipmentRubber insulating gloves are available in six ASTM defined voltageclasses. Rubber insulating sleeves are available in Class 0 through4. The chart below identifies the class, proof test voltage and maximumallowable exposure voltage.For an 8 x 10 reprint of this chart, contact your local Salisbury representative.ASTM Labeling Chartfor Salisbury Linemen’s Natural Rubber and SALCOR® Rubber Protective EquipmentProof Test Max. Use RubberClass Voltage Voltage Molded Glove Label Rubber DippedColor AC / DC AC / DC* Products Sleeve LabelLabel00Beige2500 / 10,000 500 / 750*0Red5,000 / 20,000 1,000 / 1,500*1White10,000 / 40,000 7,500 / 11,250*2Yellow20,000 / 50,000 17,000 / 25,500*3Green30,000 / 60,000 26,500 / 39,750*4Orange40,000 / 70,000 36,000 / 54,000**Maximum use DC voltage is not part of any ASTM specification. Maximum use DC voltages are valid in reference to IEC 903 only.Gloves and Sleeves must have a color coded label.“Suitable for live working.”IEC60903:2002 & IEC60417 fig. 5216E-2SALISBURY Gloves and Sleeves. www.wh<strong>salisbury</strong>.com


SALISBURY LINEMEN’S GLOVESManufactured foroutstanding protection,comfort and long-lifeRubber insulating gloves are amongthe most important articles of personalprotection for electrical workers.Incorporating high dielectric andphysical strength, flexibility and durability,Salisbury rubber insulating gloveshave earned the reputation for superiorperformance-meeting and exceedingthe requirements of current ASTMD120 specifications.Salisbury rubber insulating gloves aremanufactured by dipping porcelainforms into a tank of liquefied rubber.The thin layer of rubber whichresults is allowed to dry and theprocess is repeated until the requiredthickness is reached. Depending on the voltage classof the glove, this dipping-drying-dipping cycle may need to be repeatedover 30 times. After the desired thickness is achieved, the gloves areallowed to dry. Once dry, they are cut to length, the reinforcing bead isrolled, and the ASTM label and manufacturing information is appliedalong with any additional permanent marking that may be requested.The gloves are cured in an autoclave under steam pressure and heat. Aftercuring, the gloves are visually inspected. Gloves with visual imperfectionsare rejected. The gloves are then given a halogenation treatment (chlorination)to increase the comfort and wearability. The remaining gloves areelectrically tested following ASTM D120/IEC 903 specifications. Followingthe electrical test, the gloves are given a final visual inspection. Thegloves are then ready to be boxed and shipped.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401E-3


INSPECTIONRubber InsulatingGloves and SleevesType I natural and Type II SALCOR® syntheticrubber both provide electrical workers with thehighest level of electrical insulating protection.However, in order to maintain this level of protectionand ensure long life, it is essential thatgloves and sleeves are properly cared for andstored. Before each use, gloves and sleevesshould be inspected for holes, rips or tears,ozone cutting, UV checking and signs of chemicaldeterioration. Refer to ASTM F1236, standard guidefor visual inspection of electrical protective rubberproducts for additional information.Inflating the glove stretches the rubber makingcuts, tears or ozone damage easier to detect.As stated in ASTM specifications for In ServiceCare and Use of Rubber Gloves andSleeves, gloves and sleeves should be expandedno more than 1.5 times their normal size forType I, and 1.25 times normal for Type IISALCOR. Holes are located by listening for escapingair. If a portable inflator is unavailable,the cuff of the glove can be rolled tight to trapair inside, then apply pressure to areas of theglove to inspect for escaping air. The procedureshould then be repeated with the gloveturned inside out. Since sleeves cannot be inflated,they are inspected along the edge as theyare rolled. Rolling will stretch the sleeve alongthe edge, making cuts, tears and ozone cuttingmore visible. After the outside of the sleeve isinspected, the procedure should also be repeatedwith the sleeve turned inside out.Common Problems to Look ForCracking & CuttingShown above is the damagecaused by prolonged folding orcompressing.SnagsDamage shown here is due towood and metal splinters andother sharp objects.Chemical AttackThis photo shows swellingcaused by oils and otherpetroleum compounds.UV CheckingStoring in areas exposed toprolonged sunlight causesUV checking.Gloves and sleeves should also be examined todetermine if they show any damage as a resultof chemical contamination. Both natural rubberand SALCOR materials are susceptible tosuch damage, particularly from petroleum products.The first sign of exposure to petroleumproducts is swelling in the area of the contamination.Should any rubber equipment be exposedto chemical contaminants or be suspect of anyother physical damage, it should be turned infor inspection, cleaning, and electrical testing.Avoid Folding GlovesThe strain on rubber at a foldedpoint is equal to stretching theglove to twice its length.Avoid Storing Inside OutGloves should never be storedinside out. Storing glovesreversed strains the rubberseverely and causes ozone cutting.E-4SALISBURY Gloves and Sleeves. www.wh<strong>salisbury</strong>.com


MAKING A PROPER INSPECTIONOSHA 1910.137 states “Insulatingequipment shall be inspected before eachday’s use and immediately following anyincident that can reasonably be suspectedof having caused damage. Insulatinggloves shall be given an air test, alongwith the inspection.” Salisbury’s G99 isthe perfect answer for inflating yourgloves for inspection.G99The G99 is a simple, easy to use, portableglove inflator. The G99 provides a qualitymeans of inspecting gloves in the field.The glove is secured to the inflator usinga nylon strap and fastened with hook andpile, or a rubber “O” ring. Inflation isaccomplished by pumping the bellows ofthe inflator against any smooth flatsurface.G1In the test lab or service center, the G1and G2 glove inflators are preferred.Being pneumatically operated, largequantities of gloves can be inspected inminimal time. The G1 is pedestalmounted and requires connection to asource of compressed air. This providesmaximum efficiency for testing largequantities of gloves. The G2 benchmounted inflator is ideal for smallerquantities of gloves. This inflator isoperated by a built in hand pump.Cat. No. Description Weight ea.lbs. ( mm )G99 Glove Inflator Kit 2 ( .91 )G99B Replacement Bag -G99R Replacement “O” Ring -G99S Replacement Strap -G99V Replacement Check Valve -G1 Pedestal w/ Foot Control 45 ( 20.4 )G2 Bench Type w/ Hand Pump 40 ( 18.1 )G2S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401E-5


SALISBURY LINEMEN’S GLOVESLow Voltage - ASTM Class 0, 00Selecting the right size, length and styleSalisbury linemen’s gloves are available in a full rangeof sizes, from 8 through 12, including half sizes.Proper fit is important to minimize chafing and fatigue.To determine glove size, measure the circumferencearound the palm. Allow for additional room if fabricglove liners are to be worn, especially with thermalliners.Class 0 and 00 gloves are available in 11 and 14 inchlengths. Class 00 Electrical Insulating RubberGloves are made from red Type I natural rubber, blueType II SALCOR®, or in contrasting blue/orangeType II SALCOR. The contrast between the thin outerorange color against the inner blue color makesinspecting for cuts and tears easier when the glove isinflated or stretched.Class 0 Electrical Insulating Rubber Gloves areavailable in red, black, and yellow in Type I NaturalRubber. These gloves are also available in blue, black/yellow, and blue/orange, Type II SALCOR rubber.E011Y Gloves being manufactured.E0011BL9HBoth are extremely flexible to make working withsmall parts easy. The gloves meet or exceed ASTMD120 and IEC 903 Standards.Cat. No. Breakdown for Class 00 GlovesClass Length Color SizeE014R10HE 00 11 R, BL, or BLO 8, 8H9, 9HE 00 14 R, BL, or BLO 10, 10HR=red Type I Natural Rubber11, 11HBL=blue BLO=blue in, orange out Type II Salcor 12Example: E0011BL8Cat. No. Breakdown for Class 0 GlovesClass Length Color SizeNEWE011BLO10E 0 11 Y, B, R, BL, BLO or BY 8, 8H9,9HE 0 14 Y, B, R, BL, BLO or BY 10, 10HR=red B=black Y=yellow:Type I Natural Rubber 11, 11HBY=black in, yellow out:Type I Natural Rubber 12BL=blue:Type II SalcorBLO=blue in, orange out:Type II SalcorExample: E014R9Measure the circumferencearound the palm.E-6SALISBURY Gloves and Sleeves. www.wh<strong>salisbury</strong>.com


SALISBURY LINEMEN’S GLOVESHigh Voltage - ASTM Class 1, 2, 3, 4Class 1 through 4 gloves are available inthe industry standard color black, or incontrasting two-color combinations.The contrast between the thin outercolor against the inner color makesinspecting for cuts and tears easierwhen the glove is inflated or stretched.Class 1 through 4 gloves are available in14, 16 and 18 inch lengths. A straightcuff is standard on 14” (356 mm), 16”(406 mm) & 18” (457 mm) gloves.The straight cuff is the default.A contour cuff is angled to preventbunching or binding at the elbow whenthe arm is bent. The straight cuff is thedefault style.The bell cuff and flare cuff, accommodateheavier winter clothing andallow for greater air flow in warmerweather. These are available for Class 1through 4 gloves. Bell cuff gloves arenot available in sizes 8 or 8H, flare cuffgloves are not available in size 8.Straight CuffE316YB10Contour CuffE218CYB10Bell CuffE216BCYB9HFlare CuffE214FCRB9Cat. No. Breakdown for Class 1,2,3,4 GlovesClass Glove Length Cuff Style Color Sizein.E 1* 14, 16 or 18 FC, BC, C B, YB or RB 8, 8HE 2* 14, 16 or 18 FC, BC, C B, YB or RB 9,9HE 3* 14, 16 or 18 FC, BC, C B, YB or RB 10, 10HE 4* / ** 14, 16 or 18 FC, BC, C B, YB or RB 11, 11HFC=flare cuff BC=bell cuff C=contour cuff 12*Straight cuff is the standard.B=black YB=Y inside, B out RB=R inside, B out:Type I Natural RubberExample: E116FCYB10** Class 4 gloves come in full and half sizes 9-12 only.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401E-7


SALISBURY LINEMEN’S MITTENSHigh Voltage - ASTM Class 1, 2, 3, 4Salisbury Lineman’s Mittens are made from the samedurable, lightweight rubber as the five finger gloves yetkeep the user warmer during harsh temperatures. The threefinger mitten allows for precise hand movement as well.Class 1 through 4 mittens are available in the industrystandard black or in contrasting two-color combinations.The contrast between the thin outer color against the innercolor makes inspecting for cuts and tears easier when theglove is inflated or stretched.Class 1 through Class 4 mittens are available in 14, 16 and18 inch lengths. A bell cuff design is standard on allmittens. BC=Bell Cuff.Mittens are available in sizes 9, 10, and 11 only.EM216BCRB11Cat. No. Breakdown for Class 1,2,3,4 GlovesClass Glove Length Cuff Style Color Sizein.EM 1 14, 16 or 18 BC B, YB or RB 9EM 2 14, 16 or 18 BC B, YB or RB 10EM 3 14, 16 or 18 BC B, YB or RB 11EM 4 14, 16 or 18 BC B, YB or RBBell Cuff colors B=black YB=Yellow inside, Black out RB=Red inside, Black outE-8SALISBURY Gloves and Sleeves. www.wh<strong>salisbury</strong>.com


SALISBURY LINEMEN’S GLOVE LINERSLiner Gloves reduce the discomfort ofwearing Rubber Insulating Gloves in allseasons. For year round use, linersprovide warmth in cold weather, whilethey absorb perspiration in the warmmonths. Many styles and fabrics areavailable with either a open or knit wrist.The knit wrist style grips the wristrather than allowing the cuff to rolldown and bunch at the palm. All LinerGloves are for year round use withRubber Insulating Gloves and Mittens.All liners are made from stretch fabricthat can fit any hand size.L10JKL10JThe L Series has a tough outer cottonfabric while the inner lining is soft andcomfortable. The LMKC Series is light,airy and allows ease of movement. TheLMKW Series is made from a RagWool fabric that moves easily yet givesa substantial layer of lining.L12JL12MKCThe 89 Series is Salisbury’s classicsummer and winter glove liner. Linersabsorb perspiration from hands. Thesummer liner is white in color and 100%cotton. The winter blend is a rust colorand 85% orlon and 15% nylon.L10MKW89/1402 89/4702Cat. No. Description Wrist Length Weight ea.Style in. ( mm ) lbs. ( kgs )L10JK Jersey Style, Light Weight, Seams Out Knit 10 ( 254 ) .14 (.06)L10J Jersey Style, Light Weight, Seams Out Open 10 ( 254 ) .12 (.06)L12J Jersey Style, Light Weight, Seams Out Open 12 ( 305 ) .14 (.07)L10MKC Machine Knit, 100% Cotton Knit 10 ( 254 ) .12 (.05)L12MKC Machine Knit, 100% Cotton Knit 12 ( 305 ) .12 (.05)L10MKW Machine Knit, Cotton/Wool Blend Knit 10 ( 254 ) .14 (.06)L12MKW Machine Knit, Cotton/Wool Blend Knit 12 ( 305 ) .14 (.07)89/1402 White Machine Knit, 100% Cotton Knit 10 ( 254 ) .12 (.06)89/4702 Rust Machine Knit, Acrylic Blend Knit 10 ( 254 ) .12 (.06)One size fits all.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401E-9


LEATHER PROTECTORSLeather Protector Gloves should always beworn over Rubber Insulating Gloves to providethe needed mechanical protection against cuts,abrasions and punctures. All Salisbury protectorsare steamed pressed on curved hand forms toinsure proper fit over Rubber Gloves. Manufacturedfrom top grade leather, all are sewn withheavy duty nylon thread in the “gunn cut” inseamconstruction pattern. Protectors are dual sized.Single sized marked protectors are available byspecial order. Each protector for Class 1-4 glovesare equipped with a nonmetallic buckle on the pullstrap and an extra wide leather reinforcement overthe thumb seam. Protectors for Class 0 and 00gloves are available with non-metallic buckle andpull strap or elastic wrist.It is the responsibility of the purchaser to specifythe overall length of the protector gloves. TheClearance Table shows the minimum distancewhich shall be allowed between the top of theprotector glove cuff and the top end of the beadof the rubber glove per ASTM F496 Specifications.Your company work rules should befollowed in case of a discrepancy.WARNING: Do not use leather protectorsalone for protection against electric shock.Serious injury or death will result. Always useproper rubber insulating gloves.CLEARANCE TABLEGloveMin. Distance BetweenClass Tops of Protectors and Rubber Glovesin.mm0, 00 1/2 131 1 252 2 513 3 764 4 102Proper care of leather protectors is essential touser safety. Inspect the leather protectors wheninspecting rubber gloves. Metal particles, imbeddedwire, abrasive materials or any substance thatcould physically damage the rubber gloves mustbe removed from the protector before use.E-10SALISBURY Gloves and Sleeves. www.wh<strong>salisbury</strong>.com


PREMIUM LEATHER PROTECTORS156 Premium SeriesThese protectors have a palm made from specially tannedGrade A Red Boulevard buffed leather and an orange coloredSALCOR® “Super Cuff” in the 4” (102 mm) and 6” (152mm) cuff lengths. The “Super Cuff” has better characteristicsthan leather cuffs; it does not absorb water, has greatertrack resistance, and greater surface creepage.Cat. No. Cuff Length OAL Length Weight ea.in. ( mm ) in. ( mm ) lbs. ( kgs )156-4 4 ( 102 ) Straight Cuff 12 ( 305 ) 1 ( .5 )156-6 6 ( 152 ) Straight Cuff 14 ( 356 ) 1.2 ( .5 )Available in dual sizes: 8/8.5, 9/9.5, 10/10.5, 11/11.5, 12156-6103 Mitten ProtectorThree finger mitten protectors provide mechanical protectionfor lineman’s rubber insulating mittens. They are constructedof the same high quality Grade A Red Boulevard buffedleather as the 156 series protectors. The SALCOR® “SuperCuff” is standard for 4” (102 mm) or 6” (152 mm) cuffs.With a non-metallic nylon pull strap fastened at the wrist,these protectors are designed for comfort and long wear.Cat. No. Cuff Length OAL Length Weight ea.in. ( mm ) in. ( mm ) lbs. ( kgs )103 SERIES103-4 4 ( 102 ) Cuff 12 ( 305 ) 1.2 ( .5 )103-6 6 ( 152 ) Cuff 14 ( 356 ) 1.3 ( .6 )Available in sizes: 8/8.5, 9, 9.5/10, 10.5/11, 11.5/12103-4S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401E-11


LEATHER PROTECTORSLP SeriesManufactured from grain cowhide or goatskin, these protectorsoffer excellent comfort and protection. The LP Series protectorsfeature adjustable straps with non-metallic buckles and arestitched with polyester thread for strong seams. Cuffs are toughleather on palm side and orange vinyl on the back of the hand.Comes in single sizes, including half sizes, 8 through 12.ILP Series “Econo-Keeper”Manufactured from grain cowhide, pigskin, or goatskin, theseprotectors provide excellent protection for rubber insulatinggloves at a very economical price. Cowhide and pigskin cuffsare tough leather on palm side and orange vinyl on the back,while the goatskin cuffs are green leather on palm side andorange vinyl on back. Full complement of styles from low-voltthrough 16” contour cuff. Comes in dual sizes 8/8.5 through11/11.5 and 12.LPG3SLPG5SILPM SeriesManufactured from grain cowhide, these protectors offerexcellent comfort and protection. The ILPM Series mittenprotectors feature adjustable straps with non-metallic bucklesand are stitched with polyester thread for strong seams. Cuffsare tough leather on palm side and orange vinyl on the back ofthe hand. Comes in sizes 9, 10 and 11.Cat. No. OAL Length Weight ea.in. ( mm ) lbs. ( kgs )LP SERIESLP3S 12 ( 305 ) 1 ( .5 )LP4S 13 ( 330 ) 1 ( .5 )LP5S 14 ( 356 ) 1.2 ( .5 )LP6S 15 ( 381 ) 1.2 ( .5 )LP7C 16 ( 406 ) 1.5 ( .7 )LP10 10 ( 254 ) .7 ( .32 )LP10A w/ pull strap 10 ( 254 ) .7 ( .32 )To specify goatskin, use LPG.Available in single sizes: 8, 8.5, 9, 9.5, 10, 10.5, 11, 11.5, 12ILP SERIESILP3S* 12 ( 305 ) 1 ( .5 )ILP4S* 13 ( 330 ) 1 ( .5 )ILP5S* 14 ( 356 ) 1.2 ( .5 )ILP6S* 15 ( 381 ) 1.2 ( .5 )ILP7C* 16 ( 406 ) 1.5 ( .7 )ILP10* 10 ( 254 ) .7 ( .32 )ILP10A* w/ pull strap 10 ( 254 ) .7 ( .32 )*To specify pigskin, use ILPP or to specify goatskin, use ILPG.Available in dual sizes: 8/8.5, 9/9.5, 10/10.5, 11/11.5, 12ILPM SERIESILPM3S 12 ( 305 ) 1 ( .5 )ILPM4S 13 ( 330 ) 1 ( .5 )ILPM5S 14 ( 356 ) 1.2 ( .5 )Available in sizes: 9, 10, 11ILPP10ILPG7CLP7CILPG10AILPG10ILP10ILPM5SE-12SALISBURY Gloves and Sleeves. www.wh<strong>salisbury</strong>.com


SALPOL & WORK GLOVESSalisbury’s SALPOL Gloves protect hands during coldweather jobs. The black split cowhide leather has a 3MThinsulate* lining to keep hands warm in cold applications.For extra warmth a long knit wrist is sewn into the safetycuff to keep snow and ice from falling inside the glove. Theglove is designed in a wing thumb, gunn cut pattern. Theglove also has a full leather index finger, knuckle strap, leatherfingertips, and pull patch.*Thinsulate is a registered Trademark of the 3M Company.Salisbury WorkGloves are constructed of soft, flexible, yettough premium grade unlined leather. Designed for comfort andlong wear, with gunn cut design and split leather finger tipreinforcements. A split leather pull strap is included for additionalfit. Work Gloves are offered with a 2” (51mm) leather safetycuff or with a 4.5” (114mm) leather gauntlet cuff.Drivers Work Gloves set the standard for quality at an affordableprice. Combining comfort, durability and economy,Salisbury leather Drivers Work Gloves meet the tough challengesof today’s demanding workplace. Available in lined or unlinedstyles. The bindings are color coded to indicate size: red-small,green-medium, brown-large, purple-extra large.Linemen Work Gloves are designed specifically for use bylinemen and offers many of the quality features found in ourleather protectors. Made from high quality grain cowhide orgoatskin, this glove is soft and flexible, while still being highlyabrasion and cut resistant for long wear.SALPOL GLOVES & WORKGLOVESCat. No. Description Length Weight ea.in. ( mm ) lbs. ( kgs )SALPOL GLOVESSP-S Small Size Polar Glove n / a .5 ( .23 )SP-L Large Size Polar Glove n / a .5 ( .23 )WORKGLOVES312W* Safety Cuff Style 10 ( 254 ) .8 ( .4 )316W* Gauntlet Cuff Style 12.5 ( 318 ) 1 ( .5 )*Add “-S” for small, “-M” for medium, “-L” for large, “-XL” for extra-large.DRIVERS & LINEMEN WORK GLOVESCat. No. Description Weight ea.lbs. ( kgs )I95/217 WHS* Unlined .3 ( .14 )I95/317 WHS* Lined .3 ( .14 )*Add “-S” for small, “-M” for medium, “-L” for large, “-XL” for extra-large.LW2SPE** Cowhide leather, natural pigskin cuff .4 ( .18 )LWG2SPE** Goatskin leather, natural pigskin cuff .4 ( .18 )**Add “-M” for medium, “-L” for large, “-XL” for extra-large.316WSP-LLW2SPE312WI95/217 WHSS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401E-13


