Technical Data<br />

Transmitter FMU 86X<br />

Enclosure Field, NEMA 4X (IP 65), corrosion-resistant reinforced plastic with<br />

nine punch-out conduit entries. Optional panel mount (144 x 144 mm)<br />

or rack mount (19”, 21 HP); both include keypad and display.<br />

Display 4-1/2 digit LCD with vertical and horizontal matrix position display<br />

and bar graph (%). Optional backlit matrix display.<br />

Communication Plug-in options supporting INTENSOR or HART serial communication<br />

via the 4 to 20 mA loop or RS 485 interface (DMS ready)<br />

Sensor Input One or two (FMU 862 only) sensor channels of any combination<br />

Weight Field mounted, 5.7 lbs (2.6 kg). Panel, 2.2 lbs (1 kg). Rack, 2.8 lbs<br />

(1.3 kg).<br />

Electrical Classification General purpose<br />

Resolution 0.03” (1 mm) or 0.1% of measuring span (which ever is greater)<br />

Power Input 90 to 146 VAC, 50/60 Hz; 180 to 276 VAC, 50/60 Hz; 20 to 30 VDC<br />

EMI / RFI Effects 1% for maximum measuring span at 10 V/m (10 kHz to 1 GHz) to<br />

NAMUR, IEC 801-3<br />

Overfill/Underfill Input Support connections to external voltage free make-or-break contacts<br />

or PNP switches<br />

Power Consumption 15 VA maximum<br />

Operating Temperature -4°F to + 140°F (-20° to +60°C)<br />

Storage Temperature -24°F to + 176°F (-40° to + 80°C)<br />

Humidity 95% average annual humidity<br />

Drift Temperature, negligible; load, negligible<br />

Shock Resistance 2g (10 to 55 Hz) and 15g for 11 ms per DIN40 040, type W<br />

Relay Outputs 3 or 5 SPDT, 4A at 250 VAC programmable relays including<br />

fault indication, limit switches, totalizer driver (FMU 861 and 862 only),<br />

sampler activation (FMU 861 and 862 only)<br />

Analog Outputs 1 or 2 (FMU 862 only) isolated 4 to 20 mA @ 600 Ohms maximum.<br />

Output current limit, 24 mADC<br />

Indicators Yellow LED for each relay, lighting during de-energized state; green<br />

LED indicating proper operation<br />

Totalizer Optional 6-digit (non-resettable, FMU 861 and 862 only)<br />

Keypad Interface 6 tactile feedback keys to access operator matrix. V and H keys for<br />

vertical and horizontal movement. Other keys for data entry.<br />

Recommended Cable 18-AWG, two-conductor with maximum 25 Ohms and 60 nF per<br />

conductor, maximum 1000 feet<br />

Optional Accessories FAU 40 sensor positioner, all-weather cover, pipe-mount kit.<br />

Dimensions Refer to diagram below<br />

Mounting<br />

Hole (4)<br />

7.9"<br />

(Mtg.)<br />

Knock-out<br />

Conduit<br />

Entry (9)<br />

9<br />

PROSONIC<br />

FMU 860<br />

10.85"<br />

(Mtg.)<br />

11.5"<br />

1<br />

2<br />

3<br />

4<br />

5<br />

V H<br />

E<br />

10"<br />

4.17"