12.07.2015 Views

Guidelines for Dance Parties - Division of Local Government - NSW ...

Guidelines for Dance Parties - Division of Local Government - NSW ...

Guidelines for Dance Parties - Division of Local Government - NSW ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Guidelines</strong> <strong>for</strong> <strong>Dance</strong> <strong>Parties</strong>DOORWAYS AND DOORSRequired exits must be fitted with swing doors which open outwards from the building. Automaticsliding doors are allowed on the main entrance but revolving doors, collapsible gates, accordiondoors, turnstiles or rigid barriers are not acceptable.Many unlicensed venues are fitted with large sliding doors and roller doors which do not meetthe requirements <strong>for</strong> places <strong>of</strong> public entertainment. However, local Councils may acceptsliding and roller doors as exits in a venue if:◆◆the doors meet the minimum requirements <strong>of</strong> distance <strong>of</strong> travel to exits and aggregatewidth, andthe doors are key-locked in the open position while the premises are occupied, and thekey is held by the promoters.Artificial LightingArtificial lighting must be provided in entertainment venues to provide a safe and com<strong>for</strong>tableenvironment in accordance with Australian Standard 1680. All rooms that will be occupied bythe public/patrons and all corridors, lobbies, internal stairways and other circulation spacesand paths <strong>of</strong> exit must be properly lit.FIRE FIGHTING EQUIPMENTFire HydrantsA fire hydrant system must be provided to service a building with a floor area greater than 500square metres, and where an operational fire service is available to attend a building fire. Firehydrants must comply with Australian Standards 2419.Hose ReelsA hose reel system must be provided to serve the whole building where one or more internalhydrants are installed.If internal hydrants are not installed, a suitable hose reel system must be provided to serve anyfire compartment with a floor area greater than 500 square metres. Hose reels must complywith Australian Standard 2441.Portable Fire ExtinguishersPortable fire extinguishers, containing the appropriate extinguishing agent <strong>for</strong> the fire risk,must be provided in every building. Water type extinguishers need not be installed in a buildingor part <strong>of</strong> a building already served by a fire hose reel.Portable fire extinguishers must be provided and installed in accordance with Australian Standard2444. Enquiries about Australian Standard 2441 and 2444, fire extinguishers and morespecialised requirements <strong>for</strong> sprinklers and alarms should be made to the local Council.34

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!