12.07.2015 Views

Sanitary Tanks

Sanitary Tanks

Sanitary Tanks

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Critical ProcessVesselsSuperiorPerformanceFor YourDemandingApplications


Saint-Gobain High-Performance VesselsWhere Quality and ToughnessCount,There’s a Saint-GobainHigh-Performance TankSaint-Gobain Performance Plastics tanksare tough. They’re lightweight andcorrosion-resistant. Their seamless designeliminates the major cause of leakageassociated with lesser quality plastictanks. Saint-Gobain Performance Plasticstanks won’t wick or crack like fiberglass.And, our tanks are easier to maintain andmuch less expensive than stainless steel.Manufactured in our ISO 9001-certifiedfacility in Reading, Pennsylvania, Saint-Gobain Performance Plastics tanks arerotationally molded in a variety ofhigh-quality virgin resin materials tomatch your specific application.Reliability andToughness ExpandedSaint-Gobain Performance Plastics alsooffers high-quality blowers, safety equipment,fittings and accessories. Like ourtanks, they feature the quality, reliabilityand toughness you’ve come to expectfrom Saint-Gobain.Service and Support—We’re Here When You Need UsSaint-Gobain Performance Plastics offersfree technical assistance and a knowledgeablenetwork of sales representativescommitted to your complete satisfaction.We’ll help you select the rightSaint-Gobain Performance Plasticsproduct for your specific requirements.We’ll educate, inform and demonstratethe advantages our tanks offer over othercompetitive containers. And with ourexclusive warranty, we’ll supply you witha reliable system that will last and last.Saint-Gobain Performance Plastics Rotational-Molded <strong>Tanks</strong> Offer Distinct AdvantagesService Depends onContents, Location, Temperatureand Other Conditions• Lower cost than stainless steel orfiberglass• Virtually maintenance-free• Seamless construction for easy cleaning• Available in a wide variety of resinsand leakproof service• Most tanks have a visible liquid level• Controlled wall thickness withoutcorner thinning• Lightweight; less than one-half theweight of steelPlastic tanks which are subject to chemical,physical and/or thermal exposureshould be inspected on a routine basisfor any signs of leaking, cracking, discoloration,bulging or other deviations fromthe “as new” condition. The frequency ofinspection will be highly dependent uponactual use conditions, as well as the ageof the tank. Specific guidelines must bedetermined by the user dependent uponactual use conditions. Saint-Gobain cannotprovide specific guidelines due to thewide variety of applications and theireffects on plastic tanks. Please consultthis catalog or contact Saint-GobainPerformance Plastics for more information.Quality Design AssuresLong, Reliable LifeOur tanks feature generous, roundedcorners that have less molded-in stress.This construction makes them less likelyto crack and easier to clean.Special Notes• <strong>Tanks</strong> with Fiberglass-ReinforcedPolyester (FRP) Casings offer service tohigher temperatures and with higherspecific gravity contents.• Operating conditions and chemicalusage can decrease maximum servicetemperatures.• Continuous service temperatures inranges above ambient can affecttanks in at least two ways: 1) the usefullife of the tank may be shortened;and 2) the ability of the container tomaintain its shape may decrease,perhaps resulting in distortion.Other <strong>Tanks</strong>Saint-GobainHigh-Performance Vessels


I N T R O D U C T I O NTable of ContentsBy Catalog Number SeriesBy Product and SubjectCat. No. Page Cat. No. Page Cat. No. PageIntroduction and Information <strong>Sanitary</strong> Vessels2624 192650 192653 222654 222656 262658 262660 242661 242662 252663 252665 252666 252669 252670 242671 242672 242673 232674 232677 272678 272680 272681 272685 252690 202691 202692 242695 232696 232697 232710 212711 2111100 411102 411150 811200 411250 811300 411500 412000 712300 714100 714150 614200 714250 614300 714350 614500 715000 716120 516220 516320 516520 517000 517109 917110 918100 418200 418300 419000 419009 919010 920010 948080 1348090 1354100 454102 454104 1156104 863100 1063600 1071300 3571309 3471320 32, 3571330 32, 3571400 3571409 3471420 32, 3571430 32, 3571500 3571509 3471520 32, 3571530 32, 35716421 13716422 1372509 3472510 3672511 3672520 3372521 32-3572530 33-35ISO-9001 Registration72531 32-3572609 3472620 33-3572621 32-3572629 3472630 33-3572631 32-3572721 32-3572730 34-3572731 32-3572821 3272830 34-3572831 32-3576000 1387001 1387005 1287006 1287500 1188001 1389005 1293400 1293420 1393840 1293841 1293857 1293858 1293859 1295840 1295857 1296000 1396423 1297001 1397003 1397006 1397103 1397424 1398001 1398003 1398103 13The products in this catalog are manufacturedin compliance with ISO-9001 quality requirements.Items in this catalog that are not manufacturedin an ISO-certified facility are indicated with abold typeface in the index by Catalog NumberSeries (above).How to Select YourHigh-Performance Tank. . . . . . . . . . . . . . 2Technical Information . . . . . . . . . . . . . .37Food Grade Resins, Plastic Products forBiotechnology, Dimensions and WallThickness, Physical Service Capabilities,Environmental Stress-Cracking, TensileStresses, Common Stress-CrackingAgents, Susceptibility to Stress-Cracking,Physical Service Capabilities,Ultraviolet (UV) StabilizationChemical Storage . . . . . . . . . . . . . . . . . .38Storage of Sodium Hypochlorite,Using <strong>Tanks</strong> with Common ChemicalsChemical Resistance Charts . . . . .39-44Warranty and How to Order . . . . . . . . .45Open-Top <strong>Tanks</strong>General Guide to Open-Top <strong>Tanks</strong> . . . . 3Flat-Bottom Cylindrical <strong>Tanks</strong> . . . . . . . . 4Conical-Bottom <strong>Tanks</strong> . . . . . . . . . . . . . . . 5Rectangular <strong>Tanks</strong>. . . . . . . . . . . . . . . . . 6-7Tank Flange Styles, <strong>Tanks</strong> WithFlat Wide Flanges, Flat-FlangeRectangular <strong>Tanks</strong>Cylindrical <strong>Tanks</strong> . . . . . . . . . . . . . . . . . . . . 8Tapered General Purpose Containers,Closed-Dome <strong>Tanks</strong>Cylindrical Tank Stands . . . . . . . . . . . . . . 9Floor Stands, Elevated Stands forFlat-Bottom and Conical-Bottom<strong>Tanks</strong>, OptionsOpen-Top Tank Mixers . . . . . . . . . . . . . . 10LIGHTNIN Mixer Features, OptionsOpen-Top TankFittings/Accessories . . . . . . . . . . . . . . 11-13Floating Covers, Installed Hinges forCylindrical Tank Covers, Installed andLoose Fittings, Bulkhead FittingsGuidelines for Installation. . . . . . . . 14-16Putting It All Together . . . . . . . . . . . . . . 17<strong>Sanitary</strong> <strong>Tanks</strong> . . . . . . . . . . . . . . . . . . . . . 18Closed-Dome Bio <strong>Tanks</strong> . . . . . . . . . . . . . 19Closed-Dome Bio Tank Accessories<strong>Sanitary</strong> Conical Process Vessels. . . . . 20Processing Tank Systems,Conical-Bottom Processing <strong>Tanks</strong>:Polypropylene and PolypropyleneFluoride<strong>Sanitary</strong> Conical Tank Stands . . . . . . . . 21Conical-Bottom Portable Tank Stands,Industrial-Style Stand Option<strong>Sanitary</strong> Tank Mixers . . . . . . . . . . . . . . . 22BioTech Mixing Systems,BioTech Mixer Overhead Drives,Lower Assemblies/Shafts and Impellers<strong>Sanitary</strong> Drain Options . . . . . . . . . . . . . 23Conical Drain Valve,Diaphragm Valve, Ball Valve<strong>Sanitary</strong> Fittings andAccessories . . . . . . . . . . . . . . . . . . . . . 24-27Installed <strong>Sanitary</strong> Ferrules,<strong>Sanitary</strong> Gaskets, True Union Clamps,End Caps, Sight Caps, Elbow Sweeps,Concentric Reducers, Heavy-DutyClamps, Siphon Tubes, Rotary Spray Jet,Mounting Apparatus for Spray JetNozzle, Sani-Sampling Devices,1-inch Ladish Charging ElbowProper Placement andAutoclave Instructions . . . . . . . . . . . . . 28Putting It All Together. . . . . . . . . . . . . . 29BlowersBlowers Introduction. . . . . . . . . . . . . . . 30Four Steps to Blower Selection . . . . . . 31Blower Specifications . . . . . . . . . . . 32-361


I N T R O D U C T I O NHow To Select Your High-Performance TankTank Resin Selection Guide — Typical Properties and Applications 1Material General Chemical Stress-Crack 2 Maximum Service Brittleness Impact Can Be Welded Food-Grade ColorRESIN Resistance Resistance Temperature Temperature Resistance 3 (Hot Gas) AcceptabilityNATURAL, UNPIGMENTED NATURAL, UNPIGMENTEDHDPEHigh DensityPolyethyleneVery GoodGood140°F60°C-94°F-70°CGoodYesYes 4Naturaland BlackWhiteXLPECross-LinkedHigh DensityPolyethyleneVery GoodExcellent140°F60°C-180°F-118°CExcellentNoNoYellowPPPolypropyleneVery GoodExcellent220°F104°C32°F0°CFairYesYes 4Off-WhitePVDFPolyvinylideneFluorideExcellentExcellent230°F110°C-40°F-40°CFairYesYes 4Off-WhiteTank Resin Selection Guide — (continued)Material ADVANTAGES AND APPLICATIONS DO NOT USE WITH:RESINHDPEHigh DensityPolyethylene•Hard, smooth finish•Good temperatureresistance•Less expensive than stainlesssteel or fiberglass•Storing caustics•Metal finishing•Storing organic andinorganic acids•Water treatment•Dispensing lab andphoto chemicals•Plating•BrineStrong oxidizing agents,aromatic hydrocarbons,halogenated-aliphatic hydrocarbons,liquefied petroleum gas, solventsXLPECross-LinkedHigh DensityPolyethylene•Suitable for many corrosivesnot handled by FRP•Storing corrosives, includingsulfuric, hydrochloricand hydrofluoric acids•Storing sodium hypochlorite(See statementon page 38)•Storing organic andinorganic chemicals andcompounds•Chemical processing•Storing boiler treatmentchemicals•Water and wastewatertreatmentStrong oxidizing agents,aromatic hydrocarbons,halogenated-aliphatic hydrocarbons,liquefied petroleum gas, solventsPPPolypropylene•Good resistance to manyorganic chemicals•Less expensive thancomparable stainlesssteel tanks•Weldable PP fittingsavailable•Plating and pickling lines•<strong>Sanitary</strong> process tanks•Etch tanks for processingsilicone wafersStrong oxidizing agents;aromatic or chlorinated hydrocarbons,sub-freezing temperaturesPVDFPolyvinylideneFluoride•Superior resistance toinorganic acids, strongoxidizing agents andhalogenated compounds•High-purity; does notcontaminate process fluids•PVDF Schedule 80 threadedfittings available•Etch tanks for processingsilicone wafers•Ultra-pure water storage(not potable)•Precious metal recovery•Storing and processinghalogenated compounds(i.e., bromine)•Storing bleach andsulfuric acid for pulpand paper processing•Industrial battery casings•Insecticide manufacturingKetones, esters and hot,concentrated caustics; nascentchlorine gas and concentratedcaustic soda2NOTES:1 At low temperatures, protect all tanks from impact. Below 40°F/4°C, specify XLPE <strong>Tanks</strong>.2 Cross-linked, high-density polyethylene is recommended for use with stress-cracking agents.3 Brittleness temperature per ASTM test D-746. The impact resistance of most rotomolded tanks declines at freezing temperatures.Cross-linked, high-density polyethylene tanks are well suited for cold storage.4 The resins used in Saint-Gobain Performance Plastics linear low- and high-density polyethylene and polypropylene tanks comply with 21 CFRRegulation 177.1520.Polyethylene meets all food-grade requirements; however, this product is restricted to contacting food only of the types identified in21 CFR 176.170 Table 1, under categories 1, IV-B, VII-B, VIII, and under conditions of use B through H described in Table 2 of 21 CFR 176.170. Saint-Gobainrotomolded polypropylene complies with FDA 21 CFR 177.1520 (c) 3.1 regulation. The resin used in PVDF tanks complies with 21 CFR 177.2510.5 Open-top tanks do not contain UV stabilizer; black is recommended for certain applications. Bulk tanks are UV-stabilized and may be used outdoors.


O P E N - T O P T A N K SGeneral Guide to Open-Top <strong>Tanks</strong>Plastic <strong>Tanks</strong> For High-Purity StorageSaint-Gobain Performance Plasticshigh-performance tanks are the best andtoughest in the industry. Exacting CADbaseddesigns, the highest quality virginresins and tough construction provideexcellent solutions for general purposeapplications. The tanks are translucentand feature molded-in graduations.Each tank comes with a matching coverthe same thickness as the wall. Theopen-top unit covers fit like a shoe box;bolted or welded covers are availableupon request.Closed-dome tanks are availablefor applications requiring a completelyclosed vessel. The 6" threadedpolypropylene covers prevent evaporationand spills.Our open-top tanks are rated for usewith 1.8 specific gravity media. If afiberglass casing is used, the rating goesup to 2.2.Casings provide structuralsupport and prevent bulging at the bottomof the tank. They should be usedwith rectangular units with any dimensiongreater than 18 inches. Casings arealso required for use with media havinga specific gravity greater than 1.8 or foruse at prolonged elevated temperatures.Our stands, mixers, and casings havebeen pre-engineered for compatibility.Simply choose your tank size and thesize codes of the accessories will match.Fabrication is available for allSaint-Gobain Performance Plasticstanks. Modifications can be made to thecovers or the sides. Contact customerservice for quotations. Welded andmechanical fittings can be installed,as well as a full line of accessories.Materials OverviewHigh DensityPolyethylene (HDPE):• FDA 21 CFR 177.1520• Hard, Smooth Finish• Very Good Chemical Resistance• Good Stress-Crack Resistance• Max Service Temp—140°F• Translucent WhitePolypropylene (PP):Cross-LinkedPolyethylene (XLPE):• Not FDA• Cannot be welded• Better Chemical Resistance to HDPE• Excellent Stress-Crack Resistance• Max Service Temp—140°F• Yellow (Bulk <strong>Tanks</strong>—Gray)PolyvinylideneFluoride (PVDF):Structural DesignsCylindrical tanks feature a stepped-flangedesign that adds rigidity and strengthwhile helping to contain drips. <strong>Tanks</strong> over30 gallons feature a slightly raised bottomthat channels liquids to tank walls andfittings. Spoked bottoms reinforce largertanks over 55 gallons and providenear-total drainage.• FDA 21 CFR 177.1520• USP Class VI, Non-cytotoxic• Hard, Smooth Finish• Very Good Chemical Resistance• Excellent Stress-Crack Resistance• Max Service Temp—220°F• White• FDA 21 CFR 177.2510• High-Purity Material/Low Extractables• Larger sizes require casings• Inherent UV Resistance• Excellent Chemical Resistance• Max Service Temp—230°F• Off-WhiteSTEPPED-FLANGEUP TO 30 GALLONRAISED BOTTOMMaximum service temperature listings refer to temperatures that should not be exceeded for thematerials utilized in the specific product line. Many factors including media, specific gravity ofmedia, external stresses, product geometry, environment, and others affect suitability of material.55 AND 80 GALLONSPOKED BOTTOM100 GALLON AND ABOVESPOKED BOTTOM3


O P E N - T O P T A N K SFlat-Bottom Cylindrical <strong>Tanks</strong>Flat-Bottom Cylindrical <strong>Tanks</strong>• All tankscome withcovers• BrimcapacitySTEPPED-FLANGE1000-GALLON COVER10% over WARNING: Never use FRP casings alone asa tank. Always use a liner. For continuousservice at elevated temperatures or storageof high specific-gravity materials, always usean FRP casing with your tank.CAT. NO. 11100 CAT. NO. 11102 CAT. NO. 11300Nominal Wall Thickness By ResinHDPE, Heavyweight(Avail. in Black,No. 18100)HDPE,LightweightXLPE,Heavyweight(Avail. inBlack,No. 18300)PP,Heavyweight(Avail. inBlack,No. 18200)PVDF(Avail. inBlack,No. 18200)Approx. Shipping(wt., lbs.)Size Size Grad. Nom. Tank Natural w/ Spigot Natural Natural Natural Natural Natural Tank w/Casing(gallons) Code (gal./liter) Dimensions Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No.(O.D. x Depth, in.) 11100 11102** 54100 54102 11300 11200 11500 Light Heavy 19000(CASING DIM.)5 -0005 0.5/2 11 x 15—3/16 3/16 3/32 3/32 3/16 3/16 3/32 4-1/2 † 5 † N/A7.5 -0007 0.5/* 12 x 18—3/16 3/16 3/32 3/32 3/16 3/16 N/A 6-1/2 † 7-1/2 † N/A10 -0010 1/* 13 x 20—3/16 3/16 3/32 3/32 3/16 3/16 3/32 6-1/2 † 9 † N/A15 -0015 1/4 13 x 27—3/16 3/16 3/32 3/32 3/16 3/16 3/32 8 † 11-1/2 † N/A30 -0030 2.5/10 18 x 30 3/16 3/16 3/32 3/32 3/16 3/16 3/32 12 † 19 † 42 †19-1/8 x 30-1/455 -0055 2.5/10 22 x 36 1/4 1/4 3/32 3/32 1/4 1/4 1/8 20-1/2 † 31 5323 x 36-1/480 -0080 5/20 24 x 48 1/4 N/A N/A N/A 1/4 1/4 1/8** N/A 50 8024-3/4 x 48-1/4100 -0100 5/20 28 x 44 1/4 N/A N/A N/A 1/4 1/4 1/8** N/A 50 8029-3/16 x 44-1/4150 -0150 10/40 31 x 49 1/4 N/A N/A N/A 1/4 1/4 1/8** N/A 60 13532-7/16 x 49-1/4200 -0200 25/200 36 x 51 1/4 N/A N/A N/A 1/4 1/4 1/8** N/A 67-1/2 15037-1/2 x 51-1/4275 -0275 25/100 42 x 49 1/4 N/A N/A N/A 1/4 1/4 1/8** N/A 101 20043-1/2 x 49-1/4360 -0360 25/100 48 x 49 1/4 N/A N/A N/A 1/4 1/4 N/A N/A 120 29648-3/8 x 49-1/4500 -0500 25/100 53 x 62 5/16 N/A N/A N/A 5/16 N/A N/A N/A 150 30054-1/8 x 62-1/41,000 -1000 50/250 66 x 72 7/16 N/A N/A N/A 7/16 N/A N/A N/A 389 50067-1/2 x 72-1/4Maximum Service Temperature140°F60°C140°F60°C140°F60°C220°F104°C230°F110°C4*7.5- and 10-gallon cylindrical tanks do not have liter calibrations **Casing required For replacement spigot, see page 13†Within UPS size restrictions ††These sizes quoted on request N/A=Not AvailableMaximum service temperature listings refer to temperatures that should not be exceeded for the materials utilized in the specific product line.Many factors, such as chemical resistance, specific gravity, external stresses, product geometry, environment and many others affect the suitabilityof a particular product. For additional information, contact Saint-Gobain Performance Plastics.


