12.07.2015 Views

4 Channel Gas Monitor Specification - A1 Cbiss

4 Channel Gas Monitor Specification - A1 Cbiss

4 Channel Gas Monitor Specification - A1 Cbiss

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

4 <strong>Channel</strong> <strong>Gas</strong> <strong>Monitor</strong>Fixed <strong>Gas</strong> Detection<strong>Gas</strong> <strong>Monitor</strong>sThe 4 <strong>Channel</strong> <strong>Gas</strong> <strong>Monitor</strong> is an innovative, cost effective, wall mounted unit.It is designed to operate in conjunction with the T100 toxic gas detector and thehighly successful CGS500 combustible gas sensor to monitor a range of toxicgases, combustible gases and oxygen in a wide range of applications.The 4 <strong>Channel</strong> <strong>Gas</strong> is also compatible with a wide range of third party 4-20mAtransmitters including temperature probes.The gas concentration is indicated on a 4-digit, 7-segment display while another2-character alphanumeric display indicates instrument status. A third displayindicates the active channel.Features:• Individual voltage free relay contact• Advanced digital readout• User programmable• Low power consumption• Built-in battery backup circuit• Alarm inhibit during calibration• 4-20mA analogue output• Extensive fault detection firmwareSimple to use and microprocessor controlled, the 4 <strong>Channel</strong> <strong>Gas</strong> <strong>Monitor</strong> is menuassisted and fully user programmable for alarm setpoints, relay options, range,sensor type, gas type and many other parameters in a user friendly manneroffering unique flexibility and control over the system.Careful product design and rigorous product testing combined with a stringentISO9002 quality assurance program ensure ultimate reliability.The 4 <strong>Channel</strong> <strong>Gas</strong> <strong>Monitor</strong> offers a robust, easy to use, cost effective approach toproviding an effective gas monitoring system where safety matters.<strong>Specification</strong>Mechanical <strong>Specification</strong>s:• Dimensions: H x W x D: 230mm x 300mm x 110mm• Weight: 3.5Kg (including optional 1.2AH battery, if fitted)• Mounting holes: 4 holes, Ø4.2mm, spaced at 200mm(vert) 288mm (horz)Environmental <strong>Specification</strong>s:• Operating temperature: -18˚C to +66˚C• Storage temperature: -40˚C to +66˚C• Humidity range: 10%RH to 90%RH (Non-condensing)Electrical <strong>Specification</strong>s:• Supply voltage: 230Vac (115Vac optional)• Power consumption: 6W• Relay contacts: SPDT, 250V, 3A each for <strong>A1</strong>, A2, CommonA3 & FAULT (10 relays)• Analogue outputs: 4-20mA into maximum 250 Ω foreach channel• Max. units on RS485 loop: 25 controllers (100 channels)• Unit interrogation time: 40mS• Battery operation time: 1.2AH battery: typically 2 hourswith all 4 detectors fitted• Battery voltage: 12V• Battery type: Sealed lead-acid• Stabilisation time: User selectable between 1 and 255seconds• Resolution: 1%• Accuracy: 5%• Full scale range: 1.00 to 5000 (user selectable)• User variable storage: Non-volatile RAM (EEPROM)• Enclosure material: Two-piece, hinged, ABS orpolycarbonate with neoprene gasket• Electromagnetic Conformance (EMC): Complies withEN50081 and EN50082026Certificate Number 996QM8001t: +44(0)151 666 8300 f: +44(0)151 666 8329 e: sales@a1-cbiss.com www.a1-cbiss.com


