12.07.2015 Views

Sterile Process Connection, Diaphragm Seals for ... - TechnoMad

Sterile Process Connection, Diaphragm Seals for ... - TechnoMad

Sterile Process Connection, Diaphragm Seals for ... - TechnoMad

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Possible combinationsBourdon tube pressure gauges<strong>Diaphragm</strong> seal Model 990.18, 990.19, 990.20 or 990.21 can be combined witha pressure gauge with bourdon tube if the following application conditionsare taken into account:T Pressure gauge directly combined with diaphragm sealT Temperature rangeprocess: +10 ... +150 °Cambient: +10 ... +40 °CChoice<strong>Process</strong> connection with nominal sizes (DN)20 ... 32 (1½") 40 ... 50 (2") 80 (3") ...Pressure gauge Model 23x.50.63 23x.50.63 23x.50.6323x.50.100 23x.50/30.100 23x.50/30.100Lowest measuring range 0 ... 4 bar 0 ... 2 bar 0 ... 0.6 bar-1 ... 3 bar -1 ... 3 bar -1 ... 1.5 barOverpressure safety(optional) - 2 x full scale value 2 x full scale valueInductive alarm sensors(optional), suitable in zone - possible possible1 and zone 2 (Model 831)Pressure transmitters<strong>Diaphragm</strong> seal Model 990.18, 990.19, 990.20 or 990.21 can be combined witha pressure transmitter Model S-10 or universal transmitter Model UT-10if the following application conditions are taken into account:T Pressure transmitter directly combined with diaphragm sealT Temperature rangeprocess: +10 ... +150 °Cambient: +10 ... +40 °CChoice<strong>Process</strong> connection with nominal sizes (DN)20 ... 25 (1") 32 (1 ½") ... 50 (2") 80 (3") ...Lowest measuring range 0 ... 2.5 bar 0 ... 1 bar 0 ...400 mbarFurther gauge variants and lower pressure ranges can be supplied after technical verification and clarification by WIKA.Ordering in<strong>for</strong>mationModel / <strong>Process</strong> connection (with union nut or male thread) / Nominal sizes (DN) / Material of wetted parts / Assembly, ifnecessary length of capillary / Fill fluid / Pressure gauge model / <strong>Process</strong> conditions as per questionnaire / Optional extrasresp. special version requiredModifications may take place and materials specified may be replaced by others without prior notice.Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing.Page 6 of 6WIKA Data Sheet DS 99.40 · 02/2005WIKA Alexander Wiegand GmbH & Co. KGAlexander-Wiegand-Straße 3063911 Klingenberg/GermanyPhone (+49) 93 72/132-0Fax (+49) 93 72/132-406E-Mail info@wika.dewww.wika.de9029486 02/2005 GB

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!