<strong>Varian</strong> <strong>High</strong> <strong>Energy</strong> <strong>Clinac</strong> <strong>Main</strong> <strong>Circuit</strong> <strong>Breaker</strong><br />

<strong>Panel</strong> <strong>with</strong> <strong>Battery</strong> Backup <strong>Circuit</strong><br />

Application<br />

The <strong>Clinac</strong> <strong>Main</strong> <strong>Breaker</strong> <strong>Panel</strong> is a custom panel that serves<br />

as the main power disconnect between the <strong>Clinac</strong> system and<br />

the facility 240V or 208V power source. The panel provides<br />

emergency disconnection and overcurrent protection, and<br />

will maintain the main breaker undervoltage (UVR) holding<br />

circuit during any loss of power. The (battery backup)<br />

holding circuit is disabled whenever any emergency off<br />

pushbutton is pressed. The standardized design provides a<br />

platform for future upgrades of the system. The panel offers<br />

the customer, specifier, and the installer a number of<br />

advantages by combining a variety of individual components<br />

into a single pre-engineered and factory tested panel. Each<br />

panel is UL and cUL listed for compliance <strong>with</strong> the<br />

approvals required by NEC Article 100 and Article 110-3.<br />

The main circuit breaker is wired to the <strong>Clinac</strong> system and<br />

provides immediate shut down of the entire system to<br />

comply <strong>with</strong> NEC required disconnecting means. The panel<br />

may be surface or semi-flush mounted, and can be utilized<br />

for a variety of applications where low-voltage control of the<br />

main power source is desired.<br />

<strong>Varian</strong> <strong>High</strong> <strong>Energy</strong> <strong>Clinac</strong>s supported:<br />

2100C (all models), 21EX<br />

2300C (all models), 23EX<br />

iX (all models), Trilogy, Novalis-Tx<br />

SILHOUETTE (all models)<br />

Benefits<br />

• Approved by <strong>Varian</strong> Engineering<br />

• Minimizes down time by maintaining power to the main<br />

breaker (UVR) holding circuit during continuous power<br />

interruptions of up to three days.<br />

• <strong>Main</strong> breaker will not trip during power interruption due<br />

to generator testing.<br />

• Developed specifically for use <strong>with</strong> <strong>Varian</strong> Systems.<br />

