12.07.2015 Views

PTC Control Modes and Ancillaries - Actionair

PTC Control Modes and Ancillaries - Actionair

PTC Control Modes and Ancillaries - Actionair

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

February 2010<strong>PTC</strong> <strong>Control</strong> <strong>Modes</strong> <strong>and</strong> <strong>Ancillaries</strong><strong>PTC</strong> TM <strong>Control</strong> <strong>Modes</strong><strong>and</strong> <strong>Ancillaries</strong>For many years <strong>Actionair</strong> has beenat the forefront in the developmentof fire <strong>and</strong> smoke dampertechnology. To further enhance thisreputation considerable designeffort has been put into the newcontrol modes, ensuring the use ofup to the minute advances indamper technology, as well ascomplying with imminent Europeanst<strong>and</strong>ardisation for fire <strong>and</strong> smokecontrol.The new comprehensive range of<strong>Actionair</strong> <strong>Control</strong> <strong>Modes</strong> are theideal solutions to the many variable<strong>and</strong> complex fire <strong>and</strong> smokedamper control requirements, <strong>and</strong>fully complement the <strong>PTC</strong> damperrange, control panels <strong>and</strong>ancillaries.Dampers <strong>Control</strong>s FancoilsRuskin Air Management Limitedwww.ruskinuk.co.uk


