156APPLICATION:<strong>Roof</strong> <strong>in</strong>sulation – structural pitched roofProduct: <strong>Jabroof</strong> SlimFixTraditional UK roofs are designed and constructed with the <strong>in</strong>sulation at ceil<strong>in</strong>glevel, leav<strong>in</strong>g a cold roof and under-used loft space. The <strong>Jabroof</strong> SlimFix <strong>in</strong>sulatedstructural pitched-roof system provides a new method of construct<strong>in</strong>g a tiled orslated pitched roof which offers structural support and, at the same time, satisfiesthe relevant U-value requirements. By spann<strong>in</strong>g from eaves to ridge with am<strong>in</strong>imum number of purl<strong>in</strong> supports, the <strong>Jabroof</strong> SlimFix system also provides auseful <strong>in</strong>sulated space <strong>in</strong> the roof void.<strong>Jabroof</strong> SlimFix<strong>Jabroof</strong> SlimFix consists of a sandwichconstruction <strong>in</strong>corporat<strong>in</strong>g a low lambdaexpanded polystyrene (EPS) core andmoisture-resistant chipboard fac<strong>in</strong>gs toprovide a warm-roof construction. Coldbridg<strong>in</strong>g at the structural members iselim<strong>in</strong>ated, substantially reduc<strong>in</strong>g the riskof condensation.ConstructionLongitud<strong>in</strong>al ribs and gutter laths ofEuropean Fir are fitted to the edges of the<strong>Jabroof</strong> SlimFix. Where ridge chamfer<strong>in</strong>g ofthe top end of the unit, to match the ridgeboard angle, is carried out <strong>in</strong> the factory,the top lath will be omitted. The upperlayer of chipboard has a factory-bonded,orange-coloured, moisture resistantchipboard fac<strong>in</strong>g, over which are fittedthree vertical counter battens. The lowerchipboard fac<strong>in</strong>g has a white f<strong>in</strong>ish.Longer spansFor new build<strong>in</strong>gs, a m<strong>in</strong>imum number ofpurl<strong>in</strong>s can be used with the structural<strong>Jabroof</strong> SlimFix units enabl<strong>in</strong>g longer spansto be achieved. (See <strong>Jabroof</strong> SlimFix spantables 29.3 – 29.8)VentilationCreat<strong>in</strong>g a warm-roof construction, which<strong>in</strong>cludes a breathable sark<strong>in</strong>g membrane,removes the need for ventilation of theroof void.<strong>Roof</strong>light open<strong>in</strong>gsSubject to dimensions and position,open<strong>in</strong>gs for rooflights or roof w<strong>in</strong>dows donot require trimm<strong>in</strong>g.Protection to servicesBecause the <strong>in</strong>sulation is at rafter level,the roof space rema<strong>in</strong>s warm, provid<strong>in</strong>gthermal protection to water services <strong>in</strong>the loft.Speed of construction<strong>Jabroof</strong> SlimFix is available <strong>in</strong> a choice oflengths provid<strong>in</strong>g fast, economical<strong>in</strong>stallation. Counter battens and gutterlaths are already fitted. The <strong>in</strong>sulatedstructural pitched roof system has been <strong>in</strong>use <strong>in</strong> Europe for over thirty years.Approvals<strong>Jabroof</strong> SlimFix has been assessed andapproved by the British Board of Agrément,certificate number 00/3696. The units aremanufactured <strong>in</strong> the Netherlands byVencel Resil’s sister company IsoBouwSystems bv.DimensionsLength: 3630 – 7520mmWidth: 1020mmTypeThe <strong>in</strong>sulation core of <strong>Jabroof</strong> SlimFix issupplied as low lambda EPS and classifiedas Class E, flame-retardant additivematerial, as def<strong>in</strong>ed <strong>in</strong> BS EN 13163.Shape<strong>Jabroof</strong> SlimFix is square-edged; ridgechamferedunits have a splayed edge atone end only.AccessoriesThe follow<strong>in</strong>g accessories are available:■ White plastic <strong>in</strong>ternal f<strong>in</strong>ish<strong>in</strong>g trimsfor the edges if required.■ In-situ polyurethane foam for seal<strong>in</strong>gjo<strong>in</strong>ts and gaps.■ Alum<strong>in</strong>ium-butyl rubber tape forseal<strong>in</strong>g horizontal butt jo<strong>in</strong>ts.■ Hooked nails to suit product.■ Threaded or profiled nails with hooks orwashers to suit product.■ Lift<strong>in</strong>g hoist.FireThe <strong>in</strong>sulation core is manufactured fromClass E, flame-retardant additive material.Where <strong>Jabroof</strong> SlimFix panels are exposed,12.5mm plasterboard will be required tobe fixed over them once they have been<strong>in</strong>stalled, <strong>in</strong> order to achieve a Class 1Surface Spread of Flame rat<strong>in</strong>g. Theexternal fire exposure rat<strong>in</strong>g will dependon the selected roof f<strong>in</strong>ish.Water-Vapour Transmission<strong>Jabroof</strong> SlimFix can be consideredto provide a vapour control if<strong>in</strong>stalled correctly.