LINEMEN’S SLEEVESDippedRubber Insulating Sleeves extend coverage of the armfrom the cuff of rubber insulating gloves to the shoulderfullyprotecting these areas from accidental contact withenergized conductors and equipment. Salisbury sleevesfeature a reinforcing fold at the cuff. This fold is preferredover a rolled bead because it adds less bulk to thecuff and fits into the glove easier without pushing. Twodifferent processes are used to manufacture insulatingsleeves; dipping and molding. Both meet the currentrequirements of ASTM D1051 and offer the same highlevel of quality and protection.Dipped sleeves are manufactured in the same way asSalisbury rubber insulating gloves. Porcelain forms aredipped into liquefied rubber, dried, trimmed, marked andcured. Every sleeve receives the same quality inspectionsand electrical testing before shipping. Dipped sleeves areavailable in the same colors as dipped gloves, includingtwo color combinations.Salisbury is the only manufacturer that offers threepopular style of dipped lineman’s sleeves: straight, curved,and extra-curved. All styles are available in every color orcolor combination, size, and voltage class. Most importantly,all are made to the same rigid levels of qualitydemanded by Salisbury.Extra-Curved ArmD2LYR-ECCat. No. Breakdown for Dipped Type I SleevesVoltage Size ColorClassD0 R, L or XL Y=yellowD1 R, L or XL R=redD2 R, L or XL B=blackD3 R, L or XL YB=Y inside, B outD4 R, L or XL RB=R inside, B outR=regular L=large XL=extra large YR=Y inside, R outExample:D2LYBAdd suffix “-ST” to order straight cuff or “-EC” to order extra-curved cuffCurved ArmD2LYStraight ArmD2RYB-STE-14SALISBURY Gloves and Sleeves. www.wh<strong>salisbury</strong>.com


LINEMEN’S SLEEVESMoldedMolded sleeves are manufactured by eitherinjection or compression molding methods. Theadvantage these methods offer is the ability toproduce sleeves of Type I or SALCOR® TypeII synthetic rubber. SALCOR sleeves providethe same high quality and electrical protectionas natural rubber, with the added benefit ofbeing resistant to ozone and ultraviolet radiation.Type I sleeves are available in black,yellow or maroon. Type II SALCOR sleevesare black or orange. Molded sleeves areavailable in curved arm style only.BlackType I2RBCat. No. Breakdown for Molded Type I SleevesVoltage Size ColorClass1 R or L B2 R, L or XL B, Y3 R or L Y4 R or L MR=regular L=large XL=extra large B=black Y=yellowExample:2LBM=maroonCat. No. Breakdown for Molded Type II SleevesVoltage Size ColorClassYellowType I3LYOrangeType II2ROS1 R or L BS or OS2 R, L or XL BS or OSR=regular L=large XL=extra large BS=black SALCORExample:2LOS OS=orange SALCORS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401E-15


LINEMEN’S SLEEVESAccessoriesSleeves should be selected to fit the armcomfortably, covering from the top ofthe shoulder to inside the top of theglove. Regular size sleeves are theshortest and have the smallest arm andwrist openings. To minimize the possibilityof the sleeves pushing gloves offthe hand, size the sleeve to the shortestlength possible while maintainingcomplete coverage to the shoulder.B22B2B22 Two-piece sleeve buttonB2 One piece sleeve button4 required per pair of sleevesS1 13.5”(343mm) strap with buttonsS15 15”(381mm) strap with buttons2 straps required per pair of sleevesH1 Sleeve harness with buttons1 Harness required per pair of sleevesSizing Linemen’s SleevesSTRAIGHT ARM SLEEVE- Figure 1A B C Din. ( mm ) in. ( mm ) in. ( mm ) in. ( mm )Regular26.25 ( 667 ) 15.5 ( 394 ) 11.25 ( 286 ) 5.5 ( 140 )Large28.5 ( 724 ) 17 ( 432 ) 12.87 ( 327 ) 6.87 ( 175 )Extra Large30 ( 762 ) 19 ( 483 ) 13.25 ( 337 ) 6.87 ( 175 )Figure 1CURVED ARM SLEEVE- Figure 2A B C Din. ( mm ) in. ( mm ) in. ( mm ) in. ( mm )Regular26.5 ( 673 ) 15.5 ( 394 ) 12.25 ( 311 ) 5.25 ( 146 )Large27.75 ( 705 ) 16 ( 406 ) 12.87 ( 327 ) 6.87 ( 175 )Extra Large29.5 ( 749 ) 17.5 ( 445 ) 12.87 ( 327 ) 7 ( 178 )Figure 2E-16SALISBURY Gloves and Sleeves. www.wh<strong>salisbury</strong>.com


STORAGEFor Rubber InsulatingGloves and SleevesGB116GB116-GCT31T32Crush Resistant Lining of T32Proper storage extends the service lifeof linemen’s gloves and sleeves.Folds and creases strain rubber andcause it to crack from ozone prematurely.By storing rubber gloves andsleeves in the right size bag or roll-up,and never forcing more than one pairinto each bag, equipment will lie flatand last longer.Salisbury bags and roll-ups areconstructed of heavy duty canvasduck and are double stitched andriveted at stress points for extradurability. Canvas bags feature a Dring for hanging in trucks or on workbelts. Bags feature tapered gussetswith wide opening tops for easyinsertion. The T32 bag contains acrush resistant lining to create a moreprotective environment for yoursleeves. The Salisbury canvas sleeveroll is specifically designed to allowsafe storage of sleeves without severestraining or folding of the rubber.When rolled the sleeve roll can be hungin trucks to protect sleeves fromdamage.Cat. No. For Glove Dimensions Weight ea.length in. ( mm ) inches ( mm ) lbs. ( kgs )26 oz. CANVAS GLOVE BAGSGB112 11 ( 280 ) 9” x 14” ( 229 x 356 ) 1 ( .5 )GB114 14 ( 356 ) 9” x 16” ( 229 x 406 ) 1 ( .5 )GB116 16 ( 406 ) 9” x 18” ( 229 x 457 ) 1.2 ( .6 )GB118 18 ( 457 ) 9” x 20” ( 229 x 508 ) 1.5 ( .7 )26 oz. CANVAS GLOVE BAGS w/ goggle caseGB114-GC 14 ( 356 ) 9” x 16” ( 229 x 406 ) 1 ( .5 )GB116-GC 16 ( 406 ) 9” x 18” ( 229 x 457 ) 1.2 ( .6 )GB118-GC 18 ( 457 ) 9” x 20” ( 229 x 508 ) 1.5 ( .7 )#8 CANVAS GLOVE & SLEEVE BAG*2C16 14 ( 356 ) 16 ( 406 ) 9” x 18” ( 229 x 457 ) 1.2 ( .6 )2C18 18 ( 457 ) 9” x 20” ( 229 x 508 ) 1.5 ( .7 )#8 CANVAS SLEEVE BAGT31 - 33” x 9.5” ( 836 x 241mm) 1.5 ( . 7 )T32 - 33” x 9.5” ( 836 x 241mm) 3 ( 1.4 )14 oz. CANVAS SLEEVE ROLL-UPSR130 - 32” x 19” ( 813 x 482mm ) 1.4 ( . 6 )*Designed for use with SALCOR Type II sleeves only.Not recommended for natural rubber.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401E-17


HAND & GLOVE CLEANERS & POWDER10-4 1451 S-99 S55RUB-OUT is a non-petroleum-based handcleaner for workers who wear rubber glovesand sleeves. Dissolves and removes grease, oil,ink, tar, pipe dope, creosote, paint and morewithout harming rubber or SALCOR®. Cleanswith or without water. Contains natural skinconditioners and leaves a fresh citrus scent.Salisbury’s RUB-OUT Towelettes arepremoistened heavy duty hand cleaner towelsthat work fast to loosen, dissolve, and absorbdirt and grease, and will not harm rubbergloves! Our powerful yet safe cleaning agentswork together with an absorbent,nonscratching abrasive cleaning towel. Thecitrus-based formula easily removes soil fromyour hands and leaves them cleaned andconditioned anywhere you’re working. Andafter cleaning your hands there is enoughabsorbency to clean your tools and othersurfaces with the same towel. These shop size(10.5” x 12.25”) durable towels quickly removetough-to-clean substances including lubricants,tar, oils, wax, caulk and much more.TEN-FOUR GLOVE DUST is a cooling,frictionless powder that absorbs moisture andperspiration when wearing rubber gloves.Provides extra comfort while preventing glovesfrom getting sticky. The 6-oz. bottle easily fitsin a pocket or glove bag. The 4-quart bulkpackage is used in test labs as a dustingpowder when cleaning and testing.SUPER SALCO® is a concentrated detergentwith a special grease release formula thatremoves oils, grease and dirt from rubber and1460Cat. No. Description Weight ea.lbs. ( kgs )RUBOUT HAND CLEANER1450 4.5 oz. ( 130g ) tubes, 12/pack 4 ( 1.8 )1451 16 oz. ( .45kg ) can, 12/pack 16 ( 7.3 )1452 4.5 lbs. ( 2kgs ) cans, 6/pack 28 ( 12.7 )1453 Dispenser for 4.5lb. ( 2kg ) can 1 ( .5 )RUBOUT TOWELETTES1460 Bucket of 60, 6 buckets / Case 14 ( 6.4 )1461 Single Packets, 100 Singles / Case 3 ( 1.4 )TEN-FOUR GLOVE DUST10-4 12 @ 6 oz. ( 170g ) squeeze bottles 5.5( 2.2 )10-4-4QT 4 quarts ( 3.8 ltrs. ) bulk, single 8 ( 3.6 )SUPER SALCO DETERGENTS4 1 gal ( 3.8 ltr. ) jugs, 4 pack 54( 24.5 )S5 5 gal ( 19 ltr. ) drum 49 ( 22.3 )S55 55 gal ( 208 ltr. ) drum 540 ( 245 )SALCON SILICONE SPRAYS-99 Aerosol can 16 oz. ( .454 )SALCOR equipment. Suitable for washinglinemen’s rubber gloves, sleeves and otherspecialty equipment, by hand or in commercialwashing machines. Also works well on fiberglassand other materials. Just dilute with water,apply with a rag or sponge and rinse thoroughly.SALCON® Silicone Spray is specially formulatedto reduce friction on SALCOR or naturalrubber products. Reduces surface creepage onrubber gloves and sleeves. Forms an oxygenbarrier which helps reduce corona cutting andweather checking on rubber equipment. Mayalso be used to spray spark plugs and batteryterminals in damp weather to assist in starting.1461NEWE-18SALISBURY Gloves and Sleeves. www.wh<strong>salisbury</strong>.com


DIELECTRIC BOOTSASTM Dielectric FootwearSuper Dielectric - ANSI Z41 - Deep Heel OvershoesSuper Dielectric - ANSI Z41 - OvershoesDielectric - ANSI Z41 - OvershoesS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401F-1


ASTM DIELECTRIC FOOTWEARDeep Heel OvershoesASTM Dielectric Footwear provides extrasafety when climbing ladders and poles wherethe deep heel cavity can lock onto the rungs.These boots and overshoes are 100% waterproofand made from premium grade ozoneresistant rubber. The construction ishand-layered in full-cut patterns to fitover work boots. The fabric liningmakes them easy to get on and off.The sole has a durable constructionwith a non-skid bar tread outsole.Salisbury Dielectric Footwear conformswith ASTM F1117 and is testedto ASTM F1116 at 20,000 volts.5150951508ASTM Dielectric Footwear comes in fourstyles all with pole-climbing reinforcementpatch. The Storm Rubber Overshoe isavailable without buckles or with two buckles.The Full-Cut Overshoe with adjustable sidestrap features a 12” height or a 17” height.The attached buckle and hardware is nonmetallic.Manufactured in the U.S.A.2140521406Cat. No. Description Sizes Weight pr.in. ( mm ) lbs. ( kgs )21405 17”, 1 Buckle, Full Cut Overshoe Whole Sizes 7 - 17 5.8 ( 2.6 )21406 12” 1 Buckle, Full Cut Overshoe Whole Sizes 7 - 17 5.0 ( 2.3 )51509 2 Buckle Whole Sizes 7 - 17 4.4 ( 2 )51508 Storm Rubber Whole Sizes 7 - 17 3.3 ( 1.5 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401F-3


SUPER DIELECTRIC - ANSI Z41Deep Heel Overshoes, Tested to 20kVSuper Dielectric Deep Heel Overshoesprovide extra safety when climbing ladders andpoles where the deep heel cavity can lock ontothe rungs. These boots and overshoes are madefrom an ozone resistant yellow rubber that’s100% waterproof. The construction is handlayeredin full-cut patterns to fit over workboots. The fabric lining makes them easy get onand off. The sole is an anti-skid bar thread. Allof these overshoes and boots have been testedto the electrical hazard requirements of ANSIZ41 1999. Super Dielectric footwear has beentested to 20,000 volts.5158151530Super Dielectric Deep Heel Overshoes come inthree styles all with pole-climbing reinforcementpatch. The Storm Rubber Overshoe isavailable without buckles or with two buckles.The Full-Cut Overshoe with adjustable sidestrap features a 17” height.Anti-SkidBar Tread21402Cat. No. Sizes Description Weight pr.in. ( mm ) lbs. ( kgs )51581 Whole & Half Sizes 7-12, Whole 5, 6, 13-17 Storm Rubber 3.3 ( 1.5 )51530 Whole Sizes 6-17 2-Buckle 4.4 ( 2 )21402 Whole Sizes 7-17 17” ( 432 ) Overshoe 5.8 ( 2.6 )F-4SALISBURY Dielectric Boots. www.wh<strong>salisbury</strong>.com


SUPER DIELECTRIC - ANSI Z41Overshoes, Tested to 20kVSuper Dielectric Overshoes are madefrom an ozone resistant yellow rubber.The construction is hand-layered in fullcutpatterns to easily fit over workboots. These overshoes are 100%waterproof. The lining is fabric so theyeasily slip on and off. The sole is ananti-skid bar tread. All of these overshoesand boots have been tested to theelectrical hazard requirements of ANSIZ41 1999. Super Dielectric footwear hasbeen tested to 20,000 volts.51824Super Dielectric Overshoes are availablein two styles: a Storm Rubber Overshoeand an 11” 4-Buckle Arctic both with apole-climbing reinforcement patch.31924Anti-SkidBar TreadCat. No. Sizes Description Weight pr.in. ( mm ) lbs. ( kgs )31924 Whole Sizes 6-17 11” ( 279 ) 4-Buckle Arctic 4.6 ( 2.1 )51824 Whole & Half Sizes 7-12, Whole 13-17 Storm Rubber 3.25 ( 1.5 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401F-5


DIELECTRIC - ANSI Z41Overshoes, Tested to 14kVDielectric Overshoes are made from yellowozone resistant rubber that’s 100% waterproof.The construction is hand-layered in full-cutpatterns to easily slip over work shoes. Thelining is fabric so they easily slip on and off. Allof these overshoes and boots have been testedto the electrical hazard requirements of ANSIZ41 1999. These overshoes have been tested to14,000 volts.Diamond V-gripOutsole51510Dielectric Overshoes come in two styles. TheDeep Heel Lineman’s Storm Rubber has adiamond V-grip outsole and pole-climbingreinforcement patch. The 11” 4-Buckle has ananti-skid bar tread sole and heel.Anti-SkidBar Tread31910Cat. No. Sizes Description Weight pr.in. ( mm ) lbs. ( kgs )51510 Whole & Half Sizes 6-12, Whole 13-17 Deep Heel Storm Rubber 3.1 ( 1.4 )31910 Whole Sizes 7-17 11” ( 279 ) 4-Buckle 3.8 ( 1.7 )F-6SALISBURY Dielectric Boots. www.wh<strong>salisbury</strong>.com


INSULATED JUMPERSInsulated Jumper Clamps - IntroductionSure-lok Jumper ClampsNon-Locking SALCOR® Insulated Jumper ClampsNon-Locking Clear Plastic Insulated Jumper ClampsNon-Locking FRP Insulated Jumper ClampsStick Installed Flexible JumpersFlexible Insulated Jumper CablesFerrulesInsulated Jumper AccessoriesS ALISBURYInsulated Jumper AccessoriesSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401G-1


INSULATED JUMPERSInsulated bypass jumper sets consist ofthree basic components: one pair ofclamps, one pair of ferrules, and alength of insulated cable. Many of themost popular jumper sets are listed onthe following pages associated with eachof the different types of jumper clamps.When a custom jumper is required,follow this procedure to ensure that acomplete and functional jumper isspecified.All Salisbury Insulating Jumpersmeet ASTM F2321 standards.Insulated Jumper Checklist1. Clamp3. Cable2. Ferrules1. Specify the style of insulated clamps. All of the clamps are hand installedwearing rubber insulating gloves, accept either shrouded or unshroudedferrules, and accept insulated cable up to 4/0, 35kV. Insulated jumper clampsare sold in pairs.2. Specify the size and length of insulated cable. Salisbury offers 15kV cablefrom #2 to 4/0. 25 and 35 kV cable are both available in sizes 1/0 and2/0. Be sure to specify the length of the cable chosen.3. Specify the size and style of ferrules required. The size of the ferrule will bedetermined by the size of the cable. Specify the appropriate ferrule catalognumber for either shrouded or unshrouded ferrules. Both types are sold inpairs.4. Specify if the jumpers are to be factory assembled, add the suffix “A” to theend of the clamp and ferrule catalog numbers. A complete jumper set withcrimped ferrules and installed jumper clamps will be supplied.5. Specify if there are any special requirements. This could include heat shrinktubing, special assembly instructions, markings, packaging etc.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401G-3


NEWLOCKING INSULATED JUMPER CLAMPSThe Salisbury Sure-lokJumper ClampSetting industry standards in 2004The New Salisbury Sure-lok Jumper clamp is arevolutionary improvement over any other jumperclamp in the world. Featuring a ratchet typelocking mechanism (patent pending), this is theonly clamp available guaranteed not toloosen once installed on a line.Loose Jumper clamps not only jeopardize yoursafety but can also cause fires and power outages.Even when torqued using wrenches or pliers,traditional clamps will eventually loosen fromline vibrations and thermal cycling. Thisclamp tightens with a ratchet action using onehand, with no extra tools for a secure,positive connection. It can't come loose untilyou want it to. Pull and turn the lockingknob and it loosens like any traditionalclamp.Available in our exclusive Salcor Type IImaterial and the industry’s most durablesingle piece clear plastic jumper clamps.NEWSALCOR Sure-lokCat. No. Main Line Max Amps Rating OAL Length Weight ea.Range Continuous in. ( mm ) lbs. ( kgs )SALCOR2261* 477 MCM (.9”-.162”) 400 36 kV Ø-Ø 11.5 ( 292 mm ) 4.8 ( 2.2 )2271* 954 MCM (1.25”-.162”) 400 21 kV Ø-GRD 11.5 ( 292 mm ) 5.9 ( 2.7 )Clear Plastic1786* 477 MCM (.9”-.162”) 400 36 kV Ø-Ø 11.5 ( 292 mm ) 3.9 ( 1.8 )2116* 954 MCM (1.25”-.162”) 400 21 kV Ø-GRD 11.5 ( 292 mm ) 4.9 ( 2.2 )* If requesting a 10ft. Sure-lok Assembly Set; see page G-5 & G-6 for product information and catalog numberG-4SALISBURY Insulated Jumpers. www.wh<strong>salisbury</strong>.com


NON-LOCKING SALCOR INSULATED JUMPER CLAMPSSALCOR® Jumper Clamps are available intwo main line sizes with a maximum usevoltage of 35kV.The SALCOR Jumper Clamp not onlyprovides a superior grip, but also resists ozonecutting and tracking. Being molded of rubber,these handles are inherently impact resistantand extremely durable. The body and jaw aremade from a copper base alloy. The lowerring contact is made of self lubricatingbronze. Assemble jumpers with insulatedjumper cable and 5/8”- 11 NC threadedferrules. The assembled kits are sold with a10 ft. ( 3m ) cable and unshrouded ferrules.22602270Cat. No. Main Line Max Amps Rating OAL Length Weight ea.Range Continuous in. ( mm ) lbs. ( kgs )2260 477 MCM (.9”-.162”) 400 36 kV Ø-Ø 11.5 ( 292 mm ) 4.8 ( 2.2 )2270 954 MCM (1.25”-.162”) 400 21 kV Ø-GRD 11.5 ( 292 mm ) 5.9 ( 2.7 )Add suffix “A” when requesting a custom hot jumper; see the Insulated Jumper Checklist on page G-3 for ordering instructions2260 Clamp2270 ClampAssembled 10 ft. / 3m Jumper Sets ( Unshrouded Ferrules)Jumper Cable Size Cable Ferrule Max Amps Weight ea.Cat. No. Cat. No. Cat. No. Continuous lbs. ( kgs )2264* #2-15 kV 2754 2022 200 10.9 ( 4.9 )2265* 1/0-15 kV 2755 2023 250 13.5 ( 6.1 )2266* 2/0-15 kV 2756 2024 300 14.8 ( 6.8 )2274* #2-15 kV 2754 2022 200 11.9 ( 5.4 )2275* 1/0-15 kV 2755 2023 250 14.6 ( 6.8 )2276* 2/0-15 kV 2756 2024 300 15.9 ( 7.2 )* Add suffix “S” when requesting a 10ft. Sure-lok Assembly Set; see page G-4 for product informationS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401G-5