<strong>PTC</strong> <strong>Control</strong> <strong>Modes</strong> <strong>and</strong> <strong>Ancillaries</strong><strong>Control</strong> Mode 5 <strong>PTC</strong> <strong>and</strong> <strong>Control</strong> Mode 6 <strong>PTC</strong><strong>Control</strong> Mode 5 <strong>PTC</strong> <strong>and</strong> <strong>Control</strong> Mode 6 <strong>PTC</strong> 60 seconds MAX Reset/ 22 seconds Release operationThese new series of control modes achieve 60seconds to drive to the end position, with a 20second spring return time. This brings <strong>Actionair</strong>dampers in line with imminent Europeanst<strong>and</strong>ardisation for fire <strong>and</strong> smoke control.As with all <strong>PTC</strong> modes, this series uses thesnaplock interface. Fire rated dampers areprimarily designed to be fitted into a wall or floor,<strong>and</strong> the interface displaces the mode from theline of the wall. Dampers may be installed <strong>and</strong>finally the mode removed from storage for easyfitting, thus preventing damage to the modebefore it is required. End switches <strong>and</strong> LSFcable are provided as st<strong>and</strong>ard on all modes.Versions are available to allow fail-safe close forfire safety (SmokeShield) or fail-safe open forsmoke extract (VentShield) <strong>and</strong> may becombined with protective enclosures (HotShield)to provide enhanced operation for 1 hour at300°C or 2 hours at 300°C.The Electro Thermal Release (ETR) supplied forfire damper use has integral fail-safe devices toensure that it is installed into the ductworkcorrectly. ETR units are not supplied withVentShield, HotShield or Hot/VentShield,because these are designed to operate attemperatures in excess of 72°C, should a firecause any temperature rise or for smoke extract.End switches are provided with each mode, sothat damper Reset <strong>and</strong> Release positions maybe monitored. The mode is permanentlyattached to the mechanism driving the damperblades.ETR Indication lightAs st<strong>and</strong>ard, a green LED lampis built into the ETR housing.This gives the user a simple<strong>and</strong> clear visual check that theActuator is receiving power, theETR is correctly fitted, <strong>and</strong> thethermal fuse is intact.SmokeShield <strong>and</strong> VentShieldM5 <strong>PTC</strong> 10/2W (12.5VA MAX) 24V end switches SPDT 250V 6(3)A XNNN00015 SmokeShield Thermal Release / Power Off – Fail-safe Close*M6 <strong>PTC</strong> 12/4W (14VA MAX) 230V end switches SPDT 250V 6(3)A XNNN00016 SmokeShield Thermal Release / Power Off – Fail-safe Close*M5 <strong>PTC</strong> Vent NON ETR 10/2W (12.5VA MAX) 24V end switches SPDT 250V 6(3)A XNNN00021 VentShield Power Off – Fail-safe OpenM6 <strong>PTC</strong> Vent NON ETR 12/4W (14VA MAX) 230V end switches SPDT 250V 6(3)A XNNN00022 VentShield Power Off – Fail-safe OpenM5 <strong>PTC</strong> NON ETR 10/2W (12.5VA MAX) 24V end switches SPDT 250V 6(3)A XNNN00017 SmokeShield Power Off – Fail-safe CloseM6 <strong>PTC</strong> NON ETR 12/4W (14VA MAX) 230V end switches SPDT 250V 6(3)A XNNN00018 SmokeShield Power Off – Fail-safe CloseM5 <strong>PTC</strong> Vent 10/2W (12.5VA MAX) 24V end switches SPDT 250V 6(3)A XNNN00019 VentShield Thermal Release / Power Off – Fail-safe Open*M6 <strong>PTC</strong> Vent 12/4W (14VA MAX) 230V end switches SPDT 250V 6(3)A XNNN00020 VentShield Thermal Release / Power Off – Fail-safe Open**SmokeShield M5 <strong>PTC</strong> <strong>and</strong> M6 <strong>PTC</strong> are supplied as st<strong>and</strong>ard with the Electrical Thermal Release (ETR). The units Fail-safe by means of theunique <strong>and</strong> patented ETR device which operates at 72 °C, or if the power supply is off/interrupted. Complying with BS 5588 Part 9 1999. NonETR versions Fail-safe when the power is off/interrupted.HotShield <strong>and</strong> Hot/VentShieldHM5 <strong>PTC</strong> 10/2W (12.5VA MAX) 24V end switches SPDT 250V 6(3)A XNNN00281 HotShield Power Off – Fail-safe CloseHM6 <strong>PTC</strong> 12/4W (14VA MAX) 230V end switches SPDT 250V 6(3)A XNNN00282 HotShield Power Off – Fail-safe CloseHMV5 <strong>PTC</strong> Vent 10/2W (12.5VA MAX) 24V end switches SPDT 250V 6(3)A XNNN00283 Hot/VentShield Power Off – Fail-safe OpenHMV6 <strong>PTC</strong> Vent 12/4W (14VA MAX) 230V end switches SPDT 250V 6(3)A XNNN00284 Hot/VentShield Power Off – Fail-safe OpenHM5-2H <strong>PTC</strong> 10/2W (12.5VA MAX) 24V end switches SPDT 250V 6(3)A XNNN00285 HotShield Power Off – Fail-safe CloseHM6-2H <strong>PTC</strong> 12/4W (14VA MAX) 230V end switches SPDT 250V 6(3)A XNNN00286 HotShield Power Off – Fail-safe CloseHMV5-2H <strong>PTC</strong> Vent 10/2W (12.5VA MAX) 24V end switches SPDT 250V 6(3)A XNNN00287 Hot/VentShield Power Off – Fail-safe OpenHMV6-2H <strong>PTC</strong> Vent 12/4W (14VA MAX) 230V end switches SPDT 250V 6(3)A XNNN00288 Hot/VentShield Power Off – Fail-safe OpenHotShield <strong>and</strong> Hot/VentShield <strong>Control</strong> <strong>Modes</strong> HM5 <strong>PTC</strong> <strong>and</strong> HM6 <strong>PTC</strong> (operational for 1 hour @ 300 °C) <strong>and</strong> HM5 – 2H <strong>PTC</strong> <strong>and</strong> HM6 – 2H <strong>PTC</strong>(operational for 2 hours @ 300 °C) are not supplied with the Electrical Thermal Release (ETR). They Fail-safe when the power is off/interrupted).2 www.actionair.co.uk