Fixed <strong>Gas</strong> Detection<strong>Gas</strong> <strong>Monitor</strong>sMultichannel <strong>Gas</strong> <strong>Monitor</strong>The Monicon Multichannel <strong>Gas</strong> <strong>Monitor</strong> is an innovative, cost effective, rackmounted system. for use with the T100 or similar thermocatalytic sensor.The Multichannel <strong>Gas</strong> <strong>Monitor</strong> is also compatible with a wide range of third partysensors and 4-20mA transmitters including temperature probes.Simple to use and microprocessor controlled, the Multichannel <strong>Gas</strong> <strong>Monitor</strong> ismenu assisted and fully user programmable for alarm setpoints, relay options,range, sensor type, gas type and many other parameters in a user friendlymanner offering unique flexibility and control over the system.Careful product design and rigorous product testing combined with a stringentISO9002 quality assurance program at Monicon’s state-of-the-art manufacturingfacility ensure ultimate reliability.The Monicon Multichannel <strong>Gas</strong> <strong>Monitor</strong> offers a robust, easy to use, cost effectiveapproach to providing an effective gasFeatures:• Fully independent operation perchannel• Voltage free relay contacts (SPDT)• Open collector outputs• Advanced digital readout• Fully user-programmable• Low power consumption• 4-20mA Analogue Output• Extensive fault detection circuitry• Up to 16 channels per “Eurorack”<strong>Specification</strong>Mechanical <strong>Specification</strong>s• Height: 112mm (4U version: 178mm)• Width: 25mm• Length: 222mm (4U version: 200mm)• Weight: 300g (4U version: 330g)• No. of channels per “Eurorack”: Up to 16Environmental <strong>Specification</strong>s• Operating temperature: -18˚C to +66˚C• Storage temperature: -40˚C to +66˚C• Humidity range: 10%RH to 90%RH (Non-condensing)Electrical <strong>Specification</strong>s• Supply voltage: 20-35Vdc• Supply current (per channel): Normal 80mA, Alarm 120mA @24Vdc• Relay contacts: SPDT, 230Vac, 3A each for <strong>A1</strong>, A2 and A3 oneach control card• Analogue output: 4-20mA into maximum 500 Ohms• Max. units on RS485 loop: 100• Combustible gas sensor type: Monicon CGS500 orcompatible third-party thermocatalytic sensor• Toxic gas sensor type: Monicon T100, IR100 or compatiblethird-party 4-20mA transmitter• Stabilisation time: C25005 is variable 1-250 seconds; C55005is fixed at 30 seconds• Option setting: Digital setting (all options fitted as standardand user selectable)• Alarm setting: Digital setting (fully adjustable between 10%and 90% of full scale)• Alarm types: Energised/de-energised. Enrichment/deficiency. User selectable• Resolution: 1%• Accuracy: 5%• Full scale range: C25005 is user programmable; C55005is fixed at 100% LEL026Certificate Number 996QM8001t: +44(0)151 666 8300 f: +44(0)151 666 8329 e: sales@a1-cbiss.com www.a1-cbiss.com


IR80 CO2 <strong>Gas</strong> <strong>Monitor</strong>Fixed <strong>Gas</strong> Detection<strong>Gas</strong> <strong>Monitor</strong>sThe Monicon IR80 CO2 <strong>Gas</strong> <strong>Monitor</strong>ing Unit is a high quality, self contained,NDIR (Non Dispersive Infra Red) gas sensor that offers a host of sophisticatedfeatures to provide fast, reliable warnings against exposure to dangerousconcentrations of carbon dioxide.The IR80 will operate as a standalone instrument or in conjunction with acontroller or a computer. It is housed in an attractive, compact enclosure andmay be configured or calibrated by one person.The gas concentration is indicated on a rugged 8-character alphanumericdisplay which also indicates instrument status.The IR80 is fully user programmable and no physical adjustments are necessaryduring calibration as the on-board computer assists the calibration procedure.All user variables are stored in non-volatile memory (EEPROM) andretained indefinitely even during total power failure.Features• Microprocessor based• 4-20mA Analogue Output• Voltage free relay contacts• “One person calibration”• Dual detectors• Temperature compensation• Standalone operationApplications• Breweries• Landfill sites• Food processing• Mushroom farming• Greenhouses• Cellars• Chemical processing<strong>Specification</strong>• Supply voltage: Nominal 24Vdc• Power consumption: 2W nominal, 2.3W maximum• Analogue output: 4-20mA• Analogue output load: 100 Ohms typical, 500 Ohmsmax• Operating temp: -20˚C to +50˚C• Storage temperature: -40˚C to +66˚C• Humidity range: 10%RH to 90%RH (Non-condensing)• Full-Scale range: 0 - 5% CO2• Response time :(T90) Typically