• Reduces installation time and cost by providing a singlepoint<br />

power connection, thus eliminating the need to<br />

mount and wire several individual components.<br />

• Uniform factory design eliminates individual project<br />

engineering costs, and delays of on site fabrication.<br />

• Eliminates the sourcing and delivery delays associated<br />

<strong>with</strong> obtaining multiple components from a variety of<br />

suppliers.<br />

• UL and cUL listed to conform to local codes,<br />

minimizing potential inspection and acceptance issues.<br />

• Standardized design and testing assures high product<br />

quality and system reliability.<br />

• Single panel provides for a more attractive, colorcoordinated<br />

installation.<br />

MAIN CIRCUIT BREAKER<br />

PANEL<br />

14.625"<br />

Depth 6"<br />

Features<br />

• 65,000 amps Short <strong>Circuit</strong> Current Rating to meet<br />

rigorous hospital power system requirements.<br />

• <strong>Main</strong>tains breaker during momentary outages.<br />

• battery backup maintains UVR circuit capability<br />

for at least three days.<br />

• Single panel completely assembled and tested.<br />

• Custom wiring diagram speeds installation.<br />

• UL and cUL listed to conform to NEC.<br />

• Complies <strong>with</strong> NEC Article 100 Definition of<br />

Approved and Article 110-3 Approved.<br />

• Provides low voltage, 24V dc operation via an<br />

integral control power transformer, <strong>with</strong> batteries<br />

and charger. Convertible…adapts from 240V ac to<br />

208V ac by changing a jumper, undervoltage<br />

release.<br />

• <strong>High</strong> interrupting solid-state 65kAIC-240V rated<br />

molded case breaker <strong>with</strong> adjustable instantaneous<br />

trip.<br />

• Padlocking provisions for OSHA lockout/tagout<br />

included on the panel cover and on the individual<br />

main breaker handle.<br />

• Time delay current limiting fuses provide<br />

protection for the primary of the control power<br />

transformer.<br />

• Isolated neutral lugs.<br />

• Oversized ground lugs for parity sizing of ground<br />

wire.<br />

• Provisions for additional control features for<br />

integration <strong>with</strong> building automation system,<br />

security system, or remote system shut down<br />

alarm.<br />

• Finger safe fuse blocks for control circuit fuses.<br />

• Rated 70A for <strong>Varian</strong> 600C or 150A for the 2100,<br />

2300, 21EX, 23EX, iX, Trilogy and Novalis-Tx<br />

models.<br />

• Includes two mushroom Emergency OFF<br />

pushbuttons, stainless steel wall plate and<br />

nameplate, to be wired per <strong>Varian</strong> requirements.<br />

• Surface or semi-flush mounting.<br />

©Copyright 2009 1 of 3 Product Data <strong>Clinac</strong> 2100CBB 7-28-2009<br />

24"


<strong>Varian</strong> <strong>High</strong> <strong>Energy</strong> <strong>Clinac</strong> <strong>Main</strong> <strong>Circuit</strong> <strong>Breaker</strong><br />

<strong>Panel</strong> <strong>with</strong> <strong>Battery</strong> Backup <strong>Circuit</strong><br />

• Custom tailored for <strong>Varian</strong> Systems.<br />

Physical Specifications<br />

Height: 24 inches (609.6 mm)<br />

Width: 14.625 inches (371.5 mm)<br />

Depth: 6 in. (approx.) (152.4 mm)<br />

Weight: 70 pounds ( 31.75 kg)<br />

<strong>Main</strong> lug wires #3/0 max.<br />

Mounting: Via keyhole slots: width is 9.5<br />

inches on centers. Height is 22 inches on<br />

centers (see diagram).<br />

4” of enclosure may be recessed in wall<br />

for semi flush installations.<br />

Conduits may enter or exit from top, bottom, or<br />

sides. Preferred location is incoming near top<br />

and outgoing at the bottom. Rear conduits not<br />

possible. Exact location must be field verified.<br />

Specifiers please include GE<br />

Supply contact phone number<br />

(1-800-200-9760) (317-554-3876)<br />

on your drawings to aid hospital<br />

or contractor in purchasing.<br />

Available from GEXPRO<br />

1-800-200-9760, (317-554-3876)<br />

7:30-4:30 PM Central time.<br />

©Copyright 2009 2 of 3 Product Data <strong>Clinac</strong> 2100CBB 7-28-2009


<strong>Varian</strong> <strong>High</strong> <strong>Energy</strong> <strong>Clinac</strong> <strong>Main</strong> <strong>Circuit</strong> <strong>Breaker</strong><br />

<strong>Panel</strong> <strong>with</strong> <strong>Battery</strong> Backup <strong>Circuit</strong><br />

Products<br />

All products are suitable for use on 240V or<br />

208V systems and provide for 24V DC control<br />

circuit.<br />

<strong>Varian</strong> <strong>High</strong> <strong>Energy</strong> <strong>Clinac</strong>s<br />

supported:<br />

2100C (all models), 21EX<br />

2300C (all models), 23EX<br />

iX (all models), Trilogy, Novalis-Tx<br />

SILHOUETTE (all models)<br />

208-240V, 60 Hz, 65,000 amps Short <strong>Circuit</strong><br />

Current Rating, Surface or Semi-Flush Mounted<br />

150A <strong>Main</strong> <strong>Breaker</strong> <strong>Panel</strong>, UL and cUL<br />