<strong>PTC</strong> <strong>Control</strong> <strong>Modes</strong> <strong>and</strong> <strong>Ancillaries</strong><strong>Control</strong> Mode 5 – 3P <strong>PTC</strong><strong>Control</strong> Mode 5 – 3P <strong>PTC</strong> with additionalfacility for third (control) PositionThis new 3 position control mode allows adamper to be moved to both the reset <strong>and</strong>release position, with the additional facility tomove the damper to a third control position.The mode is given a 2-10V DC signal,defining the position that the damper needs tobe set at.SmokeShield <strong>and</strong> VentShieldA return signal of 2-10V DC is provided toallow monitoring of position.To support this actuator <strong>and</strong> allow positioningto be set local to the damper, <strong>Actionair</strong> havedeveloped the M5-3P-CMS control unit.As with all <strong>PTC</strong> modes, this series uses thesnaplock interface. Fire rated dampers areprimarily designed to be fitted into a wall orfloor, <strong>and</strong> the interface displaces the modefrom the line of the wall. Dampers may beinstalled <strong>and</strong> then the mode removed fromstorage for easy fitting, thus preventingdamage to the mode before it is required.End switches, LSF cable, <strong>and</strong> Electro ThermalRelease (ETR) are provided as st<strong>and</strong>ard on allmodes.Versions are available to allow fail-safe closefor fire safety or fail-safe open for smokeventing <strong>and</strong> may be combined with protectiveenclosures (HotShield) to provide furtherprotection for 1 hour at 300°C.M5-3P <strong>PTC</strong> 24V 7/2W (10VA) end switches SPDT 250V 6(3)A XNNN00289 SmokeShield Thermal Release / Power Off – Fail-safe Close 2-10V Set PositionM5-3P <strong>PTC</strong> Vent NON ETR 24V 7/2W (10VA) end switches SPDT 250V 6(3)A XNNN00293 VentShield Power Off – Fail-safe Open 2-10V Set PositionM5-3P <strong>PTC</strong> NON ETR 24V 7/2W (10VA) end switches SPDT 250V 6(3)A XNNN00291 SmokeShield Power Off – Fail-safe Close 2-10V Set PositionM5-3P <strong>PTC</strong> Vent 24V 7/2W (10VA) end switches SPDT 250V 6(3)A XNNN00292 VentShield Thermal Release / Power Off – Fail-safe Open 2-10V Set PositionHotShield <strong>and</strong> Hot/VentShieldM5 - 3P 24V <strong>and</strong> M5 - 3P 230V CMS <strong>Control</strong> StationsM5 –3P –CMSHotShield <strong>and</strong> Hot/VentShield <strong>Control</strong> <strong>Modes</strong> HM5 – 3P <strong>PTC</strong> (operational for 1 hour @ 300 °C) are not supplied withElectrical Thermal Release (ETR) <strong>and</strong> Fail-safe when the power is off/interrupted. NOTE: 1 hour version only available.M5 –3P –CMS (230V)The M5-3P CMS (<strong>Control</strong> Monitoring Station) this controlunit gives the user the opportunity to set a control positionusing an integral potentiometer, or use an externallysupplied control voltage. It provides visual (lamp) <strong>and</strong> voltfree (relay) indication of damper position (Released, at<strong>Control</strong> Position, Reset). A terminal is provided to allowfeedback of the 2-10V DC monitoring voltage. In addition,a fire alarm input may be made (NC) which will cause thedamper to Release if the contact is broken. A