NON-LOCKING CLEAR PLASTIC INSULATED JUMPER CLAMPSClear Plastic Jumper Clamps areavailable in two main line sizes with amaximum use voltage of 35kV. Assemblethese clamps with insulatedjumper cable and 5/8” - 11 NC threadedferrules.Clear Plastic Jumper Clamps arecompact, lightweight, and virtuallyunbreakable. The transparency allowseasy inspection of the ferrule and cableinside of the handle. The body and jaware made from a copper base alloy. Thelower floating ring contact is bronze.These handles should be cleaned onlywith a mild detergent to maintain thetransparency of the handle. Theassembled kits are sold with a 10 ft.(3m) cable and unshrouded ferrules.2115Clear Jumperwith Cable1785Cat. No. Main Line Max Amps Rating OAL Length Weight ea.Range Continuous in. ( mm ) lbs. ( kgs )1785 477 MCM (.9”-.162”) 400 36 kV Ø-Ø 11.5 ( 292 mm ) 3.9 ( 1.8 )2115 954 MCM (1.25”-.162”) 400 21 kV Ø-GRD 11.5 ( 292 mm ) 4.9 ( 2.2 )Add suffix “A” when requesting a custom hot jumper; see the Insulated Jumper Checklist on page G-3 for ordering instructionsAssembled 10 ft. / 3m Jumper Sets ( Unshrouded Ferrules)Jumper Cable Size Cable Ferrule Max Amps Weight ea.Cat. No. Cat. No. Cat. No. Continuous lbs. ( kgs )1785Clamp2067* #2-15 kV 2754 2022 200 9.9 ( 4.5 )2178* 2/0-15 kV 2756 2024 300 13.9 ( 6.3 )2115 Clamp2074R1* #2-15 kV 2754 2022 200 10.9 ( 4.9 )2164* 2/0-15 kV 2756 2024 300 14.8 ( 6.8 )2174R1* 1/0-15 kV 2755 2023 250 16.8 ( 7.6 )* Add suffix “S” when requesting a 10ft. Sure-lok Assembly Set; see page G-4 for product informationG-6SALISBURY Insulated Jumpers. www.wh<strong>salisbury</strong>.com


NON-LOCKING FRP INSULATED JUMPER CLAMPSFRP Jumper Clamps are designed for maximumloads, voltages, and cables. During atemperature rise test at 25% overload, theseclamps heated 35% less than 4/0 cu. cable.Blunted points on the handle provide optimumgrip, resist impact, and will not soften withoverloads. The body and jaw are made from acopper based alloy. The lower jaw is made ofself lubricating bronze. The assembled jumpersare sold with a 10ft. (3m) or 12 ft. (3.7m) cableand unshrouded ferrules.1610Cat. No. Main Line Max Amps Rating OAL Length Weight ea.Range Continuous in. ( mm ) lbs. ( kgs )1610 954 MCM (1.25”-.162”) 400 36 kV Ø-Ø 11 ( 279 ) 6.4 ( 2.9 )21 kV Ø-GRDAssembled Jumper Sets ( Unshrouded Ferrules)Jumper Cable Length Cable Size Cable Ferrule Max Amps Weight ea.Cat. No. Cat. No. Cat. No. Continuous lbs. ( kgs )1610 Clamp2772 10’ 2/0-15kV 2756 2024 300 5.8 ( 2.9 )2773 10’ 4/0-15kV 2757 2025 400 20.3 ( 9.2 )2450 10’ 1/0-15kV 2755 2023 250 15 ( 6.8 )2066 12’ 1/0-35kV 2059 2023 250 20.3 ( 9.2 )20876 12’ 2/0-35kV 4370 2024 300 21.5 ( 9.8 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401G-7


NON-LOCKING STICK INSTALLED FLEXIBLE JUMPERSStick Installed Flexible Jumperscan be manufactured for hot stickoperations using Salisbury heavydutyeye clamps. Clamps are ratedfor continuous current and fit allstandard shotgun type hot sticks.For ease of application, a HangerStud is recommended. Shroudedferrules are not recommended foruse with eye type clamps.2300Cat. No. Main Line Max Amps Components Rating Weight ea.Range Continuous lbs. ( kgs )2300 250 2#1895A Alum “C” Clamp 1#1928A Hanger Stud 15 kV Ø-Ø 15.9 ( 7.2 )1431 ACSR 1#2027A Alum Ferrule 10’ #2755 1/0 15kV Cable2308 200 2#1895A Alum “C” Clamp 1#1928A Hanger Stud 15 kV Ø-Ø 10.8 ( 4.9 )1#2026A Alum Ferrule 12’ #2754 #2 15kV Cable2317 to #6 Sol. 250 2#2195A Alum “C” Clamp 1#1928A Hanger Stud 35 kV Ø-Ø 16 ( 7.3 )1#2027A Alum Ferrule 12’ #2059 1/0 35kV Cable2318 1.5”- .16” 300 2#2318A Alum “C” Clamp 1#1928A Hanger Stud 15 kV Ø-Ø 15.6 ( 7.1 )1#2620A Alum Ferrule 12’ #2756 2/0 15kV Cable2513 1033 ASCR 250 2#1893A Alum “C” Clamp 1#1928A Hanger Stud 15 kV Ø-Ø 16.1 ( 7.3 )to #6 Sol.1#2027A Alum Ferrule 10’ #2755 1/0 15kV Cable2559 1.25”- .16” 250 2#1853A Alum Duckbill Clamp 1#1858A Hanger Stud 15 kV Ø-Ø 15.7 ( 7.1 )1#2027A Alum Ferrule 10’ #2755 1/0 15kV Cable2877 795 ASCR 250 2#2532A Alum “C” Clamp 1#2537A Hanger Stud 15 kV Ø-Ø 11 ( 5.0 )1#2027A Alum Ferrule 10’ #2755 1/0 15kV Cable9976 to #8 Sol. 250 2#9985A Brnz “C” Clamp 1#9983A Hanger Stud 15 kV Ø-Ø 12 ( 5.4 )1#2023A Cu Ferrule 10’ #2755 1/0 15kV Cable9977 1.12”- .12” 250 2#2937A Brnz “C” Clamp 1#9983A Hanger Stud 35 kV Ø-Ø 12.5 ( 5.6 )1#2023A Cu Ferrule 10’ #2059 1/0 35kV CableG-8SALISBURY Insulated Jumpers. www.wh<strong>salisbury</strong>.com


NON-LOCKING FLEXIBLE INSULATED JUMPER CABLESFlexible Insulated Jumper Cables arelightweight and resistant to oil, heat, moisture,ozone and abrasion. The cable is embossedevery three feet with conductor size and kVrating.All jumper cables use fine stranded conductorand a new EPR low temperature Unipassorange CV cured jacket. The fine strandedcopper conductor is alloy coated and assembledin a unidirectional rope lay for extraflexibility. The conductor has a semiconductingshield surrounding it to relieve voltage stressand improve dielectric strength and service life.Cable insulation, shield and conductor aremanufactured and factory tested to meet orexceed ICEA S68-516.15kV 25kV 35kV4/0 2/0 1/0 #2 1/0 2/0 1/0 2/0Cat. Size & Str. kV Rating Nominal Str. Dia. O.A. Dia. Max Amps Weight per 1000 ft.No. AWG Ø to Ø Ø to Grd in. ( mm ) in. ( mm ) Continuous lbs. kgs2754 #2-259W 15 10 .320 ( 8.1 ) .75 ( 19 ) 200 440 1992755 1/0-413W 15 10 .403 ( 10.2 ) .83 ( 21 ) 250 600 2722756 2/0-427W 15 10 .456 ( 11.5 ) .90 ( 23 ) 300 710 3222757 4/0-437W 15 10 .592 ( 15.0 ) 1.01 ( 25.6 ) 400 1050 47621300 1/0-413W 25 15 .403 ( 10.2 ) 1.06 ( 27 ) 250 650 29521060 2/0-427W 25 15 .456 ( 11.5 ) 1.10 ( 28 ) 300 750 3412059 1/0-413W 35 20 .403 ( 10.2 ) 1.22 ( 31 ) 250 950 4314370 2/0-427W 35 20 .48 ( 12.1 ) 1.31 ( 33.1 ) 300 1060 482S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401G-9


NON-LOCKING FERRULESShrouded / UnshroudedFerrules are manufactured in twodifferent styles: unshrouded andshrouded. Shrouded ferrules are compressedon both the conductor and theinsulating jacket of the high voltage EPRcable to reduce bending stress. Shroudedferrules are designed to be used on gloveinstalledhigh voltage jumpers.Unshrouded ferrules are crimped theconductor strands only and can be usedon either stick- or glove-installed jumpers.Ferrules are manufactured of 99.5%pure copper with industry standard 5/8”-11 NC threads. Ferrules are topped with abrass hex jam nut and toothed stainlesssteel lockwasher. The continuous currentrating is 400 Amps.shroudedunshroudedCat. No. Cable Size Strand Die Codes Jacket Die Codes Weight ea.Pair T&B T&B lbs. ( kgs )SHROUDED2012 2-15 kV ERP 66 106 1.2 ( .5 )2013 1/0-15 kV ERP 66 106 1.2 ( .5 )2014 2/0-15 kV ERP 66 106 1.1 ( .5 )2015 4/0-15 kV ERP 66 106 0.9 ( .4 )21353 1/0-25 kV 66 112 1.1( .5 )21354 2/0-25 kV 66 112 1.1 ( .5 )21355 1/0-35 kV 66 125 1.1 ( .5 )21356 2/0-35 kV 66 125 1.1 ( .5 )UNSHROUDEDStrand Die Codes2022 #2 50 - 0.5 ( .2 )2023 1/0 50 - 0.4 ( .2 )2024 2/0 60 - 0.4 ( .2 )2025 4/0 66 - 0.6 ( .3 )Add suffix “A” when requesting a custom hot jumper; see the Insulated Jumper Checklist on page G-3 for ordering instructionsG-10SALISBURY Insulated Jumpers. www.wh<strong>salisbury</strong>.com


NON-LOCKING INSULATED JUMPER ACCESSORIESThe Connector Link connects twoinsulated jumpers to create a longerjumper length. After the two clamps areconnected to the link, the assembly canbe wrapped with a small rubber insulatingblanket.2750Stirrup Clamps are used to convert ahand installed jumper into a stickinstalled jumper. The stirrup is designedto accept all conventional jumper heads.21132 RGCat. No. Main Line Description Max. Amps Weight ea.Range Continuous lbs. ( kgs )2750 --- Connector Link 400 .3 ( .1 )21132RG 1033 MCM ASCR to #6 Sol. Hot Jumper Stirrup Clamp 400 3.0 ( 1.4 )1.25”-.16” ( 32-4.1mm )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401G-11


NON-LOCKING INSULATED JUMPER ACCESSORIESThe Hot Jumper Parking Stand safelyholds either hand or stick installed hotbypass jumpers. This insulated tool removesthe risk of accidental contact withthe uninstalled end of an energized jumper.Installs by hand using rubber insulatinggloves or with a standard shotgun stick.The fiberglass jumper hanger bar willaccommodate standard size mechanicaljumper heads.4245The Insulated Double Hanger ParkingStud is used for electrically isolating one orboth ends of a jumper. It can be used shortterm or long term. The applications rangefrom a short term parking place for atemporary hot or grounding jumper to along term sectionalizing apparatus. It canalso be used as a circuit by attaching thehot line clamp of the line jumper to theinsulated hanger stud.26232270 connected to 4245Cat. No. Main Line Description Max. Weight ea.Range Amps lbs. ( kgs )4245 954 MCM ACSR to #6 Sol. Parking Stand for Hot Jumpers n / a 3.5 ( 1.6 )1.14”- .16” ( 29- 4.1 mm )Cat. No. Rating Number of Line Size Distance in. ( mm ) Weight ea.Ø to Ø Sheds Range Line to Stud lbs. ( kgs )2623 15 4 1033 KCM 24 (610) 3.7 (1.7)2624 27 6 ACSR-6 Sol. 24 (610) 4.1 (1.9)2625 35 8 1.25”-16” 24 (610) 4.6 (2.1)(31.8-4.1mm)G-12SALISBURY Insulated Jumpers. www.wh<strong>salisbury</strong>.com


GROUNDING EQUIPMENTGrounding Equipment - IntroductionDuck Bill Grounding Clamps“C” Type Grounding ClampsGrounding Clamps for Substation BusesGrounding Clamps for Flats, Angles and RoundsSpecialty ClampsPressure Terminal Type ClampsPlain Shrouded and Unshrouded FerrulesBall and Socket SystemGrounding Clamp Hanger StudsGrounding SetsGrounding CablesGrounding FerrulesConductor and Cleaning ToolsGrounding AccessoriesVoltage DetectorsHydraulic Cable SpikesS ALISBURYStatic Discharge StickASTM TablesSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401H-1


Our complete line of grounding equipment offerssolutions for utility and industrial applications.Whether you prefer complete jumper assembliesor individual components, Salisbury has a productmanufactured to the highest industry standards tomeet your needs.Salisbury’s Grounding ConfiguratorSalisbury’s Grounding Configuratormakes ordering grounding equipmentsimple and easy. This interactive web toolallows you to easily build the propertemporary grounding equipment for yourspecific needs. The step by step processtakes out the guess work, and makes iteasy to change components until the mostappropriate ground set is developed.Just go to our web site and give it a try.You will be prompted from start to finish.All you need to know is the maximum fault current, its duration and the size of cablerequired on the fault, and the configurator will do the rest. No more second guessingquantities or parts to be sure that you have put together a ground set that will functionjust as you expect. When you finish, enter your personal information and theconfigurator will instantly provide you with the bill of materials including part numbers.All that’s left to do is to place the order!Visit wh<strong>salisbury</strong>.com/configurator to use Salisbury’sexclusive Grounding Configurator TM .H-2SALISBURY Grounding Equipment. www.wh<strong>salisbury</strong>.com


GROUNDING EQUIPMENTHow to specify grounding jumpers.A grounding jumper in its basic formconsists of two clamps, one pair of ferrulesand a length of cable.The clamps can be identical to each otheror quite different depending on eachgrounding application. Because of this,ground clamps are sold individually, notin pairs. Salisbury offers a wide varietyof clamps including C-clamps, flat jawclamps, socket clamps, duckbill clampsand specialty clamps for unique situations.Clamps are offered in either bronzeor aluminum alloys and are manufacturedto meet the current specifications of ASTMF 855. All clamps are tapped to accept a 5/8-11 UNC threaded stud.To attach a clamp to the grounding cablerequires the use of a ferrule. Ferrulesare compressed on the strands of thecable to provide a low resistance permanentconnection. The size of the ferruleis determined by the size of thecable. Ferrules are available in aluminumor copper and can be used with eitheraluminum or bronze clamps. Two ferrulesare required for each jumper thereforethey are sold in pairs. Ferrules aremanufactured to the specifications ofASTM F 855.The final component that makes up aground set is the grounding cable itself.The size of the cable is dependent onthe short circuit current capacity of thesystem being grounded. Once this is determined,only the length of the cable andthe color of the jacket need to be specifiedto complete the jumper.3. Ferrules1.“C” ClampGround Set Checklist2. Cable1. Flat Jaw Clamp3. Ferrules1. Specify the clamps. Two are required for a complete jumper. The maximumamperage of the clamp is designated by the ASTM grade of each clamp. Be surethat the clamp will meet or exceed the maximum amperage rating of the groundcable that it will be used with.2. Specify the cable. Once the short circuit capacity of the system has been determined,choose the appropriate size cable. Specify the cable length, and the colorof the jacket desired.3. Specify the ferrules. One pair of ferrules is required per jumper. The size of theferrule must match the size of the cable that it will be used with. Specify whethercopper or aluminum, and threaded or plain.4. Specify the options. List any optional equipment that is desired. This can includehanger studs, contact studs, heat shrink tubing, markings, clear strain relief, etc.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401H-3


DUCK BILL GROUNDING CLAMPS1793NEWNEW21030 1853Cat. No. & Description ASTM Main Line Continuous Weight ea.Grade / Class Range Current Rating lbs. ( kgs )B R O N Z E556 KCM SMOOTH JAW BRONZE DUCK BILL --Gravity Actuated - “V” Thread1793 Eye 1.3 ( .6 )w/ strain relief sleeve 556 MCM ACSR21080 Eye 4 / A to #6 350 RMS Amps 1.1 ( .5 )w/o strain relief sleeve Smooth Jaw 60 Hz1797 Mounted* .96” - .16” 4.3 ( 2 )w/ strain relief sleeve 24mm - 4mm Dia.2093 Hanger Stud only .4 ( .1 )21081 - Stick MountedDuck Bill ClampA L U M I N U M1.1” SMOOTH JAW ALUMINUM DUCK BILL --Spring Loaded - “V” Thread21030 Eye 1.1 ( .5 )w/ strain relief sleeve 795 KCM ACSR21059 Eye 5 / A to #6 400 RMS Amps 1.0 ( .5 )no strain relief sleeve Smooth Jaw 60 Hz21081 Mounted* 1.1” - .16” 4.5 / 2 4.3 ( 2 )w/ strain relief sleeve 28mm - 4mm Dia.21574 Hanger Stud only .3 ( .1 )1.66” SERRATED JAW ALUMINUM DUCK BILL --Spring Loaded - “V” Thread2553 Eye 1033.5 MCM ACSR 1.4 ( .6 )no strain relief sleeve 5 / B to #6 400 RMS Amps1855 Mounted* Serrated Jaw 60 Hz 4.7 ( 2.1 )1853 Eyew/ strain relief sleeve 1.26” - .16”32mm - 4mm Dia.w/ strain relief sleeve 1590 MCM ACSR 1.5 ( .7 )5 / B to #6 400 RMS AmpsSerrated Jaw 1.65” - .16” 60 Hz42mm - 4mm Dia.21574 Hanger Stud only .3 ( .1 )*Mounted: 1.25” dia x 6’ Fiberglass Hot Stick permanently mountedH-4SALISBURY Grounding Equipment. www.wh<strong>salisbury</strong>.com


“C” TYPE GROUNDING CLAMPS42004388 99854187Cat. No. & Description ASTM Main Line Continuous Weight ea.Grade / Class Range Current Rating lbs. ( kgs )NEW4200 NOWGRADE 5B R O N Z E477 MCM BRONZE “C” CLAMP w/ Curved Lower Jaw - “V” Thread4200 Eye 1.1 ( .5 )w/ strain relief sleeve 5 / A 477 MCM 18 x 1 ACSR21067 Eye Smooth Jaw to 1.0 ( .4 )no strain relief sleeve #8 400 RMS Amps4260 Eye 60 Hz 1.1 ( .5 )w/ strain relief sleeve 5 / B .81” - .12”21068 Eye Serrated Jaw 21mm - 3mm Dia. 1.0 ( .4 )no strain relief sleeve2093 Hanger Stud only .4 ( .2 )A L U M I N U M1” ALUMINUM “C” CLAMP - Acme thread2531 Eye 1.1 ( .5 )w/ strain relief sleeve 5 / A 795 MCM 26 x 7 ACSR2532 Eye Smooth Upper Jaw to 1.1 ( .5 )no strain relief sleeve w/ #82533 Mounted* Flat Lower Jaw 400 RMS 4.2 ( 19 )w/ strain relief sleeve 60 Hz4388 Eye 5 / B 1.12” - .12” 1.5 ( .7 )w/ strain relief sleeve Smooth Upper Jaw 25mm - 3mm Dia.4389 Eye w/ 1.1 ( .5 )no strain relief sleeve Curved Lower Jaw2537 Hanger Stud only .2 ( .1 )B R O N Z E1” Bronze “C” Clamp - Acme thread9985 Eye 1.9 ( .9 )w/ strain relief sleeve 795 MCM 26 x 7 ACSR2937 Eye 5 / A to 1.8 ( .8 )no strain relief sleeve Smooth Jaw #8 400 RMS Amps4280 Mounted* 60 Hz 4.9 ( 2.2 )w/ strain relief sleeve 1.12” - .12”4187 Eye 5 / B 25mm - 3mm Dia. 1.9 ( .9 )w/ strain relief sleeve Serrated Jaw2537 Hanger Stud only .4 ( .2 )*Mounted: 1.25” dia x 6’ Fiberglass Hot Stick permanently mountedS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401H-5


“C” TYPE GROUNDING CLAMPS1.25” and 1.5” SizesB R O N Z E9984 4255Cat. No. & Description ASTM Main Line Continuous Weight ea.Grade / Class Range Current Rating lbs. ( kgs )1.25” BRONZE “C” CLAMP - Acme Thread9984 Eye 5 / A 2.2 ( 1.0 )w/ strain relief sleeve Smooth Jaw1897 Eye w/ 2.1 ( .9 )no strain relief sleeve Flat Lower Jaw 1035.5 KCM ACSR4255 Eye 5 / A to #6 2.2 ( 1.0 )w/ strain relief sleeve Smooth Jaw 400 RMS Amps21069 Eye w/ 60Hz 2.1 ( .9 )no strain relief sleeve Curved Lower Jaw 1.26 “ - .16”4279 Eye 5 / B 32mm - 4mm Dia. 2.2 ( 1.0 )w/ strain relief sleeve Serrated Jaw21070 Eye w/ 2.1 ( .9 )no strain relief sleeve Curved Lower Jaw9983 Hanger Stud only .4 ( .2 )42791895A L U M I N U M1.5” ALUMINUM “C” CLAMP, w/ flat lower jaw - Acme Thread4307 Eye strain relief 1.8 ( .8 )sleeve & lrg oval eye 5 / A2195 Eye Smooth Jaw 1.5 ( .7 )no strain relief sleeve1896 Mounted* 1431 KCM ACSR 4.8 ( 2.1 )w/ strain relief sleeve to #61895 Eye 400 RMS Amps 1.7 ( .8 )w/ strain relief sleeve 60 Hz4306 Eye strain relief 1.5” - .16” 1.8 ( .8 )sleeve & lrg oval eye 5 / B 38mm - 4mm Dia.2193 Eye Serrated Jaw 1.5 ( .7 )no strain relief sleeve1894 Mounted* 4.7 ( 2.1 )w/ strain relief sleeve1928 Hanger Stud only .2 ( .1 )*Mounted: 1.25” dia x 6’ Fiberglass Hot Stick permanently mountedH-6SALISBURY Grounding Equipment. www.wh<strong>salisbury</strong>.com


