STATIONARYINSTRUMENTSSENSOR TRANSMITTERSLocated in Irvine, California, <strong>International</strong> <strong>Sensor</strong><strong>Technology</strong> (IST) manufactures both the sensors and theinstrumentation used to detect over 150 different toxicand combustible gases for area air quality and safety applications.Since 1972, IST instruments have served alarge and diverse customer base, with users including refineries,chemical plants, semiconductor facilities,hospitals, food and beverage companies, and many others.In fact, our equipment was even chosen by NASA foruse in the Space Shuttle program.IST offers a complete line of instrumentation, includingportables, single and multi-point stationary instruments,stand-alone sensor transmitters, and computerized gasmonitoring systems. Besides offering a complete line ofinstrumentation, IST also offers the most comprehensivechoice of sensor technologies available today, including:• IST’s patented Solid-State <strong>Sensor</strong>• Infrared <strong>Sensor</strong> (IR)*• Catalytic Bead <strong>Sensor</strong>• Electrochemical <strong>Sensor</strong>• Photoionization DetectorWith this vast array of sensor and instrumentationchoices, IST has the right solution for your gas monitoringapplication.*Patent PendingSTANDARD TRANSMITTERMODEL SM95The Model SM95 sensor transmitter is housed in an explosion-proofcasing rated for Class 1, Div. 1, GroupsB,C,D (UL & CSA approved). It operates on 14-24 VDCpower and provides a linear 4-20 mA output proportionalto the gas concentration. The SM95 can operate as astand-alone instrument or can be used in conjunctionwith any of IST’s complete line of control units which displaythe readings and provide alarm relays. When usedwith any of IST’s MP Series of control units, automatedcalibration is provided, enabling calibration without theneed to adjust potentiometers. The SM95 can beequipped with Solid State, Electrochemical, CatalyticBead, or Infrared sensors.INTELLIGENT TRANSMITTERMODEL 4-20IQThe Model 4-20IQ is a microprocessor based, intelligentsensor transmitter which features a digital display of thegas concentration. Operating on 14-24 VDC power, it alsoprovides a linear 4-20 mA output and, like the SM95, ishoused in an explosion proof casing rated for Class 1, Div.1, Groups B,C,D (UL & CSA approved). It can operate asa stand-alone instrument or can be used with any ISTcontroller, which display the readings and provide alarmrelays.The 4-20IQ comes equipped with a non-intrusive automatedcalibration feature which allows the unit to becalibrated without adjusting any potentiometers. Simplyapply calibration gas and the 4-20IQ will automaticallymake the necessary calibration adjustments. Operatingthe 4-20IQ is accomplished by using a magnetic wandto activate magnetic switches located on the front panel.Thus, all functions can be performed without removingany covers, meaning there is no need to declassifyareas being monitored. Like the SM95, the 4-20IQcan be equipped with Solid State, Catalytic Bead,Electrochemical, or Infrared sensors.


STATIONARYINSTRUMENTSCONTROLLERSSINGLE CHANNEL WALL MOUNTEDMODEL LC100The LC100 is a single channel, wall mounted controlunit which is housed in a weatherproof enclosure. It providesa digital display of the gas concentration, 2 alarmrelays and a fault relay with corresponding LED’s, and abuilt-in alarm buzzer. Either an SM95 or 4-20IQ transmittercan be connected externally to the unit or, as anoption, a Solid State sensor can be internally mounted directlyinside the LC100 housing (this option requiressample to be pumped to the unit). A 4-20 mA output isavailable as an option.MULTI-CHANNEL WALL MOUNTEDMODEL MP202/MP204The MP202 and MP204 are wall-mounted control unitshoused in weatherproof enclosures. The MP202 is a twochannel controller which can be used for 1 or 2 sensorchannels, while the MP204 is a four channel controllerwhich can be used for up to 4 sensor channels.These microprocessor based controllers feature a digitaldisplay of gas concentration for each sensor channeland a front door keypad which enables convenient operationwithout opening the enclosure. Low, mid, and highalarm relays as well as a fault relay (with correspondingLED’s) are also provided to trigger alarm devices such aslights and horns. Optional 4-20 mA outputs are available.WALL MOUNTEDMODEL LC100WALL MOUNTEDMODEL MP204WALL MOUNTEDMODEL MP202EXPLOSION PROOFMODEL MP220EXThe MP Series units feature automated