<strong>INDIAN</strong> <strong>RAILWAY</strong> <strong>PROJECT</strong> <strong>MANAGEMENT</strong> <strong>UNIT</strong><strong>SHIVAJI</strong> BRIDGE, NEW DELHI-110001Phone- 23412260 Fax- 23412556E-mail - adm@irpmu.railnet.gov.inCORRIGENDUM NO. 2Dated 14/12/2009 to Tender Notice No.: IRPMU/W/2009/162/ Additional VSAT (TMS&UTS) Dated:27/10/ 09 (Tender No: 162/2009)Name of WorkSupply, installation, testing and commissioning of 412 remote VSAT locationsover Indian Railway including augmentation work at VSAT HubThe following changes/clarifications are appended in the tender document:-ClauseEstimated Cost of workEarnest MoneySale of Tender DocumentsLast date/time of Tender ReceiptTender Opening Date/TimeDescriptionRs. 64129605 /-(Rs. Six Crore Forty One Lakh TwentyNine Thousand six hundred five only)Rs. 470650/- (Rs. Four Lakh Seventy thousand sixhundred fifty only )up to 29/12/2009 up to 16:00 hrs30/12/2009 up to 14:30 Hrs30/12/2009 at 15:00 hrsSection -1, chapter -3 Schedule of Revised Schedule of Requirements is available on websitesrequirementunder corrigendum 2Other terms & conditions will remain same.The corrigendum is also available in on IRPMU website i.e. www.irpmu.railnet.gov.in, NCR websitewww.ncr.railnet.gov.in & Govt. of India Portal www.tenders.gov.in.(D P Garg)Dy.CSTE/IRPMUFor and on behalf of President of IndiaCopy to:1- C.P.R.O. / NCR for publication of Tender Notice.2- CSTE/NCR/ALD3- FA & CAO/IRPMU for nomination of Official for opening the tender.4- Notice Board/IRPMU5. Notice Board/N.C. Rly. HQs office


Hkkjrh; jsyos ifj;kstuk izcU/ku bdkbZbjdkV ifjlj] f'kokth fczt ('kadj ekfdZV ds ihNs)ubZ fnYyh & 110001bZ- esy irk:- adm@irpmu.railnet.gov.in'kqf)&i= l-2 fnukada14@12@2009nw Hkk:-91-11-23412260/23413756QSDl: - 91-11-23412556fufonk lwpwpuk la-a- vkbZ-Z-vkj-ih-,e-;w@McY;w@2009@162@,Mh'kuy oh-lsV (Vh-,e-,l vksSsj ;w-Vh-,l) fnukadad% 27/10/ 09dk;Z dk ukeHkkjrh; jsyos es 412 yksds'ku es oh-lsV dh lIykbZ, bUlVksys'ku,VsfLVax ,oa dfe'kfuax rFkk gc dk vkxesUVs'ku dk;Z AmijkDsr V.sMj es fuEu la'kks/ku tkjh fd;s tkrs gS Adk;Z dh vuqekfur ykxr: 64129605@& (: Ng djksM bdrkyhl Ykk[k mUurhl gtkj Ng lkS/kjksgj jkf'kikap dsoy ):- 470650@& (:Ik;s pkj yk[k LkRrj gtkj Ng lkS ipkl dsoy)fufonk nLrkostksa ds [kjhnus dh le; fnukad 29@12@2009 16-00 cts rdvof/kfufonk nLrkostksa ds tek djus dk le; fnukad 30@12@2009 dks 14-30 cts rdfufonk [kqyus dh frfFk] le;fnukad 30@12@2009 dks 15-00 ctsSection -1, chapter -3 Schedule ofrequirementvU; VeZl~ ,oa daMh'kUl~ igys tSlh gh gSa Ala'kksf/krSchedule of Requirements 'kqf)&i= l-2 2 ds rgr osclkbV ijmiyC/k gSA'kqf)~&i= vkbZ- vkj- ih- ,e- ;w-, dh osolkbV www.irpmu.railnet.gov.in m-e-jsyos dh osolkbVwww.ncr.railnet.gov.in vkSj Hkkjr ljdkj iksVZy www.tenders.gov.in ij Hkh miyC/k gS A(Mh-ih-xxZ)mi eq[; ladsr ,oa nwj lapkj vfHk;Urk@Vh-,uHkkjrh; jsy ifj;kstuk izcU/ku bdkbZ@ubZ fnYyhd`rs Hkkjr ds jk"Vzifr ds fy, @ dh vksj lsizfrfyfi-1- lh-ih-vkj-vks@m-e- jsyos bykgckn izdk'ku gsrw A2- eq[; ladsr oa nwj lapkj vfHk;Urk m-e- jsyos lwpukFkZ A3- foRr lykgdkj ,oa eq[; ys[kk vf/kdkjh@ vkbZ-vkj-ih-,e-;w lwpukFkZ dI;k VsaMj [kksyus ds fy,foRr izfrfuf/k dk ukfer djsa A4- vkbZ-vkj-ih-,e-;w ubZ fnYyh lwpukiV ds fy, A5- m-e- jsyos eq[;ky; ds lwpukiV ds fy, A


