Automatic swing door systems<strong>GEZE</strong> <strong>ECturn</strong>Technical data<strong>ECturn</strong>, EMD,TSA 160 NTAutomatic swingdoor systemsProduct features<strong>GEZE</strong> <strong>ECturn</strong>Height60 mmWidth580 mmDepth60 mmLeaf weight (max.) 1-leaf125 kgLeaf width (min.-max.)650 – 1100 mmSoffit depth (max.)*200 mmDoor overlap (max.)*50 mmDrive typeElectromechanicalDoor opening angle (max.)* 110 °DIn left●DIn right●Transom installation opposite hinge side with link arm●Transom installation opposite hinge side with guide rail●Transom installation hinge side with guide rail●Door leaf installation opposite hinge side with guide rail●Door leaf installation hinge side with guide rail●Door leaf installation hinge side with link arm●Mechanical latching action -Electrical latching action●Electrical closing sequence control -Mechanical closing sequence control -Disconnection from mainsMain switch in the driveactivation delay (max.)10 SOperating voltage (min.)110 VOperating voltage230 VFrequency of supply voltage50 – 60 HzCapacity rating75 WPower supply for external consumers (24 V DC)600 maTemperature range -15 – 50 °CEnclosure rating IP 20Operating modesOff, automatic, Permanently open, nightType of functionFully automaticautomatic function●Low-energy function●Servo function -Key function●Inverse function (opening by spring force) -Vestibule function -Obstruction detection●automatic reversing●Push & goadjustableOperationProgramme switch TPS, Programme switch integrated in the driveParameter settingProgramme switch DPS, Controllerapprovals DIn 18650Suitable for fire proof doors -● = YES- = nOT aVaILaBLE* = DEPEnDInG On THE TYPE OF InSTaLLaTIOnnOTE: THE MaxIMuM POSSIBLE LEaF WEIGHT In RELaTIOn TO LEaF WIDTH Can BE FOunD In THE CHaPTER On aREaS OF aPPLICaTIOn (DIaGRaMS)!2<strong>GEZE</strong> AUTOMATIC DOOR SYSTEMS


Automatic swing door systems<strong>GEZE</strong> <strong>ECturn</strong>Installation with mounting plate (A) and direct installation (B)<strong>ECturn</strong>, EMD,TSA 160 NTABAutomatic swingdoor systemsø16114278415390,53025753ø16113178390,526663332120 428,5120 428,52a = Installation with mounting plateB = Direct installation1 = Concealed line-feed for low-voltage connection and mains cable2 = Dimensional reference is middle of hinge3 = Concealed line-feed for low-voltage connectionTransom installation with guide rail on the opposite hinge side, single-leafDrawing no. 70107-ep02Soffit depth (max.) 30 mm56044*33 4230*16 161060135722843* = Direct installation1 = <strong>ECturn</strong> space requirement2 = Guide rail space requirement3 = GC 334 space requirement4<strong>GEZE</strong> AUTOMATIC DOOR SYSTEMS


Automatic swing door systems<strong>GEZE</strong> <strong>ECturn</strong>Installation with mounting plate (A) and direct installation (B)AB<strong>ECturn</strong>, EMD,TSA 160 NT1ø16575415390,53021427821633390,5266131782Automatic swingdoor systems498,5 70ø16498,570ø1633a = Installation with mounting plateB = Direct installation1 = Concealed line-feed for low-voltage connection2 = Concealed line-feed for low-voltage connection and mains cable3 = Dimensional reference is middle of hingeTransom installation with link arm on the opposite hinge side, single-leafDrawing no. 70107-ep03Soffit depth (max.) 200 mm56044*4216 16601352634*34752863* = Direct installation1 = <strong>ECturn</strong> space requirement2 = Link arm space requirement3 = GC 334 space requirementSwing Door Systems5


Automatic swing door systems<strong>GEZE</strong> <strong>ECturn</strong>Installation with mounting plate (A) and direct installation (B)<strong>ECturn</strong>, EMD,TSA 160 NTABAutomatic swingdoor systems1575415390,5302142782ø161633390,5266131782ø1642,528742,5 28733a = Installation with mounting plateB = Direct installation1 = Concealed line-feed for low-voltage connection2 = Concealed line-feed for low-voltage connection and mains cable3 = Dimensional reference is middle of hingeDoor leaf installation with guide rail on the hinge side, single-leafDrawing no. 70107-ep04Door overlap (max.) 50 mm5609944*4216 16601103332*2435* = Direct installation1 = Guide rail space requirement2 = <strong>ECturn</strong> space requirement3 = GC 334 space requirement6<strong>GEZE</strong> AUTOMATIC DOOR SYSTEMS