O P E N - T O P T A N K SConical-Bottom <strong>Tanks</strong>Conical-Bottom <strong>Tanks</strong>• 30° cone angle (18° for 400 gallons,45° for 500 gallons)• Complete drainage• Better dispersal of solids• Easy installation of welded orbulkhead fittings• HDPE and polypropylene resinscomply with 21 CFR Reg. 177.1520(Refer to chart on page 3)PVDF 21 CFR 177.2510• Require metal stands (see page 9)• Clearance from the floor to bottomof the tank is 18 inches (12 inches on10-gallon tank)WARNING: Never use FRP casings alone asa tank. Always use a liner. Always use an FRPcasing with your tank for continuous serviceat elevated temperatures, or storage of highspecific-gravity materials.CAT. NO. 16120Conical-Bottom Cylindrical <strong>Tanks</strong> — Nominal Wall Thickness By ResinHDPEXLPE PP PVDF CasingApprox. ShippingSize Size Grad. Nom./Dim. Bottom Natural Cat. Natural Cat. Natural Cat. Natural Cat. (wt., lbs. (wt., lbs. Tank(gallons) Code (gal./liter) (O.D. x Depth*) Flat Dia. No. 16120 No. 16320 No. 16220 No. 16520 17000 Tank) w/ Casing)10-00101/513-1/4 x 2335/325/325/323/32N/A10†N/A30-00302.5/1018 x 3533/163/163/163/323/32183755-00552.5/1022 x 4433/163/163/161/83/163453100-01005/2032 x 3851/41/41/41/83/164895150-01505/2032 x 5751/41/41/41/8**3/1682150250-025025/10043 x 5455/165/165/161/8**3/16112241400-040025/10056 x 5273/83/83/8N/A1/4140230500-050025/10053 x 8075/165/16N/AN/A1/4215331Maximum Service Temperature140°F60°C140°F60°C220°F104°C230°F110°C*To cone flat N/A = Not Available**Casing required†Within UPS size restrictionsCone Angles: 30° on 10, 30, 55, 100, 150, 250 gallon18° on 400 gallon & 45° on 500 gallon5


O P E N - T O P T A N K SRectangular <strong>Tanks</strong>A Complete Line of Rectangular Plastic <strong>Tanks</strong> from 2 to 500 GallonsUsed in Many ApplicationsChoice of Four Premium ResinsSaint-Gobain Performance Plasticsrectangular tanks have proven reliablein many demanding applications:• Plating• Etching• Silicon wafer processing• Circuit board production• Photofinishing• Food handling (except XLPE)• Dry cleaning• Metal parts degreasing• Chemical processing• Wastewater treatment• Photographic applicationsOur rectangular tanks are available infour premium resins: HDPE, XLPE, PPand PVDF. More than 50 configurationsand three flange styles are offered. Allrectangular tanks are rotationally moldedin one piece. There are no fabricatedseams that are prone to stress-crackingand failure. Molded tanks cost less thanfabricated plastic tanks or stainless steeltanks of the same size. All rectangulartanks are supplied with cover.These tanks offer a broad range ofresistance to chemicals, stress-cracking,impact and abrasion, depending on theresin. (See the Tank Resin SelectionGuide.) A wide variety of welded andbulkhead-style fittings are available(see pages 12-13).FRP (fiberglass-reinforced polyester) supportcasings are available for Saint-Gobainrectangular tanks. These casings aresteel-reinforced, chemical-resistant andmaintenance-free. Saint-GobainPerformance Plastics recommends usingFRP casing or exterior support with allrectangular tanks used at elevated temperatures,with high specific gravity liquidsor a dimension greater than 18 inches.NOTE: Maximum service temperaturelistings refer to temperatures that should notbe exceeded for the materials utilized in thespecific product line. Many factors, such aschemical resistance, specific gravity, externalstresses, product geometry, environmentand many others affect the suitability of aparticular product. For additional information,contact Saint-Gobain Performance Plastics.Tank Flange Styles AvailableStepped-Flange• Stock tank comes with standarddust cover only; cover, bolts andgasket custom quoteSTEPPED-FLANGESTEPPED-FLANGEWITH 1/2" FLATFLAT-FLANGE• Easy mounting of small accessories• Better drip containment of partsthat are dippedStepped-Flange With 1/2" Flat• To secure equipment support coversFlat-Flange• Often used in plating operations• When ordered with FRP supportcasings, each tank can support upto 300 lbs. (i.e., plating rods)<strong>Tanks</strong> With Flat Wide FlangeHDPE PP XLPE CasingNominal Interior Dimensions Size Stand Size Cat. No. Cat. No. Cat. No. Cat. No. Approx. Shipping (wt., lbs.)Inches, L x W x Depth (gallons) Code 14150 14250 14350 15000 Tank w/ Casing24 x 12 x 1224 x 18 x 181530-0020-00455/325/321/41/45/325/323/163/1613 †3320 † 356*Casing recommended†Within UPS size restrictionsMaximum Service Temperature140°F60°C220°F104°C140°F60°C


O P E N - T O P T A N K SRectangular <strong>Tanks</strong>Rectangular <strong>Tanks</strong> — Nominal Wall Thickness By ResinHDPE XLPE PP PVDF HDPE XLPE CasingNominal Interior Dimensions Size Stand Size Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Approx. Shipping (wt., lbs.)Inches, L x W x Depth (gallons) Code 14100 14300 14200 14500 12000 12300 15000 Tank w/ CasingFLAT FLANGE FLAT FLANGE THICKNESS8 x 8 x 82 -0002 5/32 5/32 3/16 3/32 — — 3/16 4 †1014 x 10 x 106 -0005 5/32 5/32 3/16 3/32 — — 3/16 7 †1612 x 12 x 127 -0010 5/32 5/32 3/16 3/32 — — 3/16 8 †1518 x 12 x 1211 -0015 5/32 5/32 3/16 1/8 — — 3/16 10 †2224 x 12 x 12 * 15 -0020 5/32 5/32 3/16 1/8 — — 3/16 13 †3324 x 24 x 12 * 30 -0021 5/32 5/32 3/16 1/8 — — 3/16 19 †7830 x 30 x 12 * 47 -0022 5/32 5/32 1/4 N/A — — 3/16 326730 x 24 x 12 * 30 -0006 — — — — 7/32 7/32 3/16 35 †5748 x 24 x 12 * 50 -0011 — — — — 7/32 7/32 3/16 497118 x 4 x 186 -0030 5/32 5/32 3/16 N/A — — 3/16 8 †2012 x 12 x 1811 -0035 5/32 5/32 3/16 N/A — — 3/16 11 †2018 x 12 x 1815 -0040 5/32 5/32 3/16 1/8 — — 3/16 13 †2618 x 18 x 18 25 -0042 5/32 5/32 1/4 N/A — — 3/16 18 †3624 x 12 x 18 * 22 -0043 5/32 5/32 1/4 N/A — — 3/16 17 †4424 x 18 x 18 * 30 -0045 5/32 5/32 1/4 1/8 — — 3/16 25 †3530 x 24 x 18 * 50 -0016 — — — — 7/32 7/32 3/16 385848 x 24 x 18 * 75 -0023 — — — — 7/32 7/32 3/16 50-1/2 7836 x 20 x 20 * 60 -0050 5/32 3/16 1/4 1/8 — — 3/16 417618 x 4 x 24 * 22 -0060 5/32 5/32 1/4 1/8 — — 3/16 15 †4112 x 12 x 24 * 30 -0062 5/32 5/32 1/4 N/A — — 3/16 19 †5218 x 12 x 24 * 45 -0065 5/32 5/32 1/4 1/8 — — 3/16 246518 x 18 x 24 * 94 -0066 3/16 3/16 5/16 N/A — — 3/16 468524 x 12 x 24 * 90 -0070 3/16 3/16 1/4 N/A — — 3/16 456824 x 24 x 24 * 60 -0025 — — — — 7/32 7/32 3/16 428230 x 24 x 24 * 70 -0031 — — — — 7/32 7/32 3/16 438848 x 24 x 24 * 105 -0036 — — — — 7/32 7/32 3/16 6211924 x 4 x 30 * 12 -0075 1/8 1/8 3/16 N/A — — 3/16 17 †2524 x 8 x 30 * 25 -0080 1/8 1/8 3/16 N/A — — 3/16 18 †3030 x 30 x 30 * 117 -0081 3/16 3/16 5/16 N/A — — 3/16 479818 x 18 x 30 * 40 -0041 — — — — 7/32 7/32 3/16 297124 x 18 x 30 * 55 -0046 — — — — 7/32 7/32 3/16 418430 x 24 x 30 * 85 -0051 — — — — 7/32 7/32 3/16 53-1/2 10430 x 30 x 30 * 115 -0055 — — — — 7/32 7/32 3/16 6011948 x 24 x 30 * 135 -0061 — — — — 7/32 7/32 3/16 7213844 x 36 x 33 ** 220 -0067 †† — — — — 5/16 5/16 3/16 120 16550 x 36 x 33 ** 250 -0071 †† — — — — 5/16 5/16 3/16 13821324 x 24 x 36 * 90 -0090 3/16 3/16 1/4 N/A — — 3/16 458030 x 30 x 36 * 140 -0091 3/16 3/16 5/16 N/A — — 3/16 5013530 x 24 x 36 * 105 -0076 — — — — 7/32 7/32 3/16 6512236 x 36 x 36 * 185 -0082 — — — — 7/32 7/32 3/16 9821648 x 24 x 36 * 160 -0085 — — — — 7/32 7/32 3/16 7619048 x 36 x 36 ** 260 -0087 †† — — — — 5/16 5/16 3/16 153 26360 x 24 x 36 ** 210 -0092 †† — — — — 5/16 5/16 3/16 15722272 x 36 x 36 ** 375 -0095 †† — — — — 5/16 5/16 3/16 194 30930 x 24 x 48 * 140 -0100 — — — — 7/32 7/32 3/16 7316248 x 24 x 48 ** 220 -0105 — — — — 7/32 7/32 3/16 9317372 x 36 x 48 ** 500 -0110 †† — — — — 5/16 5/16 3/16 186 386Maximum Service Temperature*Casing recommended†Within UPS size restrictions140°F60°C140°F60°C220°F104°C230°F110°C140°F60°C140°F60°C**Casing required††Covers on these tanks are ribbed for structural support. Cross support cannot be cut for hinge installation.7


O P E N - T O P T A N K SCylindrical <strong>Tanks</strong>Tapered General Purpose ContainersTaperedGeneral PurposeContainer—HDPE• Straight, no-lip flange• Often used in watertreatment• Rigid and lightweight• Fits through standarddoor for portabilitySize Size Grad. Nom./Dim. Natural Cat. Approx. Shipping(gallons) Code (gallons) (O.D. x Depth) No. 56104 (wt., lbs.)30505 per package.-0030-00505522 x 22-1/222 x 38-7/83/323/325580CAT. NO. 56104Closed-Dome <strong>Tanks</strong>Closed-Dome <strong>Tanks</strong>• 6" threaded screwclosure with siliconegasket• 2-inch top bungwith buttress threadon HDPE, 2-inchNPS on PP• Protects contents from contaminationand spillage• Reduces evaporation• Two mounting flats• Domed bottom offers good drainage• Graduations in gallons and litersAccessories and Options• Viton closure gasket #620409-0005• EPDM gasket 311-1509• Metal stand elevates tanks22 inches from floor—Cat. No. 19009(see page 9)• Many fittings available (see pages 12-13)CAT. NO. 11150Closed-Dome <strong>Tanks</strong> — Nominal Wall Thickness By ResinSize Size Grad. Nom./Dim. Natural Cat. Natural Cat. Approximate Shipping(gallons) Code (gal./liter) (O.D. x Depth) No. 11150 No. 11250 (wt., lbs.)HDPEPP20*-00201.25/516-1/2 x 321/4N/A17 †30-00302.5/1018-1/2 x 38-5/83/161/420 †55-00552.5/1022 x 43-1/81/41/431100-010010 /5028-1/2 x 51-1/41/45/1660*Flat sides 180° for fitting placement. No flat on top.†Within UPS size restrictionsFor stainless steel dolly, see page 19.8


O P E N - T O P T A N K SCylindrical Tank StandsTank StandsSturdy, all-metal stands are available formost Saint-Gobain Performance Plasticscylindrical tanks. These stands feature:• Welded carbon steel construction• Chemical-resistant PUR Paint• Fit tanks with or without FRP casingElevated Stands forConical-Bottom <strong>Tanks</strong>• Conform to the tank’s cone angle• Open at tip to accommodate fittings• Conical-bottom stands center drainopenings are as follows:AFloor Stands• Used with flat-bottom tanks• Elevate the mixer to correct height• Stand partially encircles the tank• Should be bolted to the floor for stabilityElevated Stands forFlat-Bottom <strong>Tanks</strong>• Lift flat-bottom tanks 22 inches• 8-inch center hole for drain• 5.5-inch rim cut-out for low side fittings• Stand should be bolted to the floor• Available with or without mixer supports30 gallon—5 inch;55, 100, 150 and 250 gallon—7 inch;400 and 500 gallon—8 inch• Cone tip 18 inches from the floor• Stand should be bolted to the floor• Available with or withoutmixer supportsOptions• Casters (S/S or sanitary)• 304 or 316 S/S construction• Handles and support ring formobile standsFLOOR STAND FORFLAT-BOTTOMTANK STAND CAT. NO. 20010(UP TO 1000 GALLONS)NOTE: Plastic tankscannot support theweight of a mixer or otherequipment. They must beattached to the stand’smetal support. NEVERclamp equipment directlyto a plastic tank.ELEVATED FLAT-BOTTOM TANKSTAND CAT. NOS. 19009 AND 19010(UP TO 1000 GALLONS)ABBCTank Stands — Nominal Dimensions, InchesFloor StandsFlat-BottomElevated StandsConical-BottomStand Shipping (wt., lbs.)Size Stand Size Flat-Bottom Cat. Cat. No. 19009 Cat. No. 19010 Cat. No. 17109 Cat. No. 17110 Floor Elevated(gallons) Code No. 20010 (w/ Support) A B C (w/ support) A B C (w/ support)SUPPORT HEIGHT10 -0010N/AN/A N/A N/A 12 3-1/2 N/AN/A 253055801001502002502753604005001000-0030-0055-080-0100-0150-0200-0250-0275-0360-0400-0500-1000353848444951N/A4949N/A6277222222222222N/A2222N/A22223-1/23-1/23-1/23-1/23-1/23-1/2N/A3-1/23-1/2N/A3-1/23-1/2For dimensions of floor pads and bolt holes, contact Saint-Gobain Performance Plastics.576173687373N/A7373N/A841001818N/A1818N/A18N/AN/A1818N/A3-1/23-1/2N/A3-1/23-1/2N/A3-1/2N/AN/A3-1/29-1/2N/A56-1/263N/A6478N/A74N/AN/A73105N/A17-1/2202327-1/22932-1/2N/A3236N/A4352-1/2ELEVATED CONICAL-BOTTOM TANKSTAND CAT. NOS. 17109 AND 17110(UP TO 500 GALLONS)85951051251351501581822152652753259


