WING REFRIGERATION CONTROLLERSSECTION INDEXFUNCTIONSMODELSWING BASIC - NT, MT AND LT APPLICATIONS – COMPACT/SPLIT FORMATThermostats and “off cycle” defrost multifunctioncontrollersXW10L - XW10V- XW20K - XW20L - XW20LS - XW20V - XW20VSMultifunction controllers for NT - MT - LTXW30VS - XW35VS - XW40K - XW40L - XW40V - XW40VSMultifunction controllers for MT - LTXW60K - XW60L - XW60LS - XW60V- XW60VSKeyboard for multifunction controllers in K format T62 - T64 - T66WING BASIC series parametersWING 200/500 - NT, MT AND LT APPLICATIONS – COMPACT/SPLIT FORMAT – SERIAL OUTPUT“off cycle” defrost advanced multifunctioncontrollersXW220L - XW220KAdvanced multifunction controllers for NTXW230L - XW230KAdvanced multifunction controllers for MT - LTXW260L - XW260K - XW263L - XW264L - XW264K - XW270LXW270K - XW271L - XW271K - XW272KAdvanced multifunction controllers with real time clockfor MT - LTXW563L - XW570L - XW570KKeyboard for advanced multifunction controllers in K format T620 - V620 - T820 - V820 - T821 - V821 - T850 - V850WING 200/500 series parameters3233343536373839394042434431


38x185mmV: 100x64mmL: 38x185mmWING BASIC SERIES: CONTROLLERS FOR NT, MT AND LT APPLICATIONS• Multifunction WING BASIC series dedi<strong>cat</strong>ed to N.T. and L.T. refrigerated appli<strong>cat</strong>ions• LS/VS formats for OEM appli<strong>cat</strong>ions with reduced mounting depth• Innovative and elegant design that enhances the aesthetics and functionality of the final product• Direct live & neutral load connections for reduction of wiring costs• Direct driving of <strong>com</strong>pressors up to 1,2HP, (20A relay inside)• Direct line power supply. No external transformer required• Up to 4 relay outputs and 1 digital input• Up to 6 push buttons with direct action for user friendly interface• Maximum and minimum temperature recording• Hot Key or Prog tool kit connector for a quick and easy programming• 3VA max power absorption• Display with red LED (13,2 mm high)HOW TO ORDERWING L, VWING LS, VSX W- A B C D EX WS - A B C D 0For INOX version and BLUE display please contact DixellPower supply Inputs BuzzerMeasurement unit Compressor output2 = 24Vac4 = 110Vac5 = 230VacA BCD ENP= NTC= PTC0 = No1 = YesC = °CF = °F0 = 8A1 = 20AKEYBOARDST 6 - 0BCD0WING K X W K - A 0 0 0 0For INOX version and BLUE display please contact DixellInputsBBuzzerCDMeasurement unitAPower supplyN = NTCP = PTC0 = No1 = YesC = °CF = °F2 = 24Vac4 = 110Vac5 = 230Vac32WING REFRIGERATION CONTROLLERS


WING BASICL, LS: 38x185mm V, VS: 100x64mm K: OSTHERMOSTATS and “OFF CYCLE” DEFROSTMULTIFUNCTION CONTROLLERSXW10LXW10VXW20KXW20LXW20LSXW20VXW20VSDigital thermostats for heating or cooling appli<strong>cat</strong>ions,with light relayDigital controllers for N. T. appli<strong>cat</strong>ions with “off cycle”defrost and light relayFEATURESXW1OLXW1OVXW2OKXW2OLXW2OLSXW2OVXW2OVSDisplay: n° digitsKeyboard: push buttonsPower supplyProbe inputsThermostatDefrostDisplayDigital inputsAlarm, start defrost, door switch,pressure switchRelay outputsCompressorDefrostFansLight, ON/OFFAlarmOtherHot Key/Prog Tool Kit outputBuzzer± 3 d.p.624Vac110, 230 VacNTC/PTCconfig8A, 20A opt8Apresopt± 3 d.p.624Vac110, 230 VacNTC/PTCconfig8A, 20A opt16Apresopton keyboard± 3 d.p.T62: 624Vac110, 230 VacNTC/PTC20A8A± 3 d.p.624Vac110, 230 VacNTC/PTCconfig8A, 20A opt8Aon keyboard* preson keyboard opt opt± 3 d.p.624Vac110, 230 VacNTC/PTC20A8Apresopt± 3 d.p.624Vac110, 230 VacNTC/PTCconfig8A, 20A opt16Apresopt± 3 d.p.624Vac110, 230 VacNTC/PTCNTC/PTCconfig16A16Apresopt*: only Hot Key outputXW10LXW20LXW20LSXW1OVXW20VXW20KXW20VSWING REFRIGERATION CONTROLLERS33