calibrationwhich enables the sensor transmitters to be calibratedwithout removing the cover or adjusting potentiometers.Simply apply gas to the sensor and the control unit willmake all the necessary adjustments. It couldn’t be easier!MULTI-CHANNEL RACK MOUNTEDMODEL MP24The MP24 is a rack/panel mounted version of theMP202. It is a compact control unit which accepts 1 or 2sensor channels. Because of its compact design, up to 12of these control units will fit side by side into a 19" rack orpanel space, for a total of 24 sensor channels. The MP24also has a modular design which allows for easy expansionand the ability to configure the unit specifically for aparticular application. Like the MP202/MP204, the MP24can be equipped with optional 4-20 mA outputs.DUAL CHANNEL EXPLOSION PROOFMODEL MP220EXThe MP220EX is a two-channel, explosion proof, wallmounted, control unit rated for use in Class 1, Div. 1,Groups C, & D (B optional) hazardous areas. Operationvia magnetic wand allows the unit to be operated withoutopening the cover, thereby ensuring that hazardousareas do not require declassification. 4-20 mA outputs areavailable as an option.RACK/PANEL MOUNTEDMODEL MP24FOR GAS CABINETSSINGLE CHANNEL RACK MOUNTEDMODEL MP100The MP100 is a single channel rack mounted controllerdesigned for installation into semiconductor gas cabinetsfor detection of Hydrogen. Utilizing a long life SolidState sensor, it can be configured to detect hydrogen ineither PPM or %LEL concentrations. The Solid State sensoroffers a 10+ year life expectancy and comes with a 3year warranty, thus offering significant improvementsover electrochemical sensors which have commonlybeen used in these applications. The unit comes standardwith a digital display, 2 alarm relays and a 4-20 mAoutput. Like the other MP Series controllers, the MP100also features automated calibration. It operates on 24VDC, and can optionally be configured to operate on 110or 220 VAC.


COMPUTERIZEDSYSTEMSPORTABLESAll of IST’s portable instruments are designed to operateon either alkaline or nicad batteries, or the ACadapter/charger which is included with every unit. TheAC adapter/charger will charge nicad batteries, whilebypassing alkaline batteries, and allows portable units tobe powered on at all times and ready for use for maximumreliability.REMOTE-LINK SYSTEMThe Remote-Link System is a state-of-the-art, computer-controlledgas monitoring system which allowssensors to communicate with the Remote-Link Computerover an AC power line, providing a data highway whicheliminates the individual sensor wiring associated withconventional monitoring systems. Since 1989, theRemote-Link System has provided customers worldwidewith the most advanced monitoring system available,with the capabilities, features, and field proven reliabilityfound on no other system. The Remote-Link’s powerfulmonitoring software includes such features as dataarchiving and reporting, curve plotting, alarm processing,and fault monitoring. Additionally, computergraphics display your plant and the locations of all sensorswithin your plant. By using the mouse button topoint and click on a sensor, you can view it’s currentreading and alarm status. A separate readings screen letsyou view the readings of all sensors simultaneously.When an alarm occurs, audible and visual indications areprovided and the graphics display will pinpoint thealarm area. In addition, programmable alarm relays areactivated to trip horns, lights, etc.The Remote-Link Systemcan accommodate hundreds,even thousands, ofsensors, yet is still an economicalchoice for systemswith as few as 8 sensors.The modular design of thesystem enables additionalsensors to be added withease at a low incrementalcost, allowing you to expandthe system accordingto your needs. Computerassisted calibration takesthe hassle out of calibration.Zero every sensor inthe system with the pressof a button! Then, simplyapply gas to each sensorand the let the computer dothe rest. Calibration justdoesn’t get any easier!TLV PANTHERThe TLV Panther is an Industrial PrecisionPhotoionization Detector (PID). Offering fast responseand high sensitivity, photoionization is the preferredmethod for detection of Volatile Organic Compounds(VOC’s), and the TLV Panther is the first PID unit of itskind to utilize Precise Response Curves for the detectionof individual gases, including ammonia, benzene, andhydrazine, to name a few. No correction factors are used.The actual response curves