secondinput is available to cause the damper to fully Reset toallow full air flow for smoke venting as an example. Thefire alarm Release input takes precedence. Switches areprovided that allow the unit to be driven to Release orReset positions for testing purposes.SmokeShield M5 – 3P <strong>PTC</strong> are supplied with the Electrical Thermal Release (ETR). The units Fail-safe by means of the unique <strong>and</strong> patentedETR device which operates at 72 °C, or if the power supply is off/interrupted. Complying with BS 5588 Part 9 1999. Non ETR versions Fail-safewhen the power is off/interrupted.HMV5-3P <strong>PTC</strong> 24V 7/2W (10VA) end switches SPDT 250V 6(3)A XNNN00294 HotShield Power Off – Fail-safe Close 2-10V Set positionHMV5-3P <strong>PTC</strong> Vent 24V 7/2W (10VA) end switches SPDT 250V 6(3)A XNNN00295 Hot/VentShield Power Off – Fail-safe Open 2-10V Set position<strong>Control</strong> Mode 5–2P <strong>PTC</strong> <strong>and</strong><strong>Control</strong> Mode 6–2P <strong>PTC</strong>Drive open / Drive closed. 60 seconds operationThis new 2 position control mode has beendeveloped to provide drive open/drive closeddamper operation <strong>and</strong> it brings <strong>Actionair</strong>dampers in line with imminent EuropeanSmokeShield <strong>and</strong> VentShieldSt<strong>and</strong>ardisation for fire <strong>and</strong> smoke control, wherefor a given smoke control philosophy, or smokesource, a damper may be required to open orclose to vent or contain the smoke. This is aradical alternative to the traditional spring returnactuator, where upon power failure, instead ofmoving to fail-safe position, it remains in itsdesired emergency position. For any smokecontrol emergency situation, this is an absolutenecessity. These modes do not have ETR’s.As with all <strong>PTC</strong> actuators, this series uses thesnaplock interface. All modes have LSF cables.Versions are available combined with protectiveenclosures (HotShield) to provide further protectionfor 60 mins at 300 °C or 30 mins at 600 °C.M5-2P <strong>PTC</strong> 24V 12W 0.5W (18VA), end switches SPDT 250V 6(3)A XNNN00296M6-2P <strong>PTC</strong> 230V 8W 0.5W (15VA), end switches SPDT 250V 6(3)A XNNN00297HotShield <strong>and</strong> Hot/VentShieldHM5-2P <strong>PTC</strong> 24V 12W 0.5W (18VA), end switches SPDT 250V 6(3)A XNNN00298HM6-2P <strong>PTC</strong> 230V 8W 0.5W (15VA), end switches SPDT 250V 6(3)A XNNN00299Mode 9 <strong>PTC</strong>This mode has been developed to providepneumatic operation of the damper <strong>and</strong> is availablein spring return versions for fail-safe operation. Apneumatic thermal release (PTR) assembly isavailable to react to fire conditions. As with all <strong>PTC</strong>actuators, this series uses the snaplock interface.Switch box <strong>and</strong> solenoid accessories available, inaddition a 250 °C for 1 hour hot version is available.M9 <strong>PTC</strong> PneumaticAir Off – Fail-safe CloseM9 <strong>PTC</strong> Vent PneumaticAir Off – Fail-safe OpenHM9 <strong>PTC</strong> PneumaticAir Off – Fail-safe CloseHM9 <strong>PTC</strong> Vent PneumaticAir Off – Fail-safe OpenXNNN00300XNNN00303XNNN00301XNNN00304www.actionair.co.uk3


