13.07.2015 Views

CEMS Brochure Double Pages.pdf - A1 Cbiss

CEMS Brochure Double Pages.pdf - A1 Cbiss

CEMS Brochure Double Pages.pdf - A1 Cbiss

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Environnement SA MIR-FTFourier Transform Infra-RedEnvironnement SA MIR-9000(Plus CLD Option)Multi-Gas Infrared GFC AnalyserDatasheetDatasheetThe MIR-FT is rack mounted in air conditioned enclosures.Complete systems would normally comprise of:• Sample extraction and conditioning probe (with integratedtemperature, pressure and flow measurement)• Heated sample lines• Automatic calibration units• Instrument air drying system• CDAS Data Acquisition SoftwareInstalled across the majority of the UK’s municipal wasteincinerators, the MIR-FT Utilises Fourier Transform Infra-Red(FT-IR) to offer multiple gas measurements simultaneously,including NO, NO 2, SO 2, NH 3, HCl and CO.With the emissions limits tightening and new gases beingintroduced, this instrument allows future gas upgrades,providing the solution for today and what may happentomorrow. Designed to operate under legislation such as2000/76/EC (WID) and 2001/80/EC (LCPD), The MIR-FToffers maximum availability and complete compliance withQAL 1 of EN14181 & EN15267-3.Features:• Designed for measurements in wet and corrosive samplegases• Future upgrades possible• Excellent calibration stability• Automatic spectral interference corrections• Fast and simultaneous measurements for multiple gases• Reproducible and accurate• Windows based PC driven software with on-board dataacquisition• Capable of automatic QAL 3 checks when used inconjuction with IVIS unit• MCERTS CertifiedComplete systems would normally comprise of:• Sample extraction and conditioning probe (with integratedtemperature, pressure and flow measurement)• Cold sample lines• Automatic calibration units• Instrument air drying system• CDAS Data Acquisition SoftwareWith over 1500 installations world wide, the MIR-9000 is a provenContinuous Emissions Monitoring system across a wide range ofindustries. All measurements are supplied dry as the sample isconditioned at the extraction point via the SEC drying system beforebeing transported down a cool polytube line.The MIR-9000-CLD option utilises the Standard Reference Method(SRM) for the monitoring of NO N 2O NO 2NO xCO CO 2SO 2andO 2. The MIR-9000-CLD analyser is a free standing monitoringsystem that incorporates three monitoring technologies, these areChemiluminescence for low level NO xmeasurement, Infra-Red GasFilter Correlation for CO, CO 2etc and finally Paramagnetic for O 2.Designed to operate under legislation such as 2000/76/EC (WID)and 2001/80/EC (LCPD), The MIR-9000 offers maximum availabilityand complete compliance with QAL 1 of EN14181 & EN15267-3.Features:• Measures from 1 - 10 gases simultaneously• Built-in data logger for 7 additional parameters (flow, pressure,temperature or any other analogue input)• Real time graphic display• Interactive menu-driven software allowing ease of operation• Unheated sample line utilising permapure drying technology• Readings measured and expressed on a dry basis• On-board oxygen correction for environmental reporting• Optional stack pressure, temperature and flow measurementsavailable• MCERTS CertifiedSpecificationSpecificationApplications:• Municipal, Industrial & HospitalWaste Incinerators• Power & Combustion• Biomass• Cement Kilns• Pulp & Paper• DeNOx (SNCR, SCR)Specification:Zero drift: ± 1% full scale/30 daysSpan drift: ± 1% full scale/30 daysRepeatability: ± 2% full scaleLower detectable limit: 2% full scaleResponse time:


