12.07.2015 Views

Download Magazine

Download Magazine

Download Magazine

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ChromJournalInnoVAtIVe pRoducts foR chRomAtoGRAphyAnalysis of testosterones usinga core enhanced technologyAccucore hplc columnJoanne Gartland, Thermo Fisher Scientific, Runcorn, Cheshire, UKThis demonstrates theuse of the ThermoScientific Accucore RP-MS HPLC column forthe fast analysis of threetestosterones.Introductionaccucore HPlC columns use Core enhancedTechnology to facilitate fast and high efficiencyseparations. The 2.6 μm diameter particles arenot totally porous, but rather have a solid coreand a porous outer layer. the optimised phasebonding creates a series of high coverage,robust phases. accucore RP-MS uses anoptimised alkyl chain length for more effectivecoverage of the silica surface. this coverageresults in a significant reduction in secondaryinteractions and as a result highly efficient peakswith very low tailing. the tightly controlled 2.6μm diameter of Accucore particles providesmuch lower backpressures than typically seenwith sub 2 μm materials. 11-ketotestosterone,19-nortestosterone and epitestosterone are allrelated to testosterone. 11-ketotestosteroneis an oxidised form of testosterone.19-nortestosterone contains an additionalmethyl group in comparison to testosteroneand epitestosterone and is an inactive epimer oftestosterone. all three compounds are anabolicsteroids, which promote protein synthesis withincells, particularly in muscles. 19-nortestosteronefigure 1.Chromatogram for 11-ketotestosterone (1), 19-nortestosterone (2) andepitestosterone (3) separated on an accucore RP-MS 2.6 μm100 × 2.1 mm columnoccurs naturally at low levels (0.4 ng/ml) in thebody and is routinely tested for in athletes.the separation of these three compounds andmore significantly the speed of analysis aredemonstrated in this application.experimental conditionssample preparationWorking standard contained 50 μg/ml of eachtestosterone in mobile phasecolumnaccucore RP-MS 2.6 μm, 100 × 2.1 mm (Cat.no. 554-1885)Measured pressure: 300 barAccela hplc systemColumn temperature: 40 °CInjection volume: 1 μlFlow rate: 0.6 ml/minUV detection: 54 nmmobile phase60:40 (v/v) water/acetonitrileconsumablesHPlC grade waterHPlC grade acetonitrileNSC Mass Spec Certified 2 ml clear vial withblue bonded PtFe silicone capResultsthe analysis was carried out on an accucore RP-MS 2.6 μm, 100 × 2.1 mm column.11-ketotestosterone, 19-nortestosterone andepitestosterone eluted in under 2 minutes(Figure 1).Replicated injections of the testosterone mixshowed that accucore RP-MS produced stableand reproducible results (table 1).table 1. Method precision (%RSD) for 11-ketotestosterone, 19-nortestosteroneand epitestosterone (data calculated from six replicate injections)Peak 111-ketotestosteronePeak 219-nortestosteroneAsymmetry 1.48 1.28 1.11%RSD Tr 0 0.05 0.06%RSD peak area 0.31 0.26 0.44Peak 3epitestosteroneconclusionsaccucore RP-MS columns successfullyseparated 11-ketotestosterone,19-nortestosterone and epitestosterone in lessthan 2 minutes, providing an excellent choice forthe fast analysis of testosterones, allowing highsample throughput.DescriptionCat. No.Accucore RP-MS 2.6 μm, 100×2.1 mm 554-188510VWR InteRnatIonal I chromJournal Issue 12 I 2012

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!