Eurotron InstrumentsISO 9001QualityrnG adet<strong>UniGas</strong> <strong>1000+</strong>eurotron"Excellence in measurements"Professional CombustionFlue Gas AnalyserProviding the Latest Technological Analyser for HeatingService Engineers, Gas Installers & PlumbersFLUE GASANALYSER8 INSTRUMENTS IN 1:EN 5 0 379 -2(O an C12Combustion FlueGas AnalyserDraft & DifferentialPressure Meter2 d O-H 2)Com pliant32 Channel DifferentialThermometer4 Ambient CO Monitor(Room Test)5 Gas NetworkLeak / Tightness Tester6 Gas Leak Detector7 Ionization Flame Tester8 NO/NO EmissionsXO 2CO 2CONO xBullettin 06-10.5 E - ed. 11.2006Built-in Impact Printer (NotThermal !)Built-in Gas SnifferRechargeable BatteryEasy to Use, with Large MultilineDisplay & Rotary KeysStores up to 250 CompleteAnalysis with Customer Name &AddressWindows Software & USB CableUpgradable Using Flash MemoryMagneticRubber HolsterIncluded !EfficiencyExcess AirDifferentialPressureTairTgasCO/CO 2RatioAmbient COMonitorGas LeakDetectorDesigned to meet BS7927, BS7967, TUV, ISO, Gastec QA Criteria, GOST, Qualigaz, and UNI 10389All descriptions are related to a fully optioned instrument. See last page for the different configurations.5


FLUE GASANALYSERMultifunction Unit for theComplete Maintenanceof Your BoilerOne InstrumentMulti Functions and Multi ReportsYour company namePhone number hereFax number here<strong>UniGas</strong> 1000 PLUSSerial Number 102597Date: 29/09/2006Time: 14:15Fuel: Natural GasO2: 10.3 %CO2: 6.0 %Exc. air λ: 1.86Flue : 138.9 °CInlet : 42.2 °CTemp. nett : 96.7 °CEff. Net : 92.3 %Loss. Net : 7.7 %Eff. Gross : 83.7 %Loss. Gros : 16.3 %CO : 0 ppmDraught : ------CO/CO2: 0Rif. %O2: 3.0 %CO : 0 ppmEasy replaceable gas sensors<strong>UniGas</strong> <strong>1000+</strong> uses long lifelow maintenance sensors for O 2and CO. Alarm levels withaudible buzzer on gasesmeasurement.Multi Fuel selection<strong>UniGas</strong> <strong>1000+</strong> provides up to10 fuels for calculatingcombustion values. Most usedfuels for your country are preloadedfrom factory. Othersfuels can be added usingGasConfig PC software.Gas sampling probeFlue gas sampling probes, withdifferent lengths and shapes,are available to match eachspecific requirement. Thesampling probe is connected tothe instrument with a single ordual hose through a water trapand a suspended particle filter.Gas pipework leak testTo check gas pipework for thepresence of leaks using apressure decay program andthe internal pressure sensor.The tightness test procedureincludes dual report (let by).IGE / UP / 1B compliant.Gas leak snifferThe instrument can operate intwo ways:An external optional probe isavailable to locate the positionof a gas leak. This probe has aflexible stainless steel shaft toreach difficult locations.An internal optional sensor canbe installed inside the analyserto locate the position of a gasleak into the domestic pipenetwork. The internal pumpdraws the air from ambient andmakes the instrument moresensitive for micro-leaks.Your company namePhone number hereFax number here<strong>UniGas</strong> 1000 PLUSSerial Number 102597Date: 29/09/2006Time: 14:44Let by TestCompliant to IGE/UP/1BStart P1: 1.85 mbarFinish P2: 0.04 mbarDrop : -1.81 mbarDuration : 60 secsSmoke indexSmoke index measurement isperformed by using the optionalexternal hand pump. Theresults can be stored in theinternal memory and printed onthe report.Pressure/Draft & TightnessTestDifferential pressure input toverify: draft, gas network leakwith pressure decayprogramme, gas flow pressure,pressure in combustionchamber, ∆P on filters and fan,pressure switches calibration.Your company namePhone number hereFax number here<strong>UniGas</strong> 1000 PLUSSerial Number 102597Date: 29/09/2006Time: 14:41Draught:119.1 hPaYour company namePhone number hereFax number here<strong>UniGas</strong> 1000 PLUSSerial Number 102597Date: 29/09/2006Time: 14:33Differential TemperatureFlow T1 : 61.9 °CReturn T2 : 87.5 °CDiff. Temp : 25.6 °CDifferential ThermometerThe dual input temperatureprobes has to be used in theflue gas analysis for flue and airinlet measurements. The<strong>UniGas</strong> <strong>1000+</strong> can be usedalso as a two channelthermometer to measure air,liquid and surface (pipe)temperatures.Ideal for Benchmark Test.Ambient CO safetymonitoring Room Test(BS7967)A procedure can be selected tomonitor the CO in ambient airusing the internal sensors. Aninternal program allows the COmax measurement inatmospheric boiler room testwith 15 values logging.An external optional probe isalso available for continuoussurveillance of the ambient andoperator safety. Both acousticand visual alarm are available.Your company namePhone number hereFax number here<strong>UniGas</strong> 1000 PLUSSerial Number 102597Date: 02/10/2006Time: 14:41CO room testCompliant to BS 7967Time CO01 : 14 ppm02 : 14 ppm03 : 14 ppm04 : 14 ppm05 : 14 ppm06 : 14 ppm07 : 15 ppm08 : 17 ppm09 : 17 ppm10 : 19 ppm11 : 20 ppm12 : 20 ppm13 : 20 ppm14 : 20 ppm15 : 20 ppmCO MAX : 20 ppm6