WING BASICL, LS: 38x185mm V, VS: 100x64mm K :OSMULTIFUNCTION CONTROLLERS for NORMAL,MEDIUM and LOW TEMPERATUREXW30VSXW35VSXW40KXW40LXW40VXW40VSDigital controllers for N. T. appli<strong>cat</strong>ions with “off cycle”defrost and alarm and light relayDigital controllers for N. T. appli<strong>cat</strong>ions with “off cycle”defrost and light and fan relayDigital controllers for M.T. and L.T. with electrical or hotgas defrost function and light relayFEATURESXW30VSXW35VSXW40KXW40LXW40VXW40VSDisplay: n° digitsKeyboard: push buttonsPower supplyProbe inputsThermostatDefrostDisplayDigital inputsAlarm, start defrost, doorswitch, pressure switchRelay outputsCompressorDefrostFansLight, ON/OFFAlarmOtherHot Key/Prog Tool Kit outputBuzzer± 3 d.p.624Vac110, 230VacNTC/PTCNTC/PTCconfig16A16A8Apresopt± 3 d.p.624Vac110, 230VacNTC/PTCNTC/PTCconfig16A8A16Apresopton keyboard± 3 d.p.624Vac110, 230VacNTC/PTCNTC/PTC20A8A8Aon keyboard*on keyboard opt± 3 d.p.624Vac110, 230VacNTC/PTCNTC/PTCconfig8A, 20A opt8A8Apresopt± 3 d.p.624Vac110, 230VacNTC/PTCNTC/PTCconfig8A, 20A opt8A16Apresopt± 3 d.p.624Vac110, 230VacNTC/PTCNTC/PTCNTC/PTCconfig16A16A8Apresopt*: only Hot Key outputXW30VSXW35VSXW40LXW40KXW40VXW40VS34WING REFRIGERATION CONTROLLERS


WING BASICMULTIFUNCTION CONTROLLERS for MEDIUM andLOW TEMPERATUREXW60KXW60LXW60LSXW60VXW60VSDigital controllers for M. T. and L. T. for ventilated appli<strong>cat</strong>ionswith door switch capabilityL, LS: 38x185mm V, VS: 100x64mm K: OSFEATURESXW6OKXW6OLXW6OLSXW6OVXW6OVSDisplay: n° digitsKeyboard: push buttonsPower supplyProbe inputsThermostatDefrostDisplayDigital inputsAlarm, start defrost, door switch,pressure switchRelay outputsCompressorDefrostFansLight, ON/OFFAlarmOtherHot Key/Prog Tool Kit outputBuzzeron keyboard± 3 d.p.T66: 624Vac110, 230VacNTC/PTCNTC/PTC20A8A8A8Aon keyboard*on keyboard opt± 3 d.p.624Vac110, 230VacNTC/PTCNTC/PTCconfig8A, 20A opt8A8A8Apresopt± 3 d.p.524Vac110, 230VacNTC/PTCNTC/PTCconfig20A8A8Apresopt± 3 d.p.624Vac110, 230VacNTC/PTCNTC/PTCconfig8A, 20A opt8A8A16Apresopt± 3 d.p.524Vac110, 230VacNTC/PTCNTC/PTCNTC/PTCconfig16A16A8Apresopt*: only Hot Key outputXW60LXW60LSXW6OV XW60K XW60VSWING REFRIGERATION CONTROLLERS35


WING BASICKEYBOARD for MULTIFUNCTION CONTROLLERSin K FORMATT626 key keyboard for XW20K controllerT646 key keyboard for XW40K controller38x185mmT666 key keyboard for XW60K controllerFEATUREST62T64T66Display: n° digitsKeyboard: push buttonsSlave moduleHot Key outputBuzzerMaximum distance accessible fromkeyboard-instrument± 3 d.p.6XW20Kpresopt1m± 3 d.p.6XW40Kpresopt1m± 3 d.p.6XW60Kpresopt1mT62T64T66The power modules in K format are available in open board version:OS: open board36WING REFRIGERATION CONTROLLERS