Supply, installation, testing and commissioning of 412 remote VSAT locations over Indian Railwayincluding augmentation work at VSAT HubRevised Schedule of RequirementS No. Item description unit Quantity Rate(inFig)VSAT equipments & their installationRate(inwords)TotalAmount(in Fig)1 Supply of 1.2 m Ku band VSAT Antenna along with Nos. 412connecting cables etc. confirming to RDSO spec. No.RDSO/SPN/ TC/ 87/ 2008 or latest given in section III.2 Supply of 1 KVA online UPS with 2 hrs backup along with No. 300cord & 15 Amps socket and plug etc. confirming to theparameter given in Annexure A3 Supply of VOIP box with 2 RJ11 ports for voice/fax Nos. 300confirming to as per technical specifications given in sectionIII.4 Supply of VSAT IDU with IP router without inbuilt modem Nos. 412for ADB having 2 Watts Out Door Unit, LNA/LNB alongwith IFL cable of required length, additional feed hornmembrane, connector & accessories etc, confirming toRDSO spec. No. RDSO/ SPN/ TC/87/ 2008 or latest givenin section III.5 Supply of Spares for remote VSATs (confirming to RDSOspec. No. RDSO/ SPN /TC/87/2008 or latest) :-(i) 1.2 m Ku band VSAT Antenna as per item No 1. No. 21(ii) 1 KVA online UPS with 2 hrs backup as per item No 2. No. 15(iii) VOIP box as per item No.3 No. 15(iv) VSAT Indoor Unit , 2 watts Out Door Unit & accessories No. 21as per item No 46 Supply, fabrication & installation of Iron Mesh type Nos. 41monkey cage for remote VSATs as per specification anddrawing no. IRPMU/Fixed VSAT/02 given in section III.7 Installation, testing & commissioning of complete VSAT per site 412sites with main Hub including provision of lighteningprotection arrangement, surface preparation, ballasting &IFL conduiting as per drawing & RDSO spec. No. RDSO/SPN/ TC/ 87/2008 or latest given in section III8 Supply, Installation, testing & commissioning of earthing per sitewith two nos. of earths, preparation including supply ofmaterials as per drawing no. SDO/RDSO & technical spec.given in section III along with test certificates of alltechnical parameters.412


HUB EquipmentOPTIONAL ITEMS9 Supply of items for Augmentation, addition and Lot 1modification of Indian Railways HUB installed at ThomsonRoad with Supply of followings as per specification given.9(a) Supply of LDF cable 75 ft. with connectors Nos. 19(b) Supply of Low Noise Amplifier Control cable 75 ft. withconnectors9(c) Antenna Controller Unit – Antenna Drive Unit ControlCable and Azimuth & elevation resolver cables 75 ft. withconnectorsNos. 1Nos. 29(d) Azimuth & Elevation Resolver Nos. 29(e) Feed horn membrane for 9 mtr antenna Nos. 19(f) Distribution Amplifier 2 (DAMP2) Nos. 19(g) Gateway Up-Convertor Module (GUM) Nos. 19(h) IP gateway Server (HP Proliant DL 360 or similar) Nos. 1Sub Total for HUB Supply10 Installation, testing & commissioning charges for items nos.9(a) to 9(h) of augmented portion of HUB equipments to beassociated with existing HUB (to be quoted separately foreach item)11. Training as per Section –II chapter-2 Para 30.11(a) Officers Man week 1811(b) Supervisors Man week 36Note:Sub-total for TrainingTotal1) The rates of optional item (Item no. 9, 10 & 11) shall be taken into tender evaluation.2) The optional item no. 9 shall be procured as per requirement during execution of work. The tenderershall quote the individual unit rates for each item as LS quoted rates rate shall not be considered.3) The tenderer shall quote the installation charges separately for individual items under S. No. (9) of theschedule in Item no. 10.


ANNEXURE AS. No. Parameter1 Input voltage 140-290 VAC, 45-55 Hz. or better.andfrequency2 Output 220-230VAC, 50 Hzvoltage andfrequency3 UPS type ON line4 Battery Type Sealed maintenance free5 Rating 1 KVA6 Backup 2 hours at 1 KVA load7 Protection Over load, over/under voltage andshort circuit protection8 Efficiency at >90%full load9 Output Sine wave waveform10 Total