12.07.2015 Views

Zero-Point-SyStemS - STOCKFER

Zero-Point-SyStemS - STOCKFER

Zero-Point-SyStemS - STOCKFER

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Pneumatic pressure boosterNo. 6370ZVL-005Pneumatic pressure boosterOrderno.Input pressure (bar)[bar]Output pressure (bar)[bar]ConnectionWeight[Kg]427088 2,5-8 4,5-10 G1/4 1,5Design:Pressure intensifier with possibility to adjust the pneumatic output pressure, incl. manometerconstruction kit, sound absorbers and flange mounting.Application:For strengthening the operating pressure with pneumatic clamping modules and compensation forpressure fluctuations in the supply line.Note:The pressure intensifier can be mounted in every installation position. For operation, filtered (40μm),unlubricated compressed air as per ISO 8573-1 is required. The pressure intensifier is suitable forambient temperatures of +5 – +60 °C.No. 6370ZVL-004Pneumatic pressure booster setOrderno.Input pressure (bar)[bar]Output pressure (bar)[bar]ConnectionWeight[Kg]421396 2,5-8 4,5-10 G1/4 2,5Design:Pressure intensifier group with possibility to adjust the pneumatic output pressure, incl. manometerconstruction kit, sound absorbers, flange mounting, pressure control valve, manual direction valve,coupling plug, connections and plastic tube.Application:For strengthening the operating pressure with pneumatic clamping modules and compensation forpressure fluctuations in the supply line.Note:The pressure intensifier can be mounted in every installation position. For operation, filtered (40μm),unlubricated compressed air as per ISO 8573-1 is required. The pressure intensifier sub-assembly issuitable for ambient temperatures of +5 – +60 °C.No. 6370ZVL-006Pneumatic pressure booster cabinetOrderno.Input pressure (bar)[bar]Output pressure (bar)[bar]B x H x T Connection Weight[Kg]427104 2,5-8 4,5-10 200 x 300 x 155 G1/4 7,0Design:Connection-ready pressure-intensifier cabinet with possibility to adjust the pneumatic outputpressure.Application:For strengthening the operating pressure with pneumatic clamping modules and compensation forpressure fluctuations in the supply line.Note:The connection-ready pressure intensifier cabinet is shipped with wall-mounting bracket and can bemounted in every installation position. For operation, filtered (40μm), unlubricated compressed air asper ISO 8573-1 is required. The pressure cabinet is suitable for ambient temperatures of 0 – +40 °C.Subject to technical alterations.ANDREAS MAIER FELLBACH ∙ www.amf.de <strong>Zero</strong>-<strong>Point</strong>-Systems 85

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!