11.07.2015 Views

STATIM G4 cassette autoclave - Scican.uk.com

STATIM G4 cassette autoclave - Scican.uk.com

STATIM G4 cassette autoclave - Scican.uk.com

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>STATIM</strong> technology defined – what makes <strong>STATIM</strong> different?Immediate Steam GenerationUnlike conventional <strong>autoclave</strong>s that need to heat an entirereservoir of water, <strong>STATIM</strong> uses only a small, specific amountof water required for each cycle. Water is introduced intoa heating device referred to as a ‘steam generator’, rapidlyheated and converted to steam in mere seconds.Air RemovalUsing PPPD technology and our patented steam injectionprocess – air is automatically forced out of the sterilizationchamber.Cassette SystemThe thin stainless steel walls of <strong>STATIM</strong>’s fully-removable<strong>cassette</strong>, (or sterilization chamber) allow for rapid heatingand cooling of the chamber. As a result, <strong>STATIM</strong> meetsthe conditions for sterilization and drying in a fraction ofthe time required by a conventional <strong>autoclave</strong>.EN13060FullyCompliantFully Satisfies EN13060 forInstrument Sterilization<strong>STATIM</strong> continues to meet all EN13060 requirements,powered by advanced microprocessor controlled cycleswhich deliver validated sterilization at speeds up to5X faster than most conventional chambered <strong>autoclave</strong>s.Drying TechnologyThe <strong>STATIM</strong> 2000 and 5000 have each been designedto provide you with a <strong>com</strong>plete solution: rapid sterilizationbalanced by rapid drying. Introducing <strong>STATIM</strong> Dri-Tecdrying technology.Dri-Tec C – Convection HeatDrying TechnologyThe <strong>STATIM</strong> 2000 uses convection heat to dry instrumentsby utilizing the remaining heat in the system after thesterilization phase. Heat is captured and released intothe <strong>cassette</strong>, drying wrapped instrument loads in as littleas 10 minutes.Dri-Tec R – Radiant HeatDrying TechnologyThe <strong>STATIM</strong> 5000 uses heat generated by the sterilizationcycle which is ‘absorbed’ by unique drying plates locatedin the sterilization chamber. Heat is transferred from thedrying plates directly to instruments resulting in accelerated,full load drying in as little as 15 minutes.


Introducing the new, 4th generation <strong>STATIM</strong> by SciCan.>> Fast<strong>STATIM</strong>’s unmatched speed and dependabilityhave made <strong>STATIM</strong> the world’s best-selling<strong>autoclave</strong>. And its patented gentle technologyhas also made <strong>STATIM</strong> the world’s favourite.>> ForwardThe <strong>STATIM</strong> <strong>G4</strong> will offer you a level of interactivitynever seen before. The <strong>STATIM</strong> <strong>G4</strong>, throughits LCD touch screen control and Statim Livenetworking capability, has been designed toprovide you with unprecedented ease of useand puts the user in total control.


TouchA high-resolution, 65K color touchscreen offers a vivid displayof messages, current cycle information and customizableicons all with extraordinary clarity. Fully adjustable contrastlevels let you optimize the screen to the lighting in yoursteri-centre, and its 2.5-inch by 3-inch dimensions alloweasy viewing of downloadable learning modules.ConnectThere’s nothing like <strong>STATIM</strong> Live, the networked portalthrough which you can view not only your <strong>STATIM</strong>’s currentoperations in real time, it also gives you access to cyclehistory, printing and validation information and sterilizationrecords searchable by multiple fields. Capable of sendingemails with cycle information errors directly to your dealer,your <strong>STATIM</strong> <strong>G4</strong> will let qualified technicians know whenservice is imminent, can perform software upgrades andeven some remote troubleshooting.ProtectPatient safety relies on attention to detail. The <strong>STATIM</strong> <strong>G4</strong>supports verifiable processes that are PIN protected withuser-defined IDs so that staff members can be required toauthorize a cycle. This encourages extra attention to processand creates a safer environment for both staff and patients.CollectAn undocumented sterilization cycle might as well not havebeen done. With each cycle, information must be stored toprotect your office and your patient. The integrated SciCanDataLogger stores all cycle information for the lifetime of theunit, a 2.0 USB port allows for the manual retrieval of cyclehistory, the 10/100Base-T Ethernet connection puts yourPC in direct contact with your <strong>STATIM</strong> and the RS232 serialprinter port allows you to connect with an external printer.Access your <strong>STATIM</strong> via yourPC through Statim Live65k colour touchscreen providesa wealth of informationThe <strong>G4</strong> is capable of <strong>com</strong>municatingdirectly with service personnelRe<strong>com</strong>mended essential STATIS ®instrument systemLoose instrumentsWrapped instruments


How <strong>STATIM</strong> WorksEase of Operation<strong>STATIM</strong> 2000/5000 Steam InjectionSingle Use Water System


Sterilization Cycle Time ComparisonTemperature<strong>STATIM</strong> 2000Conventional <strong>autoclave</strong>6 20 30 40Minutes50Small Steam Generatorfor Instant SteamUltra Fast Condition Phase<strong>STATIM</strong> 2000<strong>STATIM</strong> 5000Drying TechnologyDry Load


www.scican.<strong>com</strong>SD-364-EN 3/2011<strong>STATIM</strong> Cassette Autoclave and STATIS are registered trademarks of SciCan Ltd. Dri-Tec C , Dri-Tec R , logo’s and Your Infection Control Specialist are trademarks of SciCan Ltd.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!