“C” TYPE GROUNDING CLAMPS2” Sizes2107520882Cat. No. & Description ASTM Main Line Continuous Weight ea.Grade / Class Range Current Rating lbs. ( kgs )A L U M I N U M2 “ ALUMINUM “C” CLAMP w/ Curved Lower Jaw - Acme Thread21075 Eye 2 ( .9 )w/o strain relief sleeve 5 / A 3000 KCM ACSR21074 Eye Smooth Jaw 2.1 ( 1.0 )w/ strain relief sleeve to #620882 Eye 400 RMS Amps 2.1 ( 1.0 )w/ strain relief sleeve 5 / B21077 Eye Serrated Jaw 2”-.16” 60 Hz 2 ( .9 )w/o strain relief sleeve 51mm - 4 mm1928 Hanger Stud only .2 ( .1 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401H-7


“C” TYPE GROUNDING CLAMPS2.4” Size19234377 19214390 4295Cat. No. & Description ASTM Main Line Continuous Weight ea.Grade / Class Range Current Rating lbs. ( kgs )A L U M I N U M2.4 “ ALUMINUM “C” CLAMP w/ Flat Lower Jaw - Acme Thread1923 Eye 2.1 ( 1.0 )w/ strain relief sleeve4377 Eye strain relief 2.1 ( 1.0 )sleeve & lrg oval eye 5 / A4240 Eye Smooth Jaw 2.0” I.P.S. 2.0 ( 1.0 )no strain relief sleeve to #61924 Mounted* 5.1 ( 2.3 )w/ strain relief sleeve 400 RMS Amps1921 Eye 60 Hz 2.2 ( 1.0 )w/ strain relief sleeve 2.4” - .16”4390 Eye strain relief 5 / B 61mm - 4mm Dia. 2.2 ( 1.0 )sleeve & lrg oval eye Serrated Jaw1922 Mounted* 5.2 ( 2.3 )w/ strain relief sleeve1928 Hanger Stud onlyStick Mounted“C” Type ClampB R O N Z E2.4” BRONZE “C” CLAMP w/ flat lower jaw - Acme Thread4295 Eye 2.0 “ I.P.S. to #6 4.1 ( 1.8 )w/ strain relief sleeve 5 / A 400 RMS Amps4311 Eye Smooth Jaw 2.4” - .16” 60 Hz 4.0 ( 1.7 )no strain relief sleeve61mm - 4 mm Dia.*Mounted: 1.25” dia x 6’ Fiberglass Hot Stick permanently mountedH-8SALISBURY Grounding Equipment. www.wh<strong>salisbury</strong>.com


GROUNDING CLAMPSFOR SUBSTATION BUSES428243412991Cat. No.& Description ASTM Main Line Continuous Weight ea.Grade / Class Range Current Rating lbs. ( kgs )A L U M I N U M3.5” ALUMINUM “C” CLAMP for Substation Buses - Acme Thread4282 Eye 3” - 1.5” I.P.S. 2.8 ( 1.3 )w/ strain relief sleeve4283 Mounted* 5 /A 3.5” - 1.75” 5.8 ( 2.5 )w/ strain relief sleeve Smooth Jaw 89mm - 44mm Dia. 400 RMS Amps4341 Eye, strain relief w/ 3” I.P.S. to #6 60 Hz 2.9 ( 1.4 )sleeve & long eye screw Flat Lower Jaw 3.5” - .16”(Main line range 3.5”-.16”(89-4mm)89mm - 4 mm Dia.6.62” ADJUSTABLE ALUMINUM “ C “ CLAMP for Substation Buses - Acme Thread2991 Eye 6.9 ( 3.1 )w/ strain relief sleeve 6.12” I.P.S.2993 Eye** 5 / A 6.62” - .4” 7.0 ( 3.2 )w/ single contact stud Smooth Jaw 168mm - 10mm Dia. 400 RMS Amps9967 Eye** w/ 60 Hz 7.3 ( 3.3 )w/ double contact stud Flat Lower Jaw Round, Square4378 Eye, strain relief Rectangle or 6.9 ( 3.1 )sleeve & lrg oval eyeH Section*Mounted: 1.25” dia x 6’ Fiberglass Hot Stick permanently mounted**No Ferrule ConnectionS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401H-9


GROUNDING CLAMPSFor Flats, Angles & RoundsFlat Jaw Grounding Clamps are availablewith either a large 4 inch “T” handle or withan eye for clampstick application. The handlesand eyes are designed so that the cable willnot interfere with the torquing of the clamp.The set screw that secures the clamp to a flatsurface is located on the movable jaw on alldesigns. When tightened, the set screw forcesthe fixed jaw of the clamp firmly against theflat ensuring a consistent low resistancecurrent path directly through the body of theclamp to the cable connection. With otherdesigns having a set screw on the fixed jaw,current is required to flow through mechanicalconnections between the movable jaw, the eyescrew, and the body of the clamp beforepassing to the cable connection.“C” Clamps, recommended for use with thegrounded end of jumpers, are equipped withan eye / “T” screw for added versatility.181443451815 4242 9993436924441 24442NEWNEWCat. No. & Description ASTM Main Line Continuous Weight ea.Grade / Class Range Current Rating lbs. ( kgs )BRONZEGRADE 3 BRONZE FLAT JAW Grounding Clamps - “V” Thread1814 “T” w/ strain 1.5” - .06” 1.7 ( .8 )sleeve & “T” screw 3 / B Flat or Square 300 RMS Amps1815 Eye w/ strain Serrated Jaw 1.26” - .06” 60Hz 1.6 ( .7 )sleeve & eye screw32 - 1.5 mm Dia.A L U M I N U MGRADE 5 ALUMINUM FLAT JAW Grounding Clamp - Acme Thread4345 “T” w/ strain 2.1 ( .9 )sleeve & “T” screw24442 “T” w/ strain 1.5” - .06” 2.1 ( .9 )sleeve & “T” screw 5 / B Flat or Square 400 RMS Amps4369 Eye w/ strain 2.0 ( .9 )sleeve & eye screw Serrated Jaw 1.26” - .06” 60Hz24441 Eye w/ strain 32 - 1.5 mm Dia. 2.0 ( .9 )sleeve & eye screwB R O N Z EA L U M I N U MGRADE 5 “T” / EYE “C” CLAMP - Acme Thread4242 “T” w/ strain 1.9 ( .9 )sleeve & “T”795 MCMeye screw26” x 7”ACSR5 / A to #6 400 RMS Amps9993 “T” w/ strain Smooth Jaw 60 Hz 1.6 ( .7 )sleeve & “T” 1.12” - .16”eye screw29 - 4mm Dia.H-10SALISBURY Grounding Equipment. www.wh<strong>salisbury</strong>.com


GROUNDING CLAMPS FOR FLATS & ANGLESThe Heavy Duty Bronze “C” Type FlatJaw Clamp with anti-blow off keeper ismade to fit structural angles, flats, and copperor copperweld stranded grounding jumpers.To install, first use an abrasive cloth or wirebrush to clean the surface to be clamped.Then, wipe the surface clean, position theclamp, finger tighten and set the screws. Usea wrench to secure and tighten. A 2667 clampwith contact stud offers greater versatility.2567Cat. No. & Description ASTM Main Line Tap Weight ea.Grade / Class Range Size lbs. ( kgs )2567 w/ Strain Angles & Flats: 5/8-11UNC 4 ( 1.8 )Relief Sleeve 5 / B 2.5”-4” WX Max. Cable5/8”-11NC Connection Serrated Jaw ( 64-101 x 3-19mm ) Size 4/0 Type VRounds:.25”-.75”( 6-19mm ) D.Compression Ferrules2577 w/ Strain Angles & Flats: 3/4-10UNC 4 ( 1.8 )Relief Sleeve 6 / B 2.5”-4” WX Max. Cable3/4”-10NC Connection Serrated Jaw ( 64-101x3-19mm ) Size 250 MCMRounds:Type V.25”-.75” Compression Ferrules( 6-19mm ) D.2667 2567 Clamp 5 / B 5 ( 2.3 )w/ Contact Stud Serrated JawS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401H-17


SPECIALTY CLAMPSCutout Clamps are applied with a clampstick into the bottomhinge contact of a cutout. This clamp can be used as part of aground jumper or by using a contact stud using a standardgrounding jumper with “C” clamps from the stud to ground.Lightweight, heavy duty Stringing Ground installs anywherealong the length of conductor to provide a continuousgrounding bond, even if the conductor is slack. Constructedof high-strength aluminum alloy with largediameter sheaves and bronze bushing bearings. Sideopening for quick, easy installation. Adjustable compressionspring assures proper contact for differentsizes of conductor and for easy passage of splices. Intests, this clamp withstood a 25kA, 28 cycle short circuit.The three options for a ground tap connection are: terminationfor ground cables, contact/hanger stud and connectorfor ground wire.21554310Cutout Clamp withContact StudThe Cable Penetrating Ground Clamp is designed to be usedeither as a tool for “spiking” jacketed cable or as a part of agrounding jumper used to bond both ends of an opened cable. The7/8” long plated steel point is inserted into the eye screw making alow resistant one piece spear. If one point becomes blunted it maybe sharpened or replaced with a new spear. Clamps are aluminumbody with either smooth or serrated upper jaws. The hardaluminum serrated insert makes optimum contact with thestranded neutral shield.2607Cutout ClampJumper AssemblyB R O N Z ECat. No. & Description ASTM Main Line Continuous Weight ea.Grade Range Current Rating lbs. ( kgs)BRONZE CUTOUT CLAMPS - “V” Thread4310 Eye 5/8 - 11 UNC 2.1 ( 1.1 )w/ ferrule connection Max. Cable Size: 4704373 Eye 400 RMS Amps 3.3 ( 1.5 )w/ contact stud 5 Type VI4379 Contact stud only Threaded Stud 60 Hz 1.2 ( .5 )Compression FerruleA L U M I N U MSTRINGING GROUND2155 Stringing ground Alloy Rollers 1033.5 KCM ACSR- 300 RMS Amps 5.3 ( 2.4 )Smooth Contacts to #2 Sol 60 HZClass A 1.26”-.25”32mm - 7mm DiaSplice: 1.5” ( 38mm ) diaCABLE PENETRATING GROUND CLAMP - Acme Thread - Pointed Lower Jaw2607 1.25” Opening Class B - - 1.7 ( .8 )20867 2.40” Opening serrated jaw 2.2 ( 1 )2618 1.50” Opening Class A - - 1.6 ( .7 )4290 2.40” Opening smooth jaw 2.1 ( 1 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401H-11


PRESSURE TERMINAL TYPE CLAMPSThese Duckbill and “C” Type Clamps featurepressure terminations for use with plain type ferrules.Made of high strength aluminum, with bronzeeye-screws, these Grade 5 clamps are designed forsmooth operation and long service life. Duckbillclamps for all grounding applications from .16 to1.1" diameter. “C” Type clamps for all groundingapplications from .06 to 1.25" diameter.24404NEWFlat Jaw Grounding Clamps are now availablewith pressure terminals for use with plain type cableferrules. These clamps are made of a high strengthaluminum, and a bronze eye screw or “T” handle fordurability and smooth operation. Also featured is ahardened aluminum alloy serrated insert. This insertis designed to grip tightly to flat surfaces and cutthrough surface contamination and oxidation for lowresistance contact. The pressure termination isdesigned on an angle keeping the cable out of theway during installation. The cable termination isangled to minimize interface with the “T” handle oreye when installing or removing the clamp.244662440524407 - Stick MountedDuck Bill ClampSalisbury’s 24438 Plain Ferrule 4-way Connectoris available on page H-23.24406Cat. No. & Description ASTM Main Line Continuous Weight ea.Grade / Class Range Current Rating lbs. ( kgs )A L U M I N U M1.1” SMOOTH JAW ALUMINUM --Spring Loaded - “V” Thread24404 Duckbill 795 KCM ACSR 1.5 ( .68 )Eye w/o strain relief sleeve 5 / A to #6 400 RMS AmpsSmooth Jaw 1.1” - .16” 60 Hz28mm - 4mm Dia. 4.5 / 224466 “C” Type 1035.5 KCM ACSR 2.2 ( 1.0 )Eye w/o strain relief sleeve 5 / A to #6 400 RMS AmpsSmooth Jaw 1.26” - .06” 60 Hz32mm - 4mm Dia. 4.5 / 224407 Stick mounted duckbill clamp 4.5 ( 2.05 )21754 Hanger Stud only .3 ( .1 )GRADE 5 ALUMINUM FLAT JAW Grounding Clamp - Acme Thread24405 “T” screw 1.5” - .06” 2.1 ( .9 )no strain relief sleeve 5 / B Flat or Square 400 RMS Amps24406 Eye screw Serrated Jaw 1.26” - .06” 60Hz 2.0 ( .9 )no strain relief sleeve32 - 1.5 mm Dia.H-12SALISBURY Grounding Equipment. www.wh<strong>salisbury</strong>.com


PLAIN SHROUDED & UNSHROUDED FERRULESPlain Ferrules are designed for use with all groundingclamps that feature pressure type terminal includingthe 1” duckbill and 1.5” flat jaw clamp.Copper Ferrules are available in two different styles:unshrouded and shrouded. Shrouded ferrules arecompressed on both the conductor and the jacket ofthe cable to reduce bending stress. Unshroudedferrules are crimped on the conductor strands only.These ferrules are manufactured of tin plated, 99.5%pure copper.plain shroudedAluminum Ferrules are available in two differentstyles: unshrouded and shrouded. Shrouded ferrulesare compressed on both the conductor and the jacketof the cable to reduce bending stress. Unshroudedferrules are crimped on the conductor strands only.plain unshroudedCat. No. Cable Size Strand Die Codes Jacket Die Codes Weight ea.Pair T&B T&B lbs. ( kgs )A L U M I N U M C O P P E RSHROUDED24424 #2 50 71 0.3 ( .14 )24425 1/0 50 71 0.35 ( .16 )24426 2/0 60 76 0.4 ( .18 )24427 4/0 66 106 0.45 ( .20 )UNSHROUDED24420 #2 50 - 0.3 ( .14 )24421 1/0 50 - 0.3 ( .14 )24422 2/0 60 - 0.35 ( .16 )24423 4/0 66 - 0.35 ( .16 )SHROUDED24434 #2 50 71 0.1 ( .045 )24435 1/0 50 71 0.1 ( .045 )24436 2/0 60 76 0.15 ( .07 )24437 4/0 71 106 0.15 ( .07 )UNSHROUDED24430 #2 50 - 0.12 ( .54 )24431 1/0 50 - 0.12 ( .54 )24432 2/0 60 - 0.16 ( .073 )24433 4/0 71 - 0.16 ( .073 )Add suffix “A” when requesting ferrules installed (crimped) to cables.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401H-13


BALL & SOCKET SYSTEMSocket ClampThe Ball and Socket GroundingSystem allows for variableangle accessibility. This system iscompact and lightweight. Thereare fixed grounding points on thesocket clamp. The 21190 SocketClamp, made from bronze alloy,has a socket size of 1” (25.4mm)and a threaded bore boss of 5/8”-11 UNC. The socket clamphas an integral cable support withstrain relief sleeve.21190Cat. No. & Description ASTM Continuous Current Weight ea.Grade Rating lbs. ( kgs)21190 w/ Strain 5 400 1.2 ( .54 )Relief Sleeve21277 w/o Strain 5 400 1.1 ( .5 )Relief SleeveH-14SALISBURY Grounding Equipment. www.wh<strong>salisbury</strong>.com


BALL & SOCKET SYSTEMBall StudsThe Ball Stud, long and short, the OffsetNema Pad Ball Stud, and the 21846 90° OffsetNema Pad are made from a copper alloy, tinplated.They each have a 1” (25.4mm) diameterball. The long and short Ball Stud have a 1/2”-13 UNC x 2” thread and a recommendedinstallation torque of 300 in. lbs. The short studis used conventionally. The long stud can also beused as the grounding point for “C” or Duckbillclamps that have a jaw width of 2.75” or less.The Offset Nema Pad Ball Stud has the standardNema bolt hole spacing and also comes in bothlong and short lengths. The Internal ThreadBall Stud is tapped for a 1/2-13 UNC bolthaving a length of at least 1”.2119221191240872122824082The Ball Stud Cover, made from orangeSALCOR®, allows for multiple angle applicationwhen installed using a clampstick.21846NEW21236Cat. No. Description Dimensions ASTM Grade Weight ea.in. ( mm ) lbs. ( kgs )21191 Ball Stud Short 4.38 ( 111 ) 5 .53 ( .23 )21192 Ball Stud Long 6.13 ( 156 ) 5 .81 ( .37 )21846 90° Offset Nema Pad 3.25 ( 83 ) x 5.75 ( 147 ) 5 1 ( .45 )24082 Internal Thread Ball Stud 4 ( 102 ) 5 .54 ( .25 )21228 Offset NEMA Pad Short 5.13 x 1.5 ( 130 x 38 ) 5 .84 ( .38 )24087 Offset NEMA Pad Long 7 x 1.5 ( 178 x 38 ) 5 1 ( .45 )21236 Cover for Ball Stud n / a .09 ( .04 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401H-15


GROUNDING CLAMP HANGER STUDSHanger Studs are designed to be used with all“C” and Duck Bill ground clamps. The HangerStud is used to hold one clamp of a set whilethe other is being installed on the de-energizedline. Hanger Studs are not designed or tested tocarry current.21754 Grounding Clamp Hanger Stud canonly be placed on clamps designed with ascrew down strain relief system.1928242725379983NEW21754*Cat. No. Stud For Use With Weight ea.lbs. ( kgs )1858 Hanger Aluminum Duck Bill 1”, 1.25”, 1.66” .5 ( .2 )1928 Hanger Aluminum “C” Clamps 1.25”, 1.5”, 2.4”, 3.5” .5 ( .2 )2427 Double Hanger Aluminum “C” Clamps 1.25”, 1.5”, 2.4”, 3.5” .5 ( .2 )2537 Hanger Aluminum “C” Clamps 1” .5 ( .22093 Hanger 556 Bronze Duck Bill, 477 Brz. “C”Clamp .5 ( .2 )9983 Hanger Brass 1”, 1.25”, 2.4” “C”Clamps .5 ( .2 )21754* Hanger Bronze 1”, 1.25”, 2.4” “C”Clamps .5 ( .2 )*For use with onlyPlain Ferrule TypeClamps and ThreadedFerrule Clamps with ascrew down strainrelief restraint system.H-16SALISBURY Grounding Equipment. www.wh<strong>salisbury</strong>.com


GROUNDING SETSSingle Grounding Jumpers &Single Jumper Ground SetsSingle Grounding Jumpers requirethe least amount of equipment. Sets ofsingle jumpers represent simplicity andversatility for personal protectivegrounding applications.Suggestions for consideration include:2653 Drawstring Bag for transportingand protection, 9998 pole mount barwith chain binder, 2103 screw groundrod and 60 ft. jumper for phase toground rod connection.24309For ordering convenience, completedSingle Grounding Jumpers are listedwhich cover many standard applicationneeds. Modification to these sets tomeet specific needs can be made.Contact your local Salisbury representativefor assistance.Typical Ground Cluster SetCat. No. Description ASTM Weight ea.Grade lbs. ( kgs )SINGLE GROUNDING JUMPERS24309 2 ea. #1895A Serrated Aluminum “C” Clamp 1.5” 2 5.9 ( 2.7 )1 pr. #2024A Ferrules6 ft. #2138 2/0 Cu. Cable yellowH-18SALISBURY Grounding Equipment. www.wh<strong>salisbury</strong>.com