O P E N - T O P T A N K SOpen-Top Tank MixersSaint-Gobain Performance Plastics <strong>Tanks</strong> and LIGHTNIN MixersLIGHTNIN MIXEROur pre-engineeredpackages are available forgeneral mixing/mediumagitation of up to 1000gallons.Saint-Gobain PerformancePlastics tank and mixerpackages are designedfor liquids and liquidslurries only. We do notwarrant these packagesfor any specific application;only generalpurpose mixing tothese maximum limits:• Solids—20% by weight• Specific Gravity (batch)—1.2• Viscosity—500 centipoiseLIGHTNIN Mixer Features• Self-aligning, floating gears optimizeload sharing and reduce wear• Switch cord and plug are standardon single-phase units• Oversized bearings for superiorshaft support• 115-volt, single-phase motors• Standard 1-year warranty• Permanently sealed lubrication• Motors—Precision-matched toLIGHTNIN mixers. Direct drive or geardrive, depending on tank size. Chemicalresistanthousings, 1/4–1/2 hp. Preengineeredto applicable Saint-Gobaintanks and stands. Totally enclosed.• Mounts—LIGHTNIN mixers clampsecurely to steel support stands.• Mixer Supports— Welded steel withchemical-resistant polyurethanepaint. Pre-sized for proper mixerelevation. Integral part of stand forsecurity and rigidity.• Impellers—Cast 316 stainless steelimpellers are supplied on all mixers.Mixer packages are supplied with oneimpeller.• Shafts—All shafts are concentric,centerless ground, stainless steel.Available Options• Explosion-proof motors• LIGHTNIN mixers can be suppliedwith air motors for use in flammableor explosion-proof environment.• Air motors operate using compressedair and require no electricity.These mixers provide an inherentvariable-speed feature by merelyadjusting your air-control valve andcannot overload• Tachometers for mixers largerthan 55 gallons• Special PVDF and PTFE shafts andimpeller coatingsWARNING: Never clamp a mixer directly toa plastic tank. Always attach the mixer to aseparate metal support. Directly attaching amixer to a plastic tank will void all productwarranties. Never position impeller closer than3 inches from tank wall.Flat-Bottom and Conical-Bottom <strong>Tanks</strong> with Mixers10FLAT-BOTTOMTank Size Size Mixer Drive Horse Impeller Shaft Impeller Mixer Tank, Stand and Mixer(gallons) Code Power RPM D x L, in. Dia., in. Height, In. Approx. Shipping(wt., lbs.)3055801001502002753605001000-0030-0055-0080-0100-0150-0200-0275-0360-0500-1000CONICAL-BOTTOM103055100150250400500-0010-0030-0055-0100-0150-0250-0400-0500DirectDirectDirectDirectDirectGearGearGearGearGearN/ADirectDirectDirectGearGearGearGear1/41/41/41/41/41/41/41/41/41/2N/A1/41/41/41/41/41/41/417501750175017501750350350280280280N/A172517251725350350350280NOTE: Add mixer height to agitator support dimension (page 8) for overall height.Mixers, Cat. No. 631000.63 x 360.63 x 360.63 x 480.63 x 480.63 x 480.75 x 480.75 x 480.75 x 480.75 x 600.75 x 70Mixers, Cat. No. 63600N/A0.63 x 360.63 x 360.63 x 420.75 x 540.75 x 480.75 x 500.75 x 703.63.63.63.63.611.211.213.613.615.1N/A3.63.63.611.28.911.212.8131325-1/225-1/225-1/229-1/429-1/429-1/429-1/429-1/4N/A131325-1/219-1/829-1/429-1/429-1/42002152702853504405355807501000N/A170210285359500540650


O P E N - T O P T A N K SOpen-Top Tank Fittings/AccessoriesCoversFloating CoversMaintain continuous contact as liquidlevel changes; reduce evaporation,fumes and surface oxidation. Verygood chemical resistance. Fit onlySaint-Gobain Performance Plasticsstraight-wall cylindrical tanks (Series11000, 18000, 19000 and 54000). Resincomplies with 21 CFR Reg. 177.1520.Refer to chart on page 2.Installed Hinges forSaint-Gobain PerformancePlastics High-PerformanceCylindrical Tank CoversFlexible PP hinge provides access tocylindrical tanks without completelyremoving cover. The cover is cut to yourspecifications. The hinge is installedwith stainless steel rivets. Hinge lengthand exact location must be listed separatelyon your purchase order.Stainless steel hingesavailable upon request.HDPE Floating Covers for Saint-Gobain PerformancePlastics Cylindrical <strong>Tanks</strong>— Nominal Wall ThicknessFLOATING COVERCAT. NO. 54104Fits These Size <strong>Tanks</strong> Size Diameter Floating Cover(gallons) Code (inches) (thickness, inches)5-001110-3/81/167.5-0012121/1610-001312-3/41/1615-001413-1/81/1630-001818-1/83/3255-002221-1/23/32These covers do not fit Saint-Gobain tanks Cat. No. 56104.Installed Hinges for Saint-Gobain Performance PlasticsHigh-Performance <strong>Tanks</strong>— Nominal Wall ThicknessHinges available for all open-top vessels.Fits These Size <strong>Tanks</strong> Hinges for Covers Hinge Length(gallons) Cat. No. 87500 (inches)5 to 80100 to 200275 and 360500-0024-2536-3748-4960up to 2425 to 3637 to 4849 to 60Use the size to determine P/N for rectangular tanks. Some rectangular covers have ribs whichmay limit hinge placement. See page 7 for details.11


O P E N - T O P T A N K SOpen-Top Tank Fittings/AccessoriesInstalled and Loose FittingsBulkhead FittingsE.Welded Options Loose Accessories Bulkhead Fitting InstallationSee pages 14-16 for additional information.B.D.H.Tank Diameter MinimumsBulkhead SizeMin. Tank I.D.(inches)(inches)A.J.G.I.1/23/417.2510.0011.75D.C.F.1-1/41-1/216.2516.25A. FULL COUPLING, B. FLANGED COUPLING,C. HALF NIPPLE, D. HALF COUPLINGS,E. FLANGED COUPLING W/O SIDE SUPPORTSF. SIGHT GAUGE ASSEMBLY, G. CLOSE NIPPLE,H. FEMALE BALL VALVE, I. TUBING ADAPTER, J. SPIGOT23425.7542.5090.00For Open-Top <strong>Tanks</strong>INSTALLED FITTINGS, WELDED (<strong>Sanitary</strong> options see page 24)Welded fittings must be of the same resin as the tank on which they will be installed.Fittings cannot be welded to XLPE tanks.Size Code and Availability (X)K. BULKHEAD FITTING AND L.VITON® GASKETFitting Material B=Black Cat. No. -0025 -0050 -0075 -0100 -0125 -0150 -0200 -0300 -0400 -0600N=Natural (1/4") (1/2") (3/4") (1") (1-1/4") (1-1/2") (2") (3") (4") (6")K.L.A. Full Couplings,Female ThreadsPEPPBN8700589005——XXXXXX——XXXXX—X———B. FlangedCouplingsw/ HDPE Flange(Available with orwithout side supports)Spigot, Needle-Typew/ Boss and TwoTeflon TFE O-ringsC.Half Nipples,Male ThreadsPVDFPEPP Spigotw/ HDPE BossPEHDPE (FDA)NBNBN8700693400964239385793859—————XSpecify installation with one end flush inside of tank, or half in/half out. Coupling will be installed half in/half out unless otherwise specified.For room temperature service only. Specify nipples for service above 70°F/21°C and below 140°F/60°C.HDPE flanges are one-piece, all-plastic with 150 lbs. ASA bolt pattern dimensions.X—XXXX—For HDPE tanks up to 100 gallons. For larger tanks, use valves. PP spigots are installed on threaded HDPE boss, which is spin-welded onto tank at factory.Spigot has 1-1/8-12 straight female threads, 3/8 inch opening. Accepts 5/8 inch I.D. tubing. Boss fits only HDPE tanks.XXXXXXX—————XX—XXXX—XX—X—X——X—X——X———PPN95857—XXX—XXX——D. Half Couplings,Female ThreadsPVDFPEPPNBN938589384095840———XXXXXXXXX———XXXXXX—X——X————PVDFN93841—XXX—XX———12For room temperature service only. Specify nipples for above 70°F/21°C and below 140°F/60°C.


O P E N - T O P T A N K SOpen-Top Tank Fittings/AccessoriesFor Open-Top <strong>Tanks</strong>LOOSE FITTINGS, MECHANICALSize Code and Availability (X)Fitting Material Cat. No. -0025 -0050 -0075 -0100 -0125 -0150 -0200 -0300 -0400 -0600(1/4") (1/2") (3/4") (1") (1-1/4") (1-1/2") (2") (3") (4") (6")F.Sight-GaugeAssemblyPE/PVC96000-0001— X — — — —Consists of PVC valves, fittings and translucent PE tubing (5/8 inch I.D. x 3/4 inch O.D.). Specify tubing length.————G.Close NipplesPVC97103—XXXXXXXX—PP98103—XXXXXXXX—H.Ball Valves,ThreadedPVC97003—XPP98003 — X X X X X X —Female pipe thread on both ends. These valves must be supported.Installed with 93857 nipples, 97001 or 98001 bulkhead fittings and 97103 or 98103 close nipples. See page 23 for <strong>Sanitary</strong> Ball Valves.XXXXX—————I.Tubing Adapter(Insert-type),Male ThreadPVC97006 — X X X —For Saint-Gobain Performance Plastics TYGON® tubing. Complete with stainless steel hose clamp.XX———J.SpigotPP97424——X———————With male 3/4 inch thread and neoprene seat gasket. Can be easily field-installed with bulkhead fitting.Requires 3/4 inch female National Pipe Thread (NPT) fitting for installation.For Tubing:PVC—3/8" I.D. to 9/16" I.D. (1/16 inch wall)PVC—9/16" to 5/8" I.D. (1/8-3/16 inch wall)LDPE—5/8" I.D. (1/16 inch wall)Not for use on tanks greater than 100 gallonsSpigot, Needle-TypePP716421-0010X—Replacement spigot for Cat. No. 96423. Only fits on Saint-Gobain Performance Plastics-installed 1-1/8 x 12 inch straight threaded boss.Accepts 5/8 inch I.D. tubing.————————Quick-Action SpigotPP716422-0010X — — — — — — —Only fits on Saint-Gobain Performance Plastics-installed 1-1/8 x 12 inch straight threaded boss. Spigot accepts 5/8 inch I.D. tubing.Adapter accepts 1/4 or 5/16 inch I.D. tubing.——INSTALLED FITTINGS, MECHANICALK. Bulkhead FittingPVC, Installed87001XXXXXXXXX—PP, Installed88001XXXXXXXXX—PVC, Loose97001XXXXXXXXX—PP, Loose98001XXBulkhead fittings are supplied with one EPDM gasket. All two-part fittings screw together through a hole cut in the tank.Other gasket materials are available at added cost.XXXXXXX—Flanged Adapterw/o Bulkhead FittingPVC93420———X—XXXX—F.Sight-GaugeAssemblyPE/PVCINSTALLED76000-0001———X——————Consists of PVC valves, fittings and translucent PE tubing (5/8 inch I.D. x 3/4 inch O.D.).Installed close to top and bottom of tank unless otherwise specified.L. Gaskets for PPand PVC BulkheadFittingsEPDMVITON4808048090*Where an additional gasket is needed, or as a replacement for original gasket.†1-1/2 inch gasket can be used on 97001-0125 and 98001-0125 bulkhead fittings.——XXXXXX††XXXXXXXX——13


O P E N - T O P T A N K SGuidelines for InstallationFittings That Connect to Your SystemMany types of fittings are availablefor piping into your Saint-GobainPerformance Plastics cylindrical tanks,including bulkhead fittings, valves,nipples, spigots and tubing adapters.They are available factory-installed orWELDEDloose for field installation.Welded fittings are factory-installed, inthreaded or sanitary designs, and offersuperior sealing integrity. Fittings can onlybe welded to tanks of the same material.BULKHEADXLPE tanks cannot be welded. See page 12.Bulkhead-type fittings offer mechanicalseals with gaskets for factory or easyfield installation. See page 13.Guidelines for Factory-Installed FittingsBefore ordering a tank with factoryinstalledwelded fittings, consider spaceconstraints, tank elevation, whetherindoor or outdoor use, location, buildingcodes, safety regulations, piping and allother equipment that will be attachedto the tank.2.When tanks are elevated, weldedfittings can be installed low on thetank wall, providing drainage to within1/4-inch of the bottom (bulkheadsvary with size). The bulkhead mustnot interfere with the support.4.Welded fittings are not flush withtank bottom. This prevents completedrainage.1. When a fitting is welded onto theside of a tank that is not elevated,complete drainage is impossible. Thisapplies to flanges, spigots and bulkheads.Specify that the fitting’s centerlinemust be as close as possible tothe bottom of the tank. For maximumdrainage, see following descriptions.For complete drainage, a conical tankshould be used.3.Fittings welded to tank bottoms willdrain to within 1/8-inch of the bottom(bulkheads vary by size). The tank’sfoundation must have a cut-out orchannel of the fitting and its piping.14


O P E N - T O P T A N K SGuidelines for InstallationInstallation and Use of Saint-Gobain Performance Plastics High-Performance <strong>Tanks</strong>• Place the tank on a smooth, level surface, free of foreign objects. Maintaincomplete bottom support at all times, regardless of the type of tank. If outdoors,the site should be above any known flood plain and, if on soil, should beunsaturated, stable and compact.• <strong>Tanks</strong> mounted on vehicles should be both chocked and secured to the vehicleplatform. Do not put undue stress on tanks by over-tightening. Chocks must besecured by the platform on all four sides to prevent sliding.• Support the sides of all unsupported rectangular tanks over 18 inches inlength, width or depth. Casings are recommended.• Mount agitators, heaters and other heavy equipment on independent structuralmembers. The flanges of 13000-series Saint-Gobain tanks are designed to supportplating equipment, up to 300 lbs. per tank.• When piping is connected to a tank:Weight of strainer, heavy shut-off valves or heavy pipe must be supported,not carried by the tank connection. Use expansion joints to provide relief fromexpansion and contraction of piping and prevent damage of fittings.• All bulkhead fittings should be hand tightened and then given an additionalhalf-turn. Excessive tightening may distort gaskets, causing leaks.• Keep immersion heaters at least 1 inch from tank walls and bottom.• Protect tanks from impact, particularly at temperatures below 40°F/4°C.For low temperature service, specify cross-linked high-density polyethylene tanks.• Protect natural (white) tanks from direct sunlight. Black and/or UV-stabilizedtanks are recommended for outdoor use. See “Technical Information” on page 37of this catalog.• Do not subject tanks to maximum operating temperatures exceeding thoselisted in the “Tank Resin Selection Guide” on page 2.• Water test all plumbed-in tanks for a minimum of 5 hours before using.Plumbing leaks can then be identified and corrected.• Flush all tanks well with water before using.• Use tanks in accordance with the “Chemical Resistance Chart” on pages 39-44.WARNING: All Saint-Gobain Performance Plastics tanks are designed for atmospheric storageof chemicals. They should not be used for pressure, vacuum or direct burial applications.15


O P E N - T O P T A N K SGuidelines for InstallationFabrication Guide for Open-Top <strong>Tanks</strong>Fittings Sizes1. Is complete drainage required?Use conical-bottom tanks for complete drainage.2. What type of fitting is required? (Refer to pages 12-13)(a) sanitary (see page 24)(b) welded(c) mechanical (only type available for XLPE)Conical Tank Max. Bulkhead Max. BulkheadSize (gallons) on Cone Flat Fitting on Side1030551003/4"3/4"3/4"2"11.51.523. What size fittings is needed? (Refer to chart at right and also pages 12-13)1502"24. Accessories?2502"3These may need to be taken into consideration when determining type, size, orplacement of fittings.5. Fitting placement?4005003"3"33Use line drawings provided to show fitting placement. Reference as manydimensions as possible, such as distance from the bottom, side or top of tank;distance from other fittings. Please label fittings with part number or descriptionto avoid confusion.Flat-Bottom <strong>Tanks</strong>Size (gallons)5Max. BulkheadFitting on Side1"6. Is a stand needed?If a mixer is being used, a stand with support is required. Mixers, stands, and tankshave corresponding size codes (XXXXX-0250).7.510151"1"1"7. Is a casing required?Casings provide structural support which may be necessary to prevent deformationof the bottom of the tank. Maximum specific gravity WITH a casing is 2.2. Without,it is 1.8. A casing is recommended on rectangular tanks having a dimension over 18".Fittings may be installed through the casing. Casings have corresponding size codes(XXXXX-0250)3055801001-1/2"1-1/2"1-1/2"2"1502"2502"2753"3603"5003"10003"TANKS WITH CASING16


O P E N - T O P T A N K SPutting It All TogetherLidsHinged, slotted lids are available.All tanks ship with a coverLIGHTNIN MixerNever clamp a mixer to theside of the tankpage 11page 10FittingsCan be installed on cover,side and/or bottom of tankConical-BottomTankpages 12-13All tanks, pages 3-8Specify OutletSeveral valve optionsare availableElevated Conical-Bottom Tank Standpages 12-13 All tank stands, page 917


