12.07.2015 Views

General Test Equipment - Koehler Instrument Co., Inc.

General Test Equipment - Koehler Instrument Co., Inc.

General Test Equipment - Koehler Instrument Co., Inc.

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Automatic Distillation of Petroleum ProductsDry Point Detection as Standard Feature- Dry point can be detectedvisually or by automatic detection for ASTM D850 and D1078 test methods.The unit is delivered ready with the PC board components already included asstandard to perform the dry point analysis. Simply order the Automatic DryPoint Detection Kit for Solvents (see Ordering Information at right) whichincludes dry point thermocouple, 200mL flask and PTFE plug to perform drypoint detection analysis automatically.Ready for Groups 1 - 4 and more-Each <strong>Koehler</strong> Automatic DistillationAnalyzer 5000 Series comes ready with the equipment, accessories andfeatures as standard to properly run distillation groups 1 to 4 per ASTM D86and related test specifications. No additional accessories are required. TheWindows ® -based software package allows simple operator selection of theprogrammed settings for each distillation protocol. No complicated routinesare needed to set up the unit. User defined programs are easily created forcustomization of the analyzer.Calculated Cetane Index-Calculated cetane index is a useful tool forestimating ASTM D4737 cetane number where a test engine is notavailable for determining this properly. It may be conveniently employed forapproximating cetane number where the quantity of sample is too small for anengine rating. In cases where the cetane number of a fuel has been initiallyestablished, the index is useful as a cetane number check on subsequentsamples of that fuel, provided its source and mode of manufacture remainunchanged. The Cetane index is automatically calculated at the end of the testif all the necessary variables are entered and is a component of the Windows ® -based software which comes standard with the unit.Carbon Residue on 10% Distillation Residue-As per section 10, ASTMD189 the procedure for carbon residue of light distillate oils can be performed.<strong>Inc</strong>luded AccessoriesDistillation Flask, 125mL with MarkingsCeran Plate, 25mm dia. holeCeran Plate, 38mm dia. holeCeran Plate, 50mm dia. hole3 Point Calibrated PT100 Thermometer with Cable and PlugSpecial Graduated Receiver Cylinder with BaseWiper for <strong>Co</strong>ndenser TubeDropping PlateTeflon Plug for 125mL FlaskSilicone Plug for Flask Side ArmDry Point Detection BoardWindows ® -based Automatic Distillation SoftwareK45703-TS Automatic Distillation Analyzer withTouch Screen Display and Integrated PCOrdering InformationAutomatic Distillation Analyzer 5000 SeriesCatalog No.K45603Automatic Distillation Analyzer, 120V 60HzK45604Automatic Distillation Analyzer, 230V 50/60HzK45703-TS Automatic Distillation Analyzerwith Touch Screen Display and Integrated PC,120V 60HzK45704-TS Automatic Distillation Analyzerwith Touch Screen Display and Integrated PC,230V 50/60HzAccessoriesK45634Distillation Flask, 125mL with MarkingsK45635PTFE Centering Stopper for 125mL FlaskK45655Ceran Plate, 32mm dia. holeK45656Ceran Plate, 38mm dia. holeK45657Ceran Plate, 50mm dia. holeK45656-A Ceran Plate, 25mm dia. holeK45650PT100 Thermometer with Cable and PlugK45651-E Special Graduated Receiver Cylinder (with base)K45651-B Special Graduated Receiver Cylinder (without base)K45601-03014 <strong>Co</strong>ndenser Tube Cleaning AssemblyK45668Dropping PlateK45654-A Flask 200mL with Silicon PlugK45652-C Silicone PlugK45654Automatic Dry Point Detection Kitfor D850 and D107857

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!