<strong>Weishaupt</strong> Monarch oil burnersSizes 1 and 31/2002 CA


Description<strong>Weishaupt</strong> Monarch oil burners are ofthe fully automatic pressure atomizingtype. Their design has been carefullyconsidered down to the smallestdetail and has been proven to besuccessful over and over again. Theymeet all the demands for safety,reliability and low cost operation.The burners are distinguished by avariety of excellent features:■ Range of application 1.75 - 19 GPH(240 - 2,645 MBH)■ Automatic sequence of operations■ Stable fan characteristics – goodcombustion results■ Air regulation on pressure side■ Air damper closed on burner shutdown■ Quiet operation■ Complete pre-wired integralswitchgear■ Hinged burner casing■ Combustion head can be pulled outwhen the burner is hinged open■ The design of the burner makesinstallation, adjustment and servicingeasyConstructionAll the components are assembled in oneunit. The motor drives the fan and the fuelpump. All the equipment used for theregulation of fuel and air is clearlyarranged and easily accessible. Theburners can be hinged to the left or right,which simplifies service work on thecombustion head, diffuser, nozzles andignition electrodes.ApplicationThe burners can be used on hot waterboilers, steam boilers, air heaters and forvarious heating processes. The burnersare used in particular on modern, highefficient boilers, as they are capable ofovercoming high combustion chamberpressures. RL burners are preferablyused where there is a continuallychanging heat demand.FuelsLight oil #2 to Medium heavy oil #4.Viscosity:Types Monarch L and RL -< 6 cSt (6 mm 2 /s) at 68F (20°C)Type Monarch M -≤ 75 cSt (75 mm 2 /s) at 122F (50°C)RegulationOn L and M type burners, the regulationof oil and air takes place as follows:■ two stage, nozzle head with two nozzlesand a motor controlled, quicklyopening air damper.■ three stage, with three nozzles and amotor controlled, slowly opening airdamper.The RL burners control fuel and air ratioin compound. The burner can, dependingon the controller and servomotor, beeither:■ sliding two stage (20 s running time)or■ modulating (42 s running time)With sliding two stage regulation, the lowand high fire positions are fixed within theburner operating range. The burnerslides to one position or the other,depending on the appliance demand,and there are no rapid changes of fuelthroughput.By utilizing a suitable controller into thecontrol panel, the burner can beoperated in modulating mode.Modulating burners operate at any pointwithin the capacity range, depending onthe heat demand.On sliding two stage burners andmodulating burners, the slow capacityalteration ensures a particularly goodmatching to the demand of the heatingappliance.Flame safeguardThe burner flame safeguard automaticallysequences the operations and monitorsthe flame optically via the flame sensor.The flame safeguard is mounted on theburner on all standard L and M burners,but can be supplied loose if requested.Together with the control panel, eachburner forms one complete unit. On theRL burner, the flame safeguard issupplied loose for installation in thecontrol panel.There is no interference with radio andtelevision reception, as radio interferencecreated during ignition is below thepermitted limits specified by the relevantEMC standards and regulations.Quiet operation<strong>Weishaupt</strong> burners operate quietly. All airhandling burner parts have beenaerodynamically designed, the fuel / airmixing noise is reduced to a minimumand rotors and fan wheels aredynamically balanced. For installationswhere special emphasis is placed onburners with low noise levels, soundabsorbers, which considerably reduceburner noise, are available as an option.Oil temperature regulationMedium/ heavy oil burners are equippedwith oil preheater. The oil is quicklyheated to the required atomizingtemperature, due to the large heatexchanger surface combined with arelatively small oil volume. Fast andevenly heat distribution prevents localoverheating and carbonization of the oil.Heated nozzle head and nozzlerecirculation system on medium/heavy oil burnersAll medium/ heavy oil burners are fittedwith a heated nozzle head system. Afterthe oil temperature in the nozzle head hasbeen reached, the burner is released foroperation by a thermostat. Duringprepurge, heated oil flows through thenozzle head and oil line system. Thisensures that evenly heated oil is availablefor good combustion.2