for 30 gases are preprogrammedinto each unit. The TLV Panther’s automatedcalibration feature allows you to calibrate all of thesegases by calibrating just one gas, making calibration extremelysimple. For maximum precision, you also havethe option to individually calibrate gases of interest.The TLV Panther also provides you with the ability ofadding up to 3 additional sensors, either electrochemicalor infrared, for more selective detection of individualgases of interest. This allows the TLV Panther to handle awide variety of applications. The TLV Panther also comesstandard with a large, backlit LCD display, built-in samplingpump, and audible and visual alarms. The optionaldata logging feature lets you store months worth of datawhich can be downloaded to a computer or printed outvia the built-in RS-232 interface. The unit is powered via6 ‘D’ size batteries (alkaline or nicad), or the ACadapter/charger.TLV FALCONLike the TLV Panther, the TLV Falcon incorporates aphotoionization detector (PID) for the detection ofVolatile Organic Compounds (VOC’s). However, becausethe TLV Falcon is a single channel unit, it is much morecompact. The TLV Falcon comes standard with a digital


display, built-in sample pump, and audible and visualalarms. It operates on 4 ‘C’ size alkaline or nicad cadmiumbatteries, or the AC adapter/charger. The unit comesstandard with 3 ranges which are selectable via a switchon the front panel. While the unit comes standardcalibrated to isobutylene, calibration to other gases isalso available.concentration, built-in sample pump, and audible andvisual alarms. It operates on 4 ‘C’ size alkaline or nicad batteries,or the AC adapter/charger. The Eagle comesstandard with 3 ranges which are selectable via a switch onthe front panel.100 GAS PORTABLE – MODEL IQ-1000IST’s Model IQ-1000 is the most unique and versatileportable gas detector on the market today. Using IST’sMega-Gas sensor, this remarkable unit can detect OVER100 toxic and combustible gases. Three alarm setpointsare provided for each gas, and audible as well as visualindicators alert you if any of these alarm limits have beenexceeded. A “Gas Search” feature allows you to scan anarea for any of these hazardous gases.Besides the Mega-Gas sensor, the IQ-1000 also acceptselectrochemical, catalytic bead, solid state, or infraredsensors. A total of four sensors of varying types can beused, giving the IQ-1000 the flexibility to meet a widerange of applications. A large, 8 line, 40 character per linedisplay allows you to simultaneously view the readingsof all 4 sensors.SINGLE GAS PORTABLEMODEL IQ-250IST’s Model IQ-250 is a single gas portable instrumentwhich can be equipped with either a solid state, or electrochemicalsensor. Any one of over 150 toxic andcombustible gases can be chosen. A digital display indicatesthe gas concentration, and an alarm buzzer andalarm LED’s alert you to the presence of hazardous levels.The IQ-250 does not incorporate a sample pump, andsamples by diffusion only. User adjustable setpoints areprovided for low, mid, and high alarm levels. The unitoperates on 4 ‘AA’ size alkaline or nicad batteries, or theAC adapter/charger. The IQ-250 weighs approximately22 ounces, including batteries.The standard unit includes a built-in sample pump,sample wand, and carrying case. Calibration is simpleand automated, and optional datalogging enables storageof months of data. An RS-232 port provides interface to acomputer or printer. Power is provided by six ‘D’ size alkalineor nicad batteries, or the AC adapter/charger. TheIQ 1000 weighs approximately 6 lbs., including batteries.IQ-350 EAGLEThe IQ-350 Eagle is a portable instrument which comesequipped with an Infrared (IR) sensor for detection ofCarbon Dioxide (CO 2 ), Carbon Monoxide (CO), orHydrocarbons (HC’s). The unit can be optionallyequipped with an additional sensor for the detection ofOxygen. The unit provides a digital display of gasSINGLE GAS PORTABLE WITHSAMPLE PUMP – MODEL IQ-350IST’s Model IQ-350 is a single gas portable instrumentwhich provides all of the features of the IQ-250 and inaddition comes standard with a built-in sampling pump.Like the IQ-250, it can be equipped with either a solidstate or electrochemical sensor and can be configured todetect any one of over 150 toxic and combustible gases.The unit operates 20 hours on 4 ‘C’ size alkaline or nicadbatteries, or the AC adapter/charger. The IQ-350 weighsapproximately 30 ounces, including batteries.