157<strong>Roof</strong> <strong>in</strong>sulation – structural pitched roofU-valuesApproved documents L1 and L2 will recommend the required U-value for an <strong>in</strong>tegrated roof. Table 29.1 gives the U-values achievedbased on the various thicknesses of <strong>Jabroof</strong> SlimFix.Table 29.1<strong>Jabroof</strong> SlimFix Product and Properties<strong>Roof</strong> InsulationType: U-value (W/m 2 K)U-valuesOverall*Thickness (mm)Thickness of EPS<strong>in</strong>sulation (mm) Weight (Kg/m 2 )<strong>Jabroof</strong> SlimFix 79 8/8 0.37 95 79 14.6<strong>Jabroof</strong> SlimFix 97 8/8 0.31 113 97 15.3<strong>Jabroof</strong> SlimFix 113 8/8 0.27 129 113 16<strong>Jabroof</strong> SlimFix 131 8/8 0.24 147 131 16.7<strong>Jabroof</strong> SlimFix 157 8/8 0.20 173 157 17.7<strong>Jabroof</strong> SlimFix 195 8/8 0.16 211 195 19.5*exclud<strong>in</strong>g counter battensTable 29.2<strong>Jabroof</strong> SlimFix 195 plus additional thicknessof <strong>Jablite</strong> Premium board (mm)U value achieved (W/m²K)25 0.1450 0.1375 0.12100 0.11Table 29.2 shows how the U-value of <strong>Jabroof</strong> SlimFix 195 can be improved by us<strong>in</strong>g an additionalthickness of <strong>Jablite</strong> Premium board between 50mm-wide timber cross-battens at 600mm centres.For U-values for other comb<strong>in</strong>ation, please contact Vencel Resil's technical services department.For technical <strong>in</strong>formation 0870 444 8769 technical@jablite.co.uk


158APPLICATION:<strong>Roof</strong> <strong>in</strong>sulation – structural pitched roofFigure 29.1<strong>Roof</strong> tiles & battensRidge beam<strong>Jabroof</strong> SlimFixcounter batten<strong>Jabroof</strong> SlimFix<strong>Jablite</strong> Premium EPSPurl<strong>in</strong>Bottom fac<strong>in</strong>g<strong>Structural</strong> ornon-structuraltimber studWall plateLongitud<strong>in</strong>al ribGutter lath<strong>Structural</strong> floor


