Lab Experiment No. 5: Single-Phase Motors
Lab Experiment No. 5: Single-Phase Motors
Lab Experiment No. 5: Single-Phase Motors
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
EE 448 <strong>Lab</strong>oratory <strong>Experiment</strong> 5<strong>Single</strong> <strong>Phase</strong> Induction <strong>Motors</strong>start motors have the same running characteristics as their split-phasecounterparts.The capacitor and the start winding are disconnected by a centrifugalswitch, just as in the case of the standard split-phase motor. Reversing thedirection of rotation of a capacitor start motor is the same as in the case ofthe split-phase motor, that is, reverse the connections to the start or to therunning winding leads to the supply/source.- 3 -