Scope of deliveryScope of delivery L1Z-B L3Z-A L1T-B M1Z-B RL3-AL3T-A M3Z-ABurner casing with integral air inlet, hinged flange, hinge interlock switch, flange gasket, ● ● ● ● ●<strong>Weishaupt</strong> burner motor, fan, pump, oil hoses, nozzle assembly, combustion head, ignitiontransformer, ignition cables, ignition electrodes, fixing screws, air damper on fan pressure side.Oil solenoid valve(s) ● ● ● ● ●Additional safety valve(s) ● ● ● ● ●and oil pressure switch (on burners > 8 GPH/ 30 kg/h) – – – ● ●Nozzle(s) ● ● ● ● ●Burner flame safeguard with flame sensor– Type LAL for burners ● ● ● ● ●Terminal strip or ● ● ● ● ●Integral switchgear ● ● ● ● –Servomotor for air regulation ● ● ● ● –Servomotor for oil / air regulation with regulating cam (sliding two stage burners – – – – ●type SQM 10.15561, 20 s running time; modulating burners type SQM 10.16561,42 s running time), oil regulator, spill type nozzleOil preheater, heated nozzle head and nozzle recirculation system, – – – ● –filterParts supplied with integralswitchgear (ISG version)The integral switchgear version includesall the parts required for operation.1 stage 1 control switch with indicatinglamp1 stage 2 control switch with indicatinglamp1 contactor (motor)1 overload relay(three phase burners only)1 contactor for oil preheater on burnertype M1Z-B (2 on burner type M3Z-A)Nomenclature of burner typeR L 3 Z – A version ZMDE= Single phase ACD = Three phase ACType of regulationZM = sliding two stageCode for burner seriesZ = two stage, T = three stageSizeL = #2 light oil, M = #4 medium heavy oilR = modulating burnerMonarch L light oil burner, two stageCover4


Model overviewTypes of regulation<strong>Weishaupt</strong> Monarch oil burnersquick regulationslow (sliding) regulation#2 light oil burners#2 heavy medium oil burners #2 light oil burnerstwo stagethree stagetwo stageslidingtwo stagemodulatingL1Z-B and L3Z-AL1T-B andL3T-AM1Z-B andM3Z-ARL3-ATwo stage and three stageregulation (Z/T)Standard burner version■ Oil is released at start when solenoidvalves 1 and 2 open. The burner runsat low fire.■ High fire is reached when solenoidvalve 3 / 4 opens.■ The capacity is regulated by openingand closing solenoid valve 3 or 3and 4SV1 SV2110V 110VSV3110VSV4110V(Standard burner version)HFIFLFonoffSliding two stage and modulatingregulation (ZM)■ For burner start the oil regulator goesinto the ‘ignition’ position.■ A slow running oil / air compoundservomotor adjusts the oil quantity upto high fire. The servomotor regulatesthe burner capacity between low andhigh fire.■ The difference between sliding twostage and modulating burners is thaton the modulating version the servomotoron the burner has a runningtime of 42 s and on the sliding twostage burner a running time of 20 s.In addition a special controller shouldbe fitted into the control panel formodulating operation.55V55VPM55V55VHFLFIGNHFLFIGNononoffoffHF = High fire, IF = Med. fire,LF = Low fire, IGN = ignition positionUpper graph: sliding two stageLower graph: modulating5


Size 1 burner selectionBurner rating / combustion chamber pressureBurner type _______ L1Z-B and L1T-BVersion ____________________ E and DCombustion head typeL1Z-B_____ M1/5a-105Kx33L1T-B _____ M1/5a-105Kx36Rating GPH ____________ 1.7 - 8.4MBH _________ 239 - 1,177“WC3.02.52.01.51.00.50.0-0.5-1.0MBH0 200 400 600 800 1,0001,2001,4001,600GPH0 2 4 6 810Burner type _______ L1Z-B and L1T-BVersion ____________________ E and DCombustion head typeL1Z-B_____ M1/5a-100Kx33L1T-B _____ M1/5a-100Kx36Rating GPH ___________ 2.9 - 10.1MBH _________ 410 - 1,416“WC3.02.52.01.51.00.50.0-0.5-1.0MBH0 200 400 600 800 1,0001,2001,4001,600GPH0 2 4 6 810Burner type ________________ M1Z-BVersion ____________________ E and DCombustion head typeM1Z-B ____ M1/5a-105Kx33Rating GPH ____________ 2.2 - 8.1MBH _________ 307 - 1,177“WC3.02.52.01.51.00.50.0-0.5-1.0MBH0 200 400 600 800 1,0001,2001,4001,600GPH0 2 4 6 8106


