12.07.2015 Views

Apollo Valves - Actuator Control - Wainbee Limited

Apollo Valves - Actuator Control - Wainbee Limited

Apollo Valves - Actuator Control - Wainbee Limited

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Actuator</strong>s and <strong>Control</strong>sTechnical DataDouble ActingAD0012 AD0025 AD0040 AD0065 AD0100 AD0150 AD0200 AD0350 AD0600 AD0950 AD1600 AD2500 AD4000Weight (lbs) 1.3 2.9 4.0 5.3 6.8 10.5 12.8 23.0 43.0 58.0 95.0 125.0 191.0Spring ReturnAS0012 AS0025 AS0040 AS0065 AS0100 AS0150 AS0200 AS0350 AS0600 AS0950 AS1600 AS2500 AS4000Weight (lbs) 1.5 3.7 5.3 7.9 10.1 15.2 20.1 37.0 61.0 85.0 145.0 194.0 291.0Displacement (cu in.) AD0012 AD0025 AD0040 AD0065 AD0100 AD0150 AD0200 AD0350 AD0600 AD0950 AD1600 AD2500 AD4000AS0012 AS0025 AS0040 AS0065 AS0100 AS0150 AS0200 AS0350 AS0600 AS0950 AS1600 AS2500 AS4000Port A CCW 3.1 6.1 9.8 20 21 45 49 110 177 287 445 488 824Port B CW 3.7 6.7 13 22 30 40 61 116 189 299 488 568 1068Air consumption (scf per 90°) = (Displacement/1728)*(Supply Pressure + 14.7)/14.7Operating TimeAD0012 AD0025 AD0040 AD0065 AD0100 AD0150 AD0200 AD0350 AD0600 AD0950 AD1600 AD2500 AD4000AS0012 AS0025 AS0040 AS0065 AS0100 AS0150 AS0200 AS0350 AS0600 AS0950 AS1600 AS2500 AS4000Seconds 0.4 0.5 0.7 1.1 1.2 1.8 2.3 3.6 4.5 5.4 6.9 7 12Selecting/Sizing <strong>Apollo</strong> Rack & Pinion <strong>Actuator</strong>sEstablish the valve operating torque beginning with the torque constants for the appropriate pressure and valve as found on pages 41 or 42. Usethe torque adjustment factors found on page 43 to arrive at an in-service torque figure. Multiple adjustment factors may be required. Do not forgetto include adjustments for graphite stem packings (valve options -21, 24 or 65 for conventional ball valves, BO, BS, EV, FD and FP for TEVs’)For Double Acting <strong>Actuator</strong>sBased on the available air supply select an actuator with torque outputs that exceed the in-service torque by at least 10%.For Spring Return <strong>Actuator</strong>sConsidering the available air supply, select an actuator where both the Spring-Ending torque figure and the Air-Ending torque figure exceeds thein-service torque by at least 10%.Note: Single-Stop actuators are appropriate for use on ball valves. Dual-Stop actuators are required for most butterfly valve applications with afew exceptions but may also be used on ball valves.<strong>Apollo</strong> ® Pneumatic <strong>Actuator</strong> Numbering SystemA X - X X X X - X - X X - X - XACTIOND - Double ActiongS - Spring ReturnK - KitSIZE0012*00250040006501000150020003500600095016002500*4000*SEAL OPTIONN - Nitrile (Normal temprange, -4° to 175°F)H - Fluorocarbon (Hightemp range, -4° to250°F)L - Silicone (Low temprange, -40° to 175°F)SPRING SET00 (DA)0102030405060708101214LIMIT STOP0- None** (Std. onsizes 0012,2500, & 4000)1 -Single AdjustableLimit Stop (Forsizes 0025 thru1600 only)2 -Dual AdjustableLimit Stops (Forsizes 0025 thru1600 only)INSERTA - STDB - Without* Units with no adapters option** Optional double stroke adjustment plate is availablefor 2500 & 4000 (see price list)NOTE: Add suffix “F” for fail open units10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!