Automatic swing door systems<strong>GEZE</strong> <strong>ECturn</strong>Installation with mounting plate (A) and direct installation (B)1AB<strong>ECturn</strong>, EMD,TSA 160 NT120 428,5120 428,5ø16278142ø16278131Automatic swingdoor systems302390,54155752663 390,513633a = Installation with mounting plateB = Direct installation1 = Dimensional reference is middle of hinge2 = Concealed line-feed for low-voltage connection and mains cable3 = Concealed line-feed for low-voltage connectionDoor leaf installation with link arm on the hinge side, single-leafDoor overlap (max.) 200 mm5 6019944*423534*16 16 26602110 343* = Direct installation1 = <strong>ECturn</strong> space requirement2 = Link arm space requirement3 = GC 334 space requirementSwing Door Systems7


Automatic swing door systems<strong>GEZE</strong> <strong>ECturn</strong>Installation with mounting plate (A) and direct installation (B)<strong>ECturn</strong>, EMD,TSA 160 NTAB11Automatic swingdoor systemsø16278142287 42,53ø16278131287 42,53302390,5415575266390,5633a = Installation with mounting plateB = Direct installation1 = Dimensional reference is middle of hinge2 = Concealed line-feed for low-voltage connection and mains cable3 = Concealed line-feed for low-voltage connectionDoor leaf installation with guide rail on the opposite hinge side, single-leafDrawing no. 70107-ep05Soffit depth (max.) 20 mm5 60144*4260163332*16993511023* = Direct installation1 = Guide rail space requirement2 = <strong>ECturn</strong> space requirement3 = GC 334 space requirement8<strong>GEZE</strong> AUTOMATIC DOOR SYSTEMS


Automatic swing door systems<strong>GEZE</strong> <strong>ECturn</strong>Installation with mounting plate (A) and direct installation (B)AB<strong>ECturn</strong>, EMD,TSA 160 NT1 2498,5100581223ø161 2498,5 100583ø16Automatic swingdoor systems282370,5395555111246370,5613a = Installation with mounting plateB = Direct installation1 = Concealed line-feed for low-voltage connection2 = Dimensional reference is middle of hinge3 = Concealed line-feed for low-voltage connection and mains cableLegend for the cable diagramsCable1 = nYM-J 3 x 1.5 mm 22 = J-Y(ST)Y 1 x 2 x 0.6 LG3 = J-Y(ST)Y 2 x 2 x 0.6 LG4 = J-Y(ST)Y 4 x 2 x 0.6 LG5 = LiYY 2 x 0.25 mm 26 = LiYY 4 x 0.25 mm 27 = Scope of supply sensor strip or LiYY 5 x 0.25 mm 28 = Route empty pipe with pull-wire inner diameter 10 mmNotes• Cable diagrams can also be prepared for specific building projects after receipt of order• Version of standard cable diagrams in accordance with <strong>GEZE</strong> specifications• Cable routing according to VDE 0100• allow the cable for the drive to project at least 1500 mm out of the wall1) Door transmission cable (included in the scope of supply for sensor strip)2) Cable exit for door drive, see installation drawings for <strong>ECturn</strong> 70107-ep01 to -ep063) Cable including in the scope of supply for the sensor4) + 5) Connection box for mains supply and control cable combined on site. Mains supply and control cable must be wired in separate terminalspaces.4) Mains connection box WxHxD min. 65 x 65 x 575) Control cable box WxHxD min. 94 x 65 x 57 with PG-11 ductAbbreviationsHS = Main switchnOT = Emergency-stop switchKB = Contact sensor authorisedPS = Programme switchST = Emergency stopKI = Contact sensor insideKa = Contact sensor outsideTOE = Door openerRM = Bar messageSwing Door Systems9


Automatic swing door systems<strong>GEZE</strong> <strong>ECturn</strong><strong>ECturn</strong>, EMD,TSA 160 NTIIIIIIAB+2004)Automatic swingdoor systems1 1 1 133338IV38BKAKIB<strong>ECturn</strong>max. 1005)max. 300HSVNOTVKBPSSTKI3)KA3)B/2B/2IIIIIIIVV= Mains supply cable 230 V / 50 Hz= Fuse 10 a= Connected load 230 W 1 a= and / Or= Option1-leafIIIAA4)B B5)1<strong>ECturn</strong> 2)7 <strong>ECturn</strong> 2)8GC 334 GC 3341)88TOERMTOERMIII= Transom installation concealed line-feed= Door leaf installation1 0<strong>GEZE</strong> AUTOMATIC DOOR SYSTEMS