Burner type ________________ M1Z-BVersion ____________________ E and DCombustion head typeM1Z-B ____ M1/5a-100Kx33Rating GPH ____________ 2.9 - 9.8MBH _________ 410 - 1,416“WC3.02.52.01.51.00.50.0-0.5-1.0MBH0 200 400 600 800 1,0001,2001,4001,600GPH0 2 4 6 810The capacities in relation tocombustion chamber resistances aremaximum values, which weremeasured on idealized test flametubes.Shut off devicesAll burners with an oil throughput > 8GPH (30 kg/h) are equipped with asecond solenoid valve (safety valve) asstandard.All ratings data given relate to an airtemperature of 68F (20°C) and aninstallation height above sea level of1,640ft (500m).The oil throughput information refersto a calorific value of140,000 BTU/Gallon for #2 oil145,000 BTU/Gallon for #4 oilVoltages and frequenciesThe burners are supplied with singlephase 110 V, 60 Hz supply (E), or threephase 460 V, 60 Hz supply (D) asstandard. Other voltages andfrequencies are available upon request.Burner motor standard versionBtrop class insulation, to IP54. Motorscan also be supplied to F classinsulation.7


Size 3 burner selectionBurner rating / combustion chamber pressureBurner type ____ L3Z-A, L3T-A, M3Z-AVersionL-Burner _________ E, D, E-C and D-CM-Burner _______________ D and D-CCombustion head type__ M2/1a-116x40Rating GPH #2 oil ______ 2.9 - 12.7GPH #4 oil ______ 2.8 - 12.4MBH__________ 410 - 1,792“WC3.02.01.00.0-1.0MBH 0400 800 1,200 1,600 2,000 2,400 2,800GPH [#2]0 2 4 6 8GPH [#4]0 2 4 6 810 12 1410 12 14161618182020Burner type ____ L3Z-A, L3T-A, M3Z-AVersionL-Burner _________ E, D, E-C and D-CM-Burner _______________ D and D-CCombustion head type__ M5/2a-116x40Rating GPH #2 oil _______4.6 - 18.8GPH #4 oil _______4.5 - 18.4MBH ___________648 - 2,645“WC3.02.01.00.0-1.0MBH 0400 800 1,200 1,600 2,000 2,400 2,800GPH [#2]0 2 4 6 8GPH [#4]0 2 4 6 810 12 1410 12 141616181820208


Burner type _________________ RL3-AVersion ______________ ZME and ZMDCombustion head type __ M2/1a-116x40Rating GPH ____________2.9 - 12.7MBH __________410 - 1,792“WC3.02.01.00.0-1.0MBH 0400 800 1,200 1,600 2,000 2,400 2,800GPH [#2]0 2 4 6 810 12 14 16 18 20Burner type _________________ RL3-AVersion ______________ ZME and ZMDCombustion head type__M5/2a-116x40Rating GPH ___________ 4.6 - 18.8MBH _________ 648 - 2,645“WC3.02.01.00.0-1.0MBH 0400 800 1,200 1,600 2,000 2,400 2,800GPH [#2]0 2 4 6 810 12 14 16 18 20The capacities in relation tocombustion chamber resistances aremaximum values, which weremeasured on idealized test flametubes.All ratings data given relate to an airtemperature of 68F (20°C) and aninstallation height above sea level of1,640ft (500 m).The oil throughput information refersto a calorific value of140,000 BTU/Gallon for #2 oil145,000 BTU/Gallon for #4 oilShut off devicesAll burners with an oil throughput> 8 GPH (30 kg/h) are equipped with asecond solenoid valve (safety valve) asstandard.Voltages and frequenciesThe burners are supplied with singlephase 110 V, 60 Hz supply (E), or threephase 460 V, 60 Hz supply (D) asstandard. Other voltages andfrequencies are available upon request.Burner motor standard versionBtrop class insulation, to IP54. Motorscan also be supplied to F classinsulation.Modulating burnersThe modulating RL3-A burner is basedon the sliding two stage burner. Themodulating feature is obtained by fitting asuitable modulating controller into thepanel.9


