12.07.2015 Views

1 Electronic Flow Meter FC01 - FlowVision GmbH

1 Electronic Flow Meter FC01 - FlowVision GmbH

1 Electronic Flow Meter FC01 - FlowVision GmbH

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SW20ø18M16x0.75round connector<strong>FC01</strong> - Monitoring head CSF-01DescriptionMonitoring head CSFExtended calorimetric monitoring head for <strong>Flow</strong> <strong>Meter</strong> <strong>FC01</strong>, suitablefor use in air-conditioning systems (variable immersion depth).Caution: - Calibration to flow velocity, therefore do not use with<strong>FC01</strong>-CA.- Fix with locking set 01 (see accessories).Features● Medium temperature range: -40 °C...+130 °C● Material: stainless steel 1.4571/AISI 316 Ti1CSF-01variable immersion depthOrdering informationTechnical dataTypeCSFExtended monitoring head with calorimetric sensorsMonitoring head design01 Monitoring head with variable immersion depthMediumA airW waterMaterial of areas exposed to mediumM1 stainless steel 1.4571/AISI 316 TiProcess connection00 without flange; see accessoires for cable gland**)Length of shank/threadL43 188 mm (standard with process connection 00)other lengths upon requestElectrical connectionE10 round connector with tinned contacts(plug and cable to separate order)CertificationT0 without certificate standard *)Specification of mediumxxxCSF - 01 A M1 00 L43 E10 T0 - ... ordering example*) for detailed information please see section 0.**) see next page.DimensionsType of headNominal shank dia.Length of shankLength of sensorSuitable forTemperature range*)(of medium)Temperature driftof sensorpush-in18 mm188 mm (standard)14 mmair(please enquire for other gases)-40...+130 °C / stainless steel± < 0.05 %/°K/measuring range(in the range between +20 °C and +80 °C)Measuring ranges: air: 0...20 m/s (atmospheric pressure)water: 0...3 m/sPressure resistance (1) 100 bar / 1470 PSIof sensor DIN 2401Pressure resistance depending on threaded installation bushof installation2 bar/16 bar (29.4 PSI/235.2 PSI), see next pageDegree of protection connector( 2) : IP67Materialstainless steel 1.457/AISI 316 TiCable to LifYCY 4x2x0.2 mm 2 (AWG 24)electronic unit(1) Admissible operating pressure DIN 2401, measured at max. temperature(= max. medium temperature)(2) with mating connector*) max. +85 °C in the connector areaø2214.866 .551L9.5.374.709.78714.551TypeLmm inchCSF-…L43… 188 7.40CSF-…L30… 300 11.81CSF-…L40… 400 15.75monitoring head should bealigned in direction of flow(see arrow)This is a metric design and millimeter dimensions take precedence ( mm )inchIssue A(010108)www.e-t-a.com 1 - 57

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!