PCME QAL181 & QAL991Particulate Monitoring SystemsSyngas Monitoring SystemDatasheetDatasheetWith online calibration capability, the QAL181 & QAL991minimises drift but also offers the QAL3 facility when usedwith CDAS Elite Data Acquisition Software.The PCME QAL181 utilises Proscatter to measure thescattered forward light from a laser source. The QAL991utilises PCME’s unique AC Electrodynamic technology, anadvanced Triboelectric method.The QAL181 & QAL991 are ideal where high accuracy andstability are required or when bag filters are not installed,designed to operate under legislation such as 2000/76/EC(WID) and 2001/80/EC (LCPD), the QAL181 offers completecompliance with EN14181, EN13284-2 & EN15267-3.Features:• Automatic self-checks which record results for QAL3 tests• Capability to conduct linearity checks in accordance withEN14181• Real time graphic display with interactive menu drivensoftware• Very low limits of detection• MCERTS CertifiedSyngas Monitoring System (SMS) is designed to monitorand report the constituents of the syngas produced by thegasification process. The SMS provides live CV value,essential to determine your qualification for renewableobligation certificates (ROCS). In modern gasification wheresyngas composition is paramount for determining thecalorific value, the a1-cbiss SMS provides an accurate, costeffective solution.The SMS utilises varying degrees of high temperatureprobes ranging from stainless steel through to inconeland water cooled if required. The SMS gas is continuouslytaken, conditioned and analysed at a single sampling point.Sample preparation and conditioning is a key elementof the system, upon which substantially depends on thecorrectness of the consequent measurement, as well as thelifetime of the measurement sensors.SpecificationApplications:• Municipal, Industrial & HospitalWaste Incinerators• Thermal Oxidisers• Exhaust Gas Analysis• Laboratories and Research Centres• Process Control• Combustion MonitoringMCERTS Certification Range:TPM: 0-15mg/m 3Specification QAL991• Certification range: 0-15mg/m 3 (asstated in QAL1 approval)• Measurement capability: 0-100mg/m 3• Long term zero drift: 3m)SpecificationSpecification QAL181• Minimum detection limit of < 0.05mg/m 3 and certification range of0-15 mg/m 3 and measurement range0-200 mg/m 3• Long term zero drift:


AMESADioxins & FuransEmissions SamplerBacharachCombustion AnalysersDatasheetECA 450The AMESA is fast becoming thesystem of choice for new build energyfrom waste plants for the continuoussampling of dioxins and furans asstandard.The continuous dioxin and furansampling system makes it possible tosample trace pollutants such as dioxinsand furans.The AMESA® is MCERTS accreditedand complies with EN1948. Fullysupported by AMLEIT monitoringsoftware and MCERTS Certified CDASElite Data Aquisition Software.SpecificationMeasures:• Oxygen (O 2), Carbon Monoxide (CO), Nitric Oxide (NO),Nitrogen Dioxide (NO 2), Sulphur Dioxide (SO 2)• Combustibles, Temperature & Draft. It also calculatescombustion efficiency, excess air, carbon dioxide, NOx(Nitrogen Oxides) and pollution unitsThe ECA 450 from Bacharach is ideal for professionals toconduct accurate combustion and emissions tests whilstimproving overall combustion efficiency, reducing fuelcosts, and determining emissions compliance.The ECA 450 takes continuous samplings of furnaces,boilers and other industrial combustion equipment for upto 8 hours and generates precise, reliable combustion andenvironmental measurements and calculations. It generatesthis complex data easily — even at selected intervals- enabling plants to make more accurate equipmentadjustments and better assess pollution levels.Features and Benefits:• Large, easy-to-read fluorescent display that is visible fromwide angles• Modular design lets you add sensors as your needschange• Built-in printer and complete data downloading to a PCcapability• Stores over 1000 individual combustion and/or pressuretest records, which can later be recalled for viewing orprintingApplications:• Municipal, Hazardous & HospitalWaste Incineration• Energy From Waste (EFW)• Production Plants• Recycling Plants• Cement Kilns• Metallurgic Plants• Pulp and PaperFeatures & Benefits:• Continuous automatic samplinggiving a more accuraterepresentation of the sample• Automated datalogging recordingover a period of 6 hours up to 30days• Datalogging including: flue gasvelocity, sample gas flow volume,flue gas temperature and cartridgetemperature as half-hourly average• Simultaneous monitoring of up to4 sample streams with 1 AMESAsystem• Remote control functionality available• Reduced costs due to optimisation ofthe built-in dioxin reduction stagesMCERTS Certification Ranges:Isokinetic Sampling Velocity:• 2-20m/sa1-cbiss are pleased to announce thelaunch of the new Bacharach PCA®3,the industry’s first advanced portablecombustion analyser with a full colourgraphic display for superior visibilityand user-friendly interface and the mostsensor configuration flexibility in itsclass.The PCA®3 is the definitive combustionand emissions analyser that enablesfast and accurate measurementfor on-demand or semi-continuoussampling of light industrial, institutional,commercial and residential furnaces,boilers and appliances.Features and Benefits:• Sensors can easily be added orremoved in the field without downtime, using the B-Smart®pre-calibrated sensor options.Measures:• In addition to the included Oxygen(O 2) and Carbon Monoxide (CO)sensors, the PCA®3 can be orderedwith CO (high), Nitric Oxide (NO),Nitrogen Dioxide (NO 2) and SulphurDioxide (SO 2) sensors.PCA 3• Flue transparency9Tel: 0151 666 8300www.a1-cbiss.com10