S A N I TAR Y V E S S E L S<strong>Sanitary</strong> <strong>Tanks</strong><strong>Sanitary</strong> Conical <strong>Tanks</strong>Developed to address the special needsof the pharmaceutical and relatedindustries, Saint-Gobain PerformancePlastics <strong>Sanitary</strong> Process Vessels aremanufactured from a special resinthat allows the unit to withstand autoclaving.These tanks provide corrosionprotection and also prevent metalliccontamination. A low-cost alternativeto metal, our sanitary tanks also offercomplete drainage and a wide assortmentof compatible accessories. Theunits are made to each customer’sunique process requirements. Samplingdevices, spray jets, mixers, threedrainage options, and specified fittingplacement are just a few examples ofthe options available. Typical applicationsinclude buffer mixing, mediapreparations, and small scale production.Modifications can also be made toaccommodate special size needs. Theunits are also completely compatiblewith Saint-Gobain Performance Plasticshoses, piping systems, and tubing products,helping to maintain Saint-GobainPerformance Plastics’ reputation as aworldwide leader in the pharmaceutical,industrial, and life science industries.For more information, call 800-543-8823.Or visit our web site atwww.plastics.saint-gobain.com.SANITARY PROCESSINGSANITARY TANK FAMILY18


S A N I TAR Y V E S S E L SClosed-Dome Bio <strong>Tanks</strong>Closed-Dome Bio <strong>Tanks</strong>—Polypropylene; Polypropylene ClosureExcellent for preparing media componentsand growing cultures. Closure andgasket material meet the specificationspromulgated under the Federal Food,Drug and Cosmetic Act, for use involvingcontact with food for human consumption.Please refer to the specificationslisted in Regulation 21 CFR177.1520(c) 3.1.Flat bottom on 75-liter size is ideal for usewith magnetic stir bars. Large, 6-inchgasketed closures make filling anddispensing easy. Molded-in body gripson 75-liter size provide safe, convenienthandling. Flat areas on 115- to 380-litersize for easy fitting installation.Molded-in graduations in liter and gallonincrements. Individually packaged.NOTE: An overhead mixer system is alsoavailable (Cat. Nos. 2653, 2654) and requiressanitary mixer support (Cat. No. 2651-0200).Installed sanitary fittings are also available.See autoclavable dolly (Cat. No. 2624).Autoclavable/Graduated/Leakproof.30- TO 100- GALLON SIZE WITHOVERHEAD MIXER SYSTEMCAT. NO.2650Cat. No. 2650 -0020 -0030 -0055 -0100Capacity, liter; gallons75; 20115; 30210; 55380; 100O.D. x Height, mm (nominal)419 x 813470 x 981559 x 1099724 x 1321O.D. x Height, in. (nominal)16-1/2 x 3218-1/2 x 38-5/822 x 43-1/828-1/2 x 51-1/4Wall Thickness, mm; in. (nominal)6.3; 1/46.3; 1/46.3; 1/47.9; 5/16Closed-Dome Bio Tank AccessoriesClosed-Dome Bio Tank Closurewith Mixer Support Assembly—Polypropylene, PVDF True Union ClampAn overhead mixer support assembly2651-0200 for use with all closed-domebio tanks (Cat. No. 2650) and high-densitypolyethylene closed-dome tanks (Cat. No.11150). The unique, sanitary flange assemblyallows for overhead mixing in a closedsystem. Designed specifically for usewith Saint-Gobain Performance PlasticsBioTech mixing unit (Cat. Nos. 2653, 2654),the assembly consists of a 6-inch PPscrew closure with a 2-inch sanitaryferrule welded in the center, a 2-inchsilicone gasket, and a true union fitting.Can be connected to other 2-inch sanitaryfittings for drain lines and closedsystem filling. Individually packaged.Autoclavable, but must be kept verticalif assembled with lower assembly(Cat. No. 2654). Autoclavable.Autoclavable Dolly—Stainless SteelDesigned to move small Saint-GobainPerformance Plastics tanks (up to 30gallons/115 liters) during daily use orservicing. Do not use for tanks withspigots. Non-corrosive and chemicallyresistant to acids and bases. Casterswon’t leave marks on floor. Autoclavable.Cat. No. 2624 -0030Maximum weight limits, lbs.;kgI.D. x H, in.; mm500; 227.320-1/2 x 6-1/2;521 x 16519


S A N I TAR Y V E S S E L S<strong>Sanitary</strong> Conical Process Vessels<strong>Sanitary</strong> Conical Process Vessels<strong>Sanitary</strong> Conical-BottomProcess SystemsSpecially designed for use in the biopharmaceuticalmarket, but suitable forany application where aseptic, sanitary,non-metallic fluid handling is desired.Each tank is manufactured from resinsthat meet USP Class VI and non-cytotoxicstandards and are suitable foruse in food and beverage applications.<strong>Tanks</strong> are available in autoclavablepolypropylene (PP) and chemical-resistantpolyvinylidene fluoride (PVDF).<strong>Sanitary</strong> ferrules installed to customerspecifications. Pre-engineered stands.<strong>Sanitary</strong> Conical-BottomProcess Vessels—PolyvinylideneFluoride (PVDF)• PVDF resin is extremely pure• Excellent chemical resistance• Non-cytotoxic standards• Fittings sold separately• Graduated• PVDF is not autoclavable• Call to discuss other methodsof sterilization<strong>Sanitary</strong> Conical-BottomProcess Vessels—Polypropylene• Our polypropylene resin is autoclavable• Excellent with dilute andstrong acids and bases• Non-cytotoxic standards• Autoclavable• USP Class VI• Silicone gasket and phenolicknobs included• Fittings and accessories soldseparately (see following pages)POLYPROPYLENECat. No. 2690 -0030 -0050 -0100 -0200 -0500 -0800 -1400Nominal Capacity, liter30501002005008001400Brim Capacity, liter33551102205508801540O.D. x Height, with Cover, cm44.5 x 49.355.6 x 49.855.6 x 83.666.3 x 105.791.4 x 131.3117.6 x 124.5152.4 x 123.4O.D. x Height, with Cover, in.17.5 x 19.622 x 19.622 x 3326 x 41.636 x 51.746.3 x 4960 x 48.6Weight, lb.25303580115157196POLYVINYLIDENE FLUORIDE (PVDF)Cat. No. 2691 -0030 -0050 -0100 -0200 -0500 -0800Nominal Capacity, liter3050100200500800Brim Capacity, liter3662115230550880O.D. x Height, with Cover, cm44.5 x 49.355.6 x 49.855.6 x 83.666.3 x 105.791.4 x 131.3117.6 x 124.5O.D. x Height, with Cover, in.17-1/2 x 1822 x 2122 x 25-1/226 x 4136 x 51.746.3 x 49Weight, lb.404550105135182These part numbers represent a tank with a solid, bolted, gasketed cover.20


S A N I TAR Y V E S S E L SConical Tank StandsTank StandsPortable Tank Stands• Optimal mobility• Rounded surfaces for easy cleaning• Passivated• Locking casters• Convenient handgrip• Casters may be removedIndustrial-StyleStand Option (not shown)• Lower-cost alternative to theportable cart• Flat, angled steel construction• Same size and configuration asshown on page 9• Options:• 304 or 316 stainless steel• <strong>Sanitary</strong> casters• Support ring• Handles• Mixer supportPORTABLE TANK STAND—304 Stainless SteelCat. No. 2710 -0030 -0050 -0100 -0200 -0500 -0800 -1400Fits Tank Size30 Liters 50 Liters 100 Liters 200 Liters 500 Liters 800 Liters 1400 LitersPORTABLE TANK STAND—Powder-Coated Stainless Steel (White)Cat. No. 2711 -0030 -0050 -0100 -0200PORTABLE TANK STAND,CAT. NO. 2710 W/2690Fits Tank Size30 Liters 50 Liters 100 Liters 200 Liters21


S A N I TAR Y V E S S E L S<strong>Sanitary</strong> Tank MixersBioTech Mixing SystemsMIXER OVERHEAD DRIVECAT. NO.2653Pre-engineered, ready-to-use mixerpackages, Saint-Gobain PerformancePlastics BioTech mixer overhead drivesand lower assemblies/shafts and impellershave been specially designed to delivermaximum mixing efficiency. Each componenthas been carefully chosen tomatch a specific Saint-Gobain PerformancePlastics mixing vessel. Use them withthe closed-dome bio tanks (Cat. No. 2650)and sanitary conical-bottom processingtanks (Cat. Nos. 2690/2691). Requires2" sanitary connection (2661-0200) at10°< (for conical units), 2" silicone gasket(2672-0200) and true union (2670-0200).Saint-Gobain Performance Plastics vesseland mixer packages are designed for liquidsand liquid slurries only. Saint-Gobaindoes not warrant them for any specificapplication, only general-purpose mixingup to these maximum limits:• Solids—20% by weight• Specific Gravity (batch)—1.2• Viscosity—500 centipoiseBioTech Mixer Overhead DrivesOverhead drives are available in twopower configurations—1/20 HorsePower and 1/8 Horse Power.Both Drives Feature:• Autoclavable in-place• Variable speed controls for betteraccuracyCat. No. 2653 -0001 -0002Electrical requirementsPower (W)RPMHPLOWER ASSEMBLY/SHAFTCAT. NO.2654115V/60 Hz/1 PH4020-2501/20115V/60 Hz/1 PH11520-1401/8Lower module allows for use with 110/220 v, 50/60 Hz and accepts a universallyavailable power cord.NOTE: Lower assemblies/shafts and impellers and mixer support (required for closed-dome tanksonly) are necessary to complete each system and are sold separately (see Cat. Nos. 2654 and 2651).• Programmable timers for hands-offcontrol• LCD readouts for speed, power, torque,impeller flow and time• Audible overload alarm1/20 H.P. (Cat. No. 2653-0001)• 75-liter closed-dome tanks• 30- and 50-liter sanitary conicalbottomprocessing tanks1/8 H.P. (Cat. No. 2653-0002)• 30-, 50-, and 100 gallonclosed-dome tanks• 100-liter sanitary conical-bottomprocessing tanks• 200-liter sanitary conical-bottomprocessing tanks• Can be used interchangeablywith all sanitary units under 200L.Lower Assemblies/Shaftsand Impellers• For use with overhead drive• 316 stainless steel shaft• 316 stainless steel axial-flow impellers• Autoclavable• Encapsulated assemblies available—non-metallic wetted surfaces• Attaches to 2" connection withtrue union and gasketLOWER ASSEMBLIES/SHAFTS AND IMPELLERSCat. No. For Use With Overhead* Drive Shaft Length Shaft Diameter Impeller Diameter ImpellerCat. No. (in., mm) (in., mm) (in., mm) Material2654-0030†30-gallon closed-dome bio tank (2650-0030)2653-000230; 7621/2; 136.8; 173Stainless Steel2654-003130- and 50-L sanitary conical tanks(2690/2691-0030, -0050)2653-000117; 4321/2; 136.1; 155Stainless Steel2654-0055†55-gallon closed-dome bio tank (2650-0055)2653-000232; 8131/2; 138.8; 224Stainless Steel2654-0075†75-L closed-dome tank (2650-0020)2653-000123; 5841/2; 136.3; 160Stainless Steel2654-0101100-L sanitary conical tank (2690/2691-0100)2653-000228; 7111/2; 136.1; 155Stainless Steel2654-0100†100-gallon closed-dome bio tank (2650-0100)2653-000238; 9651/2; 1310; 254Stainless Steel2654-0201200-L sanitary conical tank (2690/2691-0200)2653-000236; 9141/2; 138.8; 225Stainless Steel22* The 2653-0002 is appropriate for use with all tanks. †Requires mixer support (2651-0200).


S A N I TAR Y V E S S E L S<strong>Sanitary</strong> Drain OptionsDrain Option ProductsPOLYPROPYLENE VALVE BODYWITH SILICONE, CAT. NO. 2695DIAPHRAGM VALVE,CAT. NO. 2674POLYPROPYLENE BALL VALVE,CAT. NO. 2673<strong>Sanitary</strong> Conical Drain Valve—Polypropylene Valve BodyWith Silicone Diaphragm• Manually activated• Allows for complete drainage• Assures complete mixing• Eliminates “dead leg”• Stainless steel spacer ring• Stainless steel actuator• Glass-filled acetal locking ring• Factory installed onlyDiaphragm Valve— Polypropylene• USDA, food-grade polypropylenehousing• Perfluoroalkoxy (PFA) interiordiaphragm• Multi-position handle to precisely varythe flow rate• Flush time approximate 6 seconds• Not autoclavableCONICAL DRAIN VALVE—PolypropyleneBall Valve— Polypropylene• USDA, food-grade polypropylene ball• 1/4-turn opening and closing• <strong>Sanitary</strong> flanges• Flush time approximate 45 seconds• Autoclavable when handle is removedCat. No. 2695 -1501 -2001 -2101Size, mm; in.38; 1-1/2 51; 2 51; 2** Fits 1400-L sanitary conical-bottom tanks only.CONICAL DRAIN VALVE—PVDFCat. No. 2697 -1501 -2001Size, mm; in.38; 1-1/2 51; 2REPLACEMENT DIAPHRAGMSCat. No. 2696 -1501 -2001Size, mm; in.Diaphragm Material38; 1-1/2Silicone51; 2SiliconeDIAPHRAGM VALVE—PolypropyleneCat. No. 2674 -0150**Size, mm; in.38; 1-1/2BALL VALVE—PolypropyleneCat. No. 2673 -0150**Size, mm; in.38; 1-1/2 tri** Other sizes available23


S A N I TAR Y V E S S E L S<strong>Sanitary</strong> Fittings and Accessories<strong>Sanitary</strong> Fittings/AccessoriesThe following accessories and factory-installed ferrules are availableoptions for Saint-Gobain Performance Plastics sanitary tank products.Use them to modify the tank for your specific application. Specify fittingsand placement location when ordering tank.SANITARY FERRULES,CAT. NO.2660Installed <strong>Sanitary</strong>Ferrules—High-DensityPolyethylene;Polypropylene;Polyvinylidene Fluoride• Customize the vesselsto your specificprocessing needsusing the ferrules• Accessories require2" connections forinstallationINSTALLED SANITARY FERRULES—HDPECat. No. 2660 -0075 -0100 -0150 -0200 -0300 -0400 -0600Size, mm; in.19; 3/4 mini 25; 1 tri/ladish 38; 1-1/2 tri 51; 2 tri 76; 3 tri 102; 4 tri 152; 6 triINSTALLED SANITARY FERRULES—PPCat. No. 2661 -0075 -0100 -0150 -0200 -0300 -0400 -0600Size, mm; in.19; 3/4 mini 25; 1 tri/ladish 38; 1-1/2 tri 51; 2 tri 76; 3 tri 102; 4 tri 152; 6 triINSTALLED SANITARY FERRULES—PVDFCat. No. 2692 -0075 -0100 -0150 -0200 -0300 -0400Size, mm; in.19; 3/4 mini 25; 1 tri/ladish 38; 1-1/2 tri 51; 2 tri 76; 3 tri 102; 4 tri4" and larger fittings may have placement restrictions. Contact customer service ortechnical department for assistance.<strong>Sanitary</strong> GasketsPlatinum-Cured Silicone• AutoclavableSANITARY GASKETS—Platinum-Cured SiliconeCat. No. 2672 -0075 -0100 -0150 -0200 -0300 -0400 -0600Size, mm; in. 193/4 mini251 tri/ladish381-1/2 tri512 tri763 tri1014 tri1526 triSANITARY GASKET,PLATINUM-CURED, CAT. NO. 2672Viton®* Fluoroelastomer• Not autoclavableSANITARY GASKETS—Viton ® FluoroelastomerCat. No. 2671 -0075 -0100 -0150 -0200 -0300Size, mm; in. 19; 3/4 mini 25; 1 tri/ladish 38; 1-1/2 tri 51; 2 tri 76; 3 triSANITARY GASKET, VITON ® ,CAT. NO. 2671TRUE UNION CLAMPS,CAT. NO. 2670True UnionClamps— PVDF• For prevention ofdamage to plasticconnection• AutoclavableTRUE UNION CLAMPS—PVDFCat. No. 2670 -0075 -0150 -0200 -0300Size, mmSize, in.193/4 mini381-1/2 triRecommended for use with plastic fittings.Avoids over-tightening which can crack the fitting.Maintains concentric connections.512 tri763 tri24


S A N I TAR Y V E S S E L S<strong>Sanitary</strong> Fittings and Accessories<strong>Sanitary</strong> Fittings/AccessoriesEND CAPS—PolypropyleneCat. No. 2665 -0075 -0150 -0200 -0300 -0400 -0600Size, mmSize, in.193/4 mini381-1/2 tri512 tri763 tri1024 tri1526 triEnd Caps—Polypropylene• Autoclavable, sealsferrule when not in useSIGHT CAPS—Polysulfone*Cat. No. 2666 -0200- 0300Size, mm; in.51; 2 tri 76; 3 triSight Caps—Polysulfone• Autoclavable• Allows visibilityinto vesselEND AND SIGHT CAPS,CAT. NOS. 2665 AND 2666ELBOW SWEEPS—Polypropylene*Cat. No. 2662-0150 2663-0150AngleSize, mm, in.90°38, 1-1/2 tri45°38, 1-1/2 triElbow Sweepsand ConcentricReducers—Polypropylene• AutoclavableCONCENTRIC REDUCERS—Polypropylene*Cat. No. 2669 -0001 -0002 -0004 -0005 -0006Size, mmSize, in.19 x 383/4 mini x 1-1/2 tri25 x 381 tri x 1-1/2 tri51 x 382 tri x 1-1/2 tri51 x 252 tri x 1 tri51 x 762 tri x 3 triELBOW SWEEPS,CAT. NO.2663HEAVY DUTY CLAMP—Stainless SteelCat. No. 2685 -0150 -0200 -0300 -0400 -0600Size, mm; in. 38; 1-1/2 1; 2 76; 3 102; 4 152; 6Not recommended for use with plastic fittingsHeavy Duty Clamps—Stainless Steel• Spring-loaded clamps toassure tight, leakprooffluid connections• AutoclavableHEAVY DUTY CLAMP,CAT. NO.2685*Other sizes available.25


