Gate <strong>Valves</strong>1<strong>Baker</strong><strong>maric</strong> <strong>flow</strong><strong>control</strong> <strong>valves</strong>premier <strong>valves</strong> (Pty) LtdA - P.O. Box 11735, Randhart, South Africa, 1457 W - www.premier<strong>valves</strong>.co.zaT +2711-908-3760 F +2711-908-1268 E - sales@premier<strong>valves</strong>.co.za


2 <strong>Baker</strong> Maric Flow Control <strong>Valves</strong>Ever since water has been piped there has been adefinite need for a practical, accurate, self cleaningand inexpensive form of automatic <strong>flow</strong> <strong>control</strong>. The“<strong>Baker</strong> Maric Flow Control Valve” was developedto fill all these requirements and more.The <strong>Baker</strong> Maric Flow Control Valve has been usedsuccessfully in many countries since 1960 to give aCONSTANT FLOW irrespective of changing waterpressures. The initial valve cost is quickly recovered byreducing wastage of a valuable natural resource.In the South African Mining Industry the <strong>Baker</strong> Maricis used exclusively as a water saving device. TheWafer pattern fits in between flanges and is totallytamper proof and can handle dirty service water.The <strong>Baker</strong> Maric Flow Control consists of:• A precision moulded flexible <strong>control</strong> ring• A precision machined recess to accept the <strong>control</strong> ring.• Body manufactured to rigid engineering standards.PRINCIPLE OF OPERATIONThe flexible <strong>control</strong> ring is made from “Nitrile Butadine Rubber”meticulously compounded to pass exacting <strong>flow</strong> tests. The body of thevalve may be constructed of various materials including Brass, PVCand Stainless Steel.Accuracy: 10 %HIGH PRESSUREFlexible ring rollsdown tapered seatunder pressuredecreasingorifice, givingconstant <strong>flow</strong>.LOW PRESSUREFlexible ring innormal position.Maximum orifice.IDENTIFICATIONAll <strong>valves</strong> are stamped with rate of <strong>flow</strong> in litres per minute, and anarrow indicating direction of <strong>flow</strong>.PROPERTIES• Self cleaning - the flexing of the <strong>control</strong> ring during operationprevents the build up of mineral salts and rust flakes.• Odour free, taste free and non toxic.• Life expectancy - in excess of ten years• Automatic - responds instantly to changes in water pressure.• Self regulating - install and forget.• Economical - low initial cost is quickly recovered.• Compact - easily installed• Maximum operating temperature of 75ºC.• Standard maximum operating pressure 16 bar.(Higher pressure available on request)EXAMPLES OF APPLICATIONIrrigation, multi-storey buildings, homes, schools, Industrial -commercial and mining.CONCLUSIONWater is rapidly becoming more and more expensive. Start savingtoday by installing <strong>Baker</strong> Maric Flow Control <strong>Valves</strong>.The illustrations in this catalogue are subject to modifications without notice.premierP.O. Box 11735, Randhart, South Africa, 1457sales@premier<strong>valves</strong>.co.za<strong>valves</strong> (Pty) LtdT +2711-908-3760 F +2711-908-1268www.premier<strong>valves</strong>.co.za


<strong>Baker</strong> Maric Flow Control <strong>Valves</strong>3Product DataScrewed TypeF.F available in all sizes. Other configurations inlimited sizes only. First figure denotes inlet.Available in: DR Brass, Chrome,Gunmetal, UPVC, 303, 304, 316 SSSelect desired <strong>flow</strong> rate from‘Flow rate data’ at bottom of page.Sizes: 1/8”, 1/4”, 3/8”, No 15(½”), No 20(3/4”),No 25(1”), No 32(1 1/4”), No 40(1 ½”),No 50(2”)(Max.<strong>flow</strong> L/M): 9, 9, 9, 23, 54, 114, 233, 233, 342Wafer TypeDesigned for mounting between flanged pipe fittings.Any drilling. Flow rates available from 0.4 liters / minute up tothe maximum listed below:Available in: UPVC, ABS (plastic), Lg2 Gunmetal & 316 SSWafers are supplied with an o’ring in each facefor sealing. 65mm x 4 orifice wafer shown.Sizes: 25, 32, 40, 50, 65, 80, 100, 150, 200, 250, 300(Max.<strong>flow</strong> L/M): 233, 233, 233, 342, 456, 699, 1279, 2320, 4427,6058, 8854Standard Wafer O.D. Is located by flange bolts.Full Flanged Wafer to order.Insert TypeAvailable in various materials and <strong>flow</strong> rates from0.4L/M upwards in various types including :Flanged insert:Tap Insert:Plain insert:For water meter <strong>flow</strong> <strong>control</strong>.Fitted into 13 to 40mm tails.For screwing into existingtapware. Flows up to 9 L/M.Various applications includingpress fitting into OEM’sEquipment.The illustrations in this catalogue are subject to modifications without notice.premierP.O. Box 11735, Randhart, South Africa, 1457sales@premier<strong>valves</strong>.co.za<strong>valves</strong> (Pty) LtdT +2711-908-3760 F +2711-908-1268www.premier<strong>valves</strong>.co.za