Fixed <strong>Gas</strong> Detection<strong>Gas</strong> SensorsS500L-IR NDIR <strong>Gas</strong> SensorThe Monicon S500L-IR is a high quality, self contained, NDIR (Non DispersiveInfra Red) gas sensor that offers a host of sophisticated features to provide fast,reliable warnings against explosive concentrations of combustible gases.The S500L-IR will operate as a standalone instrument or in conjunction with acontroller or a computer. It is housed in an attractive, compact diameterenclosure and may be configured or calibrated by one person, withoutdeclassifying the hazardous area.The gas concentration is indicated on a rugged 4-character alphanumeric displaywhich also indicates instrument status.Features:• Dual Beam NDIR technology• Microprocessor based• 4-20mA Analogue Output• RS485 digital interface• Dual detectors• Temperature compensationThe S500L-IR is fully user programmable and no physical adjustments arenecessary during calibration as the on-board computer assists the calibrationprocedure. Because the unit uses infrared energy rather than catalysts, the sensoris unaffected by the catalytic poisons that have an adverse affect on traditional“pellistor” based sensors.All user variables are stored in non-volatile memory (EEPROM) and retainedindefinitely even during total power failure.<strong>Specification</strong>• Supply voltage: Nominal 24Vdc (operates from 20Vdc to35Vdc)• Power consumption: 2W nominal, 2.3W maximum• Analogue output: 4-20mA current source referenced to 0V• Analogue output load: 500 Ohms maximum• Operating temperature: -20˚C to +50˚C• Storage temperature: -40˚C to +66˚C• Humidity range: 10%RH to 90%RH (Non-condensing)• Preconditioning Requirements Operational: 30 seconds,• <strong>Specification</strong>: 15 minutes• Full-Scale range: 0 - 100% LEL (Lower Explosive Limit)• Response time: (T90) Typically


Fixed <strong>Gas</strong> Detection<strong>Gas</strong> SensorsT100The T100 is a 4-20mA, 2-wire transmitter to measure a wide range ofgases and is housed in a rugged, compact metallic enclosure.Designed to be maintenance free and inherently stable.Features:• Built-in ZERO & SPAN controls• One person calibration• SMD electronic circuitry• Enhanced RFI and EMI resistance• Cost effective with high performance• Works with most 4-20mA controllers• Certified ATEX Eex ia IIC T4<strong>Specification</strong>• Supply voltage: Nominal 24Vdc (operates from12Vdc to 30Vdc)• Supply current: Normal: 4mA, full-scale 20mA• Ec-cell operating life in air at S.T.P.: Typically 2 years• Preconditioning Requirements: 1 Hour (24 hours forHCl, C2H4O, & NO)• Storage life at 0 to 20°C: 6 months• Operating temperature range: -20°C to +40°C• Operating pressure range: Ambient ± 10%• Operating RH range: 15% to 90% non-condensing• ATEX certification: II 2 G EEx ia IIC T4 (Certificate No.SIRA03ATEX2405)• Size: W: 75mm, D: 58mm, H: 80mm (excludingsensor)• Weight: 400g• Electromagnetic Conformance (EMC): Complieswith EN50081 and EN50082• Enclosure material: Durable aluminium ALSi12,magnesium content


Fixed <strong>Gas</strong> Detection<strong>Gas</strong> SensorsCGS500The CGS500 combustible gas sensor has been designed tomeasure concentrations of combustible gases in the range0-100% LEL. The CGS500 is available as a sensor only orfitted in an EEx e certified junction box.Features• Temperature compensated• Low drift• Improved poison resistance• Long life• Fast response time• Rugged stainless steel sensor• Detects combustible gases and solvents• Certified ATEX II 2 G EEx d IIC T6<strong>Specification</strong>• Operating voltage: 2.05Vdc ± 0.05Vdc• Operating current: 300mA (for standard andpoison resistant versions)• Detection range: 0-100% LEL• T90 response time: Typically < 15 seconds• Stabilisation time: 1 minute• Preconditioning time: 1 hour• Operating temperature range: -20°C to +40°C• Mounting thread: M25 X 1.5mm• Accessory thread: M42 X 1.5mm• Weight Sensor: 400g Standard junction box: 300g• Size of junction box (excluding sensor) W: 75mm,D: 58mm, H: 80mm• Electromagnetic Conformance (EMC): Complieswith EN50081 and EN50082• ATEX certification: II 2 G EExd IIC T6 (CertificateNo.BAS00ATEX2246X)026Certificate Number 996QM8001t: +44(0)151 666 8300 f: +44(0)151 666 8329 e: sales@a1-cbiss.com www.a1-cbiss.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!