12.07.2015 Views

Lighting - Zero88 Betapack 3 - SXS Events

Lighting - Zero88 Betapack 3 - SXS Events

Lighting - Zero88 Betapack 3 - SXS Events

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ent BETAPACK3 production courtesy Phone: USER of and GUIDE Audio-Visual 0870 080 2342 ServicesTechnical www.sxsevents.co.ukemail: enquiries@sxsevents.co.ukDMX IndicationWARNINGDO NOT REMOVE THE COVERS WITHOUTFIRST COMPLETELY DISCONNECTING THEBETAPACK3 FROM THE MAINS SUPPLYElectricalThe <strong>Betapack</strong>3 is designed to operate on 230VAC+10% -15% at 50-60Hz (auto sensing). The pack maynot operate satisfactorily outside this specification.The packs may be wired:• Single Phase: 60A 1 phase 2-wire 230V(255V max phase to neutral)Earth leakage less than 1mA• Three Phase Star: 20A 4-wire 230/380V(255V max phase to neutral)Earth leakage less than 1mA• Three Phase Delta: 30A 3-wire 230V(255V max phase to phase)Earth leakage less than 4mA- Max total load: 13.9kW @ 230V- Load per channel: 0.1A Min; 10A Max- No load consumption: 10W- Rise Time: 80uS- Triac Type: BTA40-600A/BIf used in conjunction with MCBs, to avoid nuisancetripping use high inrush current (Type K) MCBs.OnFlashFastFlashSlowOffMechanical- Height: 175mm- Width: 440mm- Depth: 195mm- Weight: 8.0kg (17.6lb)CoolingDMX dimmer data (start byte of00) being received OK.DMX data being received, but notdimmer data (start byte of 00)DMX data errors occurring.No DMX data being received.Ambient Temperature: 0 to +40ºC.The <strong>Betapack</strong>3 is convection cooled, and includes atemperature sensor which monitors the internaltemperature. If the temperature rises above the normaloperating level the outputs are first reduced, thenswitched off altogether until the temperature falls backto a safe level.The table below shows how the <strong>Betapack</strong>3 will reactunder these conditions. (Note: The temperature shownon the display will be the actual temperature not therounded figures given below)<strong>Lighting</strong> loads may be resistive or inductive and includetungsten, transformer driven low voltage (e.g. pinspots),and quartz halogen. Electronic transformers must besuitable for leading edge dimming.Portable Appliance TestingWARNING The <strong>Betapack</strong>3 will fail the portableappliance high voltage test as it has capacitorsconnected between Live 1/2/3 and Earth, and betweenNeutral and Earth, to enable it to comply with CEregulations.DMX ConnectionsConforms to USITT DMX512-A (isolated).One male and one female 5 pin XLR connector. DMXline is automatically terminated when the loop-throughplug is not inserted. The pin assignment is:Pin 1Pin 2Pin 3Pin 4Pin 50VDMX- (RS485 B line)DMX+ (RS485 A line)ReservedReservedNotes:TemperatureOutput Levels(% of control)Maindisplay95ºC 0% “hot”sensor fault 100% “err”Zero 88 <strong>Lighting</strong> Ltd reserves the right to make changes to theequipment described in this manual without prior notice.This equipment is designed for professional stage lightingcontrol, and is unsuitable for any other purpose. It should beused by, or under the supervision of, an appropriately qualifiedor trained person.E&OE. <strong>Zero88</strong> <strong>Lighting</strong> Ltd reserves the right to change thespecification without prior notice.Manual Stock Number: 73-682-00 Issue 1.0: July 2006© Zero 88 <strong>Lighting</strong> Ltd 2006www.sxsevents.co.uk<strong>Zero88</strong> <strong>Lighting</strong> Ltd, Usk House, Llantarnam Park, Cwmbran, Gwent NP44 3HD, U.K www.zero88.comTel: +44 (0) 1633 838088 (24hr Answer Phone) Fax: +44 (0) 1633 867880 Email: sales@zero88.com73-682-00 IM8025<strong>Betapack</strong>3ManualIssue1_0.doc Page 7 of 7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!