labeled, includes two remote Emergency OFF<br />

mushroom pushbuttons.<br />

Catalog#: 2100CBB150A<br />

50 Hz, CE units available by<br />

special order.<br />

208V<br />

3PH/60 Hz<br />

3/0 Max<br />

Conductor<br />

3φ4 W<br />

+<br />

Ground<br />

Available from GEXPRO<br />

1-800-200-9760, (317-554-3876)<br />

7:30-4:30 PM Central time.<br />

Specifiers please include GE Supply contact<br />

phone number (1-800-200-9760) (317-554-3876)<br />

on your drawings to aid hospital or contractor in<br />

purchasing.<br />

Auto Restart<br />

<strong>Main</strong> <strong>Circuit</strong><br />

<strong>Panel</strong> <strong>with</strong><br />

<strong>Battery</strong> Backup<br />

Holding <strong>Circuit</strong><br />

<strong>Clinac</strong><br />

System<br />

Additional Emergency OFF switches<br />

available as Catalog # VEOSW<br />

Relay junction box panel is also<br />

available for <strong>Clinac</strong> 2100C as<br />

catalog # VRJB-C3.<br />

Remote Emergency Off<br />

Pushbutton, 2 included <strong>with</strong><br />

each order (Catalog # VEOSW)<br />

Wire Emergency OFF switches<br />

per <strong>Varian</strong> requirements. Use<br />

deep switchbox for each switch.<br />

UL and cUL Labeled<br />

©Copyright 2009 3 of 3 Product Data <strong>Clinac</strong> 2100CBB 7-28-2009


g OBI <strong>Circuit</strong> <strong>Breaker</strong> <strong>Panel</strong><br />

Application<br />

The On-Board Imager (OBI) <strong>Circuit</strong> breaker panel is a custom<br />

panel, which serves as the main power, disconnect between the<br />

x-ray system and the facility 480V power source. The panel<br />

provides emergency shut down and overcurrent protection for<br />

the x-ray system.<br />

The standardized design provides a platform for future<br />

upgrades of the system. The panel offers the customer and the<br />

installer a number of advantages by combining a variety of<br />

individual components into a single pre-engineered and factory<br />

tested panel. Each panel is UL and cUL listed for compliance<br />

<strong>with</strong> NEC Article 100 and Article 110-3. The main breaker<br />

panel includes a power contactor for connection and control of<br />

the <strong>Varian</strong> <strong>Clinac</strong> <strong>High</strong> <strong>Energy</strong> Accelerator system, providing<br />

immediate shut down of the OBI system to comply <strong>with</strong> NEC<br />

required disconnecting means. The panel may be surface or<br />

semi-flush mounted.<br />

Standard Applications<br />

<strong>Varian</strong> OBI - Systems in conjunction <strong>with</strong> <strong>Varian</strong> <strong>Clinac</strong> <strong>High</strong><br />

<strong>Energy</strong> Accelerators.<br />

Benefits<br />

• Developed specifically for use <strong>with</strong> <strong>Varian</strong> Oncology<br />

Systems.<br />

• Reduces installation time and cost by providing a singlepoint<br />

power connection eliminating the need to mount and<br />

wire a number of individual components.<br />

• Standardized design provides for pre-engineered system<br />

modifications such as uninterruptible power supply.<br />

• Uniform factory design eliminates individual project<br />

engineering costs, and delays of on site fabrication.<br />

• <strong>Main</strong> power contactor is coordinated to interface <strong>with</strong><br />

system emergency off.<br />

• UL and cUL listed to conform to local codes minimizing<br />

inspection and acceptance issues.<br />

• Standardized design and testing assures high product<br />

quality and system reliability.<br />

• Single panel provides for a more attractive, color<br />

coordinated installation.<br />

Features<br />

• Single panel completely assembled and tested.<br />

• Custom wiring diagram speeds installation.<br />

• UL and cUL listed to conform to NEC.<br />

• Complies <strong>with</strong> NEC Article 100 Definition of Approved<br />

and Article 110-3 Approved.<br />

• Provides low voltage, 120V controlled contactor<br />

operation.<br />

• <strong>High</strong> interrupting 25,000 amperes short circuit current<br />

rated or optional 42,000 amperes short circuit current<br />

rated to comply <strong>with</strong> available short circuit current of your<br />

installation.<br />

• Uses solid state GE Spectra molded case breakers <strong>with</strong><br />

adjustable instantaneous trip.<br />

• Padlocking provisions for OSHA lockout/tag out included<br />

on individual main breaker handle.<br />

• Cover may be locked closed <strong>with</strong> door and hasp or<br />

customer provided padlock.<br />

• ¼ turn slotted door latch provides additional security.<br />

• Isolated neutral lugs.<br />

• Oversized ground lugs for parity sizing of ground wire.<br />

• Ground bus bar for control circuit ground wires.<br />

• All devices selected for high reliability and long life.<br />

• Finger safe terminal blocks for control circuit connections.<br />

• Surface or semi-flush mounting.<br />

• Custom tailored for <strong>Varian</strong> X-ray Systems <strong>with</strong> <strong>Clinac</strong><br />