Order numbers, technical informationDescription L1Z-B L1T-B L3Z-A L3Z-AVersion E / D➁ Version E / D➁ Version E / D➂ Version E-C / D-COrder numbers - Version E or EC with integral switchgear 211 163 03 211 193 03 211 363 01 711 365 01Version E or EC without integral switchgear ➀ 211 163 04 211 193 04 211 363 02 711 365 02Version D or DC with integral switchgear 211 164 03 211 194 03 211 364 01 711 366 01Version D or DC without integral switchgear ➀ 211 164 04 211 194 04 211 364 02 711 366 02Version ZME without integral switchgear ➀ – – – –Version ZMD without integral switchgear ➀ – – – –Version E Version E Version E Version E–CBurner motor 1~ 110V, 60 Hz Type EC90/50–2 EC90/50–2 EC90/90–2 EC90/90–2Motor horse power HP/ kW 0.67/ 0.5 0.67/ 0.5 2/ 1.5 2/ 1.5Full Load Amps (FLA) A 8 8 18 18Speed rpm 3400 3400 3450 3450Capacitor µF 16 16 32 32Version D Version D Version D Version D–CBurner motor 3~ 460V, 60 Hz Type D90/50-2 D90/50-2 D90/50-2 D90/50-2Motor horse power HP/ kW 1.13/ 0.85 1.13/ 0.85 1.13/ 0.85 1.13/ 0.85Full Load Amps (FLA) at 460V A 2.3 2.3 2.3 2.3Speed rpm 3400 3400 3400 3400Burner flame safeguard Type LAL 2.25 LAL2.25 LAL2.25 LAL2.25Servomotor Type –w– 1055/23 – W – 1055/80 –w– 1055/23 –w– 1055/23Pump Type AE67 AE67 AE97 AE97Fan galvanized galvanized galvanized galvanizedIgnition transformer V 2 x 5000 2 x 5000 2 x 5000 2 x 5000Oil hoses DN 8 8 8 8Length in inches and (mm) 39” (1000) 39” (1000) 39” (1000) 39” (1000)Connection 3/8” 3/8” 3/8” 3/8”Oil preheater Type – – – –Heating capacity in BTUh and (kW) – – – –Weight lbs/ kg (approx.) 64 (29) 64 (29) 88 (40) 88 (40)➀On burners without integral switchgear, theburner flame safeguard is supplied loose. As anoption it can be mounted on the burner (seepage 12). A terminal strip is provided in bothcases.➁L1Z-B and L1T-B burners, versions E and D, canbe used with this specification up to8 GPH (30 kg/h). Over 8 GPH (30 kg/h) theadditional prices for “Solenoid valve as additionalshut off device” apply (see special equipment,page 12).➂L3Z-A burners, versions E and D, can be usedwith this specification up to 8 GPH (30 kg/h).Over 8 GPH (30 kg/h) L3Z-A burners versionsE-C or D-C should be used (see page 11).These burners are fitted with an LAL 2.25burner flame safeguard and an additional safetysolenoid valve as standard.10


L3T-A RL3-A M1Z-B M3Z-A M3Z-AVersion E-C, D / D-C Version ZME / ZMD Version E / D Version D Version D-C711 395 01 – – – –711 395 02 – 212 163 04 – –711 396 01 – – 712 364 03 712 366 03711 396 02 – 212 164 04 712 364 04 712 366 04– 711 373 02 – – –– 711 374 02 – – –Version E Version ZME Version E – –EC90/90–2 EC90/90–2 EC90/50–2 – –2/ 1.5 2/ 1.5 0.67/ 0.5 – –18 18 8 – –3450 3450 3400 – –32 32 16 – –Version D–C Version ZMD Version D Version D Version D–CD90/50-2 D90/50-2 D90/50–2 D90/50–2 D90/50–21.13/ 0.85 1.13/ 0.85 1.13/ 0.85 1.13/ 0.85 1.13/ 0.852.3 2.3 2.3 2.3 2.33400 3400 3400 3400 3400LAL2.25 LAL2.25 LAL2.25 LAL2.25 LAL2.25-w- 1055/80 SQM 10... –w– 1055/23 –w– 1055/23 –w– 1055/23AE 97 AJ6 E4 E4 E4galvanized galvanized galvanized galvanized galvanized2 x 5000 2 x 5000 2 x 5000 2 x 5000 2 x 50008 8 8 13 1339” (1000) 39” (1000) 20” (500) and 31” (800) 27” (700) and 39” (1000) 27” (700) and 39” (1000)3/8” 3/8” 1/2” 1/2” 1/2”– – EV1B EV2B EV2B– – 6,100 (1.8) 15,350 (4.5) 15,350 (4.5)88 (40) 104 (47) 80 (36) 121 (55) 121 (55)11