<strong>PTC</strong> <strong>Control</strong> <strong>Modes</strong> <strong>and</strong> <strong>Ancillaries</strong><strong>Ancillaries</strong>The <strong>Actionair</strong> <strong>Control</strong> <strong>Modes</strong> are supported byvarious additional panels/equipment. Theserange from comprehensive smoke controlsystems (Actionpac LNS3) <strong>and</strong> bespokeelectromechanical panels (Actionpac EMB),which are described in other publications(available from the website), to those itemsdescribed below which are available asst<strong>and</strong>ard accessories.Please note: Actionpac EMS <strong>Control</strong> Panelis not suitable for 2P or 3P Type <strong>Control</strong><strong>Modes</strong>.AccessoriesOther Electrical AccessoriesActionpac EMS <strong>Control</strong> PanelThis product has been developed to provide a st<strong>and</strong>ard solution for the control ofsmall groups of dampers. The panels can control up to 12, 24 or 36 dampersrespectively. The panels offer individual damper position status, zonal dampertesting, max 2 zones of 6 (per 12 dampers), fire alarm inputs per group of 12 dampers <strong>and</strong> voltfree outputs for BMS monitoring in the case of alarms or faults. This product has its owndetailed catalogue available <strong>and</strong> the <strong>Actionair</strong> Sales Office may be contacted for specific details.EMS 12 - 24 24V AC XNNN00268 Actionpac EMS 12 - 24EMS 12 - 230 230V AC XNNN00267 Actionpac EMS 12 - 230EMS 24 - 24 24V AC XNNN00270 Actionpac EMS 24 - 24EMS 24 - 230 230V AC XNNN00269 Actionpac EMS 24 - 230EMS 36 - 24 24V AC XNNN00272 Actionpac EMS 36 - 24EMS 36 - 230 230V AC XNNN00271 Actionpac EMS 36 - 230A range of indicator panels, push button switches <strong>and</strong> damper test units are also available. The housingfor these units are manufactured in rigid ABS plastic. The Damper Connection Box is in galvanised steel.Damper Test UnitReset <strong>and</strong> release indication.Spring bias (power OFF) test switch.Power normally ON.Damper Status IndicatorReset <strong>and</strong> release indication.Damper <strong>Control</strong> UnitSwitch ON/OFF function.Reset <strong>and</strong> release indication.M5 <strong>and</strong> M6 – 2P Damper <strong>Control</strong> UnitSwitches power <strong>and</strong> open/closed.Open <strong>and</strong> closed indication.Damper Connection Box(All Voltages)M5 – 3P – CMS <strong>Control</strong> UnitDTU24 24V AC/DC XNNN00010DTU120 120V AC XNNN00305DTU230 230V AC DNNN00029DSI24 24V AC/DC DPNN00412DSI120 120V AC XNNN00308DSI230 230V AC DPNN00413DCU24 24V AC/DC XNNN00309DCU120 120V AC XNNN00310DCU230 230V AC XNNN00311M52PDCU 24V AC/DC XNNN00313M62PDCU 230V AC XNNN00314DCB 24V –230V AC/DC XNNN00312M5 – 3P – CMS 24V AC/DC XNNN00315M5 – 3P – CMS (230V)M5 – 3P –CMS 230V AC XNNN00599(230V)Damper Release <strong>and</strong> Indication Module(DRIM)This is designed for control <strong>and</strong> monitoringof the electrically operatedSmokeShield <strong>PTC</strong> Fire <strong>and</strong> Smokedampers.It will operate from 24, 120 or 230 voltsupplies, 50 or 60 Hz.Selection of the operating voltage is byuse of internal links on the PCB,prior to installation <strong>and</strong> connectionof actuator <strong>and</strong> supply.The DRIM may be used singly toprovide local damper control, or inpairs to provide control from eitherside of a damper. It can alsooperate 2 actuators when dampersare provided in 2 multiple sectionsLED position <strong>and</strong> operation indicationis provided.Operation is by push button to close<strong>and</strong> twist to re-open damper.Tested to BS EN 61010 -1: 2001 <strong>and</strong>is CE compliant.IP44 rated.Operating range 5 - 40 degrees C.DRIM 24V – 230V AC/DC XNNN00589Ruskin Air Management LimitedSouth Street, Whitstable, Kent CT5 3DU Engl<strong>and</strong>.Tel: 01227 276100 Fax: 01227 264262Email: sales@actionair.co.uk Website: www.actionair.co.ukRuskin Air Management Limitedis a ISO 9001 <strong>and</strong> 14001registered companyLNNN00113

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!