<strong>High</strong> <strong>Energy</strong> Accelerator.<br />

©Copyright 1 of 3 Product Data OBI60A480V 7/29/2009


g OBI <strong>Circuit</strong> <strong>Breaker</strong> <strong>Panel</strong><br />

OBI CIRCUIT BREAKER PANEL<br />

14.6"<br />

DEPTH 6"<br />

480V<br />

50/60 Hz<br />

24"<br />

OBI<br />

CIRCUIT<br />

BREAKER<br />

120VAC<br />

OBI<br />

SYSTEM<br />

SYSTEM<br />

EMERGENCY OFF<br />

CONTROL CIRCUIT<br />

Physical Specifications<br />

Height: 24 inches (609.6 mm)<br />

Width: 14.6 inches (370.8 mm)<br />

Depth: 6 inches (approx.) (152.4 mm)<br />

Weight: 46 pounds (21 kg)<br />

<strong>Main</strong> lug wire 3/0 max.<br />

Mounting: Via keyhole slots: width is 9.5 inches on centers.<br />

Height is 22 inches on centers (see diagram).<br />

©Copyright 2 of 3 Product Data OBI60A480V 7/29/2009


g OBI <strong>Circuit</strong> <strong>Breaker</strong> <strong>Panel</strong><br />

Conduits may enter or exit from top,<br />

bottom, sides or rear. Exact location<br />

must be field verified.<br />

4” of enclosure may be recessed in<br />

wall for semi flush installations.<br />

Products<br />

All products have provisions<br />

for 120V, 50/60 Hz control.<br />

OBI60A480V, 60 Ampere,<br />

25,000A short circuit current<br />

rating, 480V, 50/60 Hz, UL,<br />

cUL labeled, Surface or Semi-<br />

Flush mounted <strong>Panel</strong>.<br />

OBI60A480V42KAIC, 60<br />

Ampere, <strong>with</strong> optional<br />

42,000A short circuit current<br />

rating, 480V, 50/60 Hz, UL,<br />

cUL labeled, Surface or Semi-<br />

Flush mounted <strong>Panel</strong>.<br />

Available from GEXPRO<br />

National Service Center,<br />

Indianapolis, IN, Central time<br />

zone, 1-800-200-9760, X3876<br />

or 317-554-3876.<br />

©Copyright 3 of 3 Product Data OBI60A480V 7/29/2009


VRJB-C3 Relay Junction Box<br />

for <strong>Varian</strong> Medical Systems<br />

Applications<br />

The VRJB-C3 Relay Junction Box provides an interface <strong>with</strong> the <strong>Varian</strong><br />

<strong>Clinac</strong> via a factory assembled and tested control panel designed to provide<br />

a convenient, organized, labor saving central connection point for the Laser<br />

positioning system status warning lights, room lighting, and door interlocks<br />

and remote emergency off pushbuttons. The panel includes wiring diagrams<br />

to enable it to be used as a radial junction and control point simplifying the<br />

connection of the various systems. Multiple terminals are dedicated for<br />

connecting these devices. The Relay Junction box has a Short <strong>Circuit</strong><br />

Current Rating of 5,000 amperes @ 120 volts AC. The panel is UL and cUL<br />

listed and is in compliance <strong>with</strong> the NEC articles 100 and 100.3. The Relay<br />

Junction Box is designed for wall mounting.<br />

Designed for use <strong>with</strong> the following <strong>Varian</strong> Medical Systems:<br />

• 2100C/D • 21EX • Novalis Tx • iX<br />

• 2300C/D • 23EX • Trilogy<br />

• Silhouette Edition <strong>Clinac</strong><br />

Features Benefits<br />

• Dedicated terminals and multiple ground terminal<br />

bars are clearly marked <strong>with</strong> <strong>Varian</strong> drawing<br />

reference numbers.<br />

• All circuits may be connected directly to dedicated terminals,<br />

eliminating the need for additional junction boxes or multiple<br />

splices, saving installation time and labor.<br />

• Approved by <strong>Varian</strong> Medical Systems’ Engineering. • A single pre-engineered panel <strong>with</strong> a permanent wiring diagram.<br />