What is CDAS?CEnvironmental CDAS Data Acquisition Reporting and Network PackagesCDAS is the market leading MCERTS accredited (parts A, B, C1 & C2) Data Acquisition package thatretrieves data from a range of instruments for <strong>CEMS</strong>, Gas Detection and Sampling applications. The CDASsoftware meets the stringent demands of WID, LCPD, EN14181, IPPC and customer specific requirements.From data logging to data processing, trending andreporting, the CDAS software suite provides theflexibility to supply a complete solution for your site.Typical communications protocols include serial,Ethernet, analogue and digital I/O. Other protocolsare supported such as Modbus, OPC andPROFIBUS, for easy interfacing to a PLC.CData Collection, Processing & VisualisationCDAS acquires data in real time. Real time data thenconverted to:• Raw Data (Instrument Value)• Calibrated Data (EN14181 QAL2 CalibrationFunction)• Corrected Data (Reference Conditions)• Adjusted Data (Reportable Values)D A SStandard CDAS Features:• Automatic Period ReportsD A SA data file for each of the conditions above is writtento the hard disk. CDAS does not delete any datathat it has recorded.• Communicates via Remote Analogue I/O• Dual Redundant Data Collection• Correction to Standard Reference Conditions• Allows application of EN14181 CalibrationFunctions• Performs Automatic EN14181 QAL3 Testing• Graphing Options• Configurable AlarmsSira MC090153/00• Searchable Alarm History ScreenCDAS allows the data to be viewed in a fullyconfigurable screen layout to support individualpreferences via preset and customisable datachannels.CDAS ReportCDAS Report is an offline package that allowsreports and graphs to be generated. CDAS Reportoffers the flexibility to configure reports to meet therequirements of the site permit and the EA.Each report can be generated at any time withoutinterrupting the data collection process. Reports aresimple to generate using the report wizard.Based on market feedback and regularcommunications with existing customers,a1-cbiss are launching the new CDASplatform with improved features to supportevolving requirementsNEW CDAS Features in 2011:• Windows 7 Compatability• Specific Gas Bottles Associated to QAL3Test• Simultaneously Performs Multiple QAL3Tests from a Mixed Gas Bottle• Multi Language SupportEN14181CDAS eases the burden of EN14181 compliance as itallows application of QAL2 calibration functions andperforms automatic QAL3 TestingDual RedundancyTo maximise data capture, two copies of CDAS canbe set up in a duty/standby dual redundantarrangement. The standby machine connects to theduty machine and is supplied with live data. If thestandby machine detects that the live data supply isinterrupted then it will attempt to collect data from theinstruments itself.11Tel: 0151 666 8300www.a1-cbiss.com12


