12.07.2015 Views

UNIVERSAL DEFROST TIMERS 9145 / 9045 Series - Uni-Line

UNIVERSAL DEFROST TIMERS 9145 / 9045 Series - Uni-Line

UNIVERSAL DEFROST TIMERS 9145 / 9045 Series - Uni-Line

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>9145</strong> / <strong>9045</strong><strong>Series</strong><strong>UNIVERSAL</strong><strong>DEFROST</strong><strong>TIMERS</strong>As Easy As 1 – 2 – 31. Set TimeScroll cursor to desired time.Select SET TIME button.2. Set DefrostScroll cursor to desired defrost times.Select <strong>DEFROST</strong> START/STOP button.Features and BenefitsThe Paragon ® <strong>9045</strong>-00 and <strong>9145</strong>-00 <strong>Uni</strong>versalDefrost Timers are the only multi-voltage defrosttimers engineered to refrigeration standards.At four defrosts per day, the Paragon <strong>Uni</strong>versalDefrost Timer switches last 16 years longer thancompetitive offerings.• Certified to UL873 Standard for Temperature-Indicating and Regulating Equipment, asRefrigeration Controllers• Wires directly to 120V AC, 208V AC or230V AC power sources without jumpersor switches• Easy programming, easy set-up, set time, setdefrost start and defrost end• Initiate 15 minute manual defrost• 100 hours of power loss protection for bothtime and defrost schedule• Display shows defrost start time and duration• Real-time clock• Lighted display• System status indicators• Mechanism-only versions designed to fit in thestandard Paragon enclosures3. Clear DefrostRotate cursor to the first segment in thedefrost screen.Select CLEAR button.Additional programming features are just assimple to use. Install our <strong>Uni</strong>versal DefrostTimer today to understand why Paragon ® isSimply the Right Choice in Defrost Timers.An ISO 9001 – 2008 Certified Company1 YearLimitedWarranty


<strong>9145</strong> / <strong>9045</strong><strong>Series</strong><strong>UNIVERSAL</strong><strong>DEFROST</strong><strong>TIMERS</strong>Ordering Information<strong>9145</strong>-00 Time Initiate/Temperature, Pressure Terminate Defrost Timer withMetal Enclosure<strong>9145</strong>-00M Time Initiate/Temperature, Pressure Terminate Defrost Timer –Mechanism Only<strong>9045</strong>-00 Time Initiate/Time Terminate Defrost Timer with Metal Enclosure<strong>9045</strong>-00M Time Initiate/Time Terminate Defrost Timer – Mechanism OnlySystem StatusIndicatorsInitiate 15 MinuteManual DefrostSpecificationsInput Power120/208–240 VAC 60 Hz (+10, -15%)Power Consumption6VA max, Defrost termination switch(terminal “G”) input impedance toterminal C: 85kΩ +/- 5%Operating Voltage102 VAC min to 132 VAC max @ 60 Hz176.8 VAC min to 264 VAC max @ 60HzNOTE: No user-required adjustmentsto switch between the high andlow voltage.Ambient Operating Conditions-40°F to 131°F (-40°C to 55°C);0 to 95% RH(non-condensing)Storage Temperature-40°F to 140°F (-40°C to 60°C)<strong>9145</strong> Terminal Data*Outside DimensionsIndividual unit4.40”W x 7.82”H x 3.80”DIndividual unit (in shipping box)4.75”W x 8.875”H x 4.75”DIndividual Case Shipping Weight3.2 lbsAgency ListingsFile number SA512 (<strong>9045</strong>-00and <strong>9145</strong>-00)File number SA512(<strong>9045</strong>-00M and <strong>9145</strong>-00M)The devices are listed as RefrigerationControllers.Lighted displayshows defroststart time anddurationEasy Set-UpSet TimeSet Defrost Startand Defrost EndDirect Connect<strong>Line</strong> Voltage –120/208-240V ACTerminal A B C D E F GRelay ContactRelayRatingSPDTNC Contact15A resistive @120 VAC to 240 VAC1/4HP @ 120 VAC,1/2HP @ 208 VACto 240 VACSPDTNO Contact30A resistive @120 VAC to 240 VAC1HP @ 120 VAC,2HP @ 208 VACto 240 VACSPDTCOMM ContactSPDTNO ContactSPSTCOMM contact30A resistive @120 VAC to 240 VAC1HP @ 120 VAC,2HP @ 208 VACto 240 VACL2/NPower in to timerDefrost TerminationDevice Input L2/N sideDeviceConnectionsFan (Typical)Compressor(Optional)Defrost Device(Typical)L1 Power to timerand to DefrostTermination DeviceCompressor(Typical)Fan (Optional)* <strong>9145</strong> is a general purpose defrost timer and can be used for both Time Initiate/Time Terminate and Time Initiate/Temperature, Pressure TerminateDefrostTerminationSwitch90 45 Terminal DataTerminal A B C D E F GRelay Contact SPST #1NC ContactRelayRating30A resistive @120 VAC to 240 VAC1HP @ 120 VAC,2HP @ 208 VACto 240 VACSPST #1COMM ContactL1Power in to timerSPST #2NO ContactSPST #2COMM Contact30A resistive @120 VAC to 240 VAC1HP @ 120 VAC,2HP @ 208 VACto 240 VACL2/NPower in to timerNo ConnectionDeviceConnectionsCompressor(Typical)Defrost Drive(Typical)