Special equipmentItem Description L1… L3…No. M1… M3…Order No.Order No.1 Hours counter in integral switchgear 1 x L…Z + T 210 000 69 210 000 692 x L…Z 210 000 70 210 000 702 x M…Z 210 000 70 210 000 702 Heating for pump E M…Z 110 004 74 110 004 743 Pressure gauge with isolating valve L…Z + T 110 006 63 110 006 63RL – 210 000 92M…Z 110 008 82 110 008 824 Vacuum gauge with isolating valve L…Z + T 110 006 64 110 006 64RL – 110 006 64M…Z 110 005 70 110 005 705 Potentiometer fitted in servomotor (ZM) RL 220 Ohm – 110 002 86RL 1000 Ohm – 110 003 036 Solenoid valve as additional shut off device ➀ M…Z 210 000 47 210 000 497 Solenoid valve for continuous run L…Z without E. 210 005 99 210 005 92to relieve pressure L…Z with E. 210 007 15 210 005 92L…T without E. 210 006 20 210 007 07L…T with E – 210 007 07RL – 210 000 52M…Z 210 000 88 210 000 548 Magnetic clutch for continuous run L…Z without E. 210 003 25 210 001 75to relieve pressure L…Z with E. 210 003 90 210 001 75L…T without E. 210 004 92 210 005 19L…T with E. – 210 005 19RL without E. – 210 001 44M…Z without E. 210 003 26 210 003 01M…Z with E. 210 003 91 –9 Combustion head extensions L1Z 4” (100 mm) 210 003 22 –(for standard burner versions) 8” (200 mm) 210 003 23 –L1T 4” (100 mm) 210 004 76 –8” (200 mm) 210 004 77 –M1Z 4” (100 mm) 210 003 30 –8” (200 mm) 210 003 31 –L3Z 4” (100 mm) – 210 000 198” (200 mm) – 210 000 21L3T 4” (100 mm) – 210 004 798” (200 mm) – 210 004 80RL3 4” (100 mm) – 210 000 238” (200 mm) – 210 000 25M3Z 4” (100 mm) – 210 002 298” (200 mm) – 210 002 3010 Oil meter fitted L1Z 210 005 30 –L1T 210 004 86 –L3Z – 210 004 30L3T – 210 005 2711 Oil hoses 51” (1300) in lieu of 39” (1000 mm) L…Z + T 210 003 00 210 003 0039” (1000 mm), rubber, heated M…Z 210 002 02 210 002 0451” (1300 mm), rubber, heated M…Z 210 002 03 210 002 0512 Flame safeguard LAL 2.25 L…Z Vers. E 210 006 07 –(in combination with LAL 2.25 L…Z Vers. D 210 002 62 –integral switchgear) LAL 2.25 M…Z Vers. D 210 006 05 –13 Flame safeguard LAL 2.25 L…Z Vers. E + D 210 002 54 210 002 54(loose, for fitting intocontrol panel)14 Air intake flange RL… Vers. ZME – 210 003 97RL… Vers. ZMD – 210 003 3515 Intake flange for connection of air duct. 210 000 67 210 000 6716 Type of protection IP54/Industrial version L…Z 210 003 19 210 002 47L…T 210 006 02 210 006 03RL… – 210 004 17M…Z 210 006 04 210 003 77Price reductions17 Oil preheater EV2A in lieu of EV2B M…Z Vers. D and E – 210 004 68EV2A in lieu of EV2B M…Z Vers. D – 210 000 85EV2A in lieu of EV2B M…Z Vers. D-C and E – 210 004 69➀The additional price applies only to burners withoil throughputs up to 8 GPH (30 kg/h). For burners> 8 GPH (30 kg/h) this solenoid valve is fittedas standard.➁Additional price applies to burnersL3Z-A / M3Z-A.12


Burner fuel systemsMonarch L1Z-B and L3Z-A burners Monarch L1T-B and L3T-A burners Monarch RL3-A sliding two stage andmodulating burner without shut offdevice1 44 121 44 121 56 13110V110V110V110V55V55V110V110V55VPM55V110V445a910 6aMonarch M1Z-B and M3Z-A burners< 8 GPH (30 kg/h)Monarch M1Z-B and M3Z-A burners> 8 GPH (30 kg/h)1 3141 5 314110V55VP110V55V110V110V7 85a 97 81 Pump without inbuilt solenoid valve2 Pump with two inbuilt solenoid valves3 Oil preheater4 Normally closed solenoid valve4a Normally open solenoid valve5 Normally closed solenoid valve (1stshut off device in supply line 55 V,electrically connected in series)5a Normally closed solenoid valve (1stshut off device in return line 55 V,electrically connected in series -fitted against direction of flow)6 Normally closed solenoid valve(2nd shut off device in supply line 55V, electrically connected in series)6a Normally closed solenoid valve(2nd shut off device in return line55 V, electrically connected inseries - fitted against direction offlow)7 Normally open solenoid valve(stage 1)8 Normally closed solenoid valve(stage 2)9 Pressure switch in return10 Oil regulator11 Nozzle head with one nozzle, withoutshut off device12 Nozzle head with two / three nozzles,without shut off device13 Nozzle head R, without integral shutoff device14 Nozzle head M, with integral shut offdevice13