S A N I TAR Y V E S S E L S<strong>Sanitary</strong> Fittings and Accessories<strong>Sanitary</strong> Fittings/AccessoriesSIPHON TUBESiphon TubesFor use on Saint-GobainPerformance Plasticsclosed-dome bio tanks(Cat. No. 2650) for easyfluid transfer using a peristalticor vacuum pump.This 3/4-inch mini-siphontube (5/8-inch I.D.) has a2-inch sanitary mount andconnects to mount on a2-inch (50-mm) sanitaryfitting. Tubes are cut toappropriate lengths for the 20-, 30-, 55-and 100-gallon (75-, 115-, 210- and 380-liter)tanks. Fittings must be installed on tankto use this product. Materials are noncytotoxic,meet USP Class VI and complywith 21 CFR 177.1520 for food and beverageuse.* Autoclavable.<strong>Sanitary</strong> Process VesselSiphon Tubes—PolypropyleneFor product sampling, reagent introductionand drainage. Removable siphon tubemounts to a 2-inch sanitary flange andextends into the bottom of cone. Rigid3/4-inch (19-mm) mini-tube is compatiblewith common sanitary connectors includingsanitary adapters, Sani-Lock, trueunionclamps, short bull tees and gaskets.Siphon tube does not interfere with lowerassembly during mixing. Complies with21 CFR 177.1520(c) 3.1 and USP Class VIregulations. Non-cytotoxic. Tubes are cutto length. Autoclavable.SIPHON TUBECat. No. 2656 -0030 -0050 -0100 -0200Capacity, liter; gallons75; 20115; 30208; 55378; 100 <strong>Sanitary</strong>Mount, mm; in.51; 251; 251; 251; 2Tube I.D., mm; in.16; 5/816; 5/816; 5/816; 5/8Tube O.D., mm; in.25; 0.98525; 0.98525; 0.98525; 0.985Tube Length, cm; in.92; 36-1/3103; 40-1/2115; 43-1/3135; 53SANITARY PROCESS VESSEL SIPHON TUBECat. No. 2658 -0050 -0200Capacity, liter; gallonsMount, mm; in.Tube I.D., mm; in.Tube O.D., mm; in.Tube Length, cm; in.For use with sanitary connection50; 1351; 214; 9/1619; 3/490; 35-1/43/4-in. mini200; 5351; 214; 9/1619; 3/497; 383/4-in. mini*Polypropylene meets all food grade requirements except for use with Food Type IV A (water-in-oil emulsions)and Food Type V (low-moisture fats and oils). The food type definitions are listed in 21 CFR 176.170(c).26


S A N I TAR Y V E S S E L S<strong>Sanitary</strong> Fittings and Accessories<strong>Sanitary</strong> Fittings/AccessoriesROTARY SPRAY JET,CAT. NO. 2677-0001APPARATUS FOR SPRAY JETNOZZLE, CAT. NO. 2678-0001SANI-SAMPLING DEVICE,CAT. NO. 2680-0001Rotary Spray Jet—Acetal With Stainless Steel Spray InsertsFor cleaning Closed-Dome Bio Tank and<strong>Sanitary</strong> Process Vessel interiors. Mountsand fits through a 2-inch sanitary flange;easily removable. Provides minimum of300° spray pattern for complete cleaning.Must order Mounting Assembly (Cat. No.2678-0001) separately. Autoclavable.ROTARY SPRAY JET—Acetal with Stainless Steel Spray InsertsCat. No. 2677 -001PressureFlow Rate20 to 30 psig.6 to 7 gal./min.Mounting Apparatus forSpray Jet Nozzle—PolysulfoneMounting apparatus 2678-0001 permitsuse of Rotary Spray Jet (Cat. No. 2677-0001). Mounts to a 2-inch sanitary flange.Easily removable. Ends in a 3/4-inch miniflange. Cleans with tank/vessel lowerassembly in place. Autoclavable.1-INCH LADISH CHARGINGELBOW, CAT. NO. 2681-00011-Inch Ladish Charging Elbow—Polypropylene With 2-inch<strong>Sanitary</strong> MountWhen adding fluid, 2681-0001 elbowdeflects flow to side of container wall,minimizing foaming. Prevents alteringof buffer pH solutions and proteindegradation. Autoclavable.Sani-Sampling Device—Polypropylene With 2-inch<strong>Sanitary</strong> MountCatalog No. 2680-0001.Polypropylenesample tube extends into upper 1/4 ofClosed-Dome Bio <strong>Tanks</strong> or <strong>Sanitary</strong>Process Vessels. Uses PTFE Syringe Filterand 3-way Luer-Lok ® * valve. Luer-Lok ®connections allow easy connection tosyringes and other micro tubing.Autoclavable.Sani-Sampling Valve—3-Way,PolypropyleneCatalog No. 2683-0001. Three-wayLuer-Lok® valve. Allows easy connectionto PTFE syringe filters or Sani-SamplingDevice (Cat. No. 2680-0001).Autoclavable.27


S A N I TAR Y V E S S E L SProper Placement and Autoclave InstructionsFabrication Guide for <strong>Sanitary</strong> Conicals (2690-Series)1. How is tank being drained?(a) <strong>Sanitary</strong> drain valve (2695-XXXX)(b) Diaphragm valve (2674-0150)(c) Ball valve (2673-0150)If (a), what size?If (b) or (c), it needs a 1.5" sanitary ferrule in the cone (2661-0150).Other sizes are available custom.2. Is a spray jet or other cleaning system being used?If yes, and it’s our system, a spray jet (2677-0001), mounting apparatus (2678-0001),2" ferrule (2661-0200), 2" silicone gasket (2672-0200), and 2" true union (2670-0200)are needed. For 200L and smaller units, 1 spray jet with 2" center mount is sufficient.500 and 800L require (2) and 1400L requires (3) equally spaced jets.3. Is a mixer being used?If 200L or smaller, use the mixer recommended in the catalog. Our mixer requires a2" ferrule (2661-0200), 2" silicone gasket (2672-0200), and 2" true union (2670-0200).The ferrule is installed at a 10° angle and has standard placement. For mixers 500Lor larger, you may contact us or a LIGHTNIN representative.4. Are any accessories being used?If yes, all our accessories require a2" ferrule (2661-0200), 2" siliconegasket (2672-0200), and 2" true union(2670-0200), plus the part number ofthe accessory. Specify placementwhen ordering.5. Are other ports required?Use appropriate size ferrule.Specify placement. A vent is needed ifinlets/outlets are specified.6. Are end caps required?These are not installed on the tank attime of shipment unless requested.End caps need a gasket and true unionof the same size.7. What type of stand is needed?Portable carts are available for all sizesof <strong>Sanitary</strong> Process Vessels. Mixers forthe larger vessels are too heavy to besupported by the tank alone. Our “industrial”stands are available in S/S as analternative to the carts and are availablewith mixer support.Information on Autoclaving Polypropylene ProductsAutoclaving represents one of the most severe application conditions to whichSaint-Gobain Performance Plastics High-Performance <strong>Tanks</strong> may be subjected. Duringthe autoclaving cycle, products are typically maintained at 15 psig, while at temperaturevery near the plastics’ heat deflection temperature. Under these conditions, any force,weight or pressure bearing on the product can contribute to deformation or collapse.Plastic vessels and containers cannot be sealed when autoclaving. For best results,products should be free standing and loosely covered, or with their closures resting ontop with threads disengaged. During the decompression phase of the autoclaving cycle,the pressure within the vessel must be allowed to equalize. Any material placed overthe opening may cause a vacuum to form, resulting in implosion or collapse.The recommended autoclaving cycle is 121°C, 15 psig for 20 minutes.The following practices should be AVOIDED when autoclaving plastic products:• Stacking of jars, vessels, and carboys• Placing the product in an autoclaving basket with other objects on top• Tightening of closure prior to cooling• Securing any of the following over the opening:• Aluminum foil• Blue Steriwrap• Gauze• Cotton• TapeNOTE: Customers often report improved performance by autoclaving new products completelyuncovered the first time. This practice may condition the product, relieving any residual stressesfrom the molding process and rendering it more resistant to subsequent autoclaving.28


S A N I TAR Y V E S S E L SPutting It All Together<strong>Sanitary</strong>Process Vesselpages 19-21<strong>Sanitary</strong>Mixerspage 22FittingsPortableConical-BottomTank Stand<strong>Sanitary</strong> stands,page 21pages 24-27Drain ValveAccessoriespage 23pages 24-2729


B L O W E R SBlowers for Lab and Industrial UseReliable, All-Plastic Corrosion-Resistant UnitsLAB-STYLE BLOWERDIRECT DRIVE UNITSaint-Gobain Performance Plastics’Norton ® Blowers are excellent choicesfor aggressive applications where metalblowers quickly corrode. Metal blowersrely on protective coatings, which developpin holes and pores. Corrosive vaporsseep through and attack the metal,causing failure. Plastic blowers lastmuch longer because the material isinherently resistant to corrosion.The smaller laboratory units have roundinlets and outlets. They are designed foruse in lab hoods and cabinets. They areavailable in direct drive with 2 motoroptions and 2 wheel options.The industrial units have round inletsand square outlets and offer muchgreater capacity.They are proven performers in toughindustrial applications, such as metalfinishing, chemical manufacturing,wastewater treatment, and chemicalstorage cabinets. In addition to theoptions for drives, motors, and wheels,a full line of transitions and flexibleconnectors is available for connectionto ductwork.Norton blowers are ordered by selectingthe right capacity, type of drive, motorand combination of plastic materialsfor your application. The “Four Steps toBlower Selection” on the followingpages will guide you.Blower Features• Corrosion resistant• Outlasts metal• Quiet operation• Choice of motors/materials• Reinforced housing• For indoor and outdoor † use• Plastic transitions for easy attachmentto standard ducting• Full line of replacement partsIf installing your own motor, note thatNorton blowers must not exceed thestated RPM of each blower (pages 32-34).Industrial blowers feature round inletsand rectangular outlets. (For plastictransitions, see page 36)NOTE: Blowers are supplied fully assembledin counterclockwise upblast position. Othercounterclockwise positions are available onrequest.*†Protect motors and drives against weatherwhen blowers are roof-mounted.All outdoor vertical blower discharge ductsmust have weather hoods.*Except Cat. No. 71300 Series Lab Blower—no bottom horizontal or down-blast positions.BELT DRIVE UNIT30


B L O W E R SBlower SelectionFour Steps to Blower Selection1. Determine CFM and Static PressureCFM is Cubic Feet per Minute and represents the volume of the area to be ventilated.Static Pressure is measured in inches of water. It is the total resistance to incomingair flow from ducts, fittings, elbows, dampers, and other factors.You can determine your existing unit’s capacity by checking the size and performancespecs. For new installations, the CFM and Static Pressure should be determined by amechanical engineer, HVAC contractor, ductwork manufacturer or other professional.All our blowers are 60Hz.For performance curves, please contact Customer Support.2. Select Direct or Belt Drive (if needed)Some size blowers are only available in direct drive. Others can be belt driven as anoption. Consult page 35 for availability.Direct DriveMore compactSingle speedFewer moving partsNo field adjustmentBelt DriveField adjustable to vary capacityFlexible to process changesReduces stress on motor bearingsEconomical in changing environments3. Motor SelectionMotor Type Features ApplicationsTotally Enclosed Fan-Cooled (TEFC)Explosion Proof (XP)Housings have no direct openingsInternal fan cools motorInsulatedUL-approved motor*InsulatedCorrosive vaporsDirty, damp or oily serviceForward curve blades* UL and CSA for Class I, Group D or Class II, Group F and G.4. Material Selection of WheelThe wheel’s chemical resistance takes priority because it is under centrifugal stress.PVCGood chemical resistanceBest at room temperatureLow costPolypropyleneVery good general chemical resistanceWithstands higher temperatures, stressesPotentially explosive fumes or dustGENERAL NOTES: Lab Blowers (sizes codes -0050 to -0150) have round inlets and outlets.Industrial blowers have round inlets and rectangular outlets (see dimension charts).All blowers used outdoors must be protected against weather.Blowers are supplied in counter-clockwise up-blast position. Other positions may be requested.31


B L O W E R SBlower SpecificationsLab Blower Specifications These charts are arranged by increasing CFM. All lab blowers are 60Hz.See the preceding “Four Steps To Blower Selection.”140 to 225 CFM — 3/4 to 1/4 inch Static PressureSIZE CODES -0050/0075Drive Motor Material Replacement* RPM HP Power Voltage Approx. Shipping Cat. No.Enclosure Wheel/Housing Parts (Phase) (wt., lbs.) and Size CodesDir.XPPP/PVC117251/6115 (1)51†71320-0075Dir.TEFCPP/PVC117251/6115/208-230 (1)31†71330-0050360 to 625 CFM — 3/4 to 1/4 inch Static PressureSIZE CODES -0050/0075Drive Motor Material Replacement* RPM HP Power Voltage Approx. Shipping Cat. No.Enclosure Wheel/Housing Parts (Phase) (wt., lbs.) and Size CodesDir.XPPP/FRP211401/3115/230 (1)60†71420-0075Dir.TEFCPP/FRP211401/3115/208-230 (1)60†71430-0050Dir.XPPVC/FRP411401/3115/230 (1)60†71520-0075Dir.TEFCPVC/FRP311401/3115/208-230 (1)60†71530-0050710 to 1,025 CFM — 1-1/4 to 1/4 inch Static PressureSIZE CODES -0100/0150Drive Motor Material Replacement* RPM HP Power Voltage Approx. Shipping Cat. No.Enclosure Wheel/Housing Parts (Phase) (wt., lbs.) and Size CodesDir.XPPP/FRP217251/3115/230 (1)60†71420-0150Dir.TEFCPP/FRP217251/3115/208-230 (1)60†71430-0100Dir.XPPVC/FRP317251/3115/230 (1)60†71520-0150Dir.TEFCPVC/FRP317251/3115/208-230 (1)60†71530-0100Industrial Blower Specifications These charts are arranged by increasing CFM. All lab blowers are 60Hz.All industrial blowers have round inlets and rectangular outlets. See dimension charts later in this section for details.Plastic transitions are available to connect blowers to ductwork; refer to the last page in this section.355 to 500 CFM — 1-1/4 to 3/4 inch Static PressureSIZE CODES -0160Drive Motor Material Replacement* RPM HP Power Voltage Approx. Shipping Cat. No.Enclosure Wheel/Housing Parts (Phase) (wt., lbs.) and Size CodesDir.XPPP/PVC517251/3208-230/460 (3)5872521-0160Dir.TEFCPP/PVC517251/3208-230/460 (3)6072531-0160Dir.XPPVC/PVC617251/3208-230/460 (3)5872621-0160Dir.TEFCPVC/PVC617251/3208-230/460 (3)6072631-0160BeltXPPP/PVC517251/3208-230/460 (3)13572721-0160BeltTEFCPP/PVC517251/3208-230/460 (3)13072731-0160BeltXPPVC/PVC617251/3208-230/460 (3)13772821-0160BeltTEFCPVC/PVC617251/3208-230/460 (3)13272831-016032


B L O W E R SBlower SpecificationsIndustrial Blower Specifications These charts are arranged by increasing CFM. All blowers are 60Hz.650 to 800 CFM — 1 to 3/4 inch Static PressureSIZE CODES -0200Drive Motor Material Replacement* RPM HP Power Voltage Approx. Shipping Cat. No.Enclosure Wheel/Housing Parts (Phase) (wt., lbs.) and Size CodesDir.XPPP/PVC711403/4208-230/460 (3)12572520-0200Dir.TEFCPP/PVC711403/4208-230/460 (3)11372530-0200Dir.XPPVC/PVC811403/4208-230/460 (3)12872620-0200Dir.TEFCPVC/PVC811403/4208-230/460 (3)11672630-0200730 to 1,100 CFM — 2 to 1-1/4 inch Static PressureSIZE CODES -0200Drive Motor Material Replacement* RPM HP Power Voltage Approx. Shipping Cat. No.Enclosure Wheel/Housing Parts (Phase) (wt., lbs.) and Size CodesDir.XPPP/PVC717253/4208-230/460 (3)12872521-0200Dir.TEFCPP/PVC717253/4208-230/460 (3)12272531-0200Dir.XPPVC/PVC817253/4208-230/460 (3)11672621-0200Dir.TEFCPVC/PVC817253/4208-230/460 (3)11672631-0200BeltXPPP/PVC717253/4208-230/460 (3)13872721-0200BeltTEFCPP/PVC717253/4208-230/460 (3)13872731-0200BeltXPPVC/PVC817253/4208-230/460 (3)14072821-0200BeltTEFCPVC/PVC817253/4208-230/460 (3)15072831-0200960 to 1,210 CFM — 1-1/4 to 1 inch Static PressureSIZE CODES -0250Drive Motor Material Replacement* RPM HP Power Voltage Approx. Shipping Cat. No.Enclosure Wheel/Housing Parts (Phase) (wt., lbs.) and Size CodesDir.XPPP/PVC911401230-460 (3)13572520-0250Dir.TEFCPP/PVC911401208-230/460 (3)12272530-0250Dir.XPPVC/PVC1011401230-460 (3)13872620-0250Dir.TEFCPVC/PVC1011401208-230/460 (3)12572630-02501,110 to 1,910 CFM — 3 to 2 inch Static PressureSIZE CODES -0250Drive Motor Material Replacement* RPM HP Power Voltage Approx. Shipping Cat. No.Enclosure Wheel/Housing Parts (Phase) (wt., lbs.) and Size CodesDir.XPPP/PVC917251-1/2208-230/460 (3)14072521-0250Dir.TEFCPP/PVC917251-1/2208-230/460 (3)12472531-0250Dir.XPPVC/PVC1017251-1/2208-230/460 (3)14072621-0250Dir.TEFCPVC/PVC1017251-1/2208-230/460 (3)13072631-0250BeltXPPP/PVC917251-1/2208-230/460 (3)16072721-0250BeltTEFCPP/PVC917251-1/2208-230/460 (3)15572731-0250BeltXPPVC/PVC1017251-1/2208-230/460 (3)22072821-0250BeltTEFCPVC/PVC1017251-1/2208-230/460 (3)19072831-025033


