2.2.2 FusesThe fuse holders are located in the power connector assembly just below the voltage selector.Illustration 2–3 Fuse HolderFor 100 to 120 VAC operation, use the fuse installed at the factory. For 220 to 240 VAC operation,use the slow-blow fuse located in a hardware kit within the transmitter packaging.Consult the following table:Transmitter Input Power FuseFM30 100–120 V 3 A220–240 V 1.5 AFM150 100–120 V 6.3 A220–240 V 4 AFM300 100–120 V 12.5 A220–240 V 6.3 AIllustration 2–4 Fuse Reference Table2-4 FM30/FM150/FM300 User’s <strong>Manual</strong>