PORTABLES4 GAS, CONFINEDSPACE ENTRYPORTABLEMODEL IQ-200IST’s Model IQ-200 requiresjust two sensors for confinedspace entry applications, asingle solid state sensor forCO, H 2 S, and combustiblegases, and an electrochemicalsensor for oxygen. This makes theIQ-200 much more affordable than comparable confinedspace entry portables. Additionally, both the solid stateand oxygen sensors used in the IQ-200 are long-life sensors.Typical life expectancy is 5 years for the O 2 sensorand over 10 years for the solid state sensor. This results ina tremendous savings in long term operating costs associatedwith sensor replacement.The IQ-200 has an audible alarm buzzer, and alarmLED’s indicate low, mid, and high alarm levels for thesolid state sensor, and low and high alarms for the O 2 sensor.The IQ-200 does not incorporate a sample pump andsamples by diffusion only. It is small and lightweight,weighing just 22 ounces, including batteries. It operateson 4 size ‘AA’ alkaline or nicad batteries, or the ACadapter/charger. Carrying case is included.GAS SENSORSIST offers 5 different types of sensors: SolidState, Infrared, Photoionization, Catalytic Bead, andElectrochemical. This gives you the flexibility to choosethe best sensor(s) for your particular application. A briefdescription of each sensor type follows:SOLID STATESolid State sensors are made of a heated metal oxidematerial which temporarily changes resistance in thepresence of gas. Solid State sensors are available for thedetection of over 150 different toxic and combustiblegases, in ranges from low ppm %LEL. A list of gases andranges appears on the back of this brochure. Solid Statesensors come with a 3 year warranty, and have a life expectancyin excess of 10 years.INFRARED SENSOR (IR)Infrared (IR) sensors detect gases that absorb light inthe infrared spectrum. <strong>Sensor</strong>s for carbon dioxide (CO 2 ),carbon monoxide, and hydrocarbons (such as Methane,etc.) are currently available. IR sensors offer good selectivityand good lifetimes. Ranges for CO 2 are availablefrom ppm to 20% by volume, with the lower ranges offeringbetter resolution. CO is available in % volumeranges, and hydrocarbon ranges are available from %LELup to 100% by volume, depending upon the gas.PHOTOIONIZATION DETECTOR (PID)Photoionization detectors (PID) operate by ionizing thetarget gas with ultra-violet radiation, and then collectingthe ions across a high voltage plate which produces anelectrical signal proportional to the gas present. PID’soffer fast response for many Volatile Organic Compounds(VOC’s), including, among others, benzene, vinyl chloride,phosphine, and hexane.ELECTROCHEMICALElectrochemical sensors operate by producing a chemicalreaction with the gas of interest. <strong>Sensor</strong>s are availablefor certain toxic gases in ppm ranges, including NH 3 , CO,Cl 2 , H 2 , HCl, HCN, H 2 S, NO, NO 2 , O 2 , O 3 , and SO 2 . Forsome of these gases, electrochemical sensors can offer afairly high degree of selectivity. Electrochemical sensorshave a life expectancy of 1 to 2 years and come with a 1year warranty.CATALYTIC BEADCatalytic Bead sensors operate by burning combustiblegases, raising the temperature of the sensor. This temperaturerise changes the resistance of the sensor andproduces a signal proportional to the gas concentration.They detect combustible gases in higher concentrations(above 1000 ppm) only. They are not selective and will respondto a wide range of combustible gases. However,since they only detect higher gas concentrations, they arenot prone to interference from many toxic gases. CatalyticBead sensors have a life expectancy of 2 years and comewith a 1 year warranty.1 2 3 4 51 IST’S PATENTED SOLID STATE SENSOR2 INFRARED SENSOR (IR)3 CATALYTIC BEAD SENSOR4 ELECTROCHEMICAL SENSOR5 PHOTOIONIZATION DETECTOR (PID)To help you select the most appropriate sensorfor your application, contact IST toreceive additional assistance and a copy ofIST’s <strong>Sensor</strong> Selection Guide.