GROUNDING SETSSingle Grounding Jumpers &Single Jumper Ground SetsCat. No. Description ASTM Weight ea.Grade lbs. ( kgs )SINGLE GROUNDING JUMPERS2299 2 ea. #1895A Serrated Aluminum “C” Clamp 1.5” 2 5.9 ( 2.7 )1 ea. #1928A Hanger Stud, 1 pr. #2027A Ferrules6 ft. #2137 1/0 Cu. Cable2319 2 ea. #1923A Smooth Aluminum “C” Clamp 2.4” 3 8.7 ( 3.9 )1 ea. #1928A Hanger Stud, 1 pr. #2620A Ferrules10 ft. #2138 2/0 Cu. Cable2320 1 ea. #1923A Smooth Aluminum “C” Clamp 3 7.4 ( 3.4 )1 ea. #4345 Aluminum Flat Jaw “T” Handle Clamp1 pr. #2620A Ferrules, 15 ft. #2138 2/0 Cu. Cable2321 2 ea. #1793A Bronze Duck Bill 556 KCM 2 5.4 ( 2.5 )1 ea. #2093A Hanger Stud, 1 pr. #2023A Ferrules6 ft. #2137 1/0 Cu. Cable2329 2 ea. #1921A Serrated Aluminum “C” Clamp 2.4” 3 9 ( 4.1 )1 ea. #1928A Hanger Stud, 1 pr. #2620A Ferrules10 ft. #2138 2/0 Cu. Cable2509 2 ea. #2514A Serrated Aluminum “C” Clamp 1.25” 2 6.1 ( 2.8 )1 ea. #1928A Hanger Stud, 1 pr. #2027A Ferrules6 ft. #2137 1/0 Cu. Cable2556 2 ea. #1852A Smooth Aluminum Duck Bill Clamp 1.66” 2 5.2 ( 2.4 )1 ea. #1858A Hanger Stud, 1 pr. #2027A Ferrules6 ft. #2137 1/0 Cu. Cable2558 2 ea. #1853A Serrated Aluminum Duck Bill Clamp 1.25” 2 5.5 ( 2.5 )1 ea. #1858A Hanger Stud, 1 pr. #2027A Ferrules6 ft. #2137 1/0 Cu. Cable2876 2 ea. #2531A Smooth Aluminum “C” Clamp 1.0” 2 4.9 ( 2.2 )1 ea. #2537A Hanger Stud, 1 pr. #2027A Ferrules6 ft. #2137 1/0 Cu. Cable9975 2 ea. #9985A Smooth Bronze “C” Clamp 1.0” 2 6.9 ( 3.1 )1 ea. #9983A Hanger Stud, 1 pr. #2023A Ferrules6 ft. #2137 1/0 Cu. Cable9982 2 ea. #9984A Smooth Bronze “C” Clamp 1.25” 2 8.3 ( 3.7 )1 ea. #9983A Hanger Stud, 1 pr. #2023A Ferrules6 ft. #2137 1/0 Cu. CableSINGLE JUMPER GROUND SETS2881 6 ea. #2531A Smooth Aluminum “C” Clamps 795 KCM 2 22.4 ( 10.2 )3 ea. #2537A Hanger Studs, 3 pr. #2027A Ferrules26 ft. #2137 1/0 Cu. Cable2882 6 ea. #1895A Serrated Aluminum “C” Clamps 1.5” 2 22.8 ( 10.2 )3 ea. #1928A Hanger Studs, 3 pr. #2027A Ferrules26 ft. #2137 1/0 Cu. CableS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401H-19


GROUNDING SETSSingle Point Distribution Grounding SetThis Single Point DistributionGrounding Set creates an equalpotential zone on the workingstructure. This is accomplished bybonding all conductors and thestructure to a ground source usingindividual jumpers as shown in theadjacent drawing.Going from either the ground rod orthe system ground to the polemounted contact bar under theworker’s feet, to the jumpersbonding the conductors creates anequal potential zone allowing thelineman to work safely.4246Cat. No. Description ASTM Weight ea.Grade lbs. ( kgs )4246 Complete Distribution Grounding Set 1 45.5 ( 20.6 )10 ea. #2531A Smooth Aluminum “C” Clamps 795 KCM1 ea. #9998 Aluminum Pole Mount Contact Bar5 pr. #2026A Ferrules3 ea. #2537A Hanger studs60 ft. #2636 # Cu. Cable1 ea. #2103 Screw Ground Rod w/ ConnectorAdditional Single Point Sets are available. Contact your local Salisbury representative.H-20SALISBURY Grounding Equipment. www.wh<strong>salisbury</strong>.com


GROUNDING SETS3 Wire Universal Grounding Clusters & SetsGrounding Clusters are usedto make it easy for a single lineworker to apply multiplegrounding jumpers on a threephase system. All clusters havean option of a ground lead byusing the extra connection pointon each cluster. Three wireclusters are recommended forthree phase Delta systems.Complete grounding clusterassemblies are available from thefactory. Specify cable size andlength required and assembly willbe made to your specifications.253417901957 25472685Cat. No. Description ASTM Weight ea.Grade lbs. ( kgs )2534 Cluster w/ 3 #2531 Smooth Jaw 5 4.9 ( 2.2 )1” Aluminum “C” Clamps1957 Cluster w/ 3 #1895 Serrated Jaw 5 6.4 ( 2.9 )1.5” Aluminum “C” Clamps1790 Cluster w/ 3 #1793 Smooth Jaw 4 6 ( 2.7 )556 KCM Bronze Duck Bill Clamps2547 Cluster w/ 3 #1852 Smooth Jaw 5 5.4 ( 2.5 )1.66” Aluminum Duck Bill Clamps2685 Assembled Ground Cluster Set 2 54.2 ( 24.6 )1 ea. #2516A Serrated Aluminum “C” Clamp 1.25” Cluster74 ft. #2637 1/0 Cu. Cable3 pr. #2027A Ferrules, 1 ea. #2103 Screw Ground Rod1 ea. #2654 Storage Bag4248 Assembled Ground Cluster Set 1 54.2 ( 24.6 )1 ea. #1790 Smooth Bronze Duck Bill Cluster76 ft. #2636 #2 Cu. Cable3 pr. #2022A Ferrules, 1 ea. #2103 Screw Ground Rod1 ea. #2654 Storage BagClusters are also available with Mounted Clamps, consult the factory for more information.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401H-21


GROUNDING SETS4 Wire Universal Grounding Clusters & SetsGrounding Clusters are used tomake it easy to apply multiplegrounding jumpers easy for asingle line worker. All clustershave an option of a ground leadby using the extra connectionpoint on each cluster. Four wireclusters are recommended forthree phase Wye systems.Complete grounding clusterassemblies are available from thefactory. Specify cable size andlength required and assembly willbe made to your specifications.2536 179421924247AssembledGround SetoptionalCat. No. Description ASTM Weight ea.Grade lbs. ( kgs )2536 Cluster w/ 6 #2531 Smooth Jaw 5 8.8 ( 4 )1” Aluminum “C” Clamps2192 Cluster w/ 6 #1895 Serrated Jaw 5 11.8 ( 5.4 )1.5” Aluminum “C” Clamps1794 Cluster w/ 6 #1793 Smooth Jaw 4 9 ( 4.1 )556 KCM Bronze Duck Bill Clamps2604 Cluster w/ 6 #1852 Smooth Jaw 5 6.2 ( 2.8 )1.66” Aluminum Duck Bill Clamps2682 Assembled Ground Cluster 1 14.5 ( 6.6 )1 ea. #1794A Smooth Bronze Duck Bill Cluster18 ft. #2636 #2 Cu. Cable3 pr. #2022A Ferrules1 ea. #2654 Storage Bag4247 Assembled Ground Cluster 2 18 ( 8.2 )1 ea. #2536 Smooth Aluminum “C” Cluster18 ft. #2637 1/0 Cu. Cable3 pr. #2027A Ferrules1 ea. #2654 Storage BagClusters are also available with Mounted Clamps, consult the factory for more information.H-22SALISBURY Grounding Equipment. www.wh<strong>salisbury</strong>.com


GROUNDING SETS4 Way Connector8’ cable10’ cable 10’ cable6’ cable2680NEW24438NEW217022374Cat. No. Description ASTM Weight ea.Grade lbs. ( kgs )2680 Four Way Connector Ground Set 5 28 ( 12.7 )21 kA 15 cycles1 #2374A Four Way Connector w/ Sleeves4 #1895A 1.5” Smooth Jaw Clamps w/ Sleeves1 #2427A Double Hanger Stud, 1 #2402A Contact Stud34 ft. #2137 1/0 Cu. Cable4 pr. #2027 Ferrules2374 Threaded Ferrule Four Way Connector 5 1.8 ( .8 )21702 Threaded Ferrule Four Way Connector 1 ¾ long x 2 ¼ dia. 5 .5 ( .23 )24438 Plain Ferrule Four Way Connector 5 2 ( .9 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401H-23


GROUNDING SETSFor Special ApplicationsListed are some typical completepersonal protectionground sets for common lineconstruction. These sets,although practical for manyapplications, are shown as aguide to help determine individualsystem needs and forease of ordering. Variations ofthese sets may be requested tomeet specific situations or userpreferences. Your localSalisbury representative cananswer any questions you haveon personal protection groundingneeds and applications.26844276Cat. No. Description ASTM Weight ea.Grade lbs. ( kgs )COMPLETE 3 PHASE DELTA4249 2 ea. #20880A Contact Bar 2 63.5 ( 28.8 )7 ea. #2531A Smooth Aluminum “C” Clamp 795 KCM86 ft. #2637 1/0 Cu. Cable, 4 pr. #2027A Ferrules2 ea. #2537A Hanger Studs, 1 ea. #2654 Storage Bag1 ea. #2103 Screw Ground Rod2684 2 ea. #20880A Contact Bar 2 63.5 ( 28.8 )7 ea. #1893A Serrated Aluminum “C” Clamp 1.5”84 ft. #2637 1/0 Cu. Black Cable, 4 pr. #2027A Ferrules2 ea. #1928A Hanger Studs, 1 ea. #2654 Storage Bag1 ea. #2103 Screw Ground RodCOMPLETE 4 WIRE WYE4276 1 ea. #20880A Contact Bar 2 34 ( 15.4 )7 ea. #2531A Smooth Aluminum “C” Clamp 795 KCM32 ft. #2637 1/0 Cu. Cable, 4 pr. #2027A Ferrules3 ea. #2537A Hanger Studs, 1 ea. #2654 Storage BagH-24SALISBURY Grounding Equipment. www.wh<strong>salisbury</strong>.com


GROUNDING SETSDead Front Grounding Jumpers & ElbowsDead Front Ground Sets are supplied withan insulated grounding elbow, yellowjacketed copper grounding cable, and a 1815bronze flat jaw ground clamp for the groundconnection. Grounding Elbows are equippedwith arc quenching tips as provided onstandard load break elbows.Both 15kV and 25kV elbows are availablewith connectors for 1/0 or 2/0 cable.Assembled sets for 15kV and 25kV areavailable for single phase or three phasegrounding requirements. Standard threephase sets have a 4 ft. tail connecting to a2374 four wire connector with 2 ft. leadsfor the elbows. Sets can be factory assembledto customer specifications.ElbowCat. No. Description Weight ea.lbs. ( kgs )INSULATED GROUNDING ELBOWS2910 15kV Elbow w/ 1/0 Cable Connector 1.7 ( .7 )2912 15kV Elbow w/ 2/0 Cable Connector 1.7 ( .7 )2935 25kV Elbow w/ 1/0 Cable Connector 2 ( .9 )2936 25kV Elbow w/ 2/0 Cable Connector 2 ( .9 )ASSEMBLED GROUNDING SETS2961 15kV Single Phase, 6 ft. 1/0 Cable w/ Bag 10 ( 4.5 )2962 15kV Single Phase, 6 ft. 1/0 Cable w/o Bag 8 ( 3.6 )2963 15kV Three Phase, 1/0 Cable w/ Bag 22 ( 10 )22630 15kV Three Phase, 1/0 Cable w/o Bag 20 ( 9 )2971 25kV Single Phase, 6 ft. 1/0 Cable w/ Bag 13 ( 5.9 )22631 25kV Single Phase, 6 ft. 1/0 Cable w/o Bag 11 ( 5 )2973 25kV Three Phase, 1/0 Cable w/ Bag 24 ( 10.9 )22632 25kV Three Phase, 1/0 Cable w/o Bag 22 ( 10 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401H-25


GROUNDING CABLESGrounding Cables are made with extra flexible strand ofsoft drawn #30 AWG (.01”) copper and are available inthree different jackets.The yellow thermoplastic elastomer jacketed cable is thestandard for grounding service. It provides a combinationof economy, flexibility, and durability. The service temperatureranges from 200º to -50ºF. ASTM F 855 Type I.The black thermoplastic elastomer jacketed cable has asmaller diameter and thinner jacket material giving it betterflexibility than the yellow cable. The service temperatureranges from 200º to -50ºF. ASTM F 855 Type I.The transparent flexible thermoplastic (PVC) jacketed cableallows easy inspection for strand breakage. The flexibilitydecreases with low temperatures. The minimum recommendedservice temperature is 0ºF. ASTM F 855 Type III.Cat No. Size Strand Dia. Jacket Short Circuit Withstand Continuous Wt. / 1000 ft.in. ( mm ) in. ( mm ) AMPS, RMS, 60Hz Current lbs. ( kgs )15 Cycles 30 Cycles AMPS, RMS, 60HzB L A C K Y E L L O WC L E A R2136 #2-665W .35 ( 8.9 ) .5 ( 12.7 ) 14500 10000 200 282 ( 127 )2137 1/0-1064W .45 ( 11.4 ) .62 ( 15.7 ) 21000 15000 250 488 ( 221 )2138 2/0-1330W .49 ( 12.4 ) .65 ( 16.5 ) 27000 20000 300 537 ( 243 )2139 4/0-2109W .62 ( 1.7 ) .83 ( 21.1 ) 43000 30000 400 836 ( 379 )2636 #2-665W .35 ( 8.9 ) .47 ( 12 ) 14500 10000 200 263 ( 119 )2637 1/0-1064W .45 ( 11.4 ) .58 ( 14.7 ) 21000 15000 250 404 ( 183 )2638 2/0-1330W .49 ( 12.4 ) .63 ( 16 ) 27000 20000 300 497 ( 225 )2649 3/0-1672W .55 ( 14 ) .72 ( 18.3 ) 36000 25000 350 680 ( 308 )2639 4/0-2109W .62 ( 1.7 ) .78 ( 19.8 ) 43000 30000 400 770 ( 349 )2128 #2-665W .35 ( 8.9 ) .53 ( 13.5 ) 14500 10000 200 289 ( 131 )2129 1/0-1064W .45 ( 11.4 ) .64 ( 16.3 ) 21000 15000 250 520 ( 235 )2133 2/0-1330W .49 ( 12.4 ) .7 ( 17.8 ) 27000 20000 300 546 ( 247 )2288 4/0-2109W .62 ( 1.7 ) .84 ( 21.3 ) 43000 30000 400 841 ( 381 )H-26SALISBURY Grounding Equipment. www.wh<strong>salisbury</strong>.com


GROUNDING FERRULESFor lasting low resistance, compressionGrounding Ferrules connect cablestrands with a threaded stud thatscrews into a tapped boss on a clamp.Nut and lock washers increase contactpressure and secure the assembly. Usethe aluminum ferrules on aluminumbody clamps. The tin plated copperferrules can be used on either bronze oraluminum body clamps. All Salisburygrounding ferrules are unshrouded andmanufactured with a 5/8-11 UNCthreaded stud.Cat. No. ASTM Size Installing Die Codes Weight ea.Pair Grade T&B lbs. ( kgs )A L U M I N U M2026 1 #2 50 .2 ( .1 )2027 2 1/0 50 .2 ( .1 )2620 3 2/0 60 .3 ( .1 )4284 4 3/0 71 .3 ( .1 )2640 5 4/0 71 .3 ( .1 )C O P P E R2022 1 #2 50 .5 ( .2 )2023 2 1/0 50 .4 ( .2 )2024 3 2/0 60 .4 ( .2 )4277 4 3/0 66 .6 ( .3 )2025 5 4/0 66 .6 ( .3 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401H-27


CONDUCTOR & CLEANING TOOLSTubular Brushes are preferred whenrubber gloving or working on de-energizedconductors. The damage to rubber glovesis minimal because the steel bristles areinternal. The 2.5” tubular brush is used inconfined areas such as between twoconnectors or clamps.41104337The “V” Type Wire Brush has an epoxycoated handle. Replacement brushes areavailable.410841124113 4111Cat. No. Description Weight ea.in. ( mm ) lbs. ( kgs )4110 5” ( 127 ) Tubular 0.4 ( 0.2 )4337 2.5” ( 63.5 ) Tubular 0.2 ( 0.1 )4108 Universal Tubular 1.3 ( 0.6 )4112 “V” Type handle w/ brushes 1.2 ( 0.6 )4113 “V” Type carton of 10 replacement brushes 3 ( 1.4 )4111 Universal “V” Line Cleaner 1 ( 0.5 )H-28SALISBURY Grounding Equipment. www.wh<strong>salisbury</strong>.com


GROUNDING ACCESSORIESPole Mounted Contact Bars are designed toact as a convenient common point forelectrical connections and also as a hangerfor jumper sets during installation andremoval. Supplied with a chain and anadjustable wheel binder that will accommodatemost common pole diameters. Catalog#20880 has one 5/8-11UNC tapped hole for thepermanent connection of a ground lead.Strain Relief Sleeves reinforce cables at the terminationpoints when used with the cable support system.This decreases strand damage to cables from age ormishandling which reduces current carrying capacityand service life. SALCOR® Strain Relief Sleeves arestandard and accept all grounding cables #2 through 4/0. Sleeve assembly consists of two parts: the innersleeve which is discarded if the cable diameter exceeds.72” and tapered outer sleeve, 6.5” long, which can becut to match the diameters. Clear strain relief sleeves,for use with clear cables or for inspection purposes,are also available to fit ground clamps. Clear heatshrink is also available.9998NEW21840The Salisbury 2103 Screw Type Temporary GroundRod is used when an adequate system ground is notavailable. The design incorporates a copperweld rodwith bronze fittings screwed and pinned on both ends.The terminal on the handle is designed to accept cablesequipped with a 5/8-11 UNC threaded ferrule. As analternative, a “C” clamp may also be attached directlyto the ground rod shaft.17882103Cat. No. Grade Description Weight ea.lbs. ( kgs )POLE MOUNTED CONTACT BARS9998 5 Contact Bar No Connection 4’ Chain w/ Adjustable Wheel Binder 9.1 ( 4.1 )21840 5 Contact Bar No Connection 40” Chain w/ Adjustable Wheel Binder 7 ( 3.3 )20880 5 Contact Bar One Connection 4’ Chain w/ Adjustable Wheel Binder 9.1 ( 4.1 )CABLE STRAIN RELIEF SLEEVES1788 Complete SALCOR Strain Relief Assembly .1 ( .04 )1758 Inner SALCOR Sleeve Only .1 ( .04 )0786 Tapered Outer SALCOR Sleeve Only .1 ( .04 )2983 Clear Sleeve for #2 to 2/0 Grounding Cable .1 ( .04 )2633 Clear Sleeve for 4/0 Grounding Cable .1 ( .04 )20886 Clear Heat Shrink, 5”( 127mm ) for All Grounding Cables .1 ( .04 )SCREW GROUND ROD2103 75” ( 1.9m ) long 8 ( 3.6 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401H-29


VOLTAGE DETECTORSAudio / VisualVoltage Detectors are used to verify liveor de-energized conductors. These testersmay be used with rubber insulating gloves orhot sticks using the splined universal endfitting. Testers indicate voltage with an extrabright LED light and a distinctive audible signal.It is recommended that the tester be movedcloser to conductor until warning is indicated, orit touches conductor, apparatus, or test point.Test the unit on a nearby energized conductor. Eachtester includes three “C” batteries.The 4445 Voltage Detector Tester provides themost convenient and reliable means of verifyingoperation of Salisbury Voltage Detectors. The testerfeatures instant push-button operation and requires astandard 9-volt battery (included). It’s portable andlightweight. To operate, push the button and movethe tester toward the voltage detector being verified.The tester generates an electric field that activates thedetector verifying the audible and visual signals areoperational.4445Test ProceduresTest ProceduresTo assure unit is in operable condition switch tester into “Test-240V” position. The tester may now be tested in severaldifferent ways.1. Place head as marked against live wire outlet or equivalentabove 110V A.C.2. Rub the head as marked on cloth or clothing to obtainstatic charge. Unit will only indicate intermittently.WARNINGDo not assume conductors are deador will remain de-energized. Alwaysinstall proper grounding devicesbefore working conductors.Cat. No. Dimensions Settings Weight ea.in. ( mm ) phase to phase lbs. ( kgs )4444 11 x 3.5 ( 279.4 x 89 ) Off / Test-240V / Battery / URD:15kV/25kV/35kV 15oz. ( .43 )Overhead: 4.2kV / 15kV/25kV/35kV/46kV/69kV4244 11 x 3.5 ( 279.4 x 89 ) Off / 240V / 4.2kV / 15kV/25kV/35kV/69kV/115kV/230kV 15oz. ( .43 )4344 11 x 3.5 ( 279.4 x 89 ) Off / 240V / 4.2kV /35kV/69kV/115kV/230kV/345kV/500kV 15oz. ( .43 )COMPLETE KIT4356 1-4244 Tester 240V to 230kV, 1-4315 Case, 1-2500 Shotgun Adapter 2 ( .91 )4367 1-4344 Tester 240V to 500kV, 1-4315 Case, 1-2500 Shotgun Adapter 2 ( .91 )4469 1-4444 Tester 240V to 69kV, 1-4315 Case, 1-2500 Shotgun Adapter 2 ( .91 )4445 Voltage Detector Tester 1 ( .45 )4315 12 x 8 x 4.5 ( 5.45 x 3.6 x 2 ) Storage Case 1 ( .45 )2500 Shotgun Adapter .4 ( .2 )H-30SALISBURY Grounding Equipment. www.wh<strong>salisbury</strong>.com