Service & SupportThe a1-cbiss philosophy differs from ourcompetitors in that we firmly believe quality shouldcontinue far beyond supply. All systems aresupported by our dedicated service department toprovide repair, calibration, preventative maintenance,software support and remote diagnostics - 24 hour /7 days per week to our customersWith the largest dedicated <strong>CEMS</strong> service supportnetwork in the industry, a1-cbiss have fully factorytrained industry specialists on hand to provide fullcustomer service and supportOngoing service & support is integral to the a1-cbissoffering. With a comprehensive service & supportpackage that is fully flexible to meet customerspecific, legislative or budgetary requirements,offering peace of mind that equipment is covered forall eventualities• Regional service structure• Dedicated engineers allocated to your siteto improve customer relations and quality ofservice• Most experienced <strong>CEMS</strong> service team in theUK with combined industry experience of over150 yearsPaul MorganSouthern Area Sales &Service ManagerService Contract BenefitsOur wealth of knowledge and experience ensuresyou meet legislative requirements with no downtime,therefore maximising your investment. Additionalbenefits include:• Flexibility to suit your requirements• EN14181 consultancy and compliance support• OMA - Pre audit check and OMA auditattendance• Full operator system training• Reduced downtime to improve plant efficiency• Unrivalled industry experience• Regional on-call service engineer 24/7Typical Service Contract Comprises:• 4 scheduled service and calibration visitsper year• All parts, labour and travel inclusive• Guaranteed response time from 6 hours• Site allocated service engineer• Fully inclusive of warranty and breakdowncover• 24/7 regional service support• Remote diagnostics support• Legislation compliant servicedocumentation• EN14181 compliant functional checks• Comprehensive stockists of critical spareparts and consumablesTraining:a1-cbiss can provide a comprehensive trainingpackage to meet all of your site requirements. Ourservice department can also provide full systemtraining for your staff, advice and support for OMAsurveys and advice and guidance on all relevantlegislation. We offer structured training programs forall of our <strong>CEMS</strong> equipment, which would comprise ofthe following topics:• Advanced system technical training• Advanced system CDAS training• Objective <strong>CEMS</strong> specification consultancy to meetpermit requirements• Legislation specific• EN14181 - QAL313Tel: 0151 666 8300www.a1-cbiss.com14


Client Reference ListsVeolia, Ellesmere PortDalkia, ChiltonLondon Waste, EdmontonCNIM, States of JerseyInco Europe, LondonVoelia, TyseleyHampshire Waste, ChinehamHampshire Waste, MarchwoodHampshire Waste, PortsmouthQinetiq Ltd, EssexCoventry & SolihullBorders General Hospital, MelroseWhiterose Environmental Ltd, KentDSTL, WiltshireLakeside EFW, ColnbrookGrundon Waste Management Ltd, BerkshirePeake GB Ltd, CornwallMES, WolverhamptonMES, Dudley,MES, StokeVeolia SELCHP, DeptfordMetso, Markinch ScotlandSlough Heat & Power LtdEON UK Ltd, IronbridgeEON UK Ltd, KingsnorthEON UK Ltd, CastlefordEON UK Ltd, KillingholmeEON UK Ltd, SandbachCoryton Power, Stanford-le-hopeEON UK Ltd, Stoke on TrentEON UK Ltd, RatcliffeClient Testimonials“We became aware of a1-cbiss and their emissions monitoring systems through ouroperational involvement on one of our Contract Energy Management contracts in the North-East of England.We were in the design phase of a new wood chip burning Power Station and, as relativenewcomers to this field, we received a great deal of technical guidance from a1-cbissregarding WID compliance.We were particularly impressed by the fact that the <strong>CEMS</strong> is 100% engineered by a1-cbissincluding the CDAS software and also received a very competitive tender return compared totheir rivals in this field.We look forward to working with them during the commissioning phase of the station.Peter ClearySenior Project EngineerDalkia Energy“”“ ” use and extremely flexible meeting all our site requirements. The a1-cbiss engineers offer”WSP regularly partner with a1-cbiss to ensure our permitting clients get the best technicaladvice and response to their <strong>CEMS</strong> needs.Neal BarkerTechnical DirectorWSP Environment and EnergyWe have been using a1-cbiss since the plant was built for their expertise, technicalguidance and market leading equipment. The equipment we have onsite is the MIR-FTsystem combined with a GR52M FID and the a1-cbiss data acquisition software CDASElite. The complete CEM system has proven to be very reliable and dependable over theyears. One of the key benefits to us is the CDAS elite software package which is easy toexceptional support, as well as being professional and knowledgeable. The a1-cbisslegislative consultancy approach has been invaluable and helped contribute to us achievingone of the highest OMA scores in the industry.Andy McQueenEFW Facility Plant ManagerVeolia Chineham15Tel: 0151 666 8300www.a1-cbiss.com16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!