159<strong>Roof</strong> <strong>in</strong>sulation – structural pitched roofINSTALLATIONDesign<strong>Jabroof</strong> SlimFix units are simply lifted The follow<strong>in</strong>g general po<strong>in</strong>ts should be(a crane is recommended) and positioned noted:<strong>in</strong> accordance with the Vencel Resil layout ■ Most roof shapes on plan can bedraw<strong>in</strong>g provided. They are secured, <strong>in</strong> accommodated.accordance with the Vencel Resil fix<strong>in</strong>g ■ Maximum span depends on the roofschedule provided, to the wallplate, ridge pitch, w<strong>in</strong>d load<strong>in</strong>g, element load<strong>in</strong>g,beam and purl<strong>in</strong>(s) us<strong>in</strong>g a comb<strong>in</strong>ation of element thickness and weight of thehooked and washered nail fix<strong>in</strong>gs supplied roof cover<strong>in</strong>g and <strong>in</strong>ternal f<strong>in</strong>ishes.(See figures 29.2 – 29.5 for typical section ■ The design can <strong>in</strong>corporate gutterdraw<strong>in</strong>gs). All jo<strong>in</strong>ts between units should overhangs up to 700mm accord<strong>in</strong>g tobe tightly butted and sealed us<strong>in</strong>g the the roof pitch.<strong>in</strong>-situ polyurethane foam spray supplied, ■ Gable ends can overhang to awhich can also be used to seal gaps at the maximum of 150mm withoutridge. <strong>Roof</strong>light apertures are cut outadditional support.when the units have been <strong>in</strong>stalled. If ■ Trimm<strong>in</strong>g at open<strong>in</strong>gs is not requirednecessary, a breathable sark<strong>in</strong>g membrane provid<strong>in</strong>g they fall with<strong>in</strong> theis <strong>in</strong>stalled. Tile battens are nailed to the longitud<strong>in</strong>al timber ribs of onecounter battens and the roof f<strong>in</strong>ish isstructural unit.<strong>in</strong>stalled <strong>in</strong> the normal way.■ Chimney or flue penetrations should<strong>in</strong>clude a collar or other device toprevent the outer temperature of thechimney or flue exceed<strong>in</strong>g 90°C.■ Accepts a tile or slate f<strong>in</strong>ish. Concretetiles do not require a breathablemembrane <strong>in</strong> this application.For advice on other f<strong>in</strong>ishes pleasecontact Vencel Resil’s technical servicesdepartment.■ If the units are to be moved manually,they should be kept upside-down, i.e.with the counter battens downward sothat when they are slid upwards overthe wall plate and purl<strong>in</strong>s damage tothe <strong>in</strong>ternal face of the chipboard isavoided.■ Design advice is available from VencelResil’s technical services department.<strong>Roof</strong> InsulationFor technical <strong>in</strong>formation 0870 444 8769 technical@jablite.co.uk


160APPLICATION:<strong>Roof</strong> <strong>in</strong>sulation – structural pitched roofFigure 29.2Detail at eaves5321461. <strong>Jablite</strong> Premium EPS2. <strong>Jabroof</strong> SlimFix – 8mm Chipboard3. <strong>Jabroof</strong> SlimFix – Counter batten4. <strong>Jabroof</strong> SlimFix – Fix<strong>in</strong>g5. <strong>Roof</strong> tile and batten system6. Wall plateNote: Gutter and eaves detail will vary accord<strong>in</strong>g to requirementsFigure 29.3Detail at ridges1. <strong>Jablite</strong> Premium EPS2. <strong>Jabroof</strong> SlimFix – 8mm Chipboard3. <strong>Jabroof</strong> SlimFix – Counter batten21454. <strong>Jabroof</strong> SlimFix – Fix<strong>in</strong>g5. <strong>Roof</strong> tile and batten system6. 12.5mm Plasterboard7. Ridge beam367


161<strong>Roof</strong> <strong>in</strong>sulation – structural pitched roofFigure 29.4Detail at <strong>in</strong>termediate purl<strong>in</strong>5121. <strong>Jablite</strong> Premium EPS2. <strong>Jabroof</strong> SlimFix – 8mm Chipboard3. <strong>Jabroof</strong> SlimFix – Counter batten4. <strong>Jabroof</strong> SlimFix – Fix<strong>in</strong>g5. <strong>Roof</strong> tile and batten system6. 12.5mm Plasterboard7. Purl<strong>in</strong><strong>Roof</strong> Insulation3647Figure 29.5Detail at structural stud wall1. <strong>Jablite</strong> Premium EPS5122. <strong>Jabroof</strong> SlimFix – 8mm Chipboard3. <strong>Jabroof</strong> SlimFix – Counter batten4. <strong>Jabroof</strong> SlimFix – Fix<strong>in</strong>g5. <strong>Roof</strong> tile and batten system6. 12.5mm Plasterboard7. <strong>Structural</strong> timber stud3647For technical <strong>in</strong>formation 0870 444 8769 technical@jablite.co.uk