FLUE GASANALYSER<strong>UniGas</strong> <strong>1000+</strong>The Most Powerful andComplete Gas AnalyserRotary KeysTechnical SpecificationsType: palm-top combustion gas analyser.Calibration: automatic calibration procedure at instrument switch-On.Self-diagnosis: Sensors efficiency test with display diagnostic messages.Fuel types: Up to 10 selectable from keyboard (most common preprogrammed).Power supply: High capacity Ni-MH rechargeable battery pack / external battery charger.Charging time: 8h at 90% with instrument Off.Battery life: 6 hours (typical) continuous use (without printing and backlit).Memory: up to 250 full analysis data structured by boilers (Tags).Printer: Internal impact type 24 columns with 58 mm paper roll.Printer power supply: from the analyser battery pack.Print autonomy: up to 40 reports with full battery (typical).Printed report header: 4 programmable lines.Display: 40x58 mm alpha-numeric LCD with backlit device.Serial communication: RS232 interface. USB cable optional.Infrared port: compatible with HP82240B cordless printer.Operating temperature: from -5°C to +45°C - from 10 to 90% RHStorage temperature: from -20 to +50°C (3 months maximum at temperatures exceedingthe operational limits).Dimensions and Weight: 115x90x330 mm - 1.1 kg with battery and printerWarranty: 2 years - sensors, connectors, battery, printer and pump included.DBGas 2004PC Software<strong>UniGas</strong> <strong>1000+</strong> can store 250readings structured by boilers andcustomers. Using the optionalTMDBGas2004 Windows softwarepackage, you can organize andmanage your inspection andmaintenance activity. Select yourcustomer and boiler details from PC anddownload to your analyser.DBGas 2004 software packageTMincludes GasConfig Windowssoftware. Using the Configurationsoftware you can change theconfiguration of the analyser.BB530211USB CablePa Probe (BB830025)Parameter Sensor Range Resolution AccuracyO 2Electrochemical 0 - 25% 0.1% ±0.1% volCO Electrochemical 0 - 20000 ppm 1 ppm ±1 ppm


FLUE GASANALYSER<strong>UniGas</strong> <strong>1000+</strong>Modular Design GivingTotal FlexibilityAccessoriesOrdering CodeBB880028ABS rigid carrying caseBB880033Aluminium carrying caseBB880043Compact rigid carrying case withshoulder stap. <strong>UniGas</strong> <strong>1000+</strong>, probes,and accessories need 1/3 of theclassic carrying case space.BB610051180mm (TGD - Temperature, Gas,Draft) sampling probeBB610046300mm (TGD - Temperature, Gas,Draft) sampling probeEE300086Differential pressure probe andburner hose kitF7828000Manual pump for smoke indexmeasurementsBB830006Pt100 remote air sensor with coneBB290031DC Auto AdapterBB830009AmbientCO probecat. 7882 - A - BB - C - D - E - F - GThe standard package includes:Unigas <strong>1000+</strong> base unit with one electrochemical sensor, batterycharger, differential pressure sensor, infrared port for HP thermalprinter, instruction manual, magnetic rubber holster, RS232 cable,Eurotron calibration certificateTable A Sensor n.10 none1 O2(0-25%)Table B Sensor n.2 & n.30 none2H CO (0-10000 ppm)H2compensated4 NO/NOx (0-4000/5000 ppm)Table C Sample probes (including water trap and line filter)0 none1 180mm flue gas probe + draft (dual hose) BB6100512 300mm flue gas probe + draft (dual hose) BB6100463 90mm 90° flue gas or draft (single hose) probe BB6100434 160mm multipoint flue gas (single hose) probe foratmospheric boilers BB610070Table D Options1 Sample probe 750,1000,1500 mm (1200°C )2 Internal sensor for gas leak detector3 External probe for gas leak detector4 External probe for CO operator safety6 Software GasConfig + DBGas2004 + USB cable7 External probe for boiler ionization current8 Remote combustion air temperature sensor with 2m cableand positionning cone9 Differential pressure connection kit (dual hose)P Built-in impact printerTable E Mains adapter / charger1 115V ±10% 50/60Hz - USA plug2 230V ±10% 50/60Hz - Schuko plug3 230V ±10% 50/60Hz - UK plug4 230V ±10% 50/60Hz - European plug5 100V ±10% 50/60Hz - USA/Japan plugBB830010Gas sniffer probeBB830019Ionization current probeF2139000Pipe Velcro TC K-TypeF2132100130mm air TC K-TypeF2137100130mm Contact TC K-TypeF2139100Tc K-TypeClamp temperature probeF2139200Pt100Clamp temperature probeTable F Accessories0 None3 Vinyl case with shoulder strap4 ABS carrying case5 Aluminum carrying case6 Manual pump for smoke index measurement with filtersand comparison table7 DC Auto battery chargerTable G Calibration Certificate1 Eurotron reportConsumable partsEE650011 Filter paper set for smoke indexmeasurements (40 pcs)EE860004 Smoke index comparison tableEE340006 Paper rollEE490002 Printer ribbon cartridgeEE650074 Spare line filter cartridgeNON-CONTRACT DOCUMENT - SUBJECT TO CHANGE8