4<strong>Baker</strong> Maric Flow Control <strong>Valves</strong>Flow Rate Data (Flexible <strong>control</strong> rubber sizes, in litres/minute)SizesNo 6 seriessuits 1/8” & largerscrewed bodiesNo 15 seriessuits ½” & largerscrewed bodiesNo 20 seriessuits ¾” & largerscrewed bodiesNo 25 seriessuits 1” & largerscrewed bodiesNo 40 seriessuits 1 ¼” to 2” & largerscrewed bodies0.4 1 8 16 1250.45 8 9 18 1380.5 2 10 20 1500.55 2.3 11 23 1620.63 2.5 12 25 1800.7 2.8 13 28 1990.8 3.2 15 32 2160.9 4 16 36 2331 4.5 18 411.1 5 20 451.2 5.5 23 491.3 6.3 25 541.5 7 28 591.6 8 32 661.8 9 36 732 10 41 822.3 11 45 912.5 12 49 1022.8 13 1143.2 153.5 164 184.5 205 235.56.3789Smaller <strong>flow</strong>s can be fitted to larger bodies.Kwyflo <strong>flow</strong> rate options are limited to<strong>flow</strong>s listed in bold type. It is recommendedthat a strainer be inserted in front of “lowFlow” <strong>valves</strong> where water may contain solidparticles over 1mm in diameter.Pressure dropType Accuracy Operating range ApplicationPrecision ±10% 140-1000kPa Where precision is requiredwithin 140-1000kPa rangeKwyflo ±10% 175-1000kPa Where quiet operatedis required e.g. Homes,hospitals, etcSpotcheck ±20% 140-1000kPa For economyLow pressure ±20% 40-1000kPa Where low "head-loss"is requiredHigh pressure ±20% 250-1500kPa Where pressures over1000kPa are encountedThe illustrations in this catalogue are subject to modifications without notice.premierP.O. Box 11735, Randhart, South Africa, 1457sales@premier<strong>valves</strong>.co.za<strong>valves</strong> (Pty) LtdT +2711-908-3760 F +2711-908-1268www.premier<strong>valves</strong>.co.za


<strong>Baker</strong> Maric Flow Control <strong>Valves</strong>5Applications• Showers• Kitchens• Water softeners & Filters• Hand basins / washing troughs• Gland water <strong>control</strong>• Drinking fountains• multi-storey buildings• Safety washing equipment• Fertilizer / irrigation dosing equipment• Sprinklers / irrigation• Water treatment• Ultraviolet water sterilization• Evaporative air conditioners• Water heaters and collers• Dust suppression• Fire-fighting foam mixture <strong>control</strong>• Fire-fighting <strong>flow</strong> <strong>control</strong>• Water authority / supply metering• Mining• Distilleries• Pump / bore protectionHEADLOSS OR PRESSURE DROP (P.D.) ACROSS VALVEQuestion: What will be the head loss across the<strong>Baker</strong> Valve?Answer: At least 140 kPa, or between 140 and 1 000kPa if the system is designed and operating correctly.This is because the function of our “PRECISION” rangeof <strong>valves</strong> is to <strong>control</strong> the <strong>flow</strong> when P.D. across the valveis within this range. Therefore, to achieve full rated <strong>flow</strong>,(accurate to within +/- 10%), the installation must providefor inlet to be at least 140 kPa above outlet pressure.To Calculate Headloss:Assume valve is <strong>control</strong>ling <strong>flow</strong> as required. Determinewhat pressure will be at the inlet, and what pressurewill be at the outlet. The P.D. will then simply be thedifference between inlet and outlet above. Should thiswork out to be less than 140 or greater than 1 000 kPa,then this PRECISION valve will not provide full <strong>flow</strong> andthe installation will either require altering, or the useof Low Pressure <strong>Valves</strong> (40 - 200 kPa) or High Pressure<strong>Valves</strong> (250 - 1 500kPa).Performance GraphTYPICAL OF ALL PRECISION VALVES IRRESPECTIVE OF BODY SIZE OR FLOWRATE120%110%Rated Flow100%Expressedas % of fullrated <strong>flow</strong>90%80%70%60%kPa 100 200 300 400 500 600 700 800 900 1000 1100The illustrations in this catalogue are subject to modifications without notice.premierP.O. Box 11735, Randhart, South Africa, 1457sales@premier<strong>valves</strong>.co.za<strong>valves</strong> (Pty) LtdT +2711-908-3760 F +2711-908-1268www.premier<strong>valves</strong>.co.za


premier <strong>valves</strong> (Pty) LtdA - P.O. Box 11735, Randhart, South Africa, 1457 W - www.premier<strong>valves</strong>.co.zaT +2711-908-3760 F +2711-908-1268 E - sales@premier<strong>valves</strong>.co.zaAgent’s stamp