PARAMETERSREGULATIONSet pointDifferentialMinimum set pointMaximum set pointThermostat probe calibrationEvaporator probe presenceEvaporator probe calibrationOutputs activation delay at start upAnti-short cycle delayCompressor ON time during fast freezingCompressor ON time with faulty probeCompressor OFF time with faulty probeKind of action (cooling /heating)DISPLAYTemperature measurement unitResolution (integer/decimal point)Local display configurationDEFROSTDefrost typeDefrost modeSet point for smart defrostDefrost termination temperatureInterval between defrost cycles(Maximum) length for defrostStart defrost dalyDisplaying during defrostMax display delay after defrostDraining timeFirst defrost after startupDefrost delay after fast freezingFANSFans operating modeFans delay after defrost∆T for intermittent fan controlFans stop temperatureALARMSTemperature alarms configurationMaximum temperature alarmMinimum temperature alarmTemperature alarm differentialTemperature alarm delayDelay of temperature alarm at start upAlarm delay at the end of defrostDelay of temp. alarm after closing the doorOpen door alarm delayPressure switch activation numberANALOG INPUTSThermostat probe calibrationEvaporator probe calibrationDisplay probe calibrationEvaporator probe presenceDisplay probe presenceTemp. increasing during en. saving cycleDIGITAL INPUTOpen door controlConfigurable digital input polarityDigital input configurationDigital input alarm delayOTHERDisplaying probe 1Displaying probe 2Third relay configurationProbe type selectionSoftware releaseMap codeProbe displayingCODESetHyLSUSOtP2POEOdSACCCtConCOFCHCFrESLodtdFEdFSdFdtEIdFMdFdSddFddAdFdtdPOdAFFncFndFctFStALCALUALLAFHALddAOEdAdOtdOAnPSOtOEO3P2PP3PHESOdci2Pi2FdIddP1dP2OA1PbCrELPtbPrdXW10LXW10V●●◆◆◆●◆◆◆◆◆●◆●●◆●◆◆◆◆●◆◆◆◆◆◆◆◆XW20K●●◆◆●◆●◆◆◆◆◆●●●◆◆◆●●◆◆●◆◆XW20LXW20V●●◆◆◆●◆◆◆◆◆●●●◆◆◆◆●●◆●◆◆◆◆◆●◆◆◆◆◆◆◆◆XW20LS●●◆◆◆●◆◆◆◆◆●◆●●◆◆◆◆◆●●◆◆◆◆●◆◆◆◆XW20VS●●◆◆◆●◆◆◆◆◆●◆●●◆◆◆◆◆●●◆◆◆◆◆◆◆●◆◆◆◆◆◆◆◆◆◆◆XW30VSXW35VS●●◆◆◆●◆◆◆◆◆●◆◆●●◆◆◆◆◆◆◆●●◆◆◆◆◆◆◆◆◆◆◆◆◆◆◆◆◆◆◆XW40K●●◆◆●●◆◆●◆◆◆◆●◆●●●●◆◆◆◆◆◆◆●●◆◆◆◆●◆◆XW40LXW40V●●◆◆◆●◆◆◆◆●◆●◆◆●●●◆◆◆◆◆◆◆●●◆●◆◆◆◆◆●◆◆◆◆◆◆◆◆◆◆XW40VS●●◆◆◆●◆◆◆◆●◆●◆◆●●●◆◆◆◆◆◆◆●●◆●◆◆◆◆◆●◆◆◆◆◆◆◆◆◆◆XW60K●●◆◆●●◆◆●◆◆◆◆●◆●●●●◆◆◆◆◆◆●●◆●◆●●◆◆◆◆●◆◆XW60LXW60V●●◆◆◆●◆◆◆◆●◆●◆◆●●●◆◆◆◆◆◆●●●◆●●◆●◆◆◆◆◆●◆◆◆◆◆◆◆◆◆◆XW60LS●●◆◆◆●◆◆◆◆●◆◆◆◆●●●◆◆◆◆◆◆◆◆◆◆●●◆●◆◆●◆◆◆◆◆◆◆XW60VS●●◆◆◆●◆◆◆◆●◆◆◆◆●●●◆◆◆◆◆◆◆◆◆◆●●◆●◆◆◆◆◆●●●◆◆◆◆◆◆◆◆◆◆◆● Present◆ Present and password protectedWING REFRIGERATION CONTROLLERS37