12.07.2015 Views

Genesis CD-15G/25G - DEL Ozone

Genesis CD-15G/25G - DEL Ozone

Genesis CD-15G/25G - DEL Ozone

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Genesis</strong> <strong>CD</strong>–<strong>15G</strong> and <strong>CD</strong>–<strong>25G</strong> Installation & Operations ManualSECTION 1 General Information1A. DescriptionThe <strong>Genesis</strong> Corona Discharge series ozonegenerator described in this manual is designedto provide the benefits of ozonated water in anenvironmentally safe and effective manner. Thehigh quality, specially engineered componentsensure efficient ozone output and reliableperformance.39.2 995The <strong>Genesis</strong> <strong>CD</strong> ozone generator is safe andharmless to your equipment if installed properly.A24.1 61312.3 31124.4 620ADIM "A" = 6 [152] MIN CLEARANCE11.7 297DOOR SWINGR24.5 621SECTION 2 Installation2A. Location<strong>CD</strong>–<strong>15G</strong> amd <strong>CD</strong>–<strong>25G</strong> are designed for eitherfloor or wall mounting in a clean, protected area,either indoors or outdoors. Locate generator outof reach of sprinklers or drainage spouts. Allowsufficient access for maintenance and all tubingand electrical wires. Generators must not beplaced in locations where ambient ozone levelsexceed 0.01 PPM.2B. MountingNOTE: Do not remove compressor packingmaterial until unit has been mounted.2B-1. Wall Mount Option1. Attach two mounting brackets to wall usinganchors appropriate for mounting surface.See Figure 2.2. Using 1/4"-20 bolts (with washers as shown)secure generator to mounts.2B-2. Floor Mount Option1. Use the four 1/4"-20 bolts with washers tosecure feet to bottom of cabinet.2. Stand upright and securely fasten to concreteslab using appropriate anchors and bolts.MOUNTINGBRACKETS (2)4.0 102MIN. CLEARANCE(IF WALL MOUNTED) 4.0 102Figure 11B. Specifications1B-1. For detailed specifications refer to the ozonegenerator specification label located on the insideof the door on the unit.1B-2. Location Requirements*:Mounting: Floor or wall mount in a clean, protectedarea using supplied brackets.Ventilation: Room should provide 6 air changesper hourAmbient Temp.: 40–100˚F (5–38˚C)* Protection from weather elements must be providedfor outdoor installations. Operating outside of therecommended temp. ranges may result in damagenot covered under the manufacturer’s warranty.Figure 2: Wall Mount1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!