B L O W E R SBlower SpecificationsIndustrial Blower Specifications These charts are arranged by increasing CFM. All lblowers are 60Hz.1,410 to 2,210 CFM — 1-1/4 to 1 inch Static PressureSIZE CODES -0310Drive Motor Material Replacement* RPM HP Power Voltage Approx. Shipping Cat. No.Enclosure Wheel/Housing Parts (Phase) (wt., lbs.) and Size CodesDir.XPPP/PVC1111402230/460 (3)26072520-0310Dir.TEFCPP/PVC1111402208-230/460 (3)16272530-0310Dir.XPPVC/PVC1211402230/460 (3)19572620-0310Dir.TEFCPVC/PVC1211402208-230/460 (3)20672630-03102,900 to 3,640 CFM — 3-1/4 to 2-3/4 inch Static PressureSIZE CODES -0310Drive Motor Material Replacement* RPM HP Power Voltage Approx. Shipping Cat. No.Enclosure Wheel/Housing Parts (Phase) (wt., lbs.) and Size CodesDir.XPPP/PVC111725530/460 (3)22072521-0310Dir.TEFCPP/PVC1117255208-230/460 (3)15272531-0310Dir.XPPVC/PVC1217255230/460 (3)22572621-0310Dir.TEFCPVC/PVC1217255208-230/460 (3)17272631-0310BeltXPPP/PVC1117255230/460 (3)27772721-0310BeltTEFCPP/PVC1117255208-230/460 (3)23772731-0310BeltXPPVC/PVC1217255230/460 (3)28372821-0310BeltTEFCPVC/PVC1217255208-230/460 (3)28472831-03103,350 to 5,000 CFM — 3 to 2 inch Static PressureSIZE CODES -0400Drive Motor Material Replacement* RPM HP Power Voltage Approx. Shipping Cat. No.Enclosure Wheel/Housing Parts (Phase) (wt., lbs.) and Size CodesDir.XPPP/PVC1311405230-460 (3)27072520-0400Dir.TEFCPP/PVC1311405208-230/460 (3)28572530-0400Dir.XPPVC/PVC1411405230-460 (3)30072620-0400Dir.TEFCPVC/PVC1411405208-230/460 (3)29572630-0400BeltTEFCPP/PVC1311405208-230/460 (3)37072730-0400BeltTEFCPVC/PVC1411405208-230/460 (3)38072830-040034COMMON REPLACEMENT PARTSReplacement No. PVC Wheel PP Wheel Shaft Extension Housing Back Plate Gasket123456789†1011121314——71509-000371509-0004—72609-0160—72609-0200—72609-0250**72629-0250†—72609-0310—72609-0400Match the replacement part numberwith the required item below.71309-000271409-0002——72509-0160—72509-0200—72509-0250**72529-0250†—72509-0310—72509-0400—*The shaft extension of the 71420-0150 blower was redesigned in 1986. For blowersup to and including serial number 71E463109,order shaft extension 71409-0034.For blowers with higher serial numbers, order shaft extension 71409-0035.71309-003571409-0035/71409-0034*IncludedIncludedIncludedIncludedIncludedIncludedIncludedIncludedIncludedIncludedIncludedIncludedCall Saint-Gobain Performance Plastics forpricing on any housing, back plate or gasket.71309-000471409-003171409-003171409-003172509-001172509-001172509-001272509-001272509-001372509-001372509-001472509-001472509-001572509-0015†For blowers up to and includingserial number 72E56243—will accepta motor with 0.625 diameter shaft.————72509-001672509-001672509-001772509-001772509-001872509-001872509-001972509-001972509-002072509-0020————72509-003872509-003872509-003972509-003972509-004072509-004072509-004172509-004172509-004272509-0042**For serial numbers above72E56243—will accept a motorwith 0.875 diameter shaft.


B L O W E R SBlower SpecificationsLAB BLOWER—Dimensions (Inches)Cat. No. A B C D E F G H J K71330-005071320-007571430-, 71530-005071420-, 71520-007571430-, 71530-010071420-, 71520-01505-5/85-5/89-1/29-1/29-1/29-1/26-5/86-5/87-1/47-1/47-1/47-1/43-3/43-3/44-1/24-1/24-1/24-1/25-5/85-5/888889910-1/210-1/210-1/210-1/2777-1/47-1/47-1/47-1/414-1/2—19—18-1/2——15-1/2—19-1/2—21-1/2111115-1/815-1/815-1/815-1/84-1/24-1/28888INDUSTRIAL BLOWERS WITH DIRECT DRIVE—Dimensions (Inches)Cat. No. Size CodeINLET DIAMETER, IN.I.D. O.D. A B E G H H1 K72520, 72521 -0160 6-1/4 6-5/8 6 4-9/16 1/2 13-1/4 10 15-11/16 1072530, 72531 -0200 7-3/8 7-3/4 7-7/16 5-1/8 1/2 14-1/2 14 21-11/16 1072620, 72621 -0250 9-3/8 9-3/4 9-3/8 6-11/16 1/2 15-3/4 15-15/16 24-3/16 11-1/272630, 72631 -0310 12-3/8 12-3/4 11-7/8 9-11/16 1/2 17-1/4 20-15/16 31-9/16 13-1/2-0400 15-5/8 16 15-5/8 11-7/8 3/4 23 23-3/4 35-15/16 18Cat. No. Size Code M N O P R S a b72520, 7252172530, 7253172620, 7262172630, 72631-0160-0200-0250-0310-040016-1/220-3/824-1/429-3/439-3/49-1/1611-11/1613-9/1618-1/822-7/1615-3/819-9/1622-13/1629-15/1636-13/165-11/167-11/168-1/410-5/812-3/165-13/167-1/28-7/1611-5/813-9/1612-3/814-1/216-5/820-5/1624810-1/1611-7/814-3/818-3/86-9/167-5/89-3/1612-3/1614-5/8INDUSTRIAL BLOWERS WITH BELT DRIVE—Dimensions (Inches)Cat. No. Size CodeINLET DIA., IN.I.D. A B E G H H1 K M72721, 72730 -0160 6-5/8 6 4-9/16 1/2 32-1/2 10 15-11/16 10 22-1/472731, 72821 -0200 7-3/4 7-7/16 5-1/8 1/2 32-1/2 14 21-11/16 10 22-1/472830, 72831 -0250 9-3/4 9-3/8 6-11/16 1/2 37-1/4 15-15/16 24-3/16 11-1/2 26-3/4-0310 12-3/4 11-7/8 9-11/16 1/2 46-13/16 20-15/16 31-9/16 13-1/2 32-1/4-0400 16 15-5/8 11-7/8 3/4 54-9/16 23-3/4 35-15/16 18 41-7/8Cat. No. Size Code N O P R S T a b72721, 7273072731, 7282172830, 72831-0160-0200-0250-0310-04009-1/1611-11/1613-9/1618-1/822-7/1615-3/819-9/1622-13/1629-15/1636-13/165-11/167-11/168-1/410-5/812-3/165-13/167-1/28-7/1611-5/813-9/1616-3/816-3/819-1/822-13/1626-1/814-7/8 +/- 1-1/214-7/8 +/- 1-1/216 +/- 1-1/220-1/2 +/- 1-1/222-7/8 +/- 1-1/2810-1/1611-7/814-3/818-3/86-9/167-5/89-3/1612-3/1614-5/8*Size codes for these blowers are available with all catalog numbers.PVC DUCT TO BLOWER CONNECTIONYou may attach PVC duct to the blower inlet and transition, or use the Saint-Gobain flexible connection.INLETLab INLET Standard Duct Size Type of Duct JointI.D. x O.D., IN.IN.OUTLETLab OUTLET Standard Duct Size Type of Duct JointI.D. x O.D., IN.IN.71300 Series71400 and71500 Series5-1/4 x 5-5/8Taper x 8Industrial INLET Standard Duct Size Type of Duct JointI.D. x O.D., IN.IN.-0160-0200-0250-0310-04006-1/4 x 6-5/87-3/8 x 7-3/49-3/8 x 9-3/412-3/8 x 12-3/415-5/8 x 166791216ButtsDucts insertsDucts insertsButtsButts58ButtsDucts slides over71300 Series71400 and71500 SeriesDir. = Direct Drive XP = Explosion-Proof TEFC = Totally Enclosed Fan-Cooled BELT = Belt Drive4 x 4-1/2Taper x 8Industrial OUTLET Standard Duct Size Type of Duct JointI.D. x O.D., IN.IN.-0160-0200-0250-0310-04006-1/4 x 6-5/88-1/4 x 8-5/810-3/8 x 10-3/413-5/8 x 1415-5/8 x 1668101416ButtsButtsButtsButtsButts48ButtsDucts slides over35


B L O W E R SBlower SpecificationsTransitions for Saint-Gobain Performance Plastics Industrial Blowers• Connect rectangular blower outletto circular ductwork• Permits fast, easy installation• Rigid, welded PVC• Flanges are drilled for blowers’bolt patternsCat. No. Size Code A B C D E F, G, Bolt HolesDuct I.D. Duct I.D.72510-016086-9/165-7/84-3/8116-5/86-1/414Fits Saint-Gobainindustrialblowers withthese size codes-0200-0250-031010-1/1611-7/814-3/87-5/89-3/1612-3/167-11/169-1/211-3/165-5/166-3/49-5/81112128-5/810-3/4148-1/410-3/813-5/8182222-040018-3/814-5/815-3/412131615-5/822Transitions for Saint-Gobain Industrial Blowers• Easily fit inlets and outlets oflaboratory blowers• Stainless steel clamps (two) suppliedfor quick, easy installation• Flexible PVC reduces excess vibration• 6" LengthConnector “A”—I.D. Connector FitsCat. No.(Inches)DuctOutletFlexibleConnector72511-005072511-005572511-010072511-016072511-020072511-020572511-025072511-025572511-031072511-031572511-04004-1/25-5/886-5/87-3/48-5/89-3/410-3/412-3/414165-inch lab blower (outlet)5-inch lab blower (inlet)8-inch lab blower (inlet and outlet)-0160 industrial blower (inlet and transition)-0200 industrial blower (inlet)-0200 industrial blower (transition)-0250 industrial blower (inlet)-0250 industrial blower (transition)-0310 industrial blower (inlet)-0310 industrial blower (transition)-0400 industrial blower (inlet and transition)*Transitions are needed to convert the rectangular industrial blower outlet to a round duct.Must be ordered separately (Cat. No. 72510).TransitionRectangularto RoundOutletInletLab BlowerDuctIndustrial BlowerDuctFlexibleConnectorInletDuct36


I N F O R M A T I O NTechnical InformationTechnical InformationFood Grade ResinsThe resins used in Saint-GobainPerformance Plastics low-density andhigh-density polyethylene tanks complywith 21 CFR Regulation 177.1520. Thesetanks may be used with the followingkinds of food products:• Nonacid, aqueous products; may containsalt or sugar or both (pH above 5.0)• Dairy products and modifications:oil-in-water emulsions, high or low fat• Moist bakery products with surfacecontaining no free fat or oil• Dry solids with the surface containingno free fat or oil (no end-test required)and under all conditions of use asdescribed in Table 2 of 21 CFR Regulation177.1520 except for condition A—high-temperature heat sterilization(e.g., over 100°C)Saint-Gobain Performance Plasticsrotomolded polypropylene complies with21 CFR 177.1520 (c) 3.1 Regulation. The resinused in Saint-Gobain PVDF tanks complieswith 21 CFR Regulation 177.2510.Plastic Products for BiotechnologyKnowing whether a plastic is toxic tocell cultures is critical to biotechnologyproduction. To test cytotoxicity, we submittedrepresentative molded resinsamples to an independent laboratory.Samples were evaluated utilizing an MEMElution Procedure, utilizing a W.I. 38 orMRC-5 cell line. This is a standard cytotoxicitytest for pharmaceutical, medicaldevices and ophthalmic products (thoughit typically utilizes an L929 cell line.)Dimensions and Wall ThicknessDimensional information contained inthis catalog is for reference only, for thepurpose of selecting product from thecatalog. There is no inference to tolerancesfor the listed approximate dimensions.For additional information, contactSaint-Gobain Performance Plastics.Physical Service CapabilitiesMaximum service temperature listingsrefer to temperatures that should not beexceeded for the materials utilized in thespecific product line. Many factors, suchas chemical resistance, specific gravity,external stresses, product geometry,environment and many others affectthe suitability of a particular product.For additional information, contactSaint-Gobain Performance Plastics.Environmental Stress-CrackingEnvironmental stress-cracking is thefailure of a plastic material in thepresence of certain types of chemicals.This failure is not a result of chemicalattack. Simultaneous presence of threefactors causes stress-cracking:• Tensile stress• A stress-cracking agent• Inherent susceptibility of the plasticto stress-crackingTensile StressesThese are set up during some moldingand fabrication processes. Environmentalconditions can add tensile stress,particularly if the tank is inadequatelysupported. Rotational molding createsparts that are virtually stress-free, sorotomolded tanks are less subject toenvironmental stress-cracking thanfabricated tanks. Use of an FRP casingwill minimize tensile stress from addedload and further decrease the likelihoodof environmental stress-cracking.Resins Non-Toxic to Cell Cultures Contact Saint-Gobain for details, 800-451-0770.Resin Color ProductHigh-Density Polyethylene (HDPE)Low-Density Polyethylene (LDPE)Polypropylene (PP)Polyvinylidene Fluoride (PVDF)NaturalNaturalNaturalNatural<strong>Tanks</strong><strong>Tanks</strong><strong>Tanks</strong><strong>Tanks</strong>Common Stress-Cracking AgentsDetergents, surface active chemicals,lubricants, oils, ultra-pure water andplating additives such as brightener andwetting agents.Relatively small concentrations of stresscrackingagent may be sufficient to causecracking. (Stress cracking agents are identifiedin the Chemical Resistance Chart.)Susceptibility to Stress-CrackingThis varies from plastic to plastic dependingon several characteristics of the molecularstructure. Cross-linked high-densitypolyethylene is inherently more resistantto stress-cracking than either low- or highdensitypolyethylene. PVDF also has excellentstress-crack resistance.Physical Service CapabilitiesProlonged use of a plastic tank at temperaturesabove ambient will shorten tanklife. Temperature effects are directlydependent on the characteristics of theplastic resin, specific gravity of tank contents,tank size and configuration, exteriorsupport, and wall thickness of the tank.Temperature cycling will shorten tank life.The impact resistance of most rotomoldedtanks declines at low temperatures.Cross-linked high-density polyethyleneretains much of its impact resistance inlow temperature applications.Ultraviolet (UV) StabilizationPlastics are attacked and deteriorate whenexposed to direct sunlight. When plastictanks absorb the sun’s ultraviolet light,the UV energy excites the polymers’ chains,causing them to break. The effects arediscoloration, embrittlement and eventualcracking. Elevated temperatures and oxygentend to accelerate the deterioration.Those Saint-Gobain Performance Plasticstanks listed as suitable for outdoor serviceare protected from UV attack by: coloringor pigmenting and/or adding internal stabilizerswhich preferentially absorb or dissipatethe UV energy. Shading tanks fromthe sun will also prevent deterioration.<strong>Tanks</strong> must be free to expand or contract;avoid excessive tension on the tank.37