• Connectorized Interface Cables • Allows for verifying all of the lighting and interlock circuits<br />

prior to connection to the <strong>Varian</strong> equipment.<br />

• Surge suppression installed for each relay coil. • Provides protection for the sensitive electronic equipment.<br />

All input and output signals are protected <strong>with</strong> fuses<br />

and transient voltage suppressors.<br />

• Isolated contacts accommodate different lighting<br />

circuit voltages.<br />

• Easy mounting wall mounted enclosure utilizing<br />

(4) holes for ¼” mounting screws.<br />

Hinged door provides easy access.<br />

• Spare relay contacts are available for specialized applications.<br />

• Saves installation time and labor.<br />

Two combination ½” or ¾” combination knockouts,<br />

located on the left side.<br />

• Off white exterior paint finish.<br />

• All components selected for high reliability and long life.<br />

• Provides a standardized platform for future applications or upgrading.<br />

• UL and cUL listed.<br />

• Factory assembled and tested.<br />

• Available from Stock!


VRJB-C3 Relay Junction Box<br />

for <strong>Varian</strong> Medical Systems<br />

VARIAN RELAY<br />

JUNCTION BOX<br />

VRJB-C3


CUSTOMER POWER IN<br />

120VAC-NA, 220VAC-EUROPE (600VAC, MAX)<br />

20 AMPS MAX<br />

GND NEUTRAL LINE<br />

CUSTOMER POWER IN<br />

120VAC or 277VAC-NA, 220VAC-EUROPE (600VAC MAX)<br />

20 AMPS MAX<br />

GND NEUTRAL LINE<br />

ROOM LIGHTS<br />

(20 AMPS MAX LOAD)<br />

REMOTE EMERGENCY OFF SWITCH(S)<br />

[VARIAN SUPPLIED +24VDC]<br />

DC DOOR INTERLOCK SWITCH(S)<br />

[VARIAN SUPPLIED -12VDC OR +24VDC]<br />

NEUTRON/OPTIONAL CUSTOMER DOOR<br />

INTERLOCK SWITCH(S)<br />

[VARIAN SUPPLIED -12VDC]<br />

AC DOOR INTERLOCK SWITCH(S)<br />

[VARIAN SUPPLIED 120VAC]<br />

CUSTOMER POWER IN<br />

120VAC-NA, 220VAC-EUROPE, 20 AMPS MAX<br />

GND NEUTRAL LINE<br />

BEAM OFF LIGHT<br />

(120VAC-NA, 220VAC-EUROPE)<br />

5 AMPS MAX LOAD)<br />

BEAM ON LIGHT<br />

(120VAC-NA, 220VAC-EUROPE)<br />

5 AMPS MAX LOAD)<br />

BEAM READY LIGHT<br />

(120VAC-NA, 220VAC-EUROPE)<br />

5 AMPS MAX LOAD)<br />

GENERATOR ON LIGHT<br />

(120VAC-NA, 220VAC-EUROPE)<br />

5 AMPS MAX LOAD<br />

X-RAY ON LIGHT<br />

(120VAC-NA, 220VAC-EUROPE)<br />

5 AMPS MAX LOAD<br />

VRJB-C3 Relay Junction Box<br />

for <strong>Varian</strong> Medical Systems<br />

CUSTOMER<br />

SUPPLIED<br />

VARIAN<br />

SUPPLIED<br />

K1<br />

K2<br />

K3<br />

K4<br />

K5<br />

K6<br />

K7<br />

K1 (24VDC)<br />

K2 (24VDC)<br />

K3 (120VAC)<br />

K4 (120VAC)<br />

K5 (120VAC)<br />

K6 (24VDC)<br />

K7 (24VDC)<br />

Ordering Information:<br />

Catalog number: “<strong>Varian</strong> VRJB-C3”<br />

Available from GEXPRO, Indianapolis, Indiana<br />

1-800-200-9760, ext 3876<br />

or 1-317-554-3876<br />

INTERFACE CONNECTORS