<strong>DB</strong> <strong>200</strong><strong>Sound</strong> <strong>level</strong> <strong>meter</strong>Inte<strong>gr</strong>ating-averaging with storage functionFIVE DIFFERENT MEASUREMENT MODES- Mode 1 : Conventional sound <strong>level</strong> <strong>meter</strong>- Mode 2 : Conventional sound <strong>level</strong> <strong>meter</strong> with storage.- Mode 3 : Conventional and inte<strong>gr</strong>ating-averaging sound <strong>level</strong> <strong>meter</strong>- Mode 4 : Inte<strong>gr</strong>ating-averaging sound <strong>level</strong> <strong>meter</strong> with storage.- Mode 5 : <strong>Sound</strong> <strong>level</strong> <strong>meter</strong> “calculator” of two sound sources.MEASURED VALUES- Weighted sound <strong>level</strong> : L- Equivalent continuous <strong>level</strong> : Leq- <strong>Sound</strong> exposure <strong>level</strong> : LE- Peak pressure <strong>level</strong> : LpkRESULTS & ADDITIONAL INFORMATION- Maximum and minimum values, peak values- L01-L10-L50-L90 statistics distribution of measured values.- Presence and percentage of overload input stages, measurement time.- Residual auton<strong>om</strong>y of batteries or battery, measuring capacity remaining.DATA DISPLAYThe <strong>DB</strong><strong>200</strong> sound <strong>level</strong> <strong>meter</strong> is supplied withL<strong>DB</strong><strong>200</strong> software for display data and measurementreport printing.I/O INTERFACELaunching and stopping of themeasurement by external control.Detection of sensitive <strong>level</strong>s for alarmsactivationAnalogue output 0-10V DC.STANDARDSAs per following standards :<strong>Sound</strong> <strong>level</strong> <strong>meter</strong> : NF EN 61672-1(<strong>200</strong>3)- NF EN 60651 (1994) – NF EN60804 (<strong>200</strong>0).CE conformity : EN 61010 – EN 61000generic and as per product standards.


TECHNICAL FEATURESMetrologyAccuracy.................................................Class 2Microphone type....................................Electret ICP – ½'' -Sensibility : 15 mV/PaMeasuring type.......................................Free-fieldMeasurement dynamic..........................Lp/Leq : 100 dB -Lpk : 50 dBA-weighted measurement range...........30-130 dBC-weighted measurement range...........35-130 dBZ-weighted measurement range...........35-130 dBPeak channel measurement range.......83-133 dBX frequency weighting ..........................A – C – ZY frequency weighting...........................F (fast) – S (slow)I (impulse) – Peak (pk)SOUND LEVEL METERScreen..........................................................................<strong>gr</strong>aphic 6display 240 x 160 pixels – LCD monochr<strong>om</strong>e 16 <strong>level</strong>s –digital and analogue display – 3D effect on displayKeypad.........................................................................8 sensitive keysInternal clock...............................................................permanent, saved by internal batteryMemory module..........................................................inte<strong>gr</strong>ated Micro SD card type – data transfer by USB cableEnvironment................................................................fr<strong>om</strong> -10 °C to +50 °CHumidity.......................................................................fr<strong>om</strong> 0 to 90% HRDimensions (L x l x e).................................................270 x 70 x 40 mmWeight (including batteries).......................................280 <strong>gr</strong>Fixing...........................................................................Insert at rear for fixing on tripodOPERATING●Windshield●Transport case●3 LR6-AA batteries●Calibration certificate●Transfer cable USB type●L<strong>DB</strong><strong>200</strong> softwareLogging time for short Leq (DI).....................fr<strong>om</strong> 1 s to 60 sSampling for Lp..............................................fr<strong>om</strong> 1 s to 60 sMeasured values.............................................LXY – LXYmax – LXYmin -LXeq,T – LXeq,DI – LXE –LXeq,DImax – LXeq,DIminStatistics indices LXN onLp and Leq samples.......................................LX01 – LX10 – LX50 –LX90 – LX95 – resolution 1dB.Measured values simultaneously -Storage mode..................................................All according LXY or LXeq choiceDetection andpercentage of overload..................................Alarm <strong>gr</strong>aphics and calculation ofpercentage during the storage5 measurement modes...............................................conventional – conventional with storage – conventional and inte<strong>gr</strong>ating – inte<strong>gr</strong>ating withstorage – calculator S1 + S2Storage and measurement capacity..........................L-Leq mode : 24hL-St or Leq-St mode : according sampling or elementary logging timeMemory capacity : 25 periods of 86 500 values – ex : 24 hours / Leq 1sI/O Interface : ..............................................................Output 0-10V DC : 0-130dBStart/Stop measurement order : TTL <strong>level</strong> maximal 5VOutput for alarm activation : TTL <strong>level</strong> 3.3 VMeasurement launching.............................................By keyboard or I/O controlledPower – Auton<strong>om</strong>y......................................................Batteries : 3 x LR6/AA – minimum auton<strong>om</strong>y : 15 hours at 20 °COptional rechargeable Li-Ion battery : minimum auton<strong>om</strong>y :more than 24 hat 20 °CElectrical power adapter 5V, USB format.Guarantee....................................................................2 yearsSUPPLIED WITHACCESSORIES●Tripod●Acoustic calibrator class 2●Rechargeable Li-Ion battery●Charger – electrical power adapter USB type●Jack cables for I/O interfaceAcousticcalibratorFTang – <strong>DB</strong><strong>200</strong> – 07/10/10 – RCS (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!