VOLTAGE DETECTORSNEW Self Testing Audio / VisualSalisbury’s NEW Self-TestingVoltage Detectors allowtesting to be continuous andautomatic. An intermittent flashand beep confirms the detectoris functioning properly.Self-Testing Voltage Detectors areused to verify live or de-energized conductors.These testers may be used withrubber insulating gloves or hot sticksusing the splined universal end fitting.Testers indicate voltage with an extrabright LED light and a distinctive audiblesignal. It is recommended that the testerbe moved closer to the conductor until awarning is indicated, or it touches theconductor, apparatus, or test point. Eachtester includes three “C” batteries.NEWWARNINGDo not assume conductors are dead or willremain de-energized. Always install propergrounding devices before working conductors.Cat. No. Dimensions Settings Weight ea.in. ( mm ) phase to phase lbs. ( kgs )4544 11 x 3.5 ( 279.4 x 89 ) Off / 240V / 4.2kV / 15kV/25kV/35kV/69kV/115kV/230kV 15oz. ( .43 )4644 11 x 3.5 ( 279.4 x 89 ) Off / 240V / 4.2kV /35kV/69kV/115kV/230kV/345kV/500kV 15oz. ( .43 )4744 11 x 3.5 ( 279.4 x 89 ) Off / Test-240V / Battery / URD:15kV/25kV/35kV 15oz. ( .43 )Overhead: 4.2kV / 15kV/25kV/35kV/46kV/69kVCOMPLETE KIT4556 1-4544 Tester 240V to 230kV, 1-4315 Case, 1-2500 Shotgun Adapter 2 ( .91 )4667 1-4644 Tester 240V to 500kV, 1-4315 Case, 1-2500 Shotgun Adapter 2 ( .91 )4769 1-4744 Tester 240V to 69kV, 1-4315 Case, 1-2500 Shotgun Adapter 2 ( .91 )4315 12 x 8 x 4.5 ( 5.45 x 3.6 x 2 ) Storage Case 1 ( .45 )2500 Shotgun Adapter .4 ( .2 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401H-31


HYDRAULIC CABLE SPIKEHydraulic Cable Spikes are designed toverify that an underground power line-upto 1000 mcm-is de-energized beforecutting, repairing, splicing or replacing.The cable spike, a solid brass body with astainless steel piercing tip, is fitted tohydraulic compression tools so that thecable can be accurately spiked from a safedistance. An anodized aluminum insert isincluded to position the cable precisely.24320Improves Control,Accuracy and SafetySaves TimeRemote ControlledWARNING: ELECTRICSHOCK HAZARDThis tool is not insulated. Use onlycertified, non-conductive hoses andproper personal protective equipmentwhen using this unit. Failure to do socould result in severe injury or death.Adapter fits the following tools:Huskie EP610HBurndy Y46Brock 13-H.Cat. No. Cable Length Description Weight ea.ft ( m ) lbs. ( kgs )24320 6 ( 1.8 ) Spiking Tool & Grounding Assembly: 9.5 ( 4.3 )Cable Spiking Tool & Insert24321 8 ( 2.4 ) 4388A C Clamp 11.2 ( 5.1 )2139 4/0 Cu Cable24322 10 ( 3 ) 2025A 4/0 Cu Ferrules (Pair) 12.9 ( 5.86 )616 BagUS Patent # 544 7450RPT1 Replacement Piercing Tip 1 oz ( 28 g )H-32SALISBURY Grounding Equipment. www.wh<strong>salisbury</strong>.com


STATIC DISCHARGE STICKThe Static Discharge Stick is designed to safelyremove the static charge after de-energizing. Thisgrounding tool is pre-assembled and includes abrass alloy “U” hook, 4’ closed sell foam filledtubular fiberglass switch stick or as a 1’ universalattachment made in accordance with ASTMStandard F711, 6’ of copper grounding cableattached to a Salisbury 1814 bronze flat jawserrated grade 3 clamp.NEWStatic Discharge StickStatic Discharge Stick w/ Universal AttachmentCat. No. Cable Length Description Weight ea.ft ( m ) lbs. ( kgs )20817 6 ( 1.8 ) Static Discharge Stick 4’ (1.2m) length 8 ( 3.6 )22629 6 ( 1.8 ) Static Discharge Stick w/ Universal Attachment .38 ( 0.17 )1’ (0.3m) lengthS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401H-33


ASTM TABLESASTM F855 Table 1 - Protective Grounding Clamp RatingsASTM F855 Table 2 - Grounding Cable Ferrule and Assembly RatingsH-34SALISBURY Grounding Equipment. www.wh<strong>salisbury</strong>.com


HOT STICKS & TOOLSFiberglass Hot SticksFRP ClampsticksUniversal Switch SticksUniversal Switch SticksFiberglass Hot Switch SticksRescue Hook, Static Discharge Stick and AccessoriesLineman’s Strap HoistUniversal FittingsUniversal FittingsStorage for Hot Sticks and ToolsFiberglass Hot Clampsticks Repair Parts ListSALISBURY Fiberglass Telescoping Hot SticksSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401I-1


FIBERGLASS HOT STICKSStandard SpecificationsThere are a variety of Fiberglass Reinforced Plastic(FRP) constructions used for hot sticks. Included arefoam filled tubular sticks used for all products requiringsolid construction. Other product applications requirehollow tubular sections. Both of these processes meetASTM F711 Standard Specifications for FRP and tubeused in live line tools.Foam filled hot sticks are manufactured using thepultrusion process. Hollow hot sticks are producedusing a winding or wrapping process. Both methodsincorporate fiberglass reinforcement in a resin matrixwhich creates a moisture resistant laminate withexcellent electrical and mechanical properties.Foam Filled Hot StickHot stick production is 100% electrically proof tested.Hot Stick blanks must pass a test of 100kV/12”(305mm) for 5 minutes without detectable heating priorto being accepted.Live Line WorkMinimum Approach DistanceNominal Exposure Distance ft.-in ( m )Voltage kV Phase to Ground Phase to Phase.05 to 1 avoid contact avoid contact1.1 to 15 2-1 ( .64 ) 2-2 ( .66 )15.1 to 36 2-4 ( .72 ) 2-7 ( .77 )36.1 to 46 2-7 ( .77 ) 2-10 ( .85 )46.1 to 72.5 3-0 ( .9 ) 3-6 ( 1.05 )72.6 to 121 3-2 ( .95 ) 4-3 ( 1.29 )138 to 145 3-7 ( 1.09 ) 4-11 ( 1.5 )161 to 169 4-0 ( 1.22 ) 5-8 ( 171 )230 to 242 5-3 ( 1.59 ) 7-6 ( 2.27 )345 to 362 8-6 ( 2.59 ) 12.6 ( 3.8 )500 to 550 11-3 ( 3.42 ) 18-1 ( 5.5 )765 to 800 14-11 ( 4.53 ) 26-0 ( 7.91 )- These distances take into consideration the highest switch surge anemployee will be exposed to on any system with air as the insulatingmedium and the maximum voltage shown.-The clear live-line total distances shall equal or exceed the values forthe indicated voltage ranges.Foam Filled FiberglassHot Stick BlanksCat. No. Dimensions Dia / length Wt. ea.in. x ft. mm x m lbs. ( kgs )9901 1.25 / 4 31.7 / 1.2 1.5 ( 0.7 )9902 1.25 / 6 31.7 / 1.8 2.3 ( 1 )9903 1.25 / 8 31.7 / 2.4 3 ( 1.4 )9904 1.25 / 10 31.7 / 3 3.8 ( 1.7 )9905 1.25 / 12 31.7 / 3.6 4.5 ( 2 )9906 1.25 / 14 31.7 / 4.3 5.3 ( 2.4 )9818 1.5 / 4 38.1 / 1.2 2 ( .91 )9819 1.5 / 6 38.1 / 1.8 3 ( 1.4 )9907 1.5 / 8 38.1 / 2.4 4 ( 1.8 )9908 1.5 / 10 38.1 / 3 5 ( 2.3 )9909 1.5 / 12 38.1 / 3.6 6 ( 2.7 )9910 1.5 / 14 38.1 / 4.3 7 ( 3.2 )9911 1.5 / 16 38.1 / 4.9 8 ( 3.6 )9912 1.5 / 18 38.1 / 5.5 9 ( 4.1 )9995 1.5 / 20 38.1 / 6 10 ( 4.5 )SALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401I-3


FRP CLAMPSTICKSTough Thermoplastic head ferrule.EZ Grip plastic hand grip.Wide opening 15/16” ( 23.8mm)stainless steel hook.Heavy rubber end cap.External Rod Clampsticks are constructedof closed cell foam-filled tubularfiberglass in accordance with ASTMstandard F711. The hook operating rod,made of solid 3/8” ( 9.5mm) dia. fiberglass,is mounted on the exterior of thetool so that it can be easily wiped downprior to use.Side OpeningHookCat. No. Length Weight ea.Feet Meters lbs. kgsEXTERNAL ROD CLAMPSTICK4007 4’ 8” 1.32 4.2 1.94008 5’ 8” 1.62 4.6 2.14009 6’ 8” 1.93 5.2 2.44010 8’ 8” 2.54 6.2 2.84011 10’ 8” 3.15 7.0 3.24012 12’ 8” 3.76 7.7 3.54013 14’ 8” 4.37 9.4 4.3Add suffix “S” for a 9864 Switch Stick Head or a “U” for a 9840Splined Universal Head. Clamp sticks may be ordered with thesefittings attached to the butt by adding the appropriate suffix tothe catalog number.9840 SplinedUniversal HeadI-4SALISBURY Hot Sticks and Tools. www.wh<strong>salisbury</strong>.com


UNIVERSAL SWITCH STICKSOne, two, and three section hotsticks have a standard splineduniversal head. 1.25” dia. switchsticks are supplied with a #9971Prong. A Heavy Duty DisconnectProng #9969 is supplied on all others.9969 Prong9971 ProngCat. No. Dimensions: Dia. x Length Weight ea.lbs. kgsONE SECTION in x ft. mm x m4213 1.25 x 4 31.7 x 1.2 2.6 1.24214 1.25 x 6 31.7 x 1.8 3.4 1.54215 1.25 x 8 31.7 x 2.4 4.1 1.94216 1.25 x 10 31.7 x 3 4.9 2.24217 1.25 x 12 31.7 x 3.6 5.6 2.54218 1.25 x 14 31.7 x 4.3 6.4 2.94219 1.5 x 8 38.1 x 2.4 5.4 2.54220 1.5 x 10 38.1 x 3 6.5 34221 1.5 x 12 38.1 x 3.6 7.5 3.44222 1.5 x 14 38.1 x 4.3 8.6 3.94223 1.5 x 16 38.1 x 4.9 9.8 4.34224 1.5 x 18 38.1 x 5.5 10.7 4.94225 1.5 x 20 38.1 x 6 11.7 5.3TWO SECTIONSOAL Length Top Bottom lbs. kgsft. m in. x ft. mm x m in. x ft. mm x m4036 8 2.4 1.25 x 4 31.7 x 1.2 1.25 x 4 31.7 x 1.2 4.2 1.94037 10 3 1.25 x 5 31.7 x 1.5 1.25 x 5 31.7 x 1.5 5.2 2.24038 12 3.6 1.25 x 6 31.7 x 1.8 1.5 x 6 38.1 x 1.8 6.9 3.14039 14 4.3 1.25 x 6 31.7 x 1.8 1.5 x 8 38.1 x 2.4 7.9 3.14040 16 4.9 1.25 x 8 31.7 x 2.4 1.5 x 8 38.1 x 2.4 8.6 3.94041 18 5.5 1.25 x 8 31.7 x 2.4 1.5 x 10 38.1 x 3 9.6 4.44042 20 6 1.25 x 10 31.7 x 3 1.5 x 10 38.1 x 3 10.4 4.7THREE SECTIONOAL Length Top Middle / Bottom lbs. kgsft. m in x ft. mm x m in. x ft. mm x m4043 12 3.6 1.25 x 4 31.7 x 1.2 1.5 x 4 38.1 x 1.2 7.7 3.54044 15 4.6 1.25 x 5 31.7 x 1.5 1.5 x 5 38.1 x 1.5 9.1 4.14045 18 5.5 1.25 x 6 31.7 x 1.8 1.5 x 6 38.1 x 1.8 10.5 4.74046 20 6 1.25 x 8 31.7 x 2.4 1.5 x 6 38.1 x 1.8 16.5 7.5HEAD ONLY9840 1.25 31.7 Universal Head 0.2 0.19841 1.5 38.1 Universal Head 0.3 0.1FRP Splices with ButtonSALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401I-5


UNIVERSAL SWITCH STICKSDouble Ended & Tie HeadsThese foam filled FRPHot Sticks are manufacturedusing a pultrusionprocess that results in aproduct with extremelyhigh electrical andmechanical qualities.4084 Rotary Prong 4086 Rotary Blade Head 4088 Double Prong HeadCat. No. Dimensions: Dia. x Length Weight ea.in. x ft. mm x m lbs. kgsDOUBLE ENDED UNIVERSAL4230 1.25 x 6 31.7 x 1.8 3.3 1.54231 1.25 x 8 31.7 x 2.4 4 1.84232 1.25 x 10 31.7 x 3 4.8 2.24233 1.25 x 12 31.7 x 3.6 5.5 2.54234 1.25 x 14 31.7 x 4.3 6.3 2.8UNIVERSAL w/ Rotary Prong or Blade4084 Rotary Prong 1.25 x 6 31.7 x 1.8 3.8 1.74085 Rotary Prong 1.25 x 8 31.7 x 2.4 4.5 24086 Rotary Blade 1.25 x 6 31.7 x 1.8 3.8 1.74087 Rotary Blade 1.25 x 8 31.7 x 2.4 4.5 2UNIVERSAL w/ Double Prong4088 1.25 x 6 31.7 x 1.8 3.8 1.74089 1.25 x 8 31.7 x 2.4 4.5 2HEAD ONLY4095 Rotary Blade Head 0.8 0.44096 Double Prong Head 0.8 0.44098 Blade Hanger 0.3 0.1I-6SALISBURY Hot Sticks and Tools. www.wh<strong>salisbury</strong>.com


FIBERGLASS HOT SWITCH STICKSSwitch Sticks use closed cell foam filled tubularfiberglass made in accordance with ASTMStandard F711. Both the standard head and theheavy duty prong disconnect are made of durablehigh strength aluminum bronze alloy.Standard ProngHeavy Duty ProngCat. No. Dimensions: Dia. x Length Weight ea.HD Std Prong in. x ft. mm x m lbs. kgsONE SECTION9950 9933 1.25 x 4 31.7 x 1.2 2.1 19951 9934 1.25 x 6 31.7 x 1.8 2.9 1.39952 9935 1.25 x 8 31.7 x 2.4 3.6 1.69953 9936 1.25 x 10 31.7 x 3 4.4 29954 9937 1.25 x 12 31.7 x 3.6 5.1 2.39955 9938 1.25 x 14 31.7 x 4.3 5.9 2.79956 9939 1.5 x 8 38.1 x 2.4 5 2.39957 9940 1.5 x 10 38.1 x 3 6 2.79958 9941 1.5 x 12 38.1 x 3.6 7 3.29959 9942 1.5 x 14 38.1 x 4.3 8.1 3.79960 9943 1.5 x 16 38.1 x 4.9 9.1 4.19961 9944 1.5 x 18 38.1 x 5.5 10.2 4.69962 9945 1.5 x 20 38.1 x 6 11.2 5.1TWO SECTION OAL Length Top Bottomft. m in. x ft. mm x m in. x ft. mm x m lbs. kgs4024 4014 8 2.4 1.25 x 4 31.7 x 1.2 1.25 x 4 31.7 x 1.2 3.8 1.74025 4015 10 3 1.25 x 5 31.7 x 1.5 1.25 x 5 31.7 x 1.5 4.6 2.14026 4016 12 3.6 1.25 x 6 31.7 x 1.8 1.25 x 6 31.7 x 1.8 5.3 2.44017 14 4.3 1.25 x 7 31.7 x 2.1 1.25 x 7 31.7 x 2.1 6.1 2.74027 14 4.3 1.25 x 6 31.7 x 1.8 1.5 x 8 38.1 x 2.4 7.8 3.54028 4018 16 4.9 1.25 x 8 31.7 x 2.4 1.5 x 8 38.1 x 2.4 8 3.64029 18 5.5 1.25 x 8 31.7 x 2.4 1.5 x 10 38.1 x 3 9.5 4.34030 20 6 1.25 x 10 31.7 x 3 1.5 x 10 38.1 x 3 10.3 4.6THREE SECTION OAL Length Top Middle / Bottomin. mm in. x ft. mm x m in. x ft. mm x m lbs. kgs4031 12 3.6 1.25 x 4 31.7 x 1.2 1.5 x 4 38.1 x 1.2 7.6 3.44032 15 4.6 1.25 x 5 31.7 x 1.5 1.5 x 5 38.1 x 1.5 9 4.14033 18 5.5 1.25 x 6 31.7 x 1.8 1.5 x 6 38.1 x 1.8 10.4 4.74034 20 2 1.25 x 8 31.7 x 2.4 1.5 x 6 38.1 x 1.8 11.1 5HEAD ONLY9862 9864 1.25 31.7 Universal Head 0.4 0.29861 9863 1.5 38.1 Universal Head 0.5 0.2SALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401I-7


RESCUE HOOK, STATIC DISCHARGE & ACCESSORIESFRP Sleeve Splices are fiberglass reinforced plasticwith spring loaded push buttons. They sectionize longsticks for easy storage. Factory assembly is recommended.For splice stick assemblies other than thoselisted in the catalog consult the factory for quotations.4182 CapSplice GuardSplice Guards reduce the damage to the butt of splicedsticks when working with only the top sections.FRP Splices with ButtonInsulated Rescue HookSalisbury Insulated Rescue Hook isan invaluable tool for any workplaceused to withdraw an injured workerout of a hazardous area. Confinedspaces, in vaults, or just near electricalcabinets and switch gear are some ofthe places where this tool is a must.Featuring a foam filled, fiberglassreinforced handle for superior electricalinsulation and a coated heat treatedbody hook with an 18” opening. Thestick is available in the standard lengthsof 6 and 8-foot lengths. Other lengthsare available as a special order.Contact us with your requirements.Static Discharge StickThe Static Discharge Stick is designed to safely remove the staticcharge after de-energizing. This grounding tool is pre-assembled andincludes a brass alloy “U” hook, 4’ closed sell foam filled tubularfiberglass switch stick or as a 1’ universal attachment made inaccordance with ASTM Standard F711. 6’ of copper grounding cable,6’ of copper grounding cable attached to a Salisbury 1814 bronze flatjaw serrated grade 3 clamp.NEWStatic Discharge Stickw/ Universal AttachmentCat. No. Dimensions Weight ea.in. mm lbs. kgsFRP SLEEVE SPLICES9898 1.25 to 1.25 31.7 to 31.7 0.4 0.29897 1.5 to 1.25 38.1 to 31.7 0.8 0.49899 1.5 to 1.5 38.1 to 38.1 0.9 0.4SPLICE GUARD4182 1.25 31.7 0.2 0.14183 1.5 31.8 0.2 0.1INSULATED RESCUE HOOK24401 Rescue Hook 6’ (1.8 m) length 4.5 ( 2 )24403 Rescue Hook 8’ (2.4 m) length 5.5 ( 2.5 )STATIC DISCHARGE STICK20817 Static Discharge Stick 4’ (1.2m) length 8 ( 3.6 )22629 Static Discharge Stick w/ Universal Attachment 1’ (0.3m) length .38 ( 0.17 )I-8SALISBURY Hot Sticks and Tools. www.wh<strong>salisbury</strong>.com


LINEMAN’S STRAP HOISTCast Aluminum andZinc Alloy MainBody PartsLineman’s Hoists are lightweight andeasy to handle. All the control levers areeasy to reach and operate by hand or witha hot stick. The castings are corrosionresistant aluminum alloy with forged steelalloy hoods and stainless steel springs andshafts.The fiberglass handles are built to ASTMhot stick standards. The 300DLMH and344DLMH can be operated by hot sticks,shotguns and/or lanyards. 300LMHrequires hand operation.When the web strap is clean and dry it hasdielectric properties, but it is not to beconsidered an insulating member. Allhooks swivel to ensure positive strapalignment and light duty hook latches arestandard on all models. Repairs are easilydone in the field.SolidFiberglassHandle360°Forged SteelHooksNon-ConductiveWinding WheelPolyester WebStrapHSSLCat. No. Single Line Double Line Handle Weight ea.Capacity Lift Min. Headroom Capacity Lift Min. Headroom Lengthlbs. ( kgs ) ft. ( m ) in. ( mm ) lbs. ( kgs ) ft. ( m ) in. ( mm ) in. ( mm ) lbs. ( kgs )300LMH 1500 ( 681 ) 14 ( 4.2 ) 20 ( 508 ) 3000 ( 1362 ) 7 ( 2.1 ) 23 ( 584 ) 24 ( 610 ) 12.5 ( 5.6 )300DLMH* 1500 ( 681 ) 14 ( 4.2 ) 20 ( 508 ) 3000 ( 1362 ) 7 ( 2.1 ) 23 ( 584 ) 24 ( 610 ) 13 ( 5.9 )344DLMH* 2000 ( 908 ) 11 ( 3.3) 20 ( 508 ) 4000 ( 1816 ) 5.5 ( 1.65 ) 23 ( 584 ) 30 ( 762 ) 13.5 ( 6.1 )*Add suffix “HSSL” to Cat. No. if optional Hot Stick Safety Latch is required. Contact factory for prices.SALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401I-9


UNIVERSAL FITTINGSUniversal Fittings, constructedof bronze oraluminum, can be installedon universal sticks orclamp sticks by using the2500 shotgun adapter.2500 Shotgun Adaptor.4 lbs ( .2 kgs )4236 Tree / Wire Hook.36 lbs. ( .2kgs )9878 Pig Tail Disconnect.4 lbs ( .2 kgs )9838 Chuck BlankInside Depth: 1/2” x 1 1/2” ( 13 x 38mm ).4 lbs ( .2 kgs )9971 Light Duty Cutout Prong.4 lbs ( .2 kgs )9969 Heavy Duty Disconnect Head.6 lbs ( .3 kgs )9970 Prong Disconnect.4 lbs ( .2 kgs )4099 Rotary Prong Tie Head.6 lbs ( .27 kgs )4100 Rotary Blade Tie Head.7 lbs ( .3 kgs )9839 Pointed Disconnect.4 lbs ( .2 kgs )4101 Double Prong Tie Head.5 lbs ( .22 kgs )4102 Fixed Blade Tie Head.5 lbs ( .22 kgs )I-10SALISBURY Hot Sticks and Tools. www.wh<strong>salisbury</strong>.com