DimensionsMonarch L and MMonarch RLSize1 and 3Size 3Monarch L and M, sizes 1 and 3SizeDimensions in inches and (mm)h1 h2 h4 h5 h6 d1 d2 d3 d4 d5 d6 ➁ b1 b2 b3 ➀1 15.3 5.9 11.4 16.5 7.75.3 6.3–6.7 4.7 6.3/6.9➀ 5.0 20.7/20➀ 6.0 10.1/9.4➀M8(388) (150) (290) (420) (195) (135) (160–170) (120) (161/175) (128) (526/507) (153) (257/239)3 17.1 6.7 12.8 18.1 8.76.5 7.3 5.1/5.9➁ 6.3/6.9➀ 5.5/6.3➁ 23.3/21➀ 6.0 12.3/10➀M10(435) (170) (325) (460) (220) (165) (186) (130/150) (161/175) (140/160) (592/533) (153) (312/253)b4 b6 b7 l1 l2 l3 l4 ➁ l5 l6 l7 r1 r21 9.8 7.7 8.3 1.3 3.1 0.3 4.8 7.7 6.6 21.2 21.9➀ 23.6(248) (195) (210) (32) (80) (8) (122) (195) (168) (538) (555) (600)3 11.0 8.7 8.6 1.9 3.9 0.3 4.9/5.3➁ 7.8 7.4 25.4 26.2/25.6➀ 26.6(280) (220) (218) (47) (100) (8) (124/134) (198) (188) (645) (665/650) (675)Monarch RL, Size 3SizeDimensions in inches and (mm)h1 h2 h3 h4 h6 d1 d2 d3 d4 d5 d6 b1 b2 b3 ➀3 17.1 6.7 5.9 12.8 8.76.5 7.3 5.1/5.9➁ 6.3/6.9➀ 5.5/6.3➁ 24.1/21.8➀ 6.0 12.3/10➀M10(435) (170) (150) (325) (220) (165) (186) (130/150) (161/175) (140/160) (612/553) (153) 312/253)b4 b5 b6 b7 l1 l2 l3 l4 l5 l6 l7 l8 r1 r23 11.0 15.2 8.7 8.6 1.9 3.9 0.3 4.9/5.3➁ 7.8 7.4 25.4 8.7 26.2/25.6➀ 25.6(280) (385) (220) (218) (47) (100) (8) (124/134) (198) (188) (645) (220) (665/650) (650)➀ For version E/ version D➁ For combustion head M2/1a, M5/2a14


<strong>Weishaupt</strong> control panelsand burner control system<strong>Weishaupt</strong> control panels for• two stage burners• three stage burners• sliding two stage burnersand modulating burnersThe basic control panels contain allburner controls, necessary for theoperation of a burner.Description<strong>Weishaupt</strong> control panels conform toapplicable national/internationalstandards.Switching includes• Power supply• Burner control• Fan control• Start-up/regulation• Door mounted switches• Door mounted indicating lampsIndividual customer requirements can bemet at any time.<strong>Weishaupt</strong> control technology for• Boiler units• Thermal process equipment• Marine versions• Building management systemsTogether with its core business ofburners and heating systems, <strong>Weishaupt</strong>are able to offer complex control technologyup to BMS level with SPS andDDC systems.From planning to handover, tailor madesolutions are available from one supplier.15


Product and customer service -the complete <strong>Weishaupt</strong> range<strong>Weishaupt</strong> Corporation6280 Danville RoadMississauga, ON L5T 2H7Ph: (905) 564 0946, Fax: (905) 564 0949www.weishaupt-corp.comPrint No. 83002716, July 2002Printed in Germany. All rights reserved.Regular maintenance reduces heatingcosts and environmental pollution. Onlya properly adfusted burner can saveenegy end be environmentally friendly.Behind each <strong>Weishaupt</strong> customerservice organisation. The outstandingefforts made in maintenance and servicejustify the enormous trust places in<strong>Weishaupt</strong>’s burners, for at <strong>Weishaupt</strong>product and customer service belongtogether.<strong>Weishaupt</strong> customer service is there foryou all year round. Whenever you needhelp, be it the supply of spare parts,technical advice or a site visit. We arethere when you need us.