12.07.2015 Views

DNA Plant HTS 96 Kit

DNA Plant HTS 96 Kit

DNA Plant HTS 96 Kit

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

6. Removing of ethanolPlace the waste tray inside the vacuum manifold and close the manifold with the top plate. Placethe <strong>DNA</strong> Binding Plate C onto the rubber joint of the Invisorb ® <strong>96</strong> Vacuum Manifold top plate.Switch on vacuum source and apply vacuum for at least 20 min for complete remove of allethanol. Switch off vacuum and ventilate the vacuum manifold. Take the <strong>DNA</strong> Binding Plate Cout of the manifold and place it on a clean paper towel. Remove the manifold top plate and thewaste tray from the base.7. Elution of the genomic <strong>DNA</strong>Place a new 1.0 ml Collection Plate inside the base of the Invisorb ® <strong>96</strong> Vacuum Manifold andclose the manifold with the top plate. Place the <strong>DNA</strong>-Binding Plate C onto the rubber joint of theInvisorb ® <strong>96</strong> Vacuum Manifold top plate. Add 60 µl Elution Buffer D directly onto themembrane in each well and incubate for 5 min. Switch on vacuum source and apply vacuumfor at least 5 min until the transfer into the wells of the 1.0 ml Collection Plate is complete. Add60 µl Elution Buffer D again directly onto the membrane in each well. Switch on vacuumsource and apply vacuum for at least 5 min until the transfer into the wells of the 1.0 mlCollection Plate is complete.To remove adherent drops from the outlets of the <strong>DNA</strong>-Binding Plate C strike several times withthe flat hand on the top of the plate. Switch off vacuum and ventilate the vacuum manifold. Takethe <strong>DNA</strong>-Binding Plate C very carefully out of the manifold in order to avoid crosscontaminationswith adherent fluid. Discard the <strong>DNA</strong>-Binding Plate C. Remove the manifold topplate from the base and take the 1.0 ml Collection Plate with the eluted <strong>DNA</strong> out of the manifold.Cover the plate with the sealing foil.Note: Elution with prewarmed Elution Buffer D (up to 80 °C) will increase also the final yield.Invisorb ® <strong>96</strong> Vacuum ManifoldThe Invisorb ® <strong>96</strong> Vacuum Manifold contains acrylglas. To avoid any problems with thematerial please note the following instruction:1. Avoid a long incubation with ethanol or Binding Buffer P containing solutions.2. Clean up the manifold after using with water immediately and dry it.3. Always use the waste tray.15Invisorb ® <strong>Plant</strong> <strong>DNA</strong> <strong>HTS</strong> <strong>96</strong> <strong>Kit</strong> /V and C 1010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!