UNIVERSAL FITTINGS4108 Tubular Line Cleaner4109 Replacement Brush1.3 lbs ( .6 kgs ).5 lbs ( .22 kgs )4111 “V” Line Cleaner4113 Replacement BrushesCarton of ten1.3 lbs ( .6 kgs )3 lbs ( 1.4 kgs )4106 Curved Blade Skinning Knife.4 lbs ( .2 kgs )4107 Replacement Blade.1 lbs ( .05 kgs )4103 Handle for pruning saw.5 lbs ( .22 kgs )4104 Pruning Saw w/ 18”(457mm) blade.5 lbs ( .22 kgs )4181 Hack Saw, w/ replaceable blades.6 lbs ( .3 kgs )9834 Clamp Stick Head1.4 lbs ( .6 kgs )4105 Tree PrunerMounted on 12’ ( 3.6m ) fiberglass pole,complete with 25’ ( 7.62m ) of line.4 lbs ( .2 kgs )UST Universal System ToolBlanket Pin1 lb. ( .45 kgs )4114 Flex Head Socket Wrench1.2 lbs ( .5 kgs )4115 Ratchet Wrench1/2” ( 12.7 mm ) sq. drive.5 lbs ( .22 kgs )SALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401I-11


STORAGE FOR HOT STICKS & TOOLS1193119241551191SALCOR® Tool Holders secure tools to trailers,compartments and tool rooms. 12 per package.Cat. No. Description lbs. ( kgs )1191 1 ( 25mm ) I.D. Tool Holder 3 ( 1.4 )1192 1.25 ( 32mm ) I.D. Tool Holder 3.5 ( 1.6 )1193 1.75 ( 44mm ) I.D. Tool Holder 3.75 ( 1.7 )Hot Stick Bags are constructed of heavy vinylwith double stitched seams. Flaps snap closed. 6”(152mm) wide and designed to hold sticks up to4” (102mm) shorter than bag length shown onchart.Telescoping Stick Canvas Bags are designed tohold all telescoping sticks.Tubular PVC Storage Containersprovide weather tight storage. Kitincludes two mounting bracketsand four steel bolts with each 6”(152mm) I.D. or 4.1” (104mm)tube. Sized for tools 12” (305mm)shorter than tube. Four mountingbolts 3/8” x 1.5” (9.5 x 38mm)are supplied with each container.Kit may be ordered without tubing,or with mounting brackets only.40575.75” (146mm) or8” (203mm) widthCat. No. Description/Dimensions in. ( mm ) lbs. ( kgs )9822 Kit for 6” ( 152 ) I.D. 6.6” ( 168 ) O.D. tube 8 ( 3.5 )9824 2 Brackets for 6” ( 152 ) tubing only 4 ( 1.8 )9823 Kit for 4.1” ( 104 ) I.D. 4.5” ( 114 ) O.D. tube 6 ( 2.7 )9825 2 Brackets for 4” ( 102 ) tubing only 4 ( 1.8 )Cat. No. Length Weight ea.Feet meters lbs. ( kgs )HOT STICK BAGS4297 5 1.5 .7 ( .3 )4298 6 1.8 .8 ( .3)4299 6’ 4” 1.9 .9( .4 )4300 7 2 1 ( .4 )4301 8’4” 2.5 1.1 ( .5 )4302 9 2.7 1.2 ( .5 )4303 10’4” 3 1.4 ( .6 )TELESCOPING STICK CANVAS BAG4057 5’6” 1.7 2.5 ( 1.2 )6” I.D. TUBULAR PVC STORAGE KIT4167 6 1.82 20 ( 9 )4168 7 2.13 22 ( 10 )4169 9 2.74 26 ( 11.7 )4170 11 3.35 30 ( 13.5 )4171 13 3.96 34 ( 15.3 )4172 15 4.57 38 ( 17.1 )4173 17 5.18 42 ( 18.9 )4174 19 5.79 46 ( 20.7 )4175 21 6.4 50 ( 22.5 )4176 23 7.01 54 ( 24.3 )4177 25 7.62 58 ( 26.1 )4” I.D. TUBULAR PVC STORAGE KIT4155 7 2.13 17 ( 7.7 )4156 9 2.74 20 ( 9 )4157 11 3.35 24 ( 10.8 )4158 13 3.96 27 ( 12.2 )4159 15 4.57 30 ( 13.5 )4160 17 5.18 34 ( 15.3 )4161 19 5.79 37 ( 16.7 )4162 21 6.4 40 ( 18 )4163 23 7.01 44 ( 19.8 )4164 25 7.62 47 ( 21.2 )4165 27 8.23 50 ( 22.5 )I-12SALISBURY Hot Sticks and Tools. www.wh<strong>salisbury</strong>.com


FIBERGLASS HOT CLAMPSTICKS REPAIR PARTS LISTExternal RodRef. No. Cat. No. Description1 20178 Dog2 20260 Roll Pin .125” Dia. x .5” Lg. ( 3.2 x 13mm )3 20174 Ferrule4 2398 Disc Seal5 20134 Grooved Pin .187 Dia. x 1.593 Lg. ( 4.7 x 40mm )6* 20265-1 Operating Rod7* 20381 Operating Rod Guide8 20114 Phenolic Pin .187 Dia. x 1.437 Lg. ( 4.7 x 36.5mm )9 20250 Handguard Sleeve10* 20114 Hot Stick Blank 1.25” Dia. (32mm)11 20262 Roll Pin .125 Dia. x .56 Lg. ( 3.2 x 14mm )12 20251 Operating Rod Connector13 20258 Hex Socket Set Screw .375-16 x 1.2514 20257 Flat Head Screw 10-32 x 1.125 Lg. ( 254-813 x 29 )15 20253 Adjustment Block16 20254 Compression Spring17 20139 Button18 20263 Roll Pin .125 Dia. x .75 Lg. ( 3.2 x 19 )19 20445 10-32 Hex Jam Nut20 20443 Hex Head Machine Screw 10-32 x 1.2521 20140 Trigger22 20255 Torsion Spring23 20141 Handgrip24 20142 Rack for Handgrip25 20257 Flat Head Screw 10-32 x 1.125 Lg. ( 254-813 x 29 )26 20252 Handgrip Sleeve27 1959 End Cap28 20176 Jaw Hook29 20332 Roll Pin .25 Dia. x .47 Lg. ( 6 x 12 )30 20470 Hook Spring31 20177 Hook HolderAssembly No. Description Consist of Parts4317 Hook Assembly 28, 29, 30, 314318-4324 Operating Rod Assembly* 1, 2, 6, 11, 124325-4331 Hot Stick Assembly* 3, 4, 5, 8, 9, 10, 14, 24, 27, 30*Please specify clampstick catalog number when ordering this component part.SALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401I-13


FIBERGLASS TELESCOPING HOT STICKRepair ListStandard Duty ModelMODEL No.405220130203820347- Section #7For 405118472062320346- Section #6For 405020345- Section #5For 404920344- Section #4For 40482037 2036 2035 2034 2033184620623184520623184420624184320625405140504049404818422062620322036820366435817891952206274365 4364 4363 4362 4361 43602013020382037 2036 2035 2034 203320347- Section #7For 406120346- Section #6For 406020345- Section #5For 405920344- Section #4For 4058203240584059406040614357Tip Lock Model40621. Every tip section comes assembledwith bushing epoxied in.2. Tip section for tip lock model comes withtip lock button permanently installed.3. Every lock and/or plug for section 2 through8 requires two 3/16” dia. (comp #20367)20130Heavy Duty Model20347- Section #6For 4055MODEL No.40564055405440532038 2037 2036 2035 2034 2033184720346- Section #5For 4054184620345- Section #4For 405318451844184318424359206232062320623206242062520626178919524365 4364 4363 4362 4361 43601. Tip section for Heavy Duty Modelcomes with bushings epoxied in.2. Every lock and/ or plug requires two 3/16”3. Every lock and/or plug for sections 2-8dia. pins (comp #10367)require two 3/16” Dia.( 4.8mm ) pins(#20367)I-14SALISBURY Hot Sticks and Tools. www.wh<strong>salisbury</strong>.com


INSULATORSSALVAR® Insulators - IntroductionSI Series Silicone Insulators9502L-EP InsulatorsS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401J-1


SALVAR® INSULATORSSALVAR® Composite Insulators combine the technologiesof fiberglass reinforced rod, metal fittings and ourextensive knowledge of elastomeric insulation to produce ahigh quality composite insulator. Since 1980 thousands ofSALVAR Insulators have been installed by utilities worldwidein a variety of environments. Continued outstandingperformance is proof of their superior quality and design.Design: Unibody Design insulators are one-piece injectionmolded directly to the rod and sealed to the end fittingswith a bead of silicone to give the insulator high dielectricstrength and protect it from all environmental conditions.This design is used for standard distribution dead end/suspension insulators.Weathersheds and Coverings: In accelerated outdoortests, Super SALCOR® is shown to defy the damagingeffects of ultraviolet rays for the equivalent of 50 yearsand offer better resistance to tracking than porcelain.Fiberglass Rod: A high quality, corrosion resistant,fiberglass reinforced rod is the core of every insulatorwith ultimate mechanical strength at least twice themaximum working load.End Fittings: Standard distribution dead/end suspensionunits are supplied with clevis and tongue fittings meetingANSI C29-2 specifications. Ball, socket, and eye fittingsare also available. All are made of hot dipped galvanizedhigh strength carbon steel (stainless steel available uponrequest) and have an ultimate tensile strength rating of15,000 pounds. All end fittings on dead/end suspensioninsulators are attached by compression. Every insulator isproof tested to verify the crimp.Unibody insulators have end fittings sealed with silicone to eliminate any possibility ofmoisture or contamination from reaching the fiberglass rod.S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401J-3


SI SERIES SILICONE INSULATOR15kV to 46kVDead End/Suspension, Tongue & ClevisThe SI Series of SALVAR®Insulators featuring a siliconeformulation of our SuperSALCOR® weathershed material.Salisbury combined the excellenthydrophobic and electrical qualitiesof silicone with an optimumweathershed design and corrosionresistant fiberglass rod to produce astate-of-the-art insulator whichmeets or exceeds industry requirements.The insulators were testedin accordance with ANSI C29 andIEC1109. End fittings are hotdipped galvanized high strengthcarbon steel*, providing a 15,000pound ultimate tensile strength.100% proof testing ensurestrouble-free installation.Unibody insulators have endfittings sealed with silicone toeliminate any possibility ofmoisture or contamination fromreaching the fiberglass rod.*Stainless steel end fittings available upon request.Contact your Salisbury representative for details.9501U-SI 9502U-SI 9503U-SIClass DS-15 DS-28 DS-35, DS-46No. of Weathersheds 5 9 13Length-in ( m ) 12.5 ( .32 ) 16.5 ( .42 ) 22 ( .56 )Dia. of Weathersheds-in ( mm ) 3 ( 76 ) 3 ( 76 ) 3 ( 76 )Leakage Distance-in ( m ) 15 ( .38 ) 26.5 ( . 67 ) 39 (1 )Electrical Critical Impulse 140 190 280Ratings Dry, 60 Hz 90 130 180kV Wet, 60Hz 65 100 145Radio Test--kV Ground 15 20 30Influence Max RIV-1000kHz µV


THE 9502L-EP INSULATOR27kVThe new 9502L-EP Insulator combinesthree essential characteristics:PERFORMANCE - The 9502L-EP is theonly composite insulator manufactured as areplacement for two 10” (254mm) porcelaindisks. Installation is limited to horizontaldead-end applications only.QUALITY - Supplying the electric industrywith polymer composite insulators for over20 years, our original formulation of EPDMSALCOR® material has withstood the testof time.INNOVATION - Unlike any other insulatoron the market, the unique shed design of the9502L-EP minimizes the material contentwithout compromising electrical or dimensionalrequirements.Insulators are hot dipped galvanized highstrength carbon steel*.*Stainless steel end fittings available upon request.Contact your Salisbury representative for details.9502L-EPNo. of Weathersheds 5Length-in ( m ) 11.5 (. 29 )Dia. of Weathersheds-in ( mm ) 5 ( 127 )Leakage Distance-in ( m ) 22 ( .56 )Electrical Critical Impulse 189Ratings Dry, 60 Hz 116kV Wet, 60 Hz 92Radio Test--kV Ground 20Influence Max RIV--1000Hz µV 1Typ. Appl--kV, Ø-Ø 27Ultimate Strength-SML- lbs / kN 15000 / 70Net Weight ea.-lbs ( kgs ) 2.8 ( 1.3 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401J-5


ACCESSORIESCanvas Buckets and BagsGlove and Sleeve BagsBlanket Canisters and Roll-UpsStorage for Hot Sticks and ToolsSwitchboard Matting, Climber Guards and Rescue HookSpecial EquipmentCleaning ToolsSpecial EquipmentArc Suppression BlanketArc Flash ProtectionS ALISBURYTraining and Safety AidsSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401Cleaners, Sunscreen and SuppliesX-1


CANVAS BUCKETS AND BAGS403062250Salisbury Tool Buckets are constructed of extraheavy-dutycanvas duck and reinforced with aone-piece formed leather bottom with a 3” (76mm)cuff for rugged service and long life. The standardtool buckets, 30 and 40, are both collapsible foreasy storage and feature a poly braid rope handle.The oval tool bucket, 50, designed to attach toaerial baskets, features 6 inner tool pockets andtwo plastic hanging hooks.Salisbury Tool Bags are useful for carrying andstoring all sorts of equipment and tools. Constructedfor long life and rugged service from onepiece of #8 white canvas fastened to a steel frame.The synthetic leather bottom is cemented anddouble stitched to the bag and protected with steelstuds and a reinforcing 3.5” (89mm) cuff. Handlesand straps are made of top grain harness leather.Line Hose and Blanket Bags are convenient forraising and lowering bulky items up and down apole, as well as for storage. Constructed of #6duck, sewn with nylon thread, and reinforced witha weatherproof leather with a 3” (76mm) cuff foradded strength. Features a cycolac top ring to holdthe bag open and a strong 1/2” (12.7mm) polybraid rope handle, reinforced with leather. 7”(178mm) diameter bags are used for conventionalstyle line hose, while the 12” (305mm) diameter bagswere designed for Class 4 extended lip line hose.Cat. No. Dimensions Weight ea.in. ( mm ) lbs. ( kgs )STANDARD TOOL BUCKETS30* 12 x 16 ( 305 x 406 ) 3.2 ( 1.45 )40* 8 x 14 ( 203 x 356 ) 2 ( .91 )OVAL TOOL BUCKET50* 7x14x10 ( 1715x356x254 ) 2.5 ( 1.14 )PH55 yellow vinyl hooks for #50 .5 ( .23 )STANDARD Tool Bags- 5.5” (140mm) wide616 16 x 13.5 ( 406 x 343 ) 3.3 ( 1.5 )618 18 x 15.5 ( 457 x 394 ) 3.8 ( 1.73 )620 20 x 15.5 ( 508 x 394 ) 4.2 ( 1.91 )622 22 x 15.5 ( 559 x 394 ) 4.3 ( 1.95 )624 24 x 15.5 ( 610 x 394 ) 4.5 ( 2.04 )EXTRA WIDE Tool Bags-9.5” (241mm) wide2419B 24 x 19 ( 610 x 483 ) 4.1 ( 1.86 )LINE HOSE BAGS48* 7 x 48 ( 178 x 1219 ) 2.8 ( 1.27 )60* 7 x 60 ( 178 x 1524 ) 3.0 ( 1.36 )66* 7 x 66 ( 178 x 1676 ) 3.3 ( 1.5 )72* 7 x 72 ( 178 x 1829 ) 3.5 ( 1.59 )1248* 12 x 48 ( 305 x 1219 ) 3.8 ( 1.73 )1266* 12 x 66 ( 305 x 1676 ) 5.3 ( 2.41 )BLANKET BAG1230 12 x 30 ( 305 x 762 ) 3.2 ( 1.45 )*add suffix “S” if optional iron swivel snap is desiredS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401X-3


GLOVE AND SLEEVE BAGSGB116GB116-GCT31T32Crush Resistant Lining of T32Proper storage extends the service lifeof linemen’s gloves and sleeves.Folds and creases strain rubber andcause it to crack from ozone prematurely.By storing rubber gloves andsleeves in the right size bag or roll-up,and never forcing more than one pairinto each bag, equipment will lie flatand last longer.Salisbury bags and roll-ups areconstructed of heavy duty canvasduck and are double stitched andriveted at stress points for extradurability. Canvas bags feature a Dring for hanging in trucks or on workbelts. Bags feature tapered gussetswith wide opening tops for easyinsertion. The T32 bag contains a hardplastic lining to create a crush resistantenvironment for your sleeves. TheSalisbury canvas sleeve roll is specificallydesigned to allow safe storage ofsleeves without severe straining orfolding of the rubber. When rolled thesleeve roll can be hung in trucks toprotect sleeves from damage.Cat. No. For Glove Dimensions Weight ea.length in. ( mm ) inches ( mm ) lbs. ( kgs )26 oz. CANVAS GLOVE BAGSGB112 11 ( 280 ) 9” x 14” ( 229 x 356 ) 1 ( .5 )GB114 14 ( 356 ) 9” x 16” ( 229 x 406 ) 1 ( .5 )GB116 16 ( 406 ) 9” x 18” ( 229 x 457 ) 1.2 ( .6 )GB118 18 ( 457 ) 9” x 20” ( 229 x 508 ) 1.5 ( .7 )26 oz. CANVAS GLOVE BAGS w/ goggle caseGB114-GC 14 ( 356 ) 9” x 16” ( 229 x 406 ) 1 ( .5 )GB116-GC 16 ( 406 ) 9” x 18” ( 229 x 457 ) 1.2 ( .6 )GB118-GC 18 ( 457 ) 9” x 20” ( 229 x 508 ) 1.5 ( .7 )#8 CANVAS GLOVE & SLEEVE BAG*2C16 14 ( 356 ) 16 ( 406 ) 9” x 18” ( 229 x 457 ) 1.2 ( .6 )2C18 18 ( 457 ) 9” x 20” ( 229 x 508 ) 1.5 ( .7 )#8 CANVAS SLEEVE BAGT31 - 33” x 9.5” ( 836 x 241mm) 1.5 ( . 7 )T32 - 33” x 9.5” ( 836 x 241mm) 3 ( 1.4 )14 oz. CANVAS SLEEVE ROLL-UPSR130 - 32” x 19” ( 813 x 482mm ) 1.4 ( . 6 )*Designed for use with SALCOR Type II sleeves only.Not recommended for natural rubber.X-4SALISBURY Accessories. www.wh<strong>salisbury</strong>.com


BLANKET CANISTERS AND ROLL-UPSBlanket Roll-ups are constructedof 12 oz. (.36g) waterresistant cotton duck with sideflaps to confine the blankets intoposition and prevent damage tothe edges. Waterproof and treatedagainst mildew. Two heavy webstraps with buckles close the rollup,and a double web cross strapserves as a carrying handle.Blanket Canisters-molded inbright orange, hi-impact polyethylene-protectinsulating blanketswhen not in use. A tight-fittingcap is secured to the canisterwith polypropylene rope.P2P4P622Cat. No. Fits Blanket Dimensions Capacity Weight ea.Description Max Size in. ( mm ) in. ( mm ) # blankets lbs. ( kgs )22 Roll-up 22 ( 559 ) 41 x 33 ( 1041 x 838 ) 1-4 blankets 1.5 ( .68 )36 Roll-up 36 ( 914 ) 54 x 46 ( 1041 x 838 ) 1-4 blankets 2.5 ( 1.1 )46 Roll-up 46 ( 1168 ) 54 x 46 ( 1041 x 838 ) 1-4 blankets 4 ( 1.8 )P2 Canister 36 ( 914 ) 5 x 37 ( 127 x 940 ) 1-2 blankets 2 ( .9 )P3 Canister 36 ( 914 ) 6 x 37 ( 127 x 940 ) 1-3 blankets 3 ( 1.4 )P4 Canister 36 ( 914 ) 7 x 37 ( 127 x 940 ) 1-4 blankets 3.5 ( 1.6 )P6 Canister 36 ( 914 ) 9 x 37 ( 127 x 940 ) 1-6 blankets 5 ( 2.3 )P3-47 Canister 46 ( 1168 ) 6 x 47 (152 x 1194) 1-2 blankets 4 ( 1.8 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401X-5


