Base Hinged Medium Duty168mm base400W FloodlightFor 400W floodlighting installations,where the control gear is integralwithin the floodlight, the standardcolumn can be supplied witha separate fuse cut-out fittedwith a 10A fuse (code ELSAB1/10Afor single floodlight, ELSAB12/10A fortwin floodlights).1 Set of Control GearWhere the column is carrying one (A) or two (B) 1kWfloodlights (see column pages for head and windload capacities), the control gear is mounted in apurpose designed steel galvanised box fitted to thecolumn base. The door is fitted with a lock. Theconnection box with single or twin MCBs is mountedin the column base, accessed by lowering thecolumn.Base Hinged Heavy Duty219mm base1 Set of Control GearWhere the column is carrying one1kW (A) or 2kW (C) floodlight (seecolumn pages for full wind loadingcapacities), the control gear ismounted in the base of the column,accessed by lowering the column.The connection box with a singleMCB is mounted in the lower columndoor. Max. 16mm² incoming cable,loop in/out.2 Sets of Control GearWhere the column is carrying 2 sets of 1kW (B) or2kW (D) floodlights (see column pages for full windloading capacities), the control gear is mounted in apurpose designed steel galvanised box fitted to thecolumn base. The door is fitted with a lock.The connection box with twin MCBs is mounted inthe column base, accessed by lowering the column.2.5mm² flex is fitted between the control gear andthe top of column, looped securely ready forinstallation.Floodlight Schematic Wiring Diagram (1kW)AB2No 1kW ballastsFlex to gear trayFlex to gear trayCut out for 1No 1kWfloodlight. Contains a32A isolator and 16Asingle pole MCBCut out for 2No 1kWfloodlights. Contains a32A isolator and 2No16A single pole MCBs1kW gear tray securedinto box or mast basedepending on size ofbase compartmentTerminals to acceptincoming flexes fromcut out and also flexesto the luminaire2No capacitorsper ballastFloodlight Schematic Wiring Diagram (2kW)CD2No 2kW ballastsFlex to gear trayFlex to gear trayCut out for 1No 2kWfloodlight. Contains a32A isolator and 16Adouble pole MCBCut out for 2No 2kWfloodlights. Contains a32A isolator and 2No16A double pole MCBs2kW gear tray securedinto box or mast basedepending on size ofbase compartmentTerminals to acceptincoming flexes fromcut out and also flexesto the luminaireProfessional lighting systems to suit any project. Call 01623 518 333 39

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!