The following gases are available for detection using IST’s Solid State <strong>Sensor</strong>s. The full-scale ranges listed are standard rangesavailable. For toxic gas monitoring, ranges are typically chosen which are higher than the TLV so that hazardous levels will bedetected (TLV is defined as a SAFE level). For combustible gases, the typical range is 0-100 % LEL. Other ranges can also beprovided—please contact IST for information. The following information is valid as of 11/97.SOLID STATE SENSOR GAS LISTGASFULL-SCALE RANGESAcetic Acid100, 200 ppmAcetone100, 200, 500, 1000, 5000 ppm, % LELAcetonitrile100 ppmAcetylene50 ppm, % LEL, 3% by VolumeAcrolein (Acrylaldehyde) 50 ppmAcrylic Acid100 ppmAcrylonitrile50, 60, 80, 100, 200, 500 ppm, % LELAllyl Alcohol% LELAllyl Chloride200 ppmAmmonia 50, 70, 75, 100, 150, 200, 300, 400, 500,1000, 2000, 2500, 4000, 5000 ppm, 1%,2%, 10% by Vol., 10%, 25%, 100% LELAnisole100 ppmArsenic Pentafluoride 5 ppmArsine1, 10 ppmBenzene50, 75, 100, 1000 ppm, % LELBiphenyl50%, 100% LELBoron Trichloride500 ppmBoron Trifluoride500 ppmBromine20 ppmButadiene50, 100, 3000 ppm, % LELButane400, 1000 ppm, 100%, 200% LELButanol1000 ppm, 100% LELButene100% LELButyl Acetate100 ppm, % LELCarbon Disulfide50, 60, 100 ppm, 5% by VolumeCarbon Monoxide 50, 100, 150, 200, 250, 300, 500, 1000,3000, 5000 ppm, 3%, 5% by Volume, % LELCarbon Tetrachloride 50, 100, 10000 ppmCellosolve Acetate100 ppmChlorine10, 20, 50, 100, 200 ppmChlorine Dioxide10, 20 ppmChlorobutadiene100% LELChloroethanol200 ppmChloroform50, 100, 200 ppmChlorotrifluoroethylene 100% LELCumene100% LELCyanogen Chloride20 ppmCyclohexane100 ppm, 100% LELCyclopentane50 ppmDeuterium50%, 100% LELDiborane10, 50 ppmDibromoethane50 ppmDibutylamine100% LELDichlorobutene1% by VolumeDichloroethane (EDC) 50, 100 ppm, % LELDichlorofluoroethane 100, 1000 ppmDichloropentadiene50 ppmDichlorosilane50, 100 ppmDiesel Fuel50 ppm, 100% LELDiethyl Benzene100% LELDiethyl Sulfide10 ppmDifluorochloroethane 100% LELDifluoroethane (152A) 100% LELDimethyl Ether100% LELDimethylamine (DMA) 30, 50 ppmEpichlorohydrin50, 100, 500, 1000 ppmEthane1000 ppmEthanol200, 1000, 2000 ppm, % LELEthyl Acetate200, 1000 ppm, % LELEthyl Benzene200 ppm, % LELEthyl Chloride100 ppm, % LELEthyl Chlorocarbonate 1% by VolumeEthyl Ether100, 800, 1000 ppm, % LELEthylene100, 1000, 1200 ppm, % LELEthylene Oxide 5, 10, 20, 30, 50, 75, 100, 150, 200, 300,1000, 1500, 2000, 3000 ppm, % LELFluorine20, 100 ppmFormaldehyde15, 50, 100, 500, 1000 ppmFreon-111000, 2000, 5000 ppmFreon-121000, 2000, 3000 ppmFreon-22100, 200, 500, 1000, 2000 ppmFreon-113100, 200, 500, 1000, 2000 ppm, 1% by Vol.Freon-1141000, 2000, 20000 ppmFreon-1231000 ppmFuel Oil or Kerosene100% LELGasoline100, 1000, 2000, 20000 ppm, % LELGermane10, 50 