STORAGE FOR HOT STICKS & TOOLS1193119241551191SALCOR® Tool Holders secure tools to trailers,compartments and tool rooms. 12 per package.Cat. No. Description lbs. ( kgs )1191 1 ( 25mm ) I.D. Tool Holder 3 ( 1.4 )1192 1.25 ( 32mm ) I.D. Tool Holder 3.5 ( 1.6 )1193 1.75 ( 44mm ) I.D. Tool Holder 3.75 ( 1.7 )Hot Stick Bags are constructed of heavy vinylwith double stitched seams. Flaps snap closed. 6”(152mm) wide and designed to hold sticks up to4” (102mm) shorter than bag length shown onchart.Telescoping Stick Canvas Bags are designed tohold all telescoping sticks.Tubular PVC Storage Containersprovide weather tight storage. Kitincludes two mounting bracketsand four steel bolts with each 6”(152mm) I.D. or 4.1” (104mm)tube. Sized for tools 12” (305mm)shorter than tube. Four mountingbolts 3/8” x 1.5” (9.5 x 38mm)are supplied with each container.Kit may be ordered without tubing,or with mounting brackets only.40575.75” (146mm) or8” (203mm) widthCat. No. Description/Dimensions in. ( mm ) lbs. ( kgs )9822 Kit for 6” ( 152 ) I.D. 6.6” ( 168 ) O.D. tube 8 ( 3.5 )9824 2 Brackets for 6” ( 152 ) tubing only 4 ( 1.8 )9823 Kit for 4.1” ( 104 ) I.D. 4.5” ( 114 ) O.D. tube 6 ( 2.7 )9825 2 Brackets for 4” ( 102 ) tubing only 4 ( 1.8 )Cat. No. Length Weight ea.Feet meters lbs ( kgs )HOT STICK BAGS4297 5 1.5 .7 ( .3 )4298 6 1.8 .8 ( .3 )4299 6’ 4” 1.9 .9( .4 )4300 7 2 1 ( .4 )4301 8’4” 2.5 1.1 ( .5 )4302 9 2.7 1.2 ( .5 )4303 10’4” 3 1.4 ( .6 )TELESCOPING STICK CANVAS BAG4057 5’6” 1.7 2.5 ( 1.2 )6” I.D. TUBULAR PVC STORAGE KIT4167 6 1.82 20 ( 9 )4168 7 2.13 22 ( 10 )4169 9 2.74 26 ( 11.7 )4170 11 3.35 30 ( 13.5 )4171 13 3.96 34 ( 15.3 )4172 15 4.57 38 ( 17.1 )4173 17 5.18 42 ( 18.9 )4174 19 5.79 46 ( 20.7 )4175 21 6.4 50 ( 22.5 )4176 23 7.01 54 ( 24.3 )4177 25 7.62 58 ( 26.1 )4” I.D. TUBULAR PVC STORAGE KIT4155 7 2.13 17 ( 7.7 )4156 9 2.74 20 ( 9 )4157 11 3.35 24 ( 10.8 )4158 13 3.96 27 ( 12.2 )4159 15 4.57 30 ( 13.5 )4160 17 5.18 34 ( 15.3 )4161 19 5.79 37 ( 16.7 )4162 21 6.4 40 ( 18 )4163 23 7.01 44 ( 19.8 )4164 25 7.62 47 ( 21.2 )4165 27 8.23 50 ( 22.5 )X-6SALISBURY Accessories. www.wh<strong>salisbury</strong>.com


SWITCHBOARD MATTING, CLIMBER GUARDS & RESCUE HOOKSwitchboard Matting is placed permanently placed infront of switchgear, motor control centers andother high voltage apparatus to provide personalprotection for workers. It is also used whentending take-up and pay out reels and whenadding or replacing conductors. Made fromhigh quality Type II rubber, Class 2matting is 1/4” (6.4mm) thick and is testedto 20kV, and Class 4 matting is 1/2” thickand tested to 40kV. Both Classes of mattingcomply with ASTM D178, Class 2 and Class 4 specifications.The corrugated surface acts as a safety tread whilereducing the possibility of metal particles becomingembedded. Class 2 Switchboard matting is available in 25yard rolls or custom cut to specified lengths, while Class4 matting is sold in 20 yard rolls only.M36-2Matting Cross-SectionMaximum Use Voltage Class 2, 17,000 volts, Class 4,36000 volts.Climber Guards are manufactured by the dippingprocess using the same formulation of rubber as ourlineman’s insulating gloves and sleeves. Climber Guardsare furnished un-slit to accommodate any length, regularor adjustable climbers. Sold in pairs only.21187Salisbury Insulated Rescue Hook is an invaluable toolfor any workplace used to withdraw an injured workerout of a hazardous area. Confined spaces, in vaults, orjust near electrical cabinets and switch gear are some ofthe places where this tool is a must. Featuring a foamfilled, fiberglass reinforced handle for superior electricalinsulation and a coated heat treated body hook with an18” opening. The stick is available in the standard lengthsof 6 and 8-foot lengths. Other lengths are available as aspecial order. Contact us with your requirements.Cat. No. Dimensions Weight per yardin. ( mm ) lbs. ( kgs )NEWSWITCHBOARD MATTING - CLASS 2M24-2 1/4 x 24 ( 6 x 610 ) 9 ( 4.1 )M30-2 1/4 x 30 ( 6 x 762 ) 12 ( 5.4 )M36-2 1/4 x 36 ( 6 x 914 ) 15 ( 6.8 )M48-2 1/4 x 48 ( 6 x 1219 ) 18 ( 8.2 )SWITCHBOARD MATTING - CLASS 4M36-4 1/2” x 36” x 60’ long (12mm x 914 mm x 18.3m) 684 (308)(roll)CLIMBER GUARDS21187 sold in pairs .5 ( .23 )INSULATED RESCUE HOOK24401 Rescue Hook 6’ (1.8 m) length 4.5 ( 2 )24403 Rescue Hook 8’ (2.4 m) length 5.5 ( 2.5 )Insulated Rescue HookS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401X-7


ACCESSORIESCompound Pots are made of hard rubber that isnonconductive and breakage resistant. The applicatorbrush and compound are held in one unit thatcan be hung from aerial devices or fit into crossarm holes. Offered in single and double compartmentstyles.Cable Bandages provide temporary insulation forbare conductors and splices. A single thickness ofthe orange SALCOR® Bandage can withstand15kV on puncture test. The Black Neoprenebandage provides fast and complete temporarycover for cable splicers.PJB144OSInsulating Saddles are ideal for temporary oremergency line work such as stringing lightconductors over short spans. The large 3” (76mm)upper saddle opening will hold bare or insulatedconductors in either an upright or inverted position.Molded of hard rubber and furnished with twonylon holding pins supplied with steel loops foreasy hot-stick application. A 12” (305mm) orangeplastic shoe is affixed to the crossarm opening tohelp prevent flashover during inclement weather.Designed to fit crossarms with dimensions up to3.75” x 5” (95mm x 127 mm).IS10Cat. No. Description Weight ea.in. ( mm ) lbs. ( kgs )COMPOUND POT SINGLE COMPARTMENTPJB1 1pt. w/ bristle brush 4.5” x 3.5” ( 114 x 89 ) 1.5 ( .681 )PJB2 1 pt. w/ wire brush 4.5” x 3.5 ( 114 x 114 ) 1.5 ( .681 )COMPOUND POT DOUBLE COMPARTMENT4190 2-1 pt. comp. w/ bristle brush 5.75” x 4.75” ( 146x121 ) 2 ( .908 )20850 2-1 pt. comp. w/ wire brush 5.75” x 4.75” ( 146x121 ) 2 ( .908 )CABLE BANDAGES44OS Orange SALCOR 4’ ( 1.2m ) w/ strap 1 ( .5 )414PG Pure Gum Rubber 14’ ( 4.3m ) w/o strap 1 ( .5 )414BN Black Neoprene 14’ ( 4.3m ) w/o strap 1 ( .5 )INSULATING SADDLEIS10 11.25 x 4.75 ( 286 x 121 ) 4 ( 1.8 )ISP Replacement Pin .25 ( .1 )X-8SALISBURY Accessories. www.wh<strong>salisbury</strong>.com


CLEANING TOOLSTubular Brushes are preferred whenrubber gloving or working on de-energizedconductors. The damage to rubber glovesis minimal because the steel bristles areinternal. The 2.5” (63.5mm) tubular brushis used in confined areas such as betweentwo connectors or clamps.41104337“V” Type Wire Brush has an epoxycoated handle. Replacement brushes areavailable.4108411341124111Cat. No. Description Weight ea.in. ( mm ) lbs. ( kgs )4110 5 ( 127 ) Tubular 0.4 ( 0.2 )4337 2.5 ( 63.5 ) Tubular 0.2 ( 0.1 )4108 Universal Tubular 1.3 ( 0.6 )4112 “V” Type handle w/ brushes 1.2 ( 0.6 )4113 “V” Type carton of 10 replacement brushes 3 ( 1.4 )4111 Universal “V” Line Cleaner 1 ( 0.5 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401X-9


SPECIAL EQUIPMENTH7TH111BELT HOOK/BREAK-AWAY isnonconductive yellow nylon hand-linebelt hook that will bend or break ifsuddenly pulled.TDThe TD TAGGING DEVICE, madefrom molded orange SALCOR®, isused to tag opened disconnectswitches. It allows “Hold” cards to beplaced on the circuit and fits over theheads of 1-1/4’ (32 mm) and 1-1/2’(38 mm) switch sticks.NEWMETER TERMINAL COVER is usedto avoid accidental contact withenergized parts on 100 and 200 Ampsingle phase meter sockets. Made oforange SALCOR corona-resistantmaterial.Spade CoverApplicationSC5SC6GSpade Covers are easily installed toprovide temporary insulation whenworking in padmount transformers andother electrical apparatus. Or, whensecurely held in place, they may be lefton spades or connectors indefinitely forfront end protection. The larger SC-5 isalso used to cover primary elbows aswell as the larger and longer multiplelead primary and secondary fittings andlugs used in underground enclosuresand vaults. Molded from flexibleSALCOR, they have excellent aging andweathering characteristics. Theopening at the top end of the slot holdsthe cover on to the terminal. Wide lipsextending along the slot provide additionalprotection over the connection.Cat. No. Description / Dimensions Weight ea.in. ( mm ) lbs. ( kgs )BELT HOOK / BREAK-AWAYH7 Break-Away Belt Hook 1 oz. ( .03 )TAGGING DEVICETD 7.25 ( 184 ) longslot: 2.13 x .63 (5 4 x 16 ) .25 ( .1 )cup: 2.5 x 1.75 ( 64 x 44 )METER TERMINAL COVERTH111 3 x 3.5 x 1.5 ( 76 x 89 x 38 ) 1.6oz. ( .05 )SPADE COVER - CLASS 2SC4 2.6 x 4.4 x 10.6 ( 66 x 112 x 270 ) 1.4 ( .5 )SC5 3 x 6 x 10 ( 76 x 152 x 254 ) 2 ( .9 )SC6 2.5 I.D. x 7.5 x 10 ( 64 I.D. x 191 x 254 ) 1.4 ( .5 )SC6G Gray, 2.5 I.D. x 7.5 x 10 ( 64 I.D. x 191 x 254 ) 1.4 ( .5 )X-10SALISBURY Accessories. www.wh<strong>salisbury</strong>.com


ARC SUPPRESSION BLANKETThe Arc Suppression Blanket is to beused as a barrier for protection fromthe explosive and incendiary effects ofelectrical arcs and flashes. These hazardouselectrical discharges can be causedby faults in cables, in cable splices andjoints, and at transformer terminals, orthey may be generated by the operationof switch gear, circuit breakers andlightning arrestors. The blanket can beused for worker protection in undergroundvaults, switchyards, and in otherlocations where electrical equipmentposes a risk of exposure to explosiveelectrical discharges.ARC48Because of the unpredictability ofelectrical discharges, the Arc SuppressionBlanket may not totally contain arcsand flashes, but only reduce or limitexplosive and incendiary effects. In suchcases, injuries may still occur, even whenthe blanket is properly used.P4Cat. No. Dimensions Description Weight ea.in. ( mm ) lbs. ( kgs )ARC45 48 x 60 ( 1219 x 1524 ) w/ P-4 Canister 7.5 ( 3.4 )ARC48 48 x 96 ( 1219 x 2438 ) w/ P-4 Canister 9 (4.1)21655 48 x 60 ( 1219 x 1524 ) Blanket Only 4.5 ( 2 )21656 48 x 96 ( 1219 x 2438 ) Blanket Only 6 ( 2.7 )P4 7 x 37 ( 178 x 940 ) Canister 3 ( 1.4 )S ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401X-11


ARC FLASH PROTECTIONSalisbury offers an entire line of Arc FlashProtective Clothing and Equipment rangingfrom 8 cal/cm² to 100 cal/cm².Ask your local Salisbury representative for acopy of our Arc Flash Protection Catalog ordownload it from our website atwh<strong>salisbury</strong>.com.X-12SALISBURY Accessories. www.wh<strong>salisbury</strong>.com


TRAINING AND SAFETY AIDSContact your local W.H. Salisbury &Co. Distributor, Representative or ourCustomer Service Department forinformation and availability on any ofour Training and Safety Aids. Films mayeither be borrowed on a free loan basisfrom our film library or purchased ifdesired. As these programs are inconstant circulation please give as muchnotice as possible so that we can easilymeet your scheduled request.Title Description LengthLive line Maintenance Video showing the rubber glove method of live line 22 min.Gloving 15kVmaintenance at 15 kV.Shields of Safety Video describing the manufacture use, 15 min.storage and field care of Rubber Insulating EquipmentGuides to Grounding Video covering the rules and guides to 16min.grounding procedures and practices.Field Inspection Video showing the recommended methods for field inspection 17 min.of rubber protective equipment.Surge Testing Video showing the laboratory surge tests of grounding equipment. 15 min.Stop BookletGeneral rules for care and inspection of protective insulating equipment.Care & Inspection ChartPoster about how to recognize damaged personal protective equipment.ASTM ChartDescribes ASTM classes, voltages and colorsS ALISBURYSetting industry standards since 1855. 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501 Fax 847.679.2401X-13


CLEANERS, SUNSCREEN AND SUPPLIESNEW1461146010-41451RUB-OUT is a non-petroleum-based handcleaner for workers who wear rubber gloves andsleeves. Dissolves and removes grease, oil, ink,tar, pipe dope, creosote, paint and more withoutharming rubber or SALCOR®. Cleans with orwithout water. Contains natural skin conditionersand leaves a fresh citrus scent.Salisbury’s RUB-OUT Towelettes arepremoistened heavy duty hand cleaner towels thatwork fast to loosen, dissolve, and absorb dirt andgrease, and will not harm rubber gloves! Ourpowerful yet safe cleaning agents work togetherwith an absorbent, nonscratching abrasivecleaning towel. The citrus-based formula easilyremoves soil from your hands and leaves themcleaned and conditioned anywhere you’reworking. And after cleaning your hands there isenough absorbency to clean your tools and othersurfaces with the same towel. These shop size(10.5” x 12.25”) durable towels quickly removetough-to-clean substances including lubricants, tar,oils, wax, caulk and much more.TEN-FOUR GLOVE DUST is a cooling, frictionlesspowder that absorbs moisture and perspirationwhen wearing rubber gloves. Provides extracomfort while preventing gloves from gettingsticky. The 6-oz. bottle easily fits in a pocket orglove bag. The 4-quart bulk package is used in testlabs as a dusting powder when cleaning and testing.SUPER SALCO® is a concentrated detergentwith a special grease release formula that removesoils, grease and dirt from rubber and SALCORequipment. Suitable for washing linemen’s rubbergloves, sleeves and other specialty equipment, byhand or in commercial washing machines. Alsoworks well on fiberglass and other materials. Justdilute with water, apply with a rag or sponge andrinse thoroughly.S-99 S55SS30Cat. No. Description Weight ea.lbs. ( kgs )RUBOUT HAND CLEANER1450 4.5 oz. ( 130g ) tubes, 12/pack 4 ( 1.8 )1451 16 oz. ( .45kg ) can, 12/pack 16 ( 7.3 )1452 4.5 lbs. ( 2kgs ) cans, 6/pack 28 ( 12.7 )1453 Dispenser for 4.5lb. ( 2kg ) can 1 ( .5 )RUBOUT TOWELETTES1460 Bucket of 60, 6 buckets / Case 14 ( 6.4 )1461 Single Packets, 100 Singles / Case 3 ( 1.4 )TEN-FOUR GLOVE DUST10-4 12 @ 6 oz. ( 170g ) squeeze bottles 5.5( 2.2 )10-4-4QT 4 quarts ( 3.8 ltrs. ) bulk, single 8 ( 3.6 )SUPER SALCO DETERGENTS4 1 gal ( 3.8 ltr. ) jugs, 4 pack 54( 24.5 )S5 5 gal ( 19 ltr. ) drum 49 ( 22.3 )S55 55 gal ( 208 ltr. ) drum 540 ( 245 )SALCON SILICONE SPRAYS-99 Aerosol can 16 oz. ( .454 )SUNSCREEN 30SS30 100 towelettes 6 ( 2.72 )SALCON® Silicone Spray is specially formulatedto reduce friction on SALCOR or naturalrubber products. Reduces surface creepage onrubber gloves and sleeves. Forms an oxygenbarrier which helps reduce corona cutting andweather checking on rubber equipment. Mayalso be used to spray spark plugs and batteryterminals in damp weather to assist in starting.NEWSUNSCREEN 30 is a non-oily sunscreen thatdoes the job for at least four hours. Safe forleather and rubber gloves, leaves no residue-noslippery hands. Large convenient towelettes.X-14SALISBURY Accessories. www.wh<strong>salisbury</strong>.com


North Safety Products2000 Plainfield Pike Cranston, RI 02921 ph:(800)430-4110 fax:(800)572-6364 www.northsafety.comNorth Safety Products Ltd.10550 Parkway Blvd. Anjou (Quebec) H1J 2K4 ph:(514)351-7233 fax:(514)355-7233 1-888-212-7233 www.northsafety.caNorth Safety Products B.V.Noordmonsterweg 1 4332 SC Middelburg The Netherlands ph: +31 (0) 118 656400 fax: + 31 (0) 118 627535 www.northsafety.nlHEAD PROTECTIONHardhatsBumpcapsWinter LinersEYE & FACE PROTECTIONSafety GlassesGogglesFaceshieldsHEARING PROTECTIONDisposable andReusable EarplugsEarmuffsRESPIRATORY PROTECTIONAir-PurifyingAirlineSCBATRAFFIC SAFETY PRODUCTSVests/ClothingConesBarricade TapeSignsCONTROLLED ENVIRONMENTCleanroom GlovesDrybox GlovesFinger CotsELECTRICAL SAFETY PRODUCTSElectrical GlovesJumper CablesPower Line HoseHAND PROTECTIONGeneral PurposeChemical ResistantFIRST AID PRODUCTSKits/Cabinets/RefillsBBP/CPR ProductsDermatologicalsEyewash StationsSAFETY SIGNSOSHA/CSA/Photo-luminescentPipe MarkersNumerals/Letters/Barricade TapeLOCKOUTS/TAGOUTSValve Lockouts and TagsElectrical Lockouts and TagsPROTECTIVE CLOTHINGGeneral/Fire RetardantRainwear/Chemical SuitsSleeves/ApronsFALL PROTECTIONBelts/Harnesses/LanyardsRetractable LifelinesConfined Space SystemsEngineered SystemsPROTECTIVE FOOTWEARIndustrial/ConstructionChemical andSlip ResistantCONSUMER PRODUCTSPoint of Purchase PackagingNorcross Safety Products1136 Second Street Rock Island, IL 61201 ph:(800)777-9021 fax:(309)786-6923 (800)267-6809RUBBER PROTECTIVE FOOTWEARRanger Mining & Heavy IndustrialServus General Industrial & Outdoor WorkDIPPED NEOPRENE PROTECTIVEFOOTWEARServus Processing and PetrochemicalCOLD WEATHER PAC BOOTSServus Steel Toe PacsRanger Outdoor PacsMOLDED PROTECTIVE FOOTWEARServus Processing Petrochemical and HazMatServus General Industrial & Outdoor WorkSERVICE SLIP RESISTANT FOOTWEAR ACCESSORIESInsolesInsulating LinersRepair KitsTotal Fire Group#1 Innovation Court Dayton, OH 45414 ph:(800)688-6148 fax:(937)264-2677 www.totalfiregroup.comMORNING PRIDE® PROTECTIVE CLOTHING,HELMETS, GLOVES, HOODS AND AUXILIARIESRANGER FIREFIGHTER FOOTWEARShoe FitCombat LBSERVUS® FIREFIGHTER FOOTWEARFighting Weight BootUnishield Technology DesignProtekshin Shock Absorbing SystemAccu Fit SizingWARRINGTON PRO® FIREFIGHTER FOOTWEARMetro Style Leather Firefighting BootsStation ShoesNORTH FIRE SERVICE PRODUCTSHeat Stress Rehab PacksKevlar Knit GlovesSafety GogglesSafety Spectacles DeciGuard AB® Earplugs with Microban®Bump CapsHarnessesTripodsWinchesSelf-Retracting LifelinesTechnical Rescue SystemsSALISBURY FIRE SERVICE PRODUCTSHot Switch SticksHot Clamp SticksRubber Electrical Insulating GlovesLeather ProtectorsStorage Bags


Our WarrantySalisbury Line Equipment is warranted to be freefrom defects in materials and workmanship, and tomeet the requirements of current ASTM specificationsat time of shipment. Our only obligation willbe, at our option, to replace any portion provingdefective or to refund the purchase price thereof.The buyer assumes all other risk, if any, such asthe risk of any direct, indirect or consequential lossor damage arising out of the use of, or inability touse, these products. This warranty is in lieu of thewarranties of merchantability, fitness for particularpurpose and all other warranties, expressed orimplied, and may not be varied or extended exceptin writing by an authorized official of W.H.Salisbury & Co.ISO 9001:2000 RegisteredSALISBURYSetting industry standards since 1855.W.H. SALISBURY & CO.7520 North Long AvenueSkokie IL 60077-3226 USAtoll free ph. 877.406.4501toll free fax 866.824.4922847.679.6700wh<strong>salisbury</strong>.com