I N F O R M A T I O NChemical StorageStorage of Sodium Hypochlorite (NaOCl) in Polyethylene <strong>Tanks</strong>Some concerns have been expressedto Saint-Gobain Performance Plasticsregarding the storage of sodiumhypochlorite in polyethylene tanks.Although polyethylene storage tankshave been used for storage of sodiumhypochlorite in the field for many years,there have been premature failures invery specific locales. We have reviewedall data available on the chemistry andtechnology of sodium hypochloritestorage, and we have the followinginformation:Sodium hypochlorite (NaOCI) has nodirect effect on polyethylene. This hasbeen confirmed by the resin suppliers.It is suspected however, that contaminatedsodium hypochlorite does causeaccelerated deterioration of polyethylenetanks when stored over a period of time.Contamination such as trace metals, e.g.iron, copper, etc., which may be generatedfrom pumps, plumbing, fittings, etc.,or a poor quality (trace contamination)sodium hypochlorite shipment, maycause brittleness and cracking of thepolyethylene tanks.We feel the main contributor to prematurefailure of polyethylene storage tanks iscontamination; the presence of sunlightcatalyzes/accelerates the rate of attack onpolyethylene. Saint-Gobain PerformancePlastics will only warrant tanks for thestorage of sodium hypochlorite if thefollowing specifications are met:• Heavy-walled tanks(bulk tanks, 1.9 specific gravity)• Cross-linked polyethylene (XLPE)We recommend the following stepsto be taken by the end user:• Flush/clean tanks periodically toremove contaminants and deposits• Check quality of received NaOCI(chemical analysis/purity)• Check plumbing, pumps and deliverymethods for materials of constructionWe wish to emphasize that non-contaminatedsodium hypochlorite storagein polyethylene is an acceptable andcompatible combination. It appears thatcracking and premature tank failuresoccur only when sodium hypochloriteis contaminated with trace amounts ofmetals and subjected to sunlight.A Guide To Using Saint-Gobain Performance Plastics <strong>Tanks</strong>With Most Common ChemicalsThe resins used in Saint-GobainPerformance Plastics tanks are highlyresistant to many chemicals. This chartwill assist in the selection of tank materialfor use with common chemicals.Mechanical stress, high temperatures,and extended use tend to multiply theeffects of chemicals on the tank.Such effects should be taken intoaccount when using Saint-GobainPerformance Plastics tanks for long-termchemical storage or with handlingequipment. Under normal conditions,chemicals rated “S” may be safely handledby the plastic material. Chemicalsrated “U” are not recommended forstorage in that particular material.This chart applies to tank materialsat temperatures from 70°F/21°C to140°F/60°C.Storage of flammables in plastic tanksmust conform to local fire codes.Mixing and/or dilution of certainchemicals in Saint-Gobain PerformancePlastics tanks can be potentially dangerous.The reactive combination ofdifferent chemicals or compounds oftwo or more classes may cause an undesirablechemical effect or result in anincreased temperature which can affectchemical resistance. Small amounts ofcertain chemicals can drastically changethe characteristics of the blend. Astemperature increases, resistance toattack decreases.Chemicals can affect the strength, flexibility,surface appearance, color, dimensionsor weight of plastics. The basicmodes of interaction which cause thesechanges are: (1) chemical attack on thepolymer chain, with resultant reductionin properties, including oxidation anddepolymerization;(2) physical change,including absorption of solvents, resultingin softening and swelling of theplastic; permeation of solvent throughthe plastic; dissolution in a solvent; andstress-cracking from the interaction of astress-cracking agent with molded-in orexternal stresses.NOTE: The chemical resistance informationin this chart is a general guide only. Becausemany factors can affect chemical resistance,you should test under your own conditions.If any doubt exists about specific applicationsof Saint-Gobain tanks, please contactSaint-Gobain Performance Plastics,I-295 at Harmony Road, Mickleton, NJ 08056 orcall (800) 543-8823,fax (856) 423-8182.ATTENTION: Please be aware that, althoughseveral plastics may have excellent resistanceto various flammable or combustiblechemicals or solvents, safety regulations forstorage or other local regulations may restrictstorage of these chemicals in tanks.38


I N F O R M A T I O NChemical ResistanceLLDPE/LDPE/ 316Description % Conc. HDPE XLPE1 PP PVDF FRP PVC EPDM NEOPRENE VITON® STAINLESS70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 70°F 70°F 70°FAcetaldehyde*AcetamideAcetic Acid*/**Acetic Acid*/**Acetic AnhydrideAcetone*†Acrylic Emulsions*AcrylonitrileAdipic AcidAlcohol:Allyl*Amyl*/**Bensyl*Butyl*Diacetone*Ethyl*Hexyl*Isobutyl*Isopropyl*Methyl*Propyl*Aluminum SaltsAluminum HydroxideAlums (All Types)Ammonia, Dry GasAmmonia, SolutionAmmonium SaltsAmyl Acetate*†Amyl ChlorideAniline*Antifreeze*/**Antimony ChlorideAqua Regia*Arsenic AcidBarium SaltsBenzadlehyde*Benzene*Benzene Sulfonic Acid*/**Benzoic AcidBlack Liquor 2BleachSee statement on NaOCI storage401-7980-100Conc.10%Conc.10030100100100801010All Conc.10U U— —U UU UU UU UU U— —S SU US S– –U U– –U U– –– –– –– –– –S S– –S SS SU US SU UU UU UU US SU US SS SU UU UU US SU UUU— —SSUUSSUUUU— —S SS SS S– –S S– –S S– –– –S US SS SS SS SS SS SS SS SU UU UUSSUSSUUSSSUSSUSSUUUSSU US UU UU UU UU UU US US SS SS US SS SS –S S– –– –S –S –S –S SS –S SS SS SS SU UU UU US US UU US SS SS UU US SS SS SU US US SS U– UU U– –S US SS SS SS SS SS US SS SS SS SS SS SS SS SS SU US SS SS US SS US SS US US SS SS US SS US SS SS SU U– –S SS UU UU US U– –S –S SS S– –S S– –S S– –– –– –– –– –S S– –S SS SS US SS US U– –S SS SU U– –S S– –S US SS SS SU U– –S SU U– UU U– –U US SU UU UU US –– –S SS SS –S SS SS SS SS SS SS SS SS SU UU UU US SS SU US SS SS S– –S S– –S SS –SSU–US–U––SUSS–SSSSSSSSSSSS–SS–U–SSU––SSUSU–SU–U––SUSSSS–SSSS–SSSSU–US–U–SUU–U–UUSU–SU–U––SSSUSSSSSSSSS–S–U–SSSUSSUSSSSSSSSSUS–SS–SSSSSSSSSSUSSS–U–––S–USSSU––––in Technical Data sectionBoraxBoric AcidBromine GasBromine LiquidBromine Water†ButadieneButaneButanediol*Butyl Acetate†Butyl Alcohol*ButyleneButyric AcidSatd.Conc.Weak Conc.10010010010080S SS SU UU UU U– –– –U UU UU U– –U US SS SU UU UU U– –– –S SS US S– –– –S SS SU UU UU U– –S –U UU UU U– –S SSSSSSSSSSSSSSSSSSSSSUSUSS SS SS S– –– –– –– –– –S US S– –S US –– –U UU UU UU UU U– –U U– –S SU USS–––SU–––U–SSUU––S–US––SSSSSSS––SSSSS––USS–S–S–See page 44 for chart and footnote legend.39


I N F O R M A T I O NChemical ResistanceLLDPE/LDPE/ 316Description % Conc. HDPE XLPE1 PP PVDF FRP PVC EPDM NEOPRENE VITON® STAINLESS70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 70°F 70°F 70°FCadmium SaltsCalcium SaltsCalcium Hypochlorite**Calgon (sodium hexmeta phosphate)*Camphor OilCarbon Bisulfide* (disulfide)Carbon Dioxide, wet/dryCarbon MonoxideCarbon Tetrachloride†Carbonic AcidCastor Oil*Caustic Soda*Caustic Soda*Chlorine Gas, DryChlorine LiquidChlorine WaterChloroacetic Acid*Chlorobenzene*†Chloroform*†Chlorosulfonic Acid*Chrome AlumChromic AcidChromic Acid**Chromic Acid & 50%Sulfuric Acid*/**Citric Acid*Coconut Oil DerivativesCottonseed Oil*Cresol*Cresylic AcidCupric SaltsCuprous SaltsCyclohexaneCyclohexanone*Detergents*Developers, PhotographicDextrinDextroseDiazo SaltsDiesel FuelDiethylamineDiethylene Glycol*Dioctylphthalate*Disodium PhosphateEmulsions, Photographic*Epsom Salts (Magnesium Sulfate)Ethyl Acetate*Ethyl Alcohol*Ethyl BromideEthyl Chloride†Ethyl EtherEthylene ChlorideEthylene Dichloride*Ethylene Glycol**Ethylene Oxide10010Conc.100Satd.100Satd.2050Satd.Satd.Satd.10010012S SS SS SU UU UU US SS SU US SU UU UU UU UU US UU UU UU UU US SS UU UU UU US SU UU UU US SS SU UU UU US SS SS SS S– –U UU UU US SU US SU UU UU UU UU UU UU UU UU USSSSUUSSUSSSSUUSUUUUSSSSSSSSUSSUUSSSSSSSSSSUUSSUSSSSUUUUUUUSSUUSSSUUSSUUSSSSSU– –SUSSSUSUUUUUSUSUSSSUSUUUUUSUS SS SS SU UU UU US SS SU US SU US SS –U UU UU UU UU UU UU US SU UU UU US SS SS SU UU US SS SU UU UU US SS SS SS SS US US UU US SU US SU US SU UU UU UU UU US US US SS SS SS S– –S US SS SS SS SS SS SU US SS SS SS US US UU US SS SS US US SS SS SS SS SS SS SS SS US SS SS SS S– –S SS U– –U US SS SS SU US SS SS SS US SS SS SS US SS SS S– –– –– –S SS SU US S– –– –S US S– –S SS US U– –– –– –– –– –U US SS SS S– –– –– –– –S SS US SS SS S– –– –S SS SS SS U– –– –S S– –S U– –– –– –S S– –– –S S– –– –– –U US SS SU US SS SS SS SU UU US SS UU UU UU US SS UU UU US SS SS SU US US SS SU UU US SS SS SS SS SS UU U– –U US SS SS SU US SU UU UU UU UU US SU U–S–––U––US–SSU––SUUUSUUU––SUUSSU–––SS–UU––––S–––S–UUSUSUUS–USSUSSSSUUUSUUUSUUUSSSUUSSU–S–SS–USSU––SUS–UUUUSUSSS––SSSSSSS–S––USSUUSSUSSSSSSSS–S–SS–SU––S–S–SSS–SSSU–S–SSUSSSSSSU–––USSUSSSUSS–SSUUSSSS–––SSSSS–SSSSSSSSS–40See page 44 for chart and footnote legend.


I N F O R M A T I O NChemical ResistanceLLDPE/LDPE/ 316Description % Conc. HDPE XLPE1 PP PVDF FRP PVC EPDM NEOPRENE VITON® STAINLESS70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 70°F 70°F 70°FFatty Acids*Ferric ChlorideFerric SaltsFerrous SaltsFish Solubles*Fluoboric AcidFluorine, DryFluosilicic Acid32Fluosilicic AcidConc.Formaldehyde*/**40Formic Acid*100Freon 11Freon 113Freon 12FructoseSatd.Fruit JuiceFruit Pulp*Fuel Oil*Gallic Acid*Satd.Gasoline*†GelatinGin*GlucoseGlue, P.V.A.Glycerol*Glycolic Acid*30Glycols*/**Gold MonocyanideGrape JuiceGrape SugarSatd.GreaseHeptane*†Hexane*†HoneyHydraulic Oils (Petroleum)Hydraulic Oils (Synthetic)HydrazineHydrobromic Acid37Hydrochloric Acid 420Hydrochloric Acid 437Hydrocyanic AcidSatd.Hydrofluoric Acid50Hydrofluoric Acid75Hydrofluosilicic Acid32Hydrofluosilicic AcidConc.Hydrogen100Hydrogen Chloride Gas, DryHydrogen Peroxide30Hydrogen Phosphide100Hydrogen SulfideHydrogen Sulfide, Aqueous Sol’nHydroquinoneHypochlorous AcidConc.Inks*IodineIodine (K Solution)Conc.U US SS SS SU US SU US SS UU UU U– –– –S US SS SU UU UU UU US SU US S– –U UU UU US S– –S SU UU UU US SU UU U– –S SS SS SS SS U– –S SS US SS SS SS SS SS SS SS SU U– –U USee page 44 for chart and footnote legend.SSSSSSUSSSSSSSSSSUSUUS– –– –SSSSSSSSSSUSSSUSUSUS– –SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSUUSUUSSSSSSSSSSSSSSSSSS– –U US US SS SS SU US SU US SS US US U– –– –S US SS SS SU US SU US –S SS SS –S SS SS US S– –S SS UU UU US SU UU U– –U US SS SS SS –S –S SS US SS SS U– –S SS US SS SS SU UU US SS SS SS S– –S SS US SS SS US SU US SS SS SS SS SS SS US SS SS SS SS SS SS US SS SS SS SS SS SS SS SS US US SS SS SS SS SS SS SS SS SS SS SS SS US SS SS SS US US S– –S SS SS SS SS SS SU US US US US U– –– –– –S S– –S SS S– –S S– –– –S S– –S SS SS SS S– –S S– –S SS US SU UU U– –U U– –– –S –– –– –S US US SS SS S– –S S– –– –S S– –– –– –S US SS SS SS SS SU US S– –U UU UU US SU US SS SS SS SS SS US S– –S S– –S US S– –S SS SS SS SS SU US SU UU UU US US SS SS SS UU US SS SS S– –S –S SS SS SS SS S– –U U– –USSS–––––SSUU–SUUU–US–S–S––––––UUSU–S–SUSUU––S–S–SS–––U–USSS–S–––SSSSSSUSSSUS–SSS––SS–UUUSSUS–SUSSU––S–S–SUU––U–SSSS–SSSSSUUUUSSSSSSS–SSSS–SSSSSSSUSSSSSSSSSSS–S–SSSS–S–SUU––US––S–SS–SSSS–SS–SSSSSSS–SSSSSSSUUU–UUS–S–S–SS––SU–41


I N F O R M A T I O NChemical ResistanceLLDPE/LDPE/ 316Description % Conc. HDPE XLPE1 PP PVDF FRP PVC EPDM NEOPRENE VITON® STAINLESS70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 70°F 70°F 70°F42Isopropyl Alcohol*Isopropyle EtherIsooctaneJet Fuel (JP3,JP4,JP5)Kerosene*KetonesLactic Acid*90Lard OilLatex*Lead AcetateSatd.Lime30Linseed Oil*Lube Oil*Magnesium SaltsMaleic AcidMercuric SaltsSatd.Mercurous SaltsSatd.MercuryMethyl AcetateMethyl Alcohol*100Methyl BromideMethyl Butyl KetoneMethyl CellosolveMethyl Chloride*Methyl Isobutyl KetoneMethyl Ethyl Ketone*† 100Methyl MethacrylateMethyl Sulfuric Acid*MethylamineMethylene Chloride*100MilkMineral OilsMolassesComm.Naphtha*Naphthalene*Nickel SaltsNicotine*DiluteNicotinic Acid*Nitric Acid**0-29Nitric Acid**30-49Nitric Acid**50-69Nitric Acid**70-98Nitrobenzene*100Oils*EssentialMineralVegetableLubricatingOils and Fats*Oleic AcidConc.OleumOrange ExtractOxalic AcidSatd.OzonePalmitic AcidParaffinU U– –– –– –U U– –U UU UU US S– –U UU US SS US SS SS S– –U UU U– –– –U U– –U U– –U U– –U US SU US SU UU US SU UU US SS UU UU UU U– –– –– –– –U UU UU US SS UU US U– –See page 44 for chart and footnote legend.S U– –– –– –S U– –S US US SS SS SS US US SS US SS SS S– –S SU U– –– –U U– –U U– –S U– –U US SS US SU UU US SS SS SS SS UU UU UU U– –S US US US US UU US SS UU US U– –S U– –– –S US US –S UU US SS SS US SS US SS US SS SS S– –S SU UU US UU UU US U– –S U– –U US SS US SS US US SS SS SS UU UU UU UU U– –– –– –– –S US UU US SS SU US US US SS US SS SS SU US US U– –S S– –S SS SS SS SS SS SS SS US SS SU US SS SU UU US US UU UU US SS SS SS SS SS SS US SS US UU UU US US SS SS SS SS SS SU US SS US SS SS S– –– –– –– –S S– –S S– –– –S S– –S S– –S S– –S SS SS S– –S U– –– –– –– –– –– –– –S S– –– –– –S SS SS SS SS S– –– –S US U– –U U– –– –– –– –– –S SS S– –– –S S– –S S– –S U– –– –S US UU US –S U– –S SS US SS US SS SS SS SS SU US UU UU UU UU UU UU US –S UU UU US SS US SS UU US SS SS SS SU UU UU UU U– –S US US US US UU U– –S US US US USUSUUSSU––S––SUSSSUSUSUUUSU–––S–UUU––––U––S–––––UU––U–USUSUUUSUU–SS–SUSSSUSUUUUUUU––USS–UUS––UUUUUUSSSSUU–S–––SUSSSUSSSSSSSSSSSSUSSUUSU–U–––SS–SSS––SSSUU–SSSSSS–SSSSSSSSSS–SS––SSSSU–SSSSSSSSS––S–SSSSSU––SSS–SSSSSSS–––SSS


