Ending Entire System Server - Software AG Documentation
Ending Entire System Server - Software AG Documentation
Ending Entire System Server - Software AG Documentation
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Common <strong>Entire</strong> <strong>System</strong> <strong>Server</strong> Features<br />
■ Position parameter 1: NODE-ID of the <strong>Entire</strong> <strong>System</strong> <strong>Server</strong> or -f or --file<br />
With Online-Trace, the numerical NODE-ID is specified to indicate MONITOR-MODE, whereas -f or<br />
--file causes the dataset assigned using the DDNAME TRACEIN (z/OS), TRACIN (SYS001) DLBL<br />
or TLBL (z/VSE) or logical file name TRIN (BS2000/OSD) to be processed as input (FILE-MODE ).<br />
■ Keyword parameters:<br />
■ -d | --displ<br />
The prepared result data is transferred to SYSPRINT (z/OS), SYSLST (z/VSE) or SYSOUT<br />
(BS2000/OSD).<br />
■ -n | --ntrout<br />
If this parameter is specified, no output file will be generated with the prepared result data<br />
using the logical file name TROUT. This key is accepted only if the parameter -d | --displ<br />
has also been specified.<br />
■ -p | --poll<br />
This option causes ESYTRACE in the MONITOR-MODE not to terminate the program at the end of<br />
the buffer, but to wait for further data in the trace buffer. This enables a running ESY node<br />
to be monitored in real time. Under z/VSE, additional steps are required before this can be<br />
used.<br />
For the format of the optional output file, the following file attributes are required:<br />
Option<br />
BS2000/OSD<br />
z/OS<br />
z/VSE<br />
Explanation<br />
Size: SPACE=(4,4)<br />
Features: BLKSIZE=(STD,2),FCBTYPE=SAM,RECFORM=V<br />
LRECL=315, RECFM=FBA<br />
LRECL=315<br />
The following parameters are recommended for the two modes:<br />
■ parameter list for MONITOR-MODE: NODE-ID --displ --poll<br />
■ parameter list for FILE-MODE: --file<br />
The output file generated is useable only for error analysis by <strong>Software</strong> <strong>AG</strong> support. It contains<br />
no user data whatsoever other than the user ID.<br />
For real-time monitoring of error situations, these steps should be used:<br />
1. Start <strong>Entire</strong> <strong>System</strong> <strong>Server</strong><br />
2. Start diagnosis program ESYTRACE in MONITOR-MODE with the --poll option.<br />
ESYTRACE will format trace data as soon as it is placed in the buffer.<br />
84<br />
Administration