120 USG (450 Liter) Tank <strong>Installation</strong> (continued)<br />
Fitting the thermometer and thermometer sensor<br />
(if supplied) and covers<br />
1. Smooth out the insulation jacket by tapping the jacket<br />
evenly against the tank.<br />
2. Route thermometer capillary tube through the<br />
front cover hole and insulation jacket, then snap the<br />
thermometer in place.<br />
3. Insert the thermometer probe under the clip.<br />
4. Install the front cleanout cover and the front lower<br />
seam cover.<br />
5. Install the upper front seam cover.<br />
6. Install the back seam cover.<br />
7. Install the top insulation and press down the edges<br />
as shown.<br />
8. Install the top lid and press the logo A into the lid.<br />
Note: Seal the hole in the seam cover below the<br />
thermometer with a cover.<br />
5608 487 v1.2 Vitocell <strong>100</strong>-V <strong>Installation</strong> <strong>Instructions</strong> Set-up and Connections<br />
13