<strong>9145</strong> / <strong>9045</strong><strong>Series</strong><strong>UNIVERSAL</strong><strong>DEFROST</strong><strong>TIMERS</strong>Applications and Wiring Diagrams<strong>9045</strong>AIR<strong>DEFROST</strong>TimeInitiatedTimeTerminatedTIMERA B C D E F GT'STAT<strong>9145</strong>ELECTRIC<strong>DEFROST</strong>TimeInitiatedTemperatureTerminatedTIMERTerminal "G" DefrostTermination Sense CircuitryA B C D E F GT'STATCOMPRESSORFANHEATERCOMPRESSOR<strong>DEFROST</strong>TERMINATION/FANL, L1 N, L2L, L1 N, L2<strong>9045</strong>ELECTRIC<strong>DEFROST</strong>TimeInitiatedTimeTerminatedTIMERA B C D E F GT'STAT<strong>9145</strong>AIR<strong>DEFROST</strong>TimeInitiatedTimeTerminatedTIMERTerminal "G" DefrostTermination Sense CircuitryA B C D E F GT'STATCOMPRESSORHEATERCOMPRESSORL, L1 N, L2L, L1 N, L2<strong>9145</strong>ELECTRIC<strong>DEFROST</strong>TimeInitiatedTimeTerminatedTIMERTerminal "G" DefrostTermination Sense CircuitryA B C D E F GT'STATFANHEATERCOMPRESSORL, L1 N, L2


<strong>9145</strong> / <strong>9045</strong><strong>Series</strong><strong>UNIVERSAL</strong><strong>DEFROST</strong><strong>TIMERS</strong>Conversion Diagrams for Paragon Mechanical ControlsConvert 8041 to <strong>9145</strong>8041 N 1 43 2 XConvert 8045 to <strong>9045</strong>8045 2 N 14 3 X<strong>9145</strong> A B C D E F G<strong>9045</strong> A B C D E FConvert 8141 to <strong>9145</strong>8141 N 1 43 2 XConvert 8143 to <strong>9145</strong>8143 1 N 23 4 X<strong>9145</strong> A B C D E F G<strong>9145</strong> A B C D E F GConvert 8145 to <strong>9145</strong>8145 3 4 X1 2 N<strong>9145</strong> A B C D E F G191 E. North AvenueCarol Stream Illinois 60188 USACustomer Service Telephone 1.800.304.6563Customer Service Facsimile 1.800.426.0804HVACCustomerService@Invensys.comFor Technical ServiceTelephone 1.800.445.8299Facsimile 1.630.260.7294TechnicalService@Invensys.comInvensys, <strong>Uni</strong>-<strong>Line</strong> ® and Simply the Right Choiceare trademarks of Invensys plc., its subsidiaries and/oraffiliated companies. All other brands mentioned maybe the trademarks of their respective owners.www.<strong>Uni</strong>-<strong>Line</strong>.comwww.InvensysControls.com©2010 Invensys Controls2/10 – 150-1893D

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!