12.07.2015 Views

Sanitary Tanks

Sanitary Tanks

Sanitary Tanks

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

S A N I TAR Y V E S S E L S<strong>Sanitary</strong> Tank MixersBioTech Mixing SystemsMIXER OVERHEAD DRIVECAT. NO.2653Pre-engineered, ready-to-use mixerpackages, Saint-Gobain PerformancePlastics BioTech mixer overhead drivesand lower assemblies/shafts and impellershave been specially designed to delivermaximum mixing efficiency. Each componenthas been carefully chosen tomatch a specific Saint-Gobain PerformancePlastics mixing vessel. Use them withthe closed-dome bio tanks (Cat. No. 2650)and sanitary conical-bottom processingtanks (Cat. Nos. 2690/2691). Requires2" sanitary connection (2661-0200) at10°< (for conical units), 2" silicone gasket(2672-0200) and true union (2670-0200).Saint-Gobain Performance Plastics vesseland mixer packages are designed for liquidsand liquid slurries only. Saint-Gobaindoes not warrant them for any specificapplication, only general-purpose mixingup to these maximum limits:• Solids—20% by weight• Specific Gravity (batch)—1.2• Viscosity—500 centipoiseBioTech Mixer Overhead DrivesOverhead drives are available in twopower configurations—1/20 HorsePower and 1/8 Horse Power.Both Drives Feature:• Autoclavable in-place• Variable speed controls for betteraccuracyCat. No. 2653 -0001 -0002Electrical requirementsPower (W)RPMHPLOWER ASSEMBLY/SHAFTCAT. NO.2654115V/60 Hz/1 PH4020-2501/20115V/60 Hz/1 PH11520-1401/8Lower module allows for use with 110/220 v, 50/60 Hz and accepts a universallyavailable power cord.NOTE: Lower assemblies/shafts and impellers and mixer support (required for closed-dome tanksonly) are necessary to complete each system and are sold separately (see Cat. Nos. 2654 and 2651).• Programmable timers for hands-offcontrol• LCD readouts for speed, power, torque,impeller flow and time• Audible overload alarm1/20 H.P. (Cat. No. 2653-0001)• 75-liter closed-dome tanks• 30- and 50-liter sanitary conicalbottomprocessing tanks1/8 H.P. (Cat. No. 2653-0002)• 30-, 50-, and 100 gallonclosed-dome tanks• 100-liter sanitary conical-bottomprocessing tanks• 200-liter sanitary conical-bottomprocessing tanks• Can be used interchangeablywith all sanitary units under 200L.Lower Assemblies/Shaftsand Impellers• For use with overhead drive• 316 stainless steel shaft• 316 stainless steel axial-flow impellers• Autoclavable• Encapsulated assemblies available—non-metallic wetted surfaces• Attaches to 2" connection withtrue union and gasketLOWER ASSEMBLIES/SHAFTS AND IMPELLERSCat. No. For Use With Overhead* Drive Shaft Length Shaft Diameter Impeller Diameter ImpellerCat. No. (in., mm) (in., mm) (in., mm) Material2654-0030†30-gallon closed-dome bio tank (2650-0030)2653-000230; 7621/2; 136.8; 173Stainless Steel2654-003130- and 50-L sanitary conical tanks(2690/2691-0030, -0050)2653-000117; 4321/2; 136.1; 155Stainless Steel2654-0055†55-gallon closed-dome bio tank (2650-0055)2653-000232; 8131/2; 138.8; 224Stainless Steel2654-0075†75-L closed-dome tank (2650-0020)2653-000123; 5841/2; 136.3; 160Stainless Steel2654-0101100-L sanitary conical tank (2690/2691-0100)2653-000228; 7111/2; 136.1; 155Stainless Steel2654-0100†100-gallon closed-dome bio tank (2650-0100)2653-000238; 9651/2; 1310; 254Stainless Steel2654-0201200-L sanitary conical tank (2690/2691-0200)2653-000236; 9141/2; 138.8; 225Stainless Steel22* The 2653-0002 is appropriate for use with all tanks. †Requires mixer support (2651-0200).

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!