I N F O R M A T I O NChemical ResistanceLLDPE/LDPE/ 316Description % Conc. HDPE XLPE1 PP PVDF FRP PVC EPDM NEOPRENE VITON® STAINLESS70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 70°F 70°F 70°FPentanePerchloric AcidPerchlorethylenePhenol Carbolic AcidPhosphoric AcidPhosphoric AcidPhosphorus PentoxidePhosphorus TrichloridePhotographic Solutions*Pickling Baths, Hydrochloric Acid*Pickling Baths, Sulfuric Acid*Pickling Baths, Sulfuric-Nitric*/**Picric Acid*Plating SolutionsWithout Wetting Agents**10550851001001– –S SU US US SS US UU US UU UU UU UU US U– –SUSSSSSUUSSU– –SSSSSSSSSUUU– –S SU US SS SS US UU US SS SS SS US US U– –S SS SS SS SS SS SS SS S– –– –– –S US U– –S U– –– –S SS S– –– –S US SS SS US SS U– –S UU US US US US –U US S– –– –U UU US UU–UUSS––––––U–U–UUSS––S–––SSSSSSSS––––SSSSUUS–S––S–––––SPotassium SaltsPotassium Hydroxide*PropanePropyl Alcohol*Propylene Glycol*Pyridine*Pyrogallic AcidRayon Coagulating Bath*Selenic AcidShortening*Silicic AcidSilver SaltsSoap Solution*Soda AshSodium SaltsSodium Hexametaphosphate*Sodium Hydroxide*Sodium Hydroxide*Sodium Hypochlorite**See NaOCI Storage statement, Pg 38.0-10Any Conc.10Conc.S SU U– –U UU UU U– –U US SU US SS SU US SS SU UU UU UU US SS U– –S SS SS U– –S SS SS SS SS SS SS SS SS SS SS SS SS SS U– –S SS US SS US SS US SS SS SU US SS SU US SS –U US SS US S– –S SU US U– –S S– –S SS SS US SS S– –S SU US SS SU U– –– –S S– –– –– –– –– –S SS SS SU US S– –– –S US SS SS SS US U– –U US US SS S– –S SS SS SS SS S– –S SS SS –SSU––U–––––SSSS–SSSSUSSUU–––––SSSSSSSUSSSSSUS–––SSSSS–S–S–USSSUS––––SSSSSSUUSour Crude*Stannic SaltsStannous SaltsStarch SolutionStearic Acid*Stoddard’s SolventStyrene MonomerSulfurSulfur ChlorideSulfur Dioxide**Sulfuric Acid 3 **Sulfuric Acid 3 **Sulfuric Acid 3 , 5 **Sulfuric Acid 3 , 5 **Sulfuric Acid, Fuming* 3 /**Sulfurous AcidTallowTannic Acid*Tanning Liquors*Tartaric AcidTetrachlorethaneSatd.1000-4951-7475-9596-98Conc.Conc.Satd.U US SS SS SU U– –– –S UU US US SU UU UU UU US SS UU U– –S SU USSSSSUSSSS– –– –SUSSSSUUSSSSSUUUUSUUUUSUSSSUS US SS SS SS SU U– –S UU US US SS UU U– –U US SS US S– –S SU USSSSSSSSSSSSSSUSSSSSSSSSSSSSSUSSSUUUSSSUSSS SS SS SS SS S– –– –– –– –S SS S– –– –– –– –S S– –S S– –S S– –S SS SS SS SU UU UU UU UU UU US SS SU UU UU US S– –S SS SS S– ––SS––UUSUS–UUUUU––––U––S–SUUSUSSUUUUU–S–SUSSSSSSSSSSSSSSSSSS–SS–––SSSSSUSUUUU––SSS–SSee page 44 for chart and footnote legend.43


I N F O R M A T I O NChemical ResistanceLLDPE/LDPE/ 316Description % Conc. HDPE XLPE1 PP PVDF FRP PVC EPDM NEOPRENE VITON® STAINLESS70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 140°F 70°F 70°F 70°F 70°FTetrahydrofuran*Thionyl ChlorideToluene*†Transformer Oil*TrichloroethyleneTrisodium PhosphateTurpentine*Urea*UrineVanilla Extract*Vinegar* (4-8% of Acetic Acid)Water, Acid, MineWater, DistilledWater, DeionizedWater, FreshWater, SaltWetting Agents*Whiskey*White Liquor (Pulp Mill)White Water (Paper Mill)WInesXylene*†YeastZinc SaltsSatd.Conc.U UU UU UU UU US SU UU US SU UU U– –– –U US SS SU UU U– –– –S SU US SS SUUUSUSUSSSSSSSSSSSUUUUUSUSSSSSSUSSSS– –– –SUSSSUSSU UU UU US UU US SU US SS SS SS SS -S SS SS SS SU US SS –S –S SU US SS SU UU US S– –S US SS SS SS S– –S SS US SS SS SS SS SS SS U– –S SS SS SS S– –– –S U– –S SS SU US SS S– –S S– –– –– –S SS SS S– –– –– –– –U US SS SU UU UU UU UU US SU US US S– –S SS SS SS SS SS S– -–S SS S– –S SU U– –S SU–U–USU–S–S–SSSS–S–––USSU–U–USU–U–SUSSSS-SSS–USSU–S–SSS–S–SSSSSS–SSSSSSSSUSSS–SSS–SUSSSU–SSS–S––Legend44S – SatisfactoryU – Unsatisfactory- – No Test Data* – These chemicals can cause stress-crackingof LLDPE, LDPE and HDPE under certainconditions. Rotomolded tanks are essentiallystress-free and are not usuallyaffected by stress-cracking chemicals.However, these chemicals may affect theservice life of tanks with welded fittingsor seams, and unsupported tanks operatingunder heavy loads. Use XLPE tankswhich have excellent environmentalstress-crack resistance.** – Limited Warranty one year—see page 45.+ – Permeation by this solvent may causesoftening, swelling and/or considerableloss of fluid in polyethylene tanks.1 – XLPE exhibits high environmentalstress-crack resistance, but available datais limited and tests are recommended forsevere conditions or chemicals not listedin this chart.2 – Mostly satisfactory, but black liquor variesconsiderably in composition and temperature.Field testing is recommended.3 – Use of Sulfuric Acid may cause initialdiscoloration of interior tank wallsurface due to oxidation.– Refer to Chemical Resistance Chart forfittings and gaskets.4 – Vapors from Hydrochloric Acid areextremely aggressive. When storing thisproduct, please make sure you haveinstalled an appropriate scrubbing systemor specify a bolted and gasketedmanway cover with plastic bolts.Contact Saint-Gobain for pricing.5 – For Bulk Storage of Sulfuric Acid concentrationsbetween 80%-95% please specifyXLPE <strong>Tanks</strong> designed for 2.2 specificgravity.We recommend this heavier walltank due to the stress-cracking and oxidizingnature of this chemical. ContactSaint-Gobain for pricing on these tanks.WARNING: Misuse of Saint-Gobain productscan be potentially dangerous. Before usingthis product, please refer to the appropriateSaint-Gobain catalogs/inserts and the variouswarnings, information, instructions and chemicalresistance chart. If any doubt exists about aspecific use of Saint-Gobain products, pleasecontact Technical Support, Saint-GobainPerformance Plastics, 1044 MacArthur Rd.,Reading, PA 19605 or call (800) 451-0770,fax (610) 376-4802.MaterialsLLDPE—Linear Low-Density PolyethyleneLDPE—Low-Density PolyethyleneHDPE—High-Density PolyethyleneXLPE—Cross-Linked High-Density PolyethylenePP—PolypropylenePVDF—Polyvinylidene FluorideFRP—Fiberglass-Reinforced PolyesterPVC—Polyvinyl ChlorideEPDM—Ethylene Propylene Diene MonomerNEOPRENE—A chloroprene polymer,synthetic rubberVITON® —A fluoroelastomer, registeredtrademark of E.I. du Pont de Nemours andCompany, Inc.


I N F O R M A T I O NWarranty and How to OrderHow to Order Saint-Gobain <strong>Tanks</strong> and AccessoriesSaint-Gobain Performance Plastics tanksand other products are available fromauthorized Saint-Gobain PerformancePlastics Distributors throughout the U.S.,Canada and Puerto Rico.Always order by complete catalog number(first four or five digits) and size code(last four digits). Be sure to include a briefproduct description and drawing showingthe location of installed fittings, wherenecessary. For example: one each 11100-0005 cylindrical tank and one each 93857-0050 nipple installed through side.Drawings are required when fittings areto be factory installed.• Covers: Covers are included with tanks,and are sold as part of a complete package—TANK/COVERCOMBINATION.• Freight: All shipments are F.O.B.Reading, Pennsylvania; Garrett, Indiana;or other distribution points.• Applications: Saint-Gobain PerformancePlastics records application details forall bulk tank orders. This informationensures correct usage of bulk tanks andsupports the Saint-Gobain warranty.Please submit the following with allbulk tank orders:• Chemicals and concentration• Service temperatures• Specific gravity of contentsNOTE: Many Saint-Gobain PerformancePlastics Distributors stock Saint-GobainPerformance Plastics tanks. Please check withthe Saint-Gobain Performance PlasticsDistributor in your area for potential freightsavings.For assistance, call your nearest Saint-GobainPerformance Plastics Distributor orSaint-Gobain at (800) 451-0770.• Delivery: Standard tanks are generallyavailable for prompt delivery fromstock. If your order is unusual in quantity,size or fittings required, or if itinvolves a major installation, pleasecontact Saint-Gobain PerformancePlastics for delivery information.• Return Goods Procedure: No materialwill be accepted for return withoutwritten authorization. Authorizedreturns must carry a Saint-GobainPerformance Plastics “AuthorizedReturn” label on the outside of thecarton. These labels are available fromSaint-Gobain Performance Plastics.A certificate of safe handling is alsorequired. Specially fabricated or factorymodifiedtanks may not be returned forcredit.NOTE: Plastic tanks which are subject tochemical, physical and/or thermal exposureshould be inspected on a routine basis for anysigns of leaking, cracking, discoloration,bulging or other deviations from the “as new”condition. The frequency of inspection will behighly dependent upon actual use conditions,as well as the age of the tank. Specific guidelinesmust be determined by the user dependentupon actual use conditions. Saint-Gobaincannot provide specific guidelines due to thewide variety of applications and their effectson plastic tanks. Please consult this catalog orcontact Saint-Gobain for more information.Limited Warranty1. Saint-Gobain Performance Plastics herebywarrants that its products are free fromdefects in material and workmanship and thatthe products, provided they are installed inaccordance with printed instructions and usedwith chemicals listed as satisfactory in thechemical resistance chart at the temperaturesnoted in the Catalog, will perform satisfactorilyunder normal use and service in the hands ofthe original user.2. The above warranty by Saint-GobainPerformance Plastics shall expire one (1) yearfrom the date the product is shipped to thebuyer from the factory for all products exceptthose listed below for which the duration ofSaint-Gobain Performance Plastics’ warrantyshall be two (2) years from the date the productis shipped to the buyer from the factory:• All vertical storage tanks-550through 6,500 gallons• All conical-bottom tanks-1,575through 4,200 gallonsNOTE: If these tanks are used to store thefollowing: acetic acid, amyl alcohol, benzenesulfonic acid, ethylene glycol, formaldehyde, glycol,nitric acid, pickling baths with sulfuric andnitric, plating solutions, sulfuric acid, sodiumhypochlorite, calcium hypochlorite, chromic acid(1% to 50% concentration), or chromic acid/sulfuricacid-50%, the warranty is only one year.3.All products that are customized or structurallymodified at the factory by customerrequest have a one (1) year warranty periodfrom the date the product is shipped to thebuyer from the factory, except those productsfor which a longer warranty period is specificallyprovided in writing by Saint-Gobain attime of shipment. This warranty is void if thecustomer or someone other than Saint-GobainPerformance Plastics modifies Saint-GobainPerformance Plastics products.4.Hardware, fittings and steel accessories havea one (1) year warranty period from the datethe product is shipped to the buyer from thefactory. The warranty does not extend to productsinstalled by the customer.5.THE WARRANTY STATED HEREIN IS THE SOLEWARRANTY APPLICABLE TO SAINT-GOBAINPERFORMANCE PLASTICS PRODUCTS.SAINT-GOBAIN EXPRESSLY DISCLAIMS ANYAND ALL OTHER WARRANTIES EXPRESSEDOR IMPLIED, INCLUDING WARRANTIES OFMERCHANTABILITY OR FITNESS FOR APARTICULAR USE.6.In the event of a breach by Saint-GobainPerformance Plastics of its warranty,Saint-Gobain Performance Plastics will, at itsoption, either repair or replace the product(FOB factory) or refund its purchase price.<strong>Tanks</strong> over 500 gallons must be inspected onsite by an authorized Saint-GobainPerformance Plastics representative beforeSaint-Gobain can be required to honor anywarranty claim. Saint-Gobain PerformancePlastics shall provide written instructions onthe handling of any other warranty claim.7.SAINT-GOBAIN PERFORMANCE PLASTICSLIABILITY WITH RESPECT TO ITS PRODUCTSIS EXPRESSLY LIMITED TO THE REMEDIES SETFORTH ABOVE. THE REMEDIES ARE THEBUYER’S EXCLUSIVE REMEDIES. SAINT-GOBAINPERFORMANCE PLASTICS SHALL UNDER NOCIRCUMSTANCES BE LIABLE FOR INCIDENTALOR CONSEQUENTIAL DAMAGES.WARNING: All Saint-Gobain PerformancePlastics tanks are designed for atmosphericstorage of chemicals and should not be used forpressure, vacuum or direct burial applications.45


Manufacturing FacilitiesSaint-Gobain Performance PlasticsP.O. Box 3660, 2664 Gilchrist RoadAkron, Ohio 44305Tel: (800) 798-1554, (330) 798-9240Fax: (330) 798-6968TYGON ® Brand Flexible TubingSaint-Gobain Performance Plastics3910 Industrial DriveBeaverton, Michigan 48612Tel: (888) 387-0067, (989) 435-9533Fax: (989) 453-2355TYGON ® Brand Extruded Siliconeand Molded ComponentsSaint-Gobain Performance Plastics460 Milltown RoadBridgewater, New Jersey 08807Tel: (800) 435-3992, (908) 218-8888Fax: (908) 218-9009Flexible Components, ReSeal ® ,Sani-Tech ® ProductsSaint-Gobain Performance PlasticsI-295 @ Harmony RoadMickleton, New Jersey 08056Tel: (800) 543-8823, (856) 423-6630Fax: (856) 423-8182Chemfluor ® Tubing, Roll Cover,Engineered Extrusions, <strong>Tanks</strong>Saint-Gobain Performance Plastics150 Dey RoadWayne, New Jersey 07470-4669Tel: (973) 696-4700Fax: (973) 696-4056Chemware ®Saint-Gobain Performance Plastics40 White Lake RoadSparta, New Jersey 07871Tel: (800) 988-4876, (973) 579-1313Fax: (973) 579-3908Sani-Tech ® Brand Silicone ProductsSaint-Gobain Performance PlasticsLa Mothe-aux-AulnaiesF-89120 Charny FranceTel: (33) 3-86-63-78-78Fax: (33) 3-86-63-77-77Silicone Products, Hose AssembliesSaint-Gobain Performance PlasticsP.O. Box 1344, 11 Sichio DrivePoestenkill, New York 12140Tel: (518) 283-5963Fax: (518) 283-1418Specialty ClosuresSaint-Gobain Performance Plastics2316 West Wisconsin StreetPortage, Wisconsin 53901Tel: (800) 236-7600, (608) 742-8541Fax: (608) 742-3179Specialty Molded Silicone ComponentsSales OfficesSaint-Gobain Performance Plastics198 Beidou RoadMinhang Economic & TechnicalDevelopment CenterShanghai, China 200245Tel: (86) 21-6462-2800Fax: (86) 21-6462-2781Saint-Gobain Performance Plastics19801-5, Haramura, Suwa-gunNagano 391-0100 JapanTel: (81) 26679-6400Fax: (81) 266-70-1001Saint-Gobain Performance Plastics6th Floor, Donghsin Building141-30, Samsung-DongKangnam-Ku Seoul Korea 135-090Tel: (82) 2-508-8200Fax: (82) 2-554-1550Saint-Gobain Performance PlasticsSuite 1203, 147 Chienko North Road,Section 2Taipei, Taiwan R.O.C.Tel: (886) 2-2503-4201Fax: (886) 2-2503-4202Saint-Gobain Performance PlasticsKuala Lampur Representative OfficeNo. 18,Ground Floor, Jalan PJS 11/7Subang Technical Industrial Park,Bandar Sunway46150 Petaling Jaya, Sealngor D.E.,MalaysiaTel: (60) 3-736-4082Fax: (60) 3-736-4099Saint-Gobain Norton KK,Performance Plastics3-7,Kojimachi, Chiyoda-ku,Tokyo 102-0083 JapanTel: (81) 3-3263-0285Fax: (81) 3-3263-0286Saint-Gobain Performance PlasticsI-295 @ Harmony RoadMickleton, New Jersey 08056USATel: (800) 543-8823, (856) 423-6630Fax: (856) 423-8182www.plastics.saint-gobain.comSaint-Gobain Performance Plastics700 Warner Blvd.Taunton, Massachusetts 02780Tel: (508) 823-7701Fax: (508) 823-1438Specialty Extruded andMolded Silicone ProductsTYGON, ReSeal, Chemfluor, Sani-Tech, Chemware and Norton are registered trademarks.Viton is a trademark of E.I. du Pont de Nemours and Company.LuerLok is a registered trademark of Becton Dickinson.FLS-3068-20M-0702-SGCS www.plastics.saint-gobain.com ©2002 Saint-Gobain Performance Plastics Corporation

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!