<strong>WCSF</strong>PerformanceFlammabilityThe product has passed the IEEE1202, Section 7.2 (IEEE 383) FlameTest at both 70,000 and 210,000BTU/hour (Test Report EDR 5348).Heat ageing40 and 60-year life at 90°C establishedusing the Arrhenius method(Test Report EDR 5331).RadiationFunctional operability has beenverified after 2180 kGy (218 Mrad)of gamma exposure (Test reportEDR 5336 & EDR 5389).LOCA<strong>WCSF</strong> <strong>tubing</strong> has been tested toLOCA/HELB profiles based on theguidelines of IEEE 323 and 383(Test Report EDR 5336 & EDR 5389).Key test parameters include:• 40 and 60 year thermal agingat 90 °C• 2180 kGy (218 Mrad) radiationexposure• 30 day LOCA test• 30 day chemical spray• Double peak profile with:max. temperature 218° Cmax. pressure 8 bar (120 psig)QualificationIndividual qualification tests forspecific customer applications arethe responsibility of the user.LOCA profilesTemperature °F (°C)Pressure psig (MPa)450°(232°)400°(204°)350°(177°)300°(149°)250°(121°)200°(93°)150°(66°)100°(38°)140(0.97)120(0.83)100(0.69)80(0.55)60(0.41)40(0.28)Temperature profile5 10 5 100 0Minutes24Pressure profile68 10 12 14 16 18 20 22HoursTime24 4 8 12 16 20 24 28 32Days20(0.14)0(0)5 10 5 100 02468 10 12 14 16 18 20 22 24 4 8 12 16 20 24 28 32Minutes Hours DaysTime