ppmHeptane1000 ppm, % LELGASFULL-SCALE RANGESHexane50, 100, 200, 2000, 2500, 3000 ppm, % LELHexene% LELHydrazine5, 10, 20, 100, 1000 ppm, 1% by VolumeHydrogen50, 100, 200, 500, 1000, 2000, 5000 ppm,3%, 5% by Vol., 2% to 100% LELHydrogen Bromide50 ppmHydrogen Chloride50, 100, 200, 400, 500, 1000 ppmHydrogen Cyanide20, 30, 50, 100, 200, 1000, 10000 ppmHydrogen Fluoride20, 50, 100, 200 ppmHydrogen Sulfide5, 10, 20, 30, 50, 100, 300, 1000 ppm,% LELIsobutane1000, 3000 ppm, % LELIsobutylene% LELIsopentane1000 ppmIsoprene% LELIsopropanol200, 400, 500, 1000 ppm, % LELJP41000 ppm, % LELJP51000, 5000 ppm, % LELMethane100, 200, 1000, 1500, 2000, 5000 ppm,1%, 2% by Volume, 100%, 200% LELMethanol200, 300, 400, 500, 1000, 2000, 5000 ppm,15%, 30%, 100% LELMethyl Acetate30 ppmMethyl Acrylate60 ppmMethyl Bromide 20, 50, 60, 100, 500, 1000, 10000,40,000 ppmMethyl Butanol% LELMethyl Cellosolve% LELMethyl Chloride100, 200, 300, 2000, 10000 ppm, % LELMethyl Ethyl Ketone100, 500, 1000, 4000 ppm, 100% LELMethyl Hydrazine5 ppmMethyl Isobutyl Ketone 200, 500, 2000 ppm, 50%, 100% LELMethyl Mercaptan30 ppmMethyl Methacrylate 100 ppm, % LELMethyl-Tert Butyl Ether 100% LELMethylene Chloride 20, 100, 200, 300, 400, 500, 600, 1000,2000, 3000, 5000 ppm, % LELMineral Spirits200, 3000 ppm, % LELMonochlorobenzene100% LELMonoethylamine30, 100, 1000 ppmMorpholine500 ppmNaptha1000 ppm, 100% LELNatural Gas1000, 2000 ppm, 2%, 4% by Volume, % LELNitric Oxide20, 50 ppmNitrogen Dioxide20, 50, 100 ppmNitrogen Trifluoride50, 500, 1000 ppmNonane2000 ppmPentane200, 1000 ppm, % LELPerchloroethylene200, 1000, 2000, 20000 ppmPhenol100 ppmPhosgene50 ppmPhosphine3, 5, 10, 20, 30, 50 ppmPhosphorus Oxychloride 200 ppmPicoline% LELPropane100, 1000 ppm, 100% LELPropylene100, 200, 1000, 5000 ppm, %LELPropylene Oxide100 ppm, % LELSilane10, 20, 50 ppmSilicon Tetrachloride1000 ppmSilicon Tetrafluoride1000 ppmStyrene200, 300 ppm, % LELSulfur Dioxide50, 100 ppmTetrahydrofuran200, 300, 1000 ppm, % LELTetraline100 ppmToluene50, 100, 200, 500, 2000, 5000 ppm, % LELToluene Diisocyanate 15 ppmTrichloroethane50, 100, 500, 1000 ppm, 1% by VolumeTrichloroethylene50, 100, 200, 300, 500, 1000, 2000 ppm, %LELTriethylamine (TEA)100 ppmTrifluoroethanol25, 100 ppmTrimethylamine (TMA) 50 ppmTungsten Hexafluoride 50 ppmTurpentine% LELVinyl Acetate1000 ppm, % LELVinyl Chloride 20, 50, 100, 200, 400, 500, 1000, 4000,10000 ppm, 10%, 100% LELVinylidene Chloride50 ppmXylene100, 200, 300, 1000 ppm, 1% by Volume


For further information on any product,please contact IST or our authorized representative.Represented By:INTERNATIONALSENSOR TECHNOLOGYThe Leader In Gas Detection Since 19723 Whatney • Irvine, California 92618-2824 • Telephone 949-452-9000 • FAX 949-452-9009e-mail: ist@intlsensor.com • website: www.intlsensor.com