12.07.2015 Views

06-30.1 E EcoLine 4000.cdr

06-30.1 E EcoLine 4000.cdr

06-30.1 E EcoLine 4000.cdr

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

GASANALYSIS<strong>EcoLine</strong> 4000palm-top flue gas analyserOrdering CodStandard package includes:<strong>EcoLine</strong> 4000 base unit with one electrochemical sensor, fluegas sample probe with water trap and line filter, battery charger,Infrared port, Instruction manual, Eurotron calibration certificate.cat. 7828 - A - B - CC - D - E - F - G - HTable A Sensor n.11 O 2 (0-25%)BB610046 300mm long gas +draft sampling probe(double hose)BB880028BB880033ABS rigid carrying caseAluminium carrying caseTable B Sensor n.20 none2 CO (0-10000 ppmH 2 compensated)2X CO (0-20000 ppm)Table C Sensor n.3 and n.40 none4 NO & NOx (0-5000 ppm)5 NO 2 (0-1000 ppm)6 SO 2 (0-5000 ppm)Table D Gas sampling probe0 none1 180 mm flue gas or draft (single hose) probe2 300 mm flue gas or draft (single hose) probe3 180 mm flue gas + draft (double hose) probe4 300 mm flue gas + draft (double hose) probe5 750 mm flue gas + draft (double hose) probe withremovable shaft6 180mm 90° flue gas or draft (single hose) probeTable E Options0 none1 Internal impact printer2 Pressure/Draft sensor3 Gas network leak test mode (pressure decay)4 Graphic display capabilityEE300086Differential pressureprobe and burnerpressure kitTable F Line charger1 115 Vac with USA plug2 230 Vac with Schuko plug3 230 Vac with UK plug4 230 Vac with European plug5 100 Vac with USA/Japan plugBB830010 Gas snifferBB830008 T+RH% snifferBB8300<strong>06</strong>BB830009 CO ambient snifferF78280002 meters long remoteair sensor with coneHand shoot pumpfor smoke indexmeasurementsTable G Accessory0 None1 GasConfig and DBGas 2000 PC software + IR/RS232converting module2 Shoulder strap with magnetic plate3 PEHD case (instrument + gas probe + accessories)4 Aluminum case (instrument + gas probe + accessories)5 Remote air sensor with 2m cable length6 Remote air sensor with 5m cable length7 Burner pressure probe8 Ambient CO probe9 Sniffer (natural gas checker)B Hand shoot pump for smoke index measurementC Temperature and relative humidity probeTable H Report of Calibration1 Eurotron reportSpecifications may change without notice.eurotronhttp://www.eurotron.co.krEUROTRON(korea)Ltd-Seil int'l3F,Yeol lim B/D,544-1,Kuro-5 dong,Kuro-Ku, Seoul, KoreaTel : +82-02- 837-6974